| OID symbolic | OID numeric | Type | Access | Description |
| device | 1.3.6.1.4.1.3181.10.6.4 | | | Microsens private MIB for Generation 6 Ethernet Switches |
| smartoffice | 1.3.6.1.4.1.3181.10.6.4.99 | | | |
| INT smartofficeEnableSmartOffice | 1.3.6.1.4.1.3181.10.6.4.99.1 | INTEGER | read-write | Generally enable the SmartOffice solution. |
| directorConfigTable | 1.3.6.1.4.1.3181.10.6.4.99.2 | | not-accessible | General configuration of the director. |
| directorConfigEntry | 1.3.6.1.4.1.3181.10.6.4.99.2.1 | | not-accessible | |
| INT directorConfigIndex | 1.3.6.1.4.1.3181.10.6.4.99.2.1.1 | INTEGER | not-accessible | Automatically generated |
| STR directorConfigDomainName | 1.3.6.1.4.1.3181.10.6.4.99.2.1.2 | DisplayString | read-write | |
| INT directorConfigGeneralMode | 1.3.6.1.4.1.3181.10.6.4.99.2.1.3 | INTEGER | read-write | |
| INT directorConfigActOnUngroupedSensors | 1.3.6.1.4.1.3181.10.6.4.99.2.1.4 | INTEGER | read-write | When set any sensor attributes which are not configured to be part of a sensor group, will also trigger the regular script execution. This may be selected in smaller setups to save the effort of defining groups. Note that no event rate limiting can be applied to ungrouped sensors and thus using this mode can result in overloading the system leading to sluggish response times. |
| STR directorConfigScanLightControllers | 1.3.6.1.4.1.3181.10.6.4.99.2.1.5 | DisplayString | read-write | Scan the local network for reachable SmartLightController and display a list. |
| deviceConfigTable | 1.3.6.1.4.1.3181.10.6.4.99.3 | | not-accessible | Defines the configuration of each device under control. A device may contain one or more actor or sensor functions. |
| deviceConfigEntry | 1.3.6.1.4.1.3181.10.6.4.99.3.1 | | not-accessible | |
| INT deviceConfigIndex | 1.3.6.1.4.1.3181.10.6.4.99.3.1.1 | INTEGER | not-accessible | Automatically generated |
| STR deviceConfigDeviceName | 1.3.6.1.4.1.3181.10.6.4.99.3.1.2 | DisplayString | read-write | Unique group name referenced by the director |
| STR deviceConfigLocation | 1.3.6.1.4.1.3181.10.6.4.99.3.1.3 | DisplayString | read-write | Free text to describe the position of the controller on the premesis. This value need NOT be savedwithin the sensor itself. |
| STR deviceConfigLatitude | 1.3.6.1.4.1.3181.10.6.4.99.3.1.4 | DisplayString | read-write | A value in degrees such as: 50,123 |
| STR deviceConfigLongitude | 1.3.6.1.4.1.3181.10.6.4.99.3.1.5 | DisplayString | read-write | A value in degrees such as: 50,123 |
| STR deviceConfigAltitude | 1.3.6.1.4.1.3181.10.6.4.99.3.1.6 | DisplayString | read-write | A value in meters. |
| INT deviceConfigPlacement | 1.3.6.1.4.1.3181.10.6.4.99.3.1.7 | INTEGER | read-write | Information where to find the controller |
| INT deviceConfigProductType | 1.3.6.1.4.1.3181.10.6.4.99.3.1.8 | INTEGER | read-write | Defines via which network the sensor is reachable. |
| STR deviceConfigDeviceId | 1.3.6.1.4.1.3181.10.6.4.99.3.1.9 | DisplayString | read-write | Unique manufacturer dependent identifier of the device. For SmartLightController the MAC address of the controller is entered here. |
| STR deviceConfigNetworkAddress | 1.3.6.1.4.1.3181.10.6.4.99.3.1.10 | DisplayString | read-write | May be an IP or other type of address depending on the given network access method. Can be left blank for a SmartLightController. |
| STR deviceConfigAdditionalParameter | 1.3.6.1.4.1.3181.10.6.4.99.3.1.11 | DisplayString | read-write | Comma separated list of any parameter specific for this device. Example: panel=type A,refresh_rate=12 |
| INT deviceConfigNetworkFailureAction | 1.3.6.1.4.1.3181.10.6.4.99.3.1.12 | INTEGER | read-write | Defines what the actor does if the network connection fails or after reboot until communication is established. |
| STR deviceConfigIdentify | 1.3.6.1.4.1.3181.10.6.4.99.3.1.13 | DisplayString | read-write | The actor will blink with its status led to signal its presence and physical location. |
| STR deviceConfigRestart | 1.3.6.1.4.1.3181.10.6.4.99.3.1.14 | DisplayString | read-write | Restart the actor. |
| STR deviceConfigCalibrate | 1.3.6.1.4.1.3181.10.6.4.99.3.1.15 | DisplayString | read-write | Start calibration process (if available for this actor type). |
| STR deviceConfigPair | 1.3.6.1.4.1.3181.10.6.4.99.3.1.16 | DisplayString | read-write | Start pairing process that couples individual device to this director. |
| STR deviceConfigUnpair | 1.3.6.1.4.1.3181.10.6.4.99.3.1.17 | DisplayString | read-write | Discard exisiting pairing between an individual device and this director. |
| STR deviceConfigUpdateFirmware | 1.3.6.1.4.1.3181.10.6.4.99.3.1.18 | DisplayString | read-write | Update the device firmware. When no file name is supplied, the latest version is automatically selected. Alternatively, a specific file name can be supplied to use another version. Use Management.files.firmware.display_files to view a list of available files under the SLC section. (applies to SmartLight Controllers) |
| actorGroupConfigTable | 1.3.6.1.4.1.3181.10.6.4.99.4 | | not-accessible | Defines a group of actors that support the same attribute and which shall be set toghter to the same value. |
| actorGroupConfigEntry | 1.3.6.1.4.1.3181.10.6.4.99.4.1 | | not-accessible | |
| INT actorGroupConfigIndex | 1.3.6.1.4.1.3181.10.6.4.99.4.1.1 | INTEGER | not-accessible | Automatically generated |
| STR actorGroupConfigGroupName | 1.3.6.1.4.1.3181.10.6.4.99.4.1.2 | DisplayString | read-write | Unique group name referenced by the director |
| STR actorGroupConfigAttribute | 1.3.6.1.4.1.3181.10.6.4.99.4.1.3 | DisplayString | read-write | The attribute which is configured. Locally, identical attributes of the associated devices listed below are grouped. |
| STR actorGroupConfigAssociatedDevices | 1.3.6.1.4.1.3181.10.6.4.99.4.1.4 | DisplayString | read-write | List of all actors that supply information to a particular group. When an instance is used, here the syntax devicename.instance is used. All records are comma separated. |
| STR actorGroupConfigAdditionalParameter | 1.3.6.1.4.1.3181.10.6.4.99.4.1.5 | DisplayString | read-write | Comma separated list of any parameter specific for this attribute if needed. |
| STR actorGroupConfigDefaultValue | 1.3.6.1.4.1.3181.10.6.4.99.4.1.6 | DisplayString | read-write | |
| INT actorGroupConfigValueCaching | 1.3.6.1.4.1.3181.10.6.4.99.4.1.7 | INTEGER | read-write | When enabled the group target value is saved to local non volaive memory. Should the director restart, the cached values will be restored and send to the devices. This feature is useful to ensure uninterrupted operation even in the event of a system failure or to restore conditions after a power outage. |
| STR actorGroupConfigAdditionalScriptName | 1.3.6.1.4.1.3181.10.6.4.99.4.1.8 | DisplayString | read-write | When the actor group is updated, an additional script, defined here, can be executed to run time consuming functions outside of the standard processing loop. Usually, this field is left empty. |
| STR actorGroupConfigManualSetValue | 1.3.6.1.4.1.3181.10.6.4.99.4.1.9 | DisplayString | read-write | This command permits setting of the group value manually bypassing the defined script logic. This is intended for testing only. Important: This manual setting always acts on priority level 8. |
| sensorGroupConfigTable | 1.3.6.1.4.1.3181.10.6.4.99.5 | | not-accessible | Defines a group of sensors that support the same attribute and whose data should be interpreted together. |
| sensorGroupConfigEntry | 1.3.6.1.4.1.3181.10.6.4.99.5.1 | | not-accessible | |
| INT sensorGroupConfigIndex | 1.3.6.1.4.1.3181.10.6.4.99.5.1.1 | INTEGER | not-accessible | Automatically generated |
| STR sensorGroupConfigGroupName | 1.3.6.1.4.1.3181.10.6.4.99.5.1.2 | DisplayString | read-write | Unique group name referenced by the director |
| STR sensorGroupConfigAttribute | 1.3.6.1.4.1.3181.10.6.4.99.5.1.3 | DisplayString | read-write | The attribute which is configured. Locally, identical attributes of the associated devices listed below are grouped. |
| STR sensorGroupConfigAssociatedDevices | 1.3.6.1.4.1.3181.10.6.4.99.5.1.4 | DisplayString | read-write | List of all sensors that supply information to a particular group. When an instance is used, here the syntax devicename.instance is used. All records are comma separated. |
| INT sensorGroupConfigValueCaching | 1.3.6.1.4.1.3181.10.6.4.99.5.1.5 | INTEGER | read-write | When enabled the group target value is saved to local non volaive memory. Should the director restart, the cached values will be restored and send to the devices. This feature is useful to ensure uninterrupted operation even in the event of a system failure or to restore conditions after a power outage. |
| INT sensorGroupConfigRunScriptWhen | 1.3.6.1.4.1.3181.10.6.4.99.5.1.6 | INTEGER | read-write | Defines which sensor group status needs to change in order to run the standard (and optional additional_script). This can be used to limit the number of script runs by not following little changes that lead to no effect. This filter is logically behind the sensor specific limits defined elsewhere is this table. When the sensor filter is setup well, then this filter here can be relaxed. |
| STR sensorGroupConfigRunScriptDelta | 1.3.6.1.4.1.3181.10.6.4.99.5.1.7 | DisplayString | read-write | Defines how much the value can deviate before a value change is reported automatically. Depending on the setting of the report_mode an absolute or a percent value is expected. |
| STR sensorGroupConfigScriptName | 1.3.6.1.4.1.3181.10.6.4.99.5.1.8 | DisplayString | read-write | When the group is updated and the required conditions are met, the script specified in this parameter is executed. If the parameter is left blank, the standard MS_SmartOfficeControl.ms script is executed. The specified script should not contain any time consuming functions. Syntax: = appname/filename:subroutine The appname and subroutine name are optional. Without appname, the script must be located in xml_cli_scripts folder. |
| STR sensorGroupConfigAdditionalScriptName | 1.3.6.1.4.1.3181.10.6.4.99.5.1.9 | DisplayString | read-write | When the group is updated and the required conditions are met and a script is defined here, this script is executed in the background after the standard processing for this group has taken place. An additional script, defined here, can be used to run time consuming functions outside of the standard processing loop. Usually, this field is left empty. |
| INT sensorGroupConfigReportMode | 1.3.6.1.4.1.3181.10.6.4.99.5.1.10 | INTEGER | read-write | Defines if the sensor is passive or actively reports changes and error conditions |
| STR sensorGroupConfigAdditionalParameter | 1.3.6.1.4.1.3181.10.6.4.99.5.1.11 | DisplayString | read-write | Comma separated list of any parameter specific for this attribute if needed. |
| STR sensorGroupConfigLowerBoundary | 1.3.6.1.4.1.3181.10.6.4.99.5.1.12 | DisplayString | read-write | When the measured value of any sensor is equal or below this value an event is raised. The value may be configured directly with a numerical value optionally followed by a unit. |
| STR sensorGroupConfigUpperBoundary | 1.3.6.1.4.1.3181.10.6.4.99.5.1.13 | DisplayString | read-write | When the measured value of any sensor is equal or above this value an event is raised. The value may be configured directly with a numerical value optionally followed by a unit. |
| INT sensorGroupConfigBoundaryHysteresis | 1.3.6.1.4.1.3181.10.6.4.99.5.1.14 | INTEGER | read-write | How much the value must return within bounds before the alarm condition is cleared. |
| STR sensorGroupConfigUpdateDelta | 1.3.6.1.4.1.3181.10.6.4.99.5.1.15 | DisplayString | read-write | Defines how much the value can deviate before a value change is reported automatically. Depending on the setting of the report_mode an absolute or a percent value is expected. |
| U32 sensorGroupConfigRateLimit | 1.3.6.1.4.1.3181.10.6.4.99.5.1.16 | Unsigned32 | read-write | Defines how quickly the value is reported. Defined In units of 100ms. 0 means no rate limiting. |
| STR sensorGroupConfigClearValues | 1.3.6.1.4.1.3181.10.6.4.99.5.1.17 | DisplayString | read-write | Clear status values for minimum_peak_hold and maximum_peak_hold. |
| deviceInformationTable | 1.3.6.1.4.1.3181.10.6.4.99.100 | | not-accessible | Summarizes the most important inventory information of each detected device. |
| deviceInformationEntry | 1.3.6.1.4.1.3181.10.6.4.99.100.1 | | not-accessible | |
| INT deviceInformationIndex | 1.3.6.1.4.1.3181.10.6.4.99.100.1.1 | INTEGER | not-accessible | Automatically generated |
| STR deviceInformationName | 1.3.6.1.4.1.3181.10.6.4.99.100.1.2 | DisplayString | read-only | Unique name for reference. This is name of the base device. |
| STR deviceInformationHardwareId | 1.3.6.1.4.1.3181.10.6.4.99.100.1.3 | DisplayString | read-only | A product specific hardware identification. May for example contain the MAC address. |
| INT deviceInformationDeviceType | 1.3.6.1.4.1.3181.10.6.4.99.100.1.4 | INTEGER | read-only | Indicates if this is an actor or sensor device. |
| INT deviceInformationOperationalState | 1.3.6.1.4.1.3181.10.6.4.99.100.1.5 | INTEGER | read-only | Indicates the operational state of the device. Device (not attribute) specific errors will be indicated here. |
| STR deviceInformationActorAttributes | 1.3.6.1.4.1.3181.10.6.4.99.100.1.6 | DisplayString | read-only | Lists which setable actor attributes are provided by this device. |
| STR deviceInformationSensorAttributes | 1.3.6.1.4.1.3181.10.6.4.99.100.1.7 | DisplayString | read-only | Lists which readable sensor attributes are provided by this device. |
| STR deviceInformationVendorName | 1.3.6.1.4.1.3181.10.6.4.99.100.1.8 | DisplayString | read-only | Vendor or manufacturer name of the device. |
| STR deviceInformationArticleNumber | 1.3.6.1.4.1.3181.10.6.4.99.100.1.9 | DisplayString | read-only | This device article number. |
| STR deviceInformationSerialNumber | 1.3.6.1.4.1.3181.10.6.4.99.100.1.10 | DisplayString | read-only | This device serial number. |
| STR deviceInformationHardwareRevision | 1.3.6.1.4.1.3181.10.6.4.99.100.1.11 | DisplayString | read-only | This device hardware version. |
| STR deviceInformationSoftwareVersion | 1.3.6.1.4.1.3181.10.6.4.99.100.1.12 | DisplayString | read-only | This device software / firmware version. |
| STR deviceInformationAdditionalInfo | 1.3.6.1.4.1.3181.10.6.4.99.100.1.13 | DisplayString | read-only | Optional comma separated list of status fields specific for this type of device. |
| actorListTable | 1.3.6.1.4.1.3181.10.6.4.99.101 | | not-accessible | This table lists all currenly registered actors with all their attributes. |
| actorListEntry | 1.3.6.1.4.1.3181.10.6.4.99.101.1 | | not-accessible | |
| INT actorListIndex | 1.3.6.1.4.1.3181.10.6.4.99.101.1.1 | INTEGER | not-accessible | Automatically generated |
| STR actorListDevice | 1.3.6.1.4.1.3181.10.6.4.99.101.1.2 | DisplayString | read-only | This is name of the base device which controls this actor. There may be several actor types (attributes) in the same device and these share the same name but use different attributes. There may also be several similar actor attribues. These are differentiated with the instance parameter. |
| STR actorListInstance | 1.3.6.1.4.1.3181.10.6.4.99.101.1.3 | DisplayString | read-only | Describes a unique instance when several similar functional attributes are existing in the same device |
| STR actorListAttribute | 1.3.6.1.4.1.3181.10.6.4.99.101.1.4 | DisplayString | read-only | The kind of function this actor is acting on |
| STR actorListAssociatedGroups | 1.3.6.1.4.1.3181.10.6.4.99.101.1.5 | DisplayString | read-only | Indicates in which actor_groups this actor takes part. |
| STR actorListValue | 1.3.6.1.4.1.3181.10.6.4.99.101.1.6 | DisplayString | read-only | The currently set value as text string followed by the unit such as mA or Lux. |
| INT actorListActorState | 1.3.6.1.4.1.3181.10.6.4.99.101.1.7 | INTEGER | read-only | Indicates wether the indicated value was successfully written to the actual device. |
| C32 actorListLastUpdate | 1.3.6.1.4.1.3181.10.6.4.99.101.1.8 | Counter32 | read-only | Indicates the time when this record was last updated. |
| sensorListTable | 1.3.6.1.4.1.3181.10.6.4.99.102 | | not-accessible | This table lists all currenly registered sensors with all their attributes. |
| sensorListEntry | 1.3.6.1.4.1.3181.10.6.4.99.102.1 | | not-accessible | |
| INT sensorListIndex | 1.3.6.1.4.1.3181.10.6.4.99.102.1.1 | INTEGER | not-accessible | Automatically generated |
| STR sensorListDevice | 1.3.6.1.4.1.3181.10.6.4.99.102.1.2 | DisplayString | read-only | This is name of the base device which controls this sensor. There may be several different sensor types (attributes) in the same device. These share the same name but use different attributes. There may also be several similar sensors in the device. These are differentiated with the instance parameter. |
| STR sensorListInstance | 1.3.6.1.4.1.3181.10.6.4.99.102.1.3 | DisplayString | read-only | Describes a unique instance when several similar functional attributes are existing in the same device |
| STR sensorListAttribute | 1.3.6.1.4.1.3181.10.6.4.99.102.1.4 | DisplayString | read-only | The kind of measurement this sensor is reporting. |
| STR sensorListAssociatedGroups | 1.3.6.1.4.1.3181.10.6.4.99.102.1.5 | DisplayString | read-only | Indicates in which sensor_groups this sensor takes part. |
| STR sensorListValue | 1.3.6.1.4.1.3181.10.6.4.99.102.1.6 | DisplayString | read-only | The last reported value as text string followed by the unit such as mA or Lux. |
| INT sensorListSensorState | 1.3.6.1.4.1.3181.10.6.4.99.102.1.7 | INTEGER | read-only | Indicates particular sensor states such hitting a boundary. |
| C32 sensorListLastUpdate | 1.3.6.1.4.1.3181.10.6.4.99.102.1.8 | Counter32 | read-only | Indicates the time when this record was last updated. |
| actorGroupStatusTable | 1.3.6.1.4.1.3181.10.6.4.99.103 | | not-accessible | Calculated status of the defined actor groups. The listed value reflects the value all associated actors should use. The values update when an actor group is set by a script or manually. |
| actorGroupStatusEntry | 1.3.6.1.4.1.3181.10.6.4.99.103.1 | | not-accessible | |
| INT actorGroupStatusIndex | 1.3.6.1.4.1.3181.10.6.4.99.103.1.1 | INTEGER | not-accessible | Automatically generated |
| STR actorGroupStatusGroupName | 1.3.6.1.4.1.3181.10.6.4.99.103.1.2 | DisplayString | read-only | This is name mirrors the actor_group_configuration. |
| STR actorGroupStatusAttribute | 1.3.6.1.4.1.3181.10.6.4.99.103.1.3 | DisplayString | read-only | The name of the controlled attribute. |
| I32 actorGroupStatusNumAssignedActors | 1.3.6.1.4.1.3181.10.6.4.99.103.1.4 | Integer32 | read-only | Number of actors that are configured for this group. |
| I32 actorGroupStatusNumFailedActors | 1.3.6.1.4.1.3181.10.6.4.99.103.1.5 | Integer32 | read-only | Number of actors that have not responded as expected. |
| INT actorGroupStatusGroupState | 1.3.6.1.4.1.3181.10.6.4.99.103.1.6 | INTEGER | read-only | |
| STR actorGroupStatusValue | 1.3.6.1.4.1.3181.10.6.4.99.103.1.7 | DisplayString | read-only | This value is set by the decision logic. May contain simple on,OFF or for example a sound file name |
| U32 actorGroupStatusActivePriority | 1.3.6.1.4.1.3181.10.6.4.99.103.1.8 | Unsigned32 | read-only | Indicates which priority level is currently controlling the group value. Lower values have higher priority. |
| STR actorGroupStatusPriorityValueChain | 1.3.6.1.4.1.3181.10.6.4.99.103.1.9 | DisplayString | read-only | Displays the prority=value pairs of all currently defined priority levels. Relinquished priorites are not shown. |
| INT actorGroupStatusCacheStatus | 1.3.6.1.4.1.3181.10.6.4.99.103.1.10 | INTEGER | read-only | Indicates if this group_status is saved even upon system power loss or reboot. |
| C32 actorGroupStatusLastUpdate | 1.3.6.1.4.1.3181.10.6.4.99.103.1.11 | Counter32 | read-only | Indicates the time when this group status was last updated. |
| sensorGroupStatusTable | 1.3.6.1.4.1.3181.10.6.4.99.104 | | not-accessible | Calculated status for all sensor groups. The sensor values of all contributing sensors are used to calculate min, max and average values. The values update each time a sensor reports changes. |
| sensorGroupStatusEntry | 1.3.6.1.4.1.3181.10.6.4.99.104.1 | | not-accessible | |
| INT sensorGroupStatusIndex | 1.3.6.1.4.1.3181.10.6.4.99.104.1.1 | INTEGER | not-accessible | Automatically generated |
| STR sensorGroupStatusGroupName | 1.3.6.1.4.1.3181.10.6.4.99.104.1.2 | DisplayString | read-only | This is name mirrors the sensor_group_configuration. |
| STR sensorGroupStatusAttribute | 1.3.6.1.4.1.3181.10.6.4.99.104.1.3 | DisplayString | read-only | The name of the attribute measured. E.g. brightness, motion, switch. |
| I32 sensorGroupStatusNumAssignedSensors | 1.3.6.1.4.1.3181.10.6.4.99.104.1.4 | Integer32 | read-only | Number of sensors that are configured for this group. |
| I32 sensorGroupStatusNumFailedSensors | 1.3.6.1.4.1.3181.10.6.4.99.104.1.5 | Integer32 | read-only | Number of sensors that have not responded as expected. |
| INT sensorGroupStatusGroupState | 1.3.6.1.4.1.3181.10.6.4.99.104.1.6 | INTEGER | read-only | Informs when not all sensors operate as expected. |
| STR sensorGroupStatusMinimumPeakHold | 1.3.6.1.4.1.3181.10.6.4.99.104.1.7 | DisplayString | read-only | Minimum value ever reported in this group since last value clear. |
| STR sensorGroupStatusMinimumValue | 1.3.6.1.4.1.3181.10.6.4.99.104.1.8 | DisplayString | read-only | Minimum value out of all sensors that report to this group. |
| STR sensorGroupStatusAverageValue | 1.3.6.1.4.1.3181.10.6.4.99.104.1.9 | DisplayString | read-only | Average value out of all sensors that report to this group. Uses the number of reporting sensors to calculate the average. |
| STR sensorGroupStatusMaximumValue | 1.3.6.1.4.1.3181.10.6.4.99.104.1.10 | DisplayString | read-only | Maximum value out of all sensors that report to this group. |
| STR sensorGroupStatusMaximumPeakHold | 1.3.6.1.4.1.3181.10.6.4.99.104.1.11 | DisplayString | read-only | Maximum value ever reported in this group since last value clear. |
| STR sensorGroupStatusTotalValue | 1.3.6.1.4.1.3181.10.6.4.99.104.1.12 | DisplayString | read-only | The total sum of all individual sensor values in this group. |
| I32 sensorGroupStatusLowerBoundaryReached | 1.3.6.1.4.1.3181.10.6.4.99.104.1.13 | Integer32 | read-only | Number of sensors that have reached their lower threshold. A value of 0 means no sensor has reached a lower boundary. |
| I32 sensorGroupStatusUpperBoundaryReached | 1.3.6.1.4.1.3181.10.6.4.99.104.1.14 | Integer32 | read-only | Number of sensors that have reached their upper threshold. A value of 0 means no sensor has reached an upper boundary. |
| I32 sensorGroupStatusUpdatingSensorIndex | 1.3.6.1.4.1.3181.10.6.4.99.104.1.15 | Integer32 | read-only | Indicates the index to the sensor_list which has caused the latest group update. |
| INT sensorGroupStatusCacheStatus | 1.3.6.1.4.1.3181.10.6.4.99.104.1.16 | INTEGER | read-only | Indicates if this attribute is saved even upon system power loss or reboot. |
| C32 sensorGroupStatusLastUpdate | 1.3.6.1.4.1.3181.10.6.4.99.104.1.17 | Counter32 | read-only | Indicates the time when this group status was last updated. |