-- Copyright 1998 General DataComm Inc., Inc. All Rights Reserved. -- -- Reproduction of this document is authorized on condition that the -- foregoing copyright notice is included. This General DataComm, GDC, -- SNMP Management Information Base Specification embodies GDCs' -- confidential and proprietary intellectual property. GDC retains all -- title and ownership in the Specification, including any revisions. -- -- It is GDCs intent to encourage the widespread use of this Specification -- in connection with the management of GDC's products. GDC grants vendors, -- end-users, and other interested parties a non-exclusive license to use -- this Specification in connection with the management of GDC's products. -- -- This Specification is supplied "AS IS," and GDC makes no warranty, -- either expressed or implied, as to the use operation, condition, or -- performance of the Specification. -- -- GDC UAS7626 MIB -- ************************************************************************** -- Revision History -- ************************************************************************** -- Version Date Name Description -- 1.00A 26-Jan-98 C. Amorossi Initial Revision. -- 1.00B 09-Feb-98 C. Amorossi Added uas7626CircuitID -- 1.00C 21-Apr-98 C. Amorossi Changed description of -- uas7626AlarmStatus -- 1.00D 31-Aug-98 C. Amorossi Added -- uas7626UnavailableTimeRegTable -- *************************************************************************** -- *************************************************************************** -- MIB definitions begin -- *************************************************************************** GDCUAS7626-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises,TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB SCinstance FROM GDCMACRO-MIB; gdc OBJECT IDENTIFIER ::= { enterprises 498 } bql2 OBJECT IDENTIFIER ::= { gdc 12 } uas7626 OBJECT IDENTIFIER ::= { bql2 12 } uas7626Version OBJECT IDENTIFIER ::= { uas7626 1 } uas7626Maintenance OBJECT IDENTIFIER ::= { uas7626 2 } uas7626Configuration OBJECT IDENTIFIER ::= { uas7626 3 } uas7626Diagnostics OBJECT IDENTIFIER ::= { uas7626 4 } uas7626Performance OBJECT IDENTIFIER ::= { uas7626 5 } uas7626AlarmConfig OBJECT IDENTIFIER ::= { uas7626 6 } uas7626Alarms OBJECT IDENTIFIER ::= { uas7626 7 } -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC 1212. -- Note: All rows in all tables defined within this MIB module are -- virtual. They can neither be created or deleted by management -- operations. -- --**************************************************************************** -- SCinstance is defined as the addressing/indexing method of accessing -- table objects in this MIB. The SCinstance represents the SpectraComm -- shelf Slot, Line, Drop and interface address. -- Represented as SLDi, (Slot, Line, Drop, interface). -- -- -- For the uas7626: -- -- Byte Range (dec.) Identifies -- ---- ------------ ---------- -- [S]lot 1 - 32 Physical Slot -- 1-16: 1st Shelf -- 17-32: 2nd Shelf -- -- [L]ine 1 -- -- [D]rop 0 -- -- [i]nterface 0 - 6 0: Unit -- 1: Loop 1 -- 2: Loop 2 -- 3: Loop 3 -- 4: Loop 4 -- 5: Loop 5 -- 6: Loop 6 -- -- **************************************************************************** -- uas7626MIBversion OBJECT-TYPE SYNTAX DisplayString (SIZE (5)) ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y' identifies the minor revision number, 'z' identifies the typographical revision, and T identifies the test revision. Acceptable values for the individual revision components are as follows: x: 1 - 9 y: 0 - 9 z: 0 - 9 T: A - Z Upon formal release, no designation for the test revision will be present." ::= { uas7626Version 1 } -- **************************************************************************** -- Version Table -- **************************************************************************** uas7626VersionTable OBJECT-TYPE SYNTAX SEQUENCE OF Uas7626VersionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The 7626 version table " ::= { uas7626Version 2 } uas7626VersionEntry OBJECT-TYPE SYNTAX Uas7626VersionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the GDC uas7626System Version Table." INDEX { uas7626VersionIndex } ::= { uas7626VersionTable 1 } Uas7626VersionEntry ::= SEQUENCE { uas7626VersionIndex SCinstance, uas7626ActiveFirmwareRev DisplayString, uas7626StoredFirmwareRev DisplayString, uas7626StoredFirmwareStatus INTEGER, uas7626SwitchActiveFirmware INTEGER, uas7626DownloadingMode INTEGER } uas7626VersionIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06)" ::= { uas7626VersionEntry 1 } uas7626ActiveFirmwareRev OBJECT-TYPE SYNTAX DisplayString (SIZE(8)) ACCESS read-only STATUS mandatory DESCRIPTION "The version number of the firmware currently executing. The format is MM.NN.BB where: MM: Major Revision (0-99) NN: Minor Revision (0-99) BB: Bug Fix Revision (0-99) Valid [i]nterface = 0" ::= { uas7626VersionEntry 2 } uas7626StoredFirmwareRev OBJECT-TYPE SYNTAX DisplayString (SIZE(8)) ACCESS read-only STATUS mandatory DESCRIPTION "The version number of the firmware stored (in a compressed format) but not currently executing. MM: Major Revision (0-99) NN: Minor Revision (0-99) BB: Bug Fix Revision (0-99) Valid [i]nterface = 0" ::= { uas7626VersionEntry 3 } uas7626StoredFirmwareStatus OBJECT-TYPE SYNTAX INTEGER { statBlank(1), statDownLoading(2), statOK(3), statCheckSumBad(4), statUnZipping(5), statBadUnZip(6), statDownloadAborted(7) } ACCESS read-only STATUS mandatory DESCRIPTION "This object represents the state of the Non-Active or Stored firmware: statBlank(1) Factory Default statDownLoading(2) In process of downloading firmware statOK(3) Zipped version checksum succesful (OK to switch) (can set uas7626SwitchActiveFirmware to switchActive(2)) statCheckSumBad(4) Failed checksum after download statUnZipping(5) In process of uncompressing into active area statBadUnZip(6) Failed last uncompress statDownloadAborted(7) Download aborted by user Valid [i]nterface = 0" ::= { uas7626VersionEntry 4 } uas7626SwitchActiveFirmware OBJECT-TYPE SYNTAX INTEGER { switchNorm(1), -- Read only switchActive(2) -- Write only } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to switch the active executing firmware from the version in uas7626ActiveFirmwareRev to the version in uas7626StoredFirmwareRev. When a switchActive(2) is set (write only) the element will: 1) reboot 2) uncompress stored code into active area 3) perform checksum on active area 4) Set uas7626StoredStatus object to indicate results 5) If succesfull: update uas7626ActiveFirmwareRev and uas7626StoredFirmwareRev and begin executing If failed: replace active area with previous revision The switchNorm(1) enumeration will always be read. Setting switchActive(2) when the uas7626StoredFirmwareStatus is not statOK(3) will result in an error. Valid [i]nterface = 0" ::= { uas7626VersionEntry 5 } uas7626DownloadingMode OBJECT-TYPE SYNTAX INTEGER { disableAll(1), enableAndWait(2), enableAndSwitch(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to configure the download mode: disableAll(1) Prevents any firmware downloading to UAS7626 enableAndWait(2) Allows downloading zipped code to be stored only! enableAndSwitch(3) Allows downloading and then unzips and begins executing the new code Valid [i]nterface = 0" ::= { uas7626VersionEntry 6 } -- -- ********************************************************* -- GDC uas7626 Maintenance Table -- ********************************************************** uas7626MaintenanceTable OBJECT-TYPE SYNTAX SEQUENCE OF Uas7626MaintenanceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table describes the maintenance objects for uas7626." ::= { uas7626Maintenance 1 } uas7626MaintenanceEntry OBJECT-TYPE SYNTAX Uas7626MaintenanceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the GDC 7626 Maintenance Table." INDEX { uas7626MaintenanceLineIndex } ::= { uas7626MaintenanceTable 1 } Uas7626MaintenanceEntry ::= SEQUENCE { uas7626MaintenanceLineIndex SCinstance, uas7626SoftReset INTEGER, uas7626DefaultInit INTEGER, uas7626ResetMajorAlarm INTEGER, uas7626ResetMinorAlarm INTEGER, uas7626ResetStatistics INTEGER, uas7626ValidIntervals INTEGER, uas7626SysUpTime INTEGER, uas7626LedStatus OCTET STRING, uas7626AlarmStatus OCTET STRING, uas7626StatLastInitialized TimeTicks, uas7626CircuitID DisplayString } uas7626MaintenanceLineIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06)" ::= { uas7626MaintenanceEntry 1 } uas7626SoftReset OBJECT-TYPE SYNTAX INTEGER { norm(1), -- read-only reset(2) -- write-only } ACCESS read-write STATUS mandatory DESCRIPTION "Supports the action of soft resetting the unit. When this object is set to reset(2), then the unit performs a soft reset, whose meaning is specific to the type of unit being managed. The value of norm(1) will be returned when the reset is complete. The value of norm(1) can not be set by management. Valid [i]nterface = 0" ::= { uas7626MaintenanceEntry 2 } uas7626DefaultInit OBJECT-TYPE SYNTAX INTEGER { normal(1), -- read-only factoryDefault(2) -- write-only } ACCESS read-write STATUS mandatory DESCRIPTION "This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault(2) the unit will perform a reset to make the default configuration take affect. The value of normal(1) will be returned when the initialization is complete. The value of normal(1) can not be set by management. Valid [i]nterface = 0" ::= { uas7626MaintenanceEntry 3 } uas7626ResetMajorAlarm OBJECT-TYPE SYNTAX INTEGER { norm(1), -- read-only reset(2) -- write-only } ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to reset the Major BER alarm. A value of norm(1) cannot be set by management and will always be returned on a read. Valid [i]nterface = 01-06" ::= { uas7626MaintenanceEntry 4 } uas7626ResetMinorAlarm OBJECT-TYPE SYNTAX INTEGER { norm(1), -- read-only reset(2) -- write-only } ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to reset the Minor BER alarm. A value of norm(1) cannot be set by management and will always be returned on a read. Valid [i]nterface = 01-06" ::= { uas7626MaintenanceEntry 5 } uas7626ResetStatistics OBJECT-TYPE SYNTAX INTEGER { norm(1), -- read-only reset(2) -- write-only } ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to reset the performance intervals. When it is set to reset, the performance tables and uas7626Valid intervals are reset to zero. The value of norm(1) can not be set by management. Valid [i]nterface = 01-06" ::= { uas7626MaintenanceEntry 6 } uas7626ValidIntervals OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION "The number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought on-line within the last 4 hours, in which case the value will be the number of complete 15 minute intervals the since interface has been online. Valid [i]nterface = 01-06" ::= {uas7626MaintenanceEntry 7 } uas7626SysUpTime OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MIB-II. Upon power-up of the unit, the elapsed time is cleared. The elapsed time counter rolls over upon reaching the maximum count. Valid [i]nterface = 0" ::= { uas7626MaintenanceEntry 8 } uas7626LedStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise snapshot of the front panel LED state: key --- 001 = SOLID GREEN 010 = SOLID RED 011 = FLASHING RED 100 = FLASHING GREEN 1.7 - n/a 1.6 - \ 1.5 - -- Loop 1 (001, 010, 011, 100) 1.4 - / 1.3 - \ 1.2 - -- Loop 2 (001, 010, 011, 100)Y 1.1 - / 1.0 - f/u 2.7 - f/u 2.6 - \ 2.5 - -- Loop 3 (001, 010, 011, 100) 2.4 - / 2.3 - \ 2.2 - -- Loop 4 (001, 010, 011, 100) 2.1 - / 2.0 - f/u 3.7 - f/u 3.6 - \ 3.5 - -- Loop 5 (001, 010, 011, 100) 3.4 - / 3.3 - \ 3.2 - -- Loop 6 (001, 010, 011, 100) 3.1 - / 3.0 - f/u 4.7 - f/u 4.6 - f/u 4.5 - f/u 4.4 - Alarm (0 = Off; 1 = Alarm Active ) 4.3 - Test Mode (0 = Off; 1 = Alarm Active ) 4.2 - In Service (0 = Off; 1 = Alarm Active ) 4.1 - Transmitter Timing Failure (0 = Off; 1 = Alarm Active ) 4.0 - Management Response (0 = Off; 1 = Alarm Active ) Valid [i]nterface = 0" ::= { uas7626MaintenanceEntry 9 } uas7626AlarmStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE(7)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns actual bit-wise Status of alarms regardless of whether the alarm is masked or not. key --- 0 = Inactive 1 = Active 1.7 - f/u 1.6 - Power-up 1.5 - f/u 1.4 - f/u 1.3 - f/u 1.2 - f/u 1.1 - f/u 1.0 - f/u Note: n=2-6 for octets 2-7 n.7 - f/u n.6 - Loop n Major n.5 - Loop n Minor n.4 - Loop n Loss of Transmit Clock n.3 - Loop n 2B1Q Out of Sync n.2 - Loop n Sealing Current Non-Continuity Alarm n.1 - Loop n Errored Seconds n.0 - Loop n Unavailable Seconds Valid [i]nterface = 0" ::= {uas7626MaintenanceEntry 10} uas7626StatLastInitialized OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The elapsed time since the statistics were last initialized. This will be zero'd when uas7626ResetStatistics is reset(2). Valid [i]nterface = 01-06" ::= {uas7626MaintenanceEntry 11 } uas7626CircuitID OBJECT-TYPE SYNTAX DisplayString (SIZE(16)) ACCESS read-write STATUS mandatory DESCRIPTION "Name to identify the circuit. Valid [i]nterface = 01-06" ::= {uas7626MaintenanceEntry 12 } -- -- ******************************************************************** -- The GDC 7626 Configuration Table -- ******************************************************************** -- uas7626ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Uas7626ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC Configuration table." ::= { uas7626Configuration 1 } uas7626ConfigEntry OBJECT-TYPE SYNTAX Uas7626ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC Configuration table entry." INDEX { uas7626ConfigIndex } ::= { uas7626ConfigTable 1 } Uas7626ConfigEntry ::= SEQUENCE { uas7626ConfigIndex SCinstance, uas7626DataRate INTEGER, uas7626Highway INTEGER, uas7626TimeSlot INTEGER } uas7626ConfigIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06)" ::= { uas7626ConfigEntry 1 } uas7626DataRate OBJECT-TYPE SYNTAX INTEGER { kbps64(1), kbps128(2), inhibit(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Object to select the Data Rate on Loop n. Valid [i]nterface = 01-06" ::= { uas7626ConfigEntry 2 } uas7626Highway OBJECT-TYPE SYNTAX INTEGER { notAssigned(1), highway1(2), highway2(3), highway3(4), highway4(5), highway5(6), highway6(7), highway7(8), highway8(9) } ACCESS read-write STATUS mandatory DESCRIPTION "Object to select the data highway for Loop n. Valid [i]nterface = 01-06" ::= {uas7626ConfigEntry 3} uas7626TimeSlot OBJECT-TYPE SYNTAX INTEGER(1..64) ACCESS read-write STATUS mandatory DESCRIPTION "Object to select the timeslots for the data highway given by uas7624Highway for loop n. Valid selections are 1-31 and 64. A value of 64 indicates the loop is not assigned to a highway. Valid [i]nterface = 01-06" ::= {uas7626ConfigEntry 4} -- -- ******************************************************************** -- GDC 7626 Diagnostics -- ******************************************************************** -- This table contains the diagnostic test information. uas7626DiagTable OBJECT-TYPE SYNTAX SEQUENCE OF Uas7626DiagEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC 7626 Diagnostics table. Information in the entries of this table support diagnostics testing, both active testing via patterns, and passive testing via loopbacks." ::= { uas7626Diagnostics 1 } uas7626DiagEntry OBJECT-TYPE SYNTAX Uas7626DiagEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC 7626 Diagnostics table entry." INDEX { uas7626DiagIndex } ::= { uas7626DiagTable 1 } Uas7626DiagEntry ::= SEQUENCE { uas7626DiagIndex SCinstance, uas7626TestSelection INTEGER, uas7626TestResults INTEGER, uas7626ResetTestResults INTEGER } uas7626DiagIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06)" ::= { uas7626DiagEntry 1 } uas7626TestSelection OBJECT-TYPE SYNTAX INTEGER { stopTest(1), digitalLoopback(2), selfTest(3), remoteDigitalLoopback(4), rdlSelfTest(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects the test to run. A selection of stopTest(1) stops the current test. Valid [i]nterface = 01-06" ::= { uas7626DiagEntry 2 } uas7626TestResults OBJECT-TYPE SYNTAX INTEGER(0..1048576) ACCESS read-only STATUS mandatory DESCRIPTION "Returns the self test bit error count. Valid [i]nterface = 01-06" ::= { uas7626DiagEntry 3 } uas7626ResetTestResults OBJECT-TYPE SYNTAX INTEGER { norm(1), -- read-only reset(2) -- write-only } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the self test bit error count. A value of norm(1) cannot be set by management and is always returned on a read. Valid [i]nterface = 01-06" ::= { uas7626DiagEntry 4 } -- -- ******************************************************************** -- GDC uas7626 Alarm Object Identifier Definitions -- ******************************************************************** uas7626NoResponseAlm OBJECT IDENTIFIER ::= {uas7626Alarms 1} uas7626DiagRxErrAlm OBJECT IDENTIFIER ::= {uas7626Alarms 2} uas7626PowerUpAlm OBJECT IDENTIFIER ::= {uas7626Alarms 3} uas7626LossofTransmitClockAlm OBJECT IDENTIFIER ::= {uas7626Alarms 4} uas7626OutofSyncAlm OBJECT IDENTIFIER ::= {uas7626Alarms 5} uas7626SealingCurrentNoContAlm OBJECT IDENTIFIER ::= {uas7626Alarms 6} uas7626UASAlm OBJECT IDENTIFIER ::= {uas7626Alarms 7} uas7626ESAlm OBJECT IDENTIFIER ::= {uas7626Alarms 8} uas7626MajorBERAlm OBJECT IDENTIFIER ::= {uas7626Alarms 9} uas7626MinorBERAlm OBJECT IDENTIFIER ::= {uas7626Alarms 10} -- ALARM Mask- Valid Thres -- able int -- ============================================================================ -- uas7626NoResponseAlm no 0 no -- uas7626DiagRxErrAlm no 0 no -- uas7626PowerUpAlm no 0 no -- uas7626LossofTransmitClockAlm yes 1-6 no -- uas7626OutofSyncAlm yes 1-6 no -- uas7626SealingCurrentNoContAlm yes 1-6 no -- uas7626UASAlm yes 1-6 no -- uas7626ESAlm yes 1-6 no -- uas7626MajorBERAlm yes 1-6 yes -- uas7626MinorBERAlm yes 1-6 yes -- -- ******************************************************************** -- GDC uas7626 Alarm Configuration -- ******************************************************************** uas7626AlarmConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Uas7626AlarmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains entries that configure Alarm reporting." ::= { uas7626AlarmConfig 1 } uas7626AlarmConfigEntry OBJECT-TYPE SYNTAX Uas7626AlarmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the uas7626 Alarm Configuration table." INDEX { uas7626AlarmConfigIndex, uas7626AlarmConfigIdentifier } ::= { uas7626AlarmConfigTable 1 } Uas7626AlarmConfigEntry ::= SEQUENCE { uas7626AlarmConfigIndex SCinstance, uas7626AlarmConfigIdentifier OBJECT IDENTIFIER, uas7626AlarmCountThreshold INTEGER } uas7626AlarmConfigIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06)" ::= { uas7626AlarmConfigEntry 1 } uas7626AlarmConfigIdentifier OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "format: iso.org.dod.internet.private.enterprises.gdc. bql2.uas7626.uas7626Alarms.ALM example: 1.3.6.1.4.1.498.12.12.7.ALM where ALM = 1 for uas7626NoResponse alarm, 2 for uas7626DiagRxErr alarm, etc., as specified in the Alarm Definitions above." ::= { uas7626AlarmConfigEntry 2 } uas7626AlarmCountThreshold OBJECT-TYPE SYNTAX INTEGER { thres10E03(1), thres10E04(2), thres10E05(3), thres10E06(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This function sets/reads the alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given time frame for an alarm to occur before the alarm is considered active. Valid [i]nterface = 01-06" ::= { uas7626AlarmConfigEntry 3 } -- -- ******************************************************************** -- GDC LOCAL uas7626 Alarm Configuration -- ******************************************************************** -- Local Alarms are alarms that optionally activate the backplane -- Major or Minor buses. These alarms changes are never reported in an -- unsolicited message to the proxy agent hence, the reason for the alarm -- card. These alarms are different from the previously defined alarms -- in that the mask state has three possible values. uas7626LocalAlarmConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Uas7626LocalAlarmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The uas7626LocalAlarmConfigTable contains entries that configure alarm reporting to the alarm card." ::= { uas7626AlarmConfig 2 } uas7626LocalAlarmConfigEntry OBJECT-TYPE SYNTAX Uas7626LocalAlarmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the GDC Local Alarm Configuration table." INDEX { uas7626LocalAlarmConfigIndex } ::= { uas7626LocalAlarmConfigTable 1 } Uas7626LocalAlarmConfigEntry ::= SEQUENCE { uas7626LocalAlarmConfigIndex SCinstance, uas7626LossOfClockLocal INTEGER, uas7626ESLocal INTEGER, uas7626UASLocal INTEGER, uas7626OutofSyncLocal INTEGER, uas7626NoSealingCurrentLocal INTEGER } uas7626LocalAlarmConfigIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06)" ::= { uas7626LocalAlarmConfigEntry 1 } uas7626LossOfClockLocal OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMinor(2), enabledMajor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor Buss. Valid [i]nterface = 01-06" ::= { uas7626LocalAlarmConfigEntry 2 } uas7626ESLocal OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMinor(2), enabledMajor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor Buss. Valid [i]nterface = 01-06" ::= { uas7626LocalAlarmConfigEntry 3 } uas7626UASLocal OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMinor(2), enabledMajor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor Buss. Valid [i]nterface = 01-06" ::= { uas7626LocalAlarmConfigEntry 4 } uas7626OutofSyncLocal OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMinor(2), enabledMajor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor Buss. Valid [i]nterface = 01-06" ::= { uas7626LocalAlarmConfigEntry 5 } uas7626NoSealingCurrentLocal OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMinor(2), enabledMajor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor Buss. Valid [i]nterface = 01-06" ::= { uas7626LocalAlarmConfigEntry 6 } -- -- ******************************************************************** -- ATT Current Performance Table -- ******************************************************************** uas7626CurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF Uas7626CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The uas7626 Current table contains various statistics being collected for the current 15 minute interval." ::= { uas7626Performance 3 } uas7626CurrentEntry OBJECT-TYPE SYNTAX Uas7626CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the uas7626 Current table." INDEX { uas7626CurrentIndex } ::= { uas7626CurrentTable 1 } Uas7626CurrentEntry ::= SEQUENCE { uas7626CurrentIndex SCinstance, uas7626CurrentStat OCTET STRING } uas7626CurrentIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06)" ::= { uas7626CurrentEntry 1 } uas7626CurrentStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE(10)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise snapshot of the current 15 minute statistics: Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 3 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 4 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 5 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 6 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 8 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 9 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) Valid [i]nterface = 01-06" ::= {uas7626CurrentEntry 2 } -- -- ******************************************************************** -- ATT Interval Performance Table -- ******************************************************************** uas7626IntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Uas7626IntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The uas7626 Interval table contains various statistics collected by each Interface over the last 16 15-minute intervals." ::= { uas7626Performance 4 } uas7626IntervalEntry OBJECT-TYPE SYNTAX Uas7626IntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Interval table." INDEX { uas7626IntervalIndex, uas7626IntervalNumber } ::= { uas7626IntervalTable 1 } Uas7626IntervalEntry ::= SEQUENCE { uas7626IntervalIndex SCinstance, uas7626IntervalNumber INTEGER, uas7626IntervalStat OCTET STRING } uas7626IntervalIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06)" ::= { uas7626IntervalEntry 1 } uas7626IntervalNumber OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION "The interval number 1- 16. Valid [i]nterface = 01-06" ::= { uas7626IntervalEntry 2 } uas7626IntervalStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE(11)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise snapshot of the interval statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Interval Octet 3 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 4 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 5 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 6 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 7 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 8 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 9 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 10 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 11 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) Valid [i]nterface = 01-06" ::= {uas7626IntervalEntry 3 } -- -- ******************************************************************** -- ATT Total Performance Table -- ******************************************************************** uas7626TotalTable OBJECT-TYPE SYNTAX SEQUENCE OF Uas7626TotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The uas7626 Total Table contains the totals of the various statistics collected for the current 24 hour period for each interface." ::= { uas7626Performance 5 } uas7626TotalEntry OBJECT-TYPE SYNTAX Uas7626TotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the uas7626 Total table." INDEX { uas7626TotalIndex } ::= { uas7626TotalTable 1 } Uas7626TotalEntry ::= SEQUENCE { uas7626TotalIndex SCinstance, uas7626TotalStat OCTET STRING } uas7626TotalIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06)" ::= { uas7626TotalEntry 1 } uas7626TotalStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE(14)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise snapshot of the current 24 hour statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 3 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 4 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 5 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 6 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 8 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 9 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 11 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^23 bit 1 - 2^22 bit 0 - 2^21 Octet 12 bit 7 - not used bit 6 - 2^20 bit 5 - 2^19 bit 4 - 2^18 bit 3 - 2^17 bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 13 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 14 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) Valid [i]nterface = 01-06" ::= {uas7626TotalEntry 2 } -- -- ******************************************************************** -- GDC 7626 Recent 24 Hour Performance Table -- ******************************************************************** uas7626Recent24HrTable OBJECT-TYPE SYNTAX SEQUENCE OF Uas7626Recent24HrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Recent 24 Hour table contains the totals of the various statistics collected for the previous 24 hour period for each interface." ::= { uas7626Performance 6 } uas7626Recent24HrEntry OBJECT-TYPE SYNTAX Uas7626Recent24HrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Recent24Hr table." INDEX { uas7626Recent24HrIndex } ::= { uas7626Recent24HrTable 1 } Uas7626Recent24HrEntry ::= SEQUENCE { uas7626Recent24HrIndex SCinstance, uas7626Recent24HrStat OCTET STRING } uas7626Recent24HrIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06)" ::= { uas7626Recent24HrEntry 1 } uas7626Recent24HrStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE (14)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise snapshot of the recent 24 hour statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Loop ID Octet 2 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 3 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 4 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Errored Seconds Octet 5 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 6 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Severely Errored Seconds Octet 8 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - >65535 bit 1 - 2^15 bit 0 - 2^14 Octet 9 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Unavailable Seconds Octet 11 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - 2^23 bit 1 - 2^22 bit 0 - 2^21 Octet 12 bit 7 - not used bit 6 - 2^20 bit 5 - 2^19 bit 4 - 2^18 bit 3 - 2^17 bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 13 bit 7 - not used bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 14 bit 7 - not used bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 FEBE (Far End Block Error Count) Valid [i]nterface = 01-06" ::= {uas7626Recent24HrEntry 2 } -- -- ******************************************************************** -- GDC 7626 Unavailable Time Registers Table -- ******************************************************************** uas7626UnavailableTimeRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Uas7626UnavailableTimeRegEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The 7626 Unavailable Time Register table." ::= { uas7626Performance 7 } uas7626UnavailableTimeRegEntry OBJECT-TYPE SYNTAX Uas7626UnavailableTimeRegEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Unavailable Time Register table." INDEX {uas7626UnavailableTimeRegIndex,uas7626UnavailableTimeRegNumber} ::= { uas7626UnavailableTimeRegTable 1 } Uas7626UnavailableTimeRegEntry ::= SEQUENCE { uas7626UnavailableTimeRegIndex SCinstance, uas7626UnavailableTimeRegNumber INTEGER, uas7626UnavailableTimeRegStart INTEGER, uas7626UnavailableTimeRegStop INTEGER } uas7626UnavailableTimeRegIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the UAS7626 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - loop or interface number (00-06)" ::= { uas7626UnavailableTimeRegEntry 1 } uas7626UnavailableTimeRegNumber OBJECT-TYPE SYNTAX INTEGER (1..6) ACCESS read-only STATUS mandatory DESCRIPTION "A number between 1 and 6, where the number is the number of the Unavailable Time Register." ::= { uas7626UnavailableTimeRegEntry 2 } uas7626UnavailableTimeRegStart OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Start time of one of the Unavailable Time Registers." ::= { uas7626UnavailableTimeRegEntry 3 } uas7626UnavailableTimeRegStop OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Stop time of one of the Unavailable Time Registers." ::= { uas7626UnavailableTimeRegEntry 4 } -- **************************************************************************** -- mib definitions end -- **************************************************************************** END