All MIBs › GDCUAS7626-MIB
Category: Vendor: GDC
Description: General DataComm UAS7626 unit MIB for 26-port universal access system management and statistics.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is GDCUAS7626-MIB?
GDCUAS7626-MIB is a General DataComm (GDC) module for the UAS7626 unit, a 26-port universal access system used for multiplexing/access aggregation in telecom networks. It exposes device identification and firmware data (version table, active/stored firmware revisions, download status), the ability to switch active firmware, and a per-line maintenance table indexed by line number. This MIB is heavily oriented toward hardware/software status monitoring: it lets an operator confirm the running and backup firmware revisions, watch firmware download/switchover status, and check maintenance state on individual access lines. It appears to be a standalone vendor MIB under the gdc/bql2 enterprise branches rather than depending on external standard MIBs. It would be deployed on GDC UAS7626 access multiplexer units in telecom carrier or enterprise WAN access environments, where a GDCUAS7626-MIB download lets an operator load the module directly into a MIB browser for compliance checks.
IPNetwork Monitor allows you to monitor SNMP objects defined in GDCUAS7626-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General DataComm UAS7626 access multiplexer
Monitoring Examples
An operator would poll uas7626VersionTable, via uas7626VersionIndex, to compare uas7626ActiveFirmwareRev against uas7626StoredFirmwareRev, and check uas7626StoredFirmwareStatus to see if a downloaded firmware image is ready to activate via uas7626SwitchActiveFirmware. Watching uas7626DownloadingMode reveals whether a firmware transfer is currently in progress. Per-line health can be checked in uas7626MaintenanceTable using uas7626MaintenanceLineIndex, flagging a specific access line in a maintenance or fault condition.
What Can Be Monitored
- active and stored firmware revision
- firmware download/stored status
- firmware download mode
- per-line maintenance status
- MIB/unit version
This MIB depends on
Related MIBs
Imported Objects
From GDCMACRO-MIB
| SCinstance |
From RFC-1212
| OBJECT-TYPE |
From RFC1155-SMI
| TimeTicks | |
| enterprises |
From RFC1213-MIB
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| gdc | 1.3.6.1.4.1.498 | |||
| bql2 | 1.3.6.1.4.1.498.12 | |||
| uas7626 | 1.3.6.1.4.1.498.12.12 | |||
| uas7626Version | 1.3.6.1.4.1.498.12.12.1 | |||
| STR uas7626MIBversion | 1.3.6.1.4.1.498.12.12.1.1 | DisplayString | read-only | Identifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y' identifies the minor revision number, 'z' identifies the typographical revision, and T identifies the test revision. Acceptable values for the individual revision components are as follows: x: 1 - 9 y: 0 - 9 z: 0 - 9 T: A - Z Upon formal release, no designation for the test revision will be present. |
| uas7626VersionTable | 1.3.6.1.4.1.498.12.12.1.2 | not-accessible | The 7626 version table | |
| uas7626VersionEntry | 1.3.6.1.4.1.498.12.12.1.2.1 | not-accessible | An entry in the GDC uas7626System Version Table. | |
| SCI uas7626VersionIndex | 1.3.6.1.4.1.498.12.12.1.2.1.1 | SCinstance | read-only | Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06) |
| STR uas7626ActiveFirmwareRev | 1.3.6.1.4.1.498.12.12.1.2.1.2 | DisplayString | read-only | The version number of the firmware currently executing. The format is MM.NN.BB where: MM: Major Revision (0-99) NN: Minor Revision (0-99) BB: Bug Fix Revision (0-99) Valid [i]nterface = 0 |
| STR uas7626StoredFirmwareRev | 1.3.6.1.4.1.498.12.12.1.2.1.3 | DisplayString | read-only | The version number of the firmware stored (in a compressed format) but not currently executing. MM: Major Revision (0-99) NN: Minor Revision (0-99) BB: Bug Fix Revision (0-99) Valid [i]nterface = 0 |
| INT uas7626StoredFirmwareStatus | 1.3.6.1.4.1.498.12.12.1.2.1.4 | INTEGER | read-only | This object represents the state of the Non-Active or Stored firmware: statBlank(1) Factory Default statDownLoading(2) In process of downloading firmware statOK(3) Zipped version checksum succesful (OK to switch) (can set uas7626SwitchActiveFirmware to switchActive(2)) statCheckSumBad(4) Failed checksum after download statUnZipping(5) In process of uncompressing into active area statBadUnZip(6) Failed last uncompress statDownloadAborted(7) Download aborted by user Valid [i]nterface = 0 |
| INT uas7626SwitchActiveFirmware | 1.3.6.1.4.1.498.12.12.1.2.1.5 | INTEGER | read-write | This object is used to switch the active executing firmware from the version in uas7626ActiveFirmwareRev to the version in uas7626StoredFirmwareRev. When a switchActive(2) is set (write only) the element will: 1) reboot 2) uncompress stored code into active area 3) perform checksum on active area 4) Set uas7626StoredStatus object to indicate results 5) If succesfull: update uas7626ActiveFirmwareRev and uas7626StoredFirmwareRev and begin executing If failed: replace active area with previous revision The switchNorm(1) enumeration will always be read. Setting switchActive(2) when the uas7626StoredFirmwareStatus is not statOK(3) will result in an error. Valid [i]nterface = 0 |
| INT uas7626DownloadingMode | 1.3.6.1.4.1.498.12.12.1.2.1.6 | INTEGER | read-write | This object is used to configure the download mode: disableAll(1) Prevents any firmware downloading to UAS7626 enableAndWait(2) Allows downloading zipped code to be stored only! enableAndSwitch(3) Allows downloading and then unzips and begins executing the new code Valid [i]nterface = 0 |
| uas7626Maintenance | 1.3.6.1.4.1.498.12.12.2 | |||
| uas7626MaintenanceTable | 1.3.6.1.4.1.498.12.12.2.1 | not-accessible | The table describes the maintenance objects for uas7626. | |
| uas7626MaintenanceEntry | 1.3.6.1.4.1.498.12.12.2.1.1 | not-accessible | An entry in the GDC 7626 Maintenance Table. | |
| SCI uas7626MaintenanceLineIndex | 1.3.6.1.4.1.498.12.12.2.1.1.1 | SCinstance | read-only | Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06) |
| INT uas7626SoftReset | 1.3.6.1.4.1.498.12.12.2.1.1.2 | INTEGER | read-write | Supports the action of soft resetting the unit. When this object is set to reset(2), then the unit performs a soft reset, whose meaning is specific to the type of unit being managed. The value of norm(1) will be returned when the reset is complete. The value of norm(1) can not be set by management. Valid [i]nterface = 0 |
| INT uas7626DefaultInit | 1.3.6.1.4.1.498.12.12.2.1.1.3 | INTEGER | read-write | This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault(2) the unit will perform a reset to make the default configuration take affect. The value of normal(1) will be returned when the initialization is complete. The value of normal(1) can not be set by management. Valid [i]nterface = 0 |
| INT uas7626ResetMajorAlarm | 1.3.6.1.4.1.498.12.12.2.1.1.4 | INTEGER | read-write | This variable is used to reset the Major BER alarm. A value of norm(1) cannot be set by management and will always be returned on a read. Valid [i]nterface = 01-06 |
| INT uas7626ResetMinorAlarm | 1.3.6.1.4.1.498.12.12.2.1.1.5 | INTEGER | read-write | This variable is used to reset the Minor BER alarm. A value of norm(1) cannot be set by management and will always be returned on a read. Valid [i]nterface = 01-06 |
| INT uas7626ResetStatistics | 1.3.6.1.4.1.498.12.12.2.1.1.6 | INTEGER | read-write | This variable is used to reset the performance intervals. When it is set to reset, the performance tables and uas7626Valid intervals are reset to zero. The value of norm(1) can not be set by management. Valid [i]nterface = 01-06 |
| INT uas7626ValidIntervals | 1.3.6.1.4.1.498.12.12.2.1.1.7 | INTEGER | read-only | The number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought on-line within the last 4 hours, in which case the value will be the number of complete 15 minute intervals the since interface has been online. Valid [i]nterface = 01-06 |
| INT uas7626SysUpTime | 1.3.6.1.4.1.498.12.12.2.1.1.8 | INTEGER | read-only | This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MIB-II. Upon power-up of the unit, the elapsed time is cleared. The elapsed time counter rolls over upon reaching the maximum count. Valid [i]nterface = 0 |
| OCT uas7626LedStatus | 1.3.6.1.4.1.498.12.12.2.1.1.9 | OCTET STRING | read-only | Returns a bitwise snapshot of the front panel LED state: key --- 001 = SOLID GREEN 010 = SOLID RED 011 = FLASHING RED 100 = FLASHING GREEN 1.7 - n/a 1.6 - \ 1.5 - -- Loop 1 (001, 010, 011, 100) 1.4 - / 1.3 - \ 1.2 - -- Loop 2 (001, 010, 011, 100)Y 1.1 - / 1.0 - f/u 2.7 - f/u 2.6 - \ 2.5 - -- Loop 3 (001, 010, 011, 100) 2.4 - / 2.3 - \ 2.2 - -- Loop 4 (001, 010, 011, 100) 2.1 - / 2.0 - f/u 3.7 - f/u 3.6 - \ 3.5 - -- Loop 5 (001, 010, 011, 100) 3.4 - / 3.3 - \ 3.2 - -- Loop 6 (001, 010, 011, 100) 3.1 - / 3.0 - f/u 4.7 - f/u 4.6 - f/u 4.5 - f/u 4.4 - Alarm (0 = Off; 1 = Alarm Active ) 4.3 - Test Mode (0 = Off; 1 = Alarm Active ) 4.2 - In Service (0 = Off; 1 = Alarm Active ) 4.1 - Transmitter Timing Failure (0 = Off; 1 = Alarm Active ) 4.0 - Management Response (0 = Off; 1 = Alarm Active ) Valid [i]nterface = 0 |
| OCT uas7626AlarmStatus | 1.3.6.1.4.1.498.12.12.2.1.1.10 | OCTET STRING | read-only | Returns actual bit-wise Status of alarms regardless of whether the alarm is masked or not. key --- 0 = Inactive 1 = Active 1.7 - f/u 1.6 - Power-up 1.5 - f/u 1.4 - f/u 1.3 - f/u 1.2 - f/u 1.1 - f/u 1.0 - f/u Note: n=2-6 for octets 2-7 n.7 - f/u n.6 - Loop n Major n.5 - Loop n Minor n.4 - Loop n Loss of Transmit Clock n.3 - Loop n 2B1Q Out of Sync n.2 - Loop n Sealing Current Non-Continuity Alarm n.1 - Loop n Errored Seconds n.0 - Loop n Unavailable Seconds Valid [i]nterface = 0 |
| TIK uas7626StatLastInitialized | 1.3.6.1.4.1.498.12.12.2.1.1.11 | TimeTicks | read-only | The elapsed time since the statistics were last initialized. This will be zero'd when uas7626ResetStatistics is reset(2). Valid [i]nterface = 01-06 |
| STR uas7626CircuitID | 1.3.6.1.4.1.498.12.12.2.1.1.12 | DisplayString | read-write | Name to identify the circuit. Valid [i]nterface = 01-06 |
| uas7626Configuration | 1.3.6.1.4.1.498.12.12.3 | |||
| uas7626ConfigTable | 1.3.6.1.4.1.498.12.12.3.1 | not-accessible | The GDC Configuration table. | |
| uas7626ConfigEntry | 1.3.6.1.4.1.498.12.12.3.1.1 | not-accessible | The GDC Configuration table entry. | |
| SCI uas7626ConfigIndex | 1.3.6.1.4.1.498.12.12.3.1.1.1 | SCinstance | read-only | Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06) |
| INT uas7626DataRate | 1.3.6.1.4.1.498.12.12.3.1.1.2 | INTEGER | read-write | Object to select the Data Rate on Loop n. Valid [i]nterface = 01-06 |
| INT uas7626Highway | 1.3.6.1.4.1.498.12.12.3.1.1.3 | INTEGER | read-write | Object to select the data highway for Loop n. Valid [i]nterface = 01-06 |
| INT uas7626TimeSlot | 1.3.6.1.4.1.498.12.12.3.1.1.4 | INTEGER | read-write | Object to select the timeslots for the data highway given by uas7624Highway for loop n. Valid selections are 1-31 and 64. A value of 64 indicates the loop is not assigned to a highway. Valid [i]nterface = 01-06 |
| uas7626Diagnostics | 1.3.6.1.4.1.498.12.12.4 | |||
| uas7626DiagTable | 1.3.6.1.4.1.498.12.12.4.1 | not-accessible | The GDC 7626 Diagnostics table. Information in the entries of this table support diagnostics testing, both active testing via patterns, and passive testing via loopbacks. | |
| uas7626DiagEntry | 1.3.6.1.4.1.498.12.12.4.1.1 | not-accessible | The GDC 7626 Diagnostics table entry. | |
| SCI uas7626DiagIndex | 1.3.6.1.4.1.498.12.12.4.1.1.1 | SCinstance | read-only | Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06) |
| INT uas7626TestSelection | 1.3.6.1.4.1.498.12.12.4.1.1.2 | INTEGER | read-write | Selects the test to run. A selection of stopTest(1) stops the current test. Valid [i]nterface = 01-06 |
| INT uas7626TestResults | 1.3.6.1.4.1.498.12.12.4.1.1.3 | INTEGER | read-only | Returns the self test bit error count. Valid [i]nterface = 01-06 |
| INT uas7626ResetTestResults | 1.3.6.1.4.1.498.12.12.4.1.1.4 | INTEGER | read-write | Resets the self test bit error count. A value of norm(1) cannot be set by management and is always returned on a read. Valid [i]nterface = 01-06 |
| uas7626Performance | 1.3.6.1.4.1.498.12.12.5 | |||
| uas7626CurrentTable | 1.3.6.1.4.1.498.12.12.5.3 | not-accessible | The uas7626 Current table contains various statistics being collected for the current 15 minute interval. | |
| uas7626CurrentEntry | 1.3.6.1.4.1.498.12.12.5.3.1 | not-accessible | An entry in the uas7626 Current table. | |
| SCI uas7626CurrentIndex | 1.3.6.1.4.1.498.12.12.5.3.1.1 | SCinstance | read-only | Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06) |
| OCT uas7626CurrentStat | 1.3.6.1.4.1.498.12.12.5.3.1.2 | OCTET STRING | read-only | Returns a bitwise snapshot of the current 15 minute statistics: Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 3 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 4 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 5 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 6 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 8 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 9 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) Valid [i]nterface = 01-06 |
| uas7626IntervalTable | 1.3.6.1.4.1.498.12.12.5.4 | not-accessible | The uas7626 Interval table contains various statistics collected by each Interface over the last 16 15-minute intervals. | |
| uas7626IntervalEntry | 1.3.6.1.4.1.498.12.12.5.4.1 | not-accessible | An entry in the Interval table. | |
| SCI uas7626IntervalIndex | 1.3.6.1.4.1.498.12.12.5.4.1.1 | SCinstance | read-only | Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06) |
| INT uas7626IntervalNumber | 1.3.6.1.4.1.498.12.12.5.4.1.2 | INTEGER | read-only | The interval number 1- 16. Valid [i]nterface = 01-06 |
| OCT uas7626IntervalStat | 1.3.6.1.4.1.498.12.12.5.4.1.3 | OCTET STRING | read-only | Returns a bitwise snapshot of the interval statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Interval Octet 3 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 4 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 5 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 6 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 7 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 8 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 9 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 10 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 11 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) Valid [i]nterface = 01-06 |
| uas7626TotalTable | 1.3.6.1.4.1.498.12.12.5.5 | not-accessible | The uas7626 Total Table contains the totals of the various statistics collected for the current 24 hour period for each interface. | |
| uas7626TotalEntry | 1.3.6.1.4.1.498.12.12.5.5.1 | not-accessible | An entry in the uas7626 Total table. | |
| SCI uas7626TotalIndex | 1.3.6.1.4.1.498.12.12.5.5.1.1 | SCinstance | read-only | Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06) |
| OCT uas7626TotalStat | 1.3.6.1.4.1.498.12.12.5.5.1.2 | OCTET STRING | read-only | Returns a bitwise snapshot of the current 24 hour statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 3 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 4 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 5 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 6 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 8 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 9 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 11 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^23 bit 1 - 2^22 bit 0 - 2^21 Octet 12 bit 7 - not used bit 6 - 2^20 bit 5 - 2^19 bit 4 - 2^18 bit 3 - 2^17 bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 13 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 14 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) Valid [i]nterface = 01-06 |
| uas7626Recent24HrTable | 1.3.6.1.4.1.498.12.12.5.6 | not-accessible | The Recent 24 Hour table contains the totals of the various statistics collected for the previous 24 hour period for each interface. | |
| uas7626Recent24HrEntry | 1.3.6.1.4.1.498.12.12.5.6.1 | not-accessible | An entry in the Recent24Hr table. | |
| SCI uas7626Recent24HrIndex | 1.3.6.1.4.1.498.12.12.5.6.1.1 | SCinstance | read-only | Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06) |
| OCT uas7626Recent24HrStat | 1.3.6.1.4.1.498.12.12.5.6.1.2 | OCTET STRING | read-only | Returns a bitwise snapshot of the recent 24 hour statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 3 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 4 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 5 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 6 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 8 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 9 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 11 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^23 bit 1 - 2^22 bit 0 - 2^21 Octet 12 bit 7 - not used bit 6 - 2^20 bit 5 - 2^19 bit 4 - 2^18 bit 3 - 2^17 bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 13 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 14 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) Valid [i]nterface = 01-06 |
| uas7626UnavailableTimeRegTable | 1.3.6.1.4.1.498.12.12.5.7 | not-accessible | The 7626 Unavailable Time Register table. | |
| uas7626UnavailableTimeRegEntry | 1.3.6.1.4.1.498.12.12.5.7.1 | not-accessible | An entry in the Unavailable Time Register table. | |
| SCI uas7626UnavailableTimeRegIndex | 1.3.6.1.4.1.498.12.12.5.7.1.1 | SCinstance | read-only | Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06) |
| INT uas7626UnavailableTimeRegNumber | 1.3.6.1.4.1.498.12.12.5.7.1.2 | INTEGER | read-only | A number between 1 and 6, where the number is the number of the Unavailable Time Register. |
| INT uas7626UnavailableTimeRegStart | 1.3.6.1.4.1.498.12.12.5.7.1.3 | INTEGER | read-only | Start time of one of the Unavailable Time Registers. |
| INT uas7626UnavailableTimeRegStop | 1.3.6.1.4.1.498.12.12.5.7.1.4 | INTEGER | read-only | Stop time of one of the Unavailable Time Registers. |
| uas7626AlarmConfig | 1.3.6.1.4.1.498.12.12.6 | |||
| uas7626AlarmConfigTable | 1.3.6.1.4.1.498.12.12.6.1 | not-accessible | This table contains entries that configure Alarm reporting. | |
| uas7626AlarmConfigEntry | 1.3.6.1.4.1.498.12.12.6.1.1 | not-accessible | An entry in the uas7626 Alarm Configuration table. | |
| SCI uas7626AlarmConfigIndex | 1.3.6.1.4.1.498.12.12.6.1.1.1 | SCinstance | read-only | Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06) |
| OID uas7626AlarmConfigIdentifier | 1.3.6.1.4.1.498.12.12.6.1.1.2 | OBJECT IDENTIFIER | read-only | format: iso.org.dod.internet.private.enterprises.gdc. bql2.uas7626.uas7626Alarms.ALM example: 1.3.6.1.4.1.498.12.12.7.ALM where ALM = 1 for uas7626NoResponse alarm, 2 for uas7626DiagRxErr alarm, etc., as specified in the Alarm Definitions above. |
| INT uas7626AlarmCountThreshold | 1.3.6.1.4.1.498.12.12.6.1.1.3 | INTEGER | read-write | This function sets/reads the alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given time frame for an alarm to occur before the alarm is considered active. Valid [i]nterface = 01-06 |
| uas7626LocalAlarmConfigTable | 1.3.6.1.4.1.498.12.12.6.2 | not-accessible | The uas7626LocalAlarmConfigTable contains entries that configure alarm reporting to the alarm card. | |
| uas7626LocalAlarmConfigEntry | 1.3.6.1.4.1.498.12.12.6.2.1 | not-accessible | An entry in the GDC Local Alarm Configuration table. | |
| SCI uas7626LocalAlarmConfigIndex | 1.3.6.1.4.1.498.12.12.6.2.1.1 | SCinstance | read-only | Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06) |
| INT uas7626LossOfClockLocal | 1.3.6.1.4.1.498.12.12.6.2.1.2 | INTEGER | read-write | Disables or enables the alarm on the Major buss or Minor Buss. Valid [i]nterface = 01-06 |
| INT uas7626ESLocal | 1.3.6.1.4.1.498.12.12.6.2.1.3 | INTEGER | read-write | Disables or enables the alarm on the Major buss or Minor Buss. Valid [i]nterface = 01-06 |
| INT uas7626UASLocal | 1.3.6.1.4.1.498.12.12.6.2.1.4 | INTEGER | read-write | Disables or enables the alarm on the Major buss or Minor Buss. Valid [i]nterface = 01-06 |
| INT uas7626OutofSyncLocal | 1.3.6.1.4.1.498.12.12.6.2.1.5 | INTEGER | read-write | Disables or enables the alarm on the Major buss or Minor Buss. Valid [i]nterface = 01-06 |
| INT uas7626NoSealingCurrentLocal | 1.3.6.1.4.1.498.12.12.6.2.1.6 | INTEGER | read-write | Disables or enables the alarm on the Major buss or Minor Buss. Valid [i]nterface = 01-06 |
| uas7626Alarms | 1.3.6.1.4.1.498.12.12.7 | |||
| uas7626NoResponseAlm | 1.3.6.1.4.1.498.12.12.7.1 | |||
| uas7626DiagRxErrAlm | 1.3.6.1.4.1.498.12.12.7.2 | |||
| uas7626PowerUpAlm | 1.3.6.1.4.1.498.12.12.7.3 | |||
| uas7626LossofTransmitClockAlm | 1.3.6.1.4.1.498.12.12.7.4 | |||
| uas7626OutofSyncAlm | 1.3.6.1.4.1.498.12.12.7.5 | |||
| uas7626SealingCurrentNoContAlm | 1.3.6.1.4.1.498.12.12.7.6 | |||
| uas7626UASAlm | 1.3.6.1.4.1.498.12.12.7.7 | |||
| uas7626ESAlm | 1.3.6.1.4.1.498.12.12.7.8 | |||
| uas7626MajorBERAlm | 1.3.6.1.4.1.498.12.12.7.9 | |||
| uas7626MinorBERAlm | 1.3.6.1.4.1.498.12.12.7.10 |
RFC description
Manages configuration, diagnostics, and performance monitoring for GDC UAS7626 telecom equipment.
Start monitoring General DataComm (GDC) UAS7626 26-port access multiplexer with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.