G6-SMARTOFFICE-MIB :: sensorGroupConfigRunScriptWhen

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › G6-SMARTOFFICE-MIB › sensorGroupConfigRunScriptWhen

sensorGroupConfigRunScriptWhen

Module: G6-SMARTOFFICE-MIB

OID (symbolic): G6-SMARTOFFICE-MIB::sensorGroupConfigRunScriptWhen

OID (numeric): 1.3.6.1.4.1.3181.10.6.4.99.5.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Defines which sensor group status needs to change in order to run the standard (and optional additional_script). This can be used to limit the number of script runs by not following little changes that lead to no effect. This filter is logically behind the sensor specific limits defined elsewhere is this table. When the sensor filter is setup well, then this filter here can be relaxed.

What is sensorGroupConfigRunScriptWhen?

Defines which kind of change in this sensor group's status is needed to trigger the standard (and optional additional) script, e.g. any change, a limit crossing, a percent/absolute average or total change, a new peak, or zero-crossing, per its DESCRIPTION. Admins relax this filter (e.g. to 'limitCrossed' only) to cut down on unnecessary script runs when the per-sensor filters are already well-tuned.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.4.99.5.1.6
snmpwalk -v2c -c public <target> G6-SMARTOFFICE-MIB::sensorGroupConfigRunScriptWhen

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.4.99.5.1.6.1
snmpget -v2c -c public <target> G6-SMARTOFFICE-MIB::sensorGroupConfigRunScriptWhen.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.3181.10.6.4.99.5.1.6.1 i <value>

Start monitoring MICROSENS Generation 6 (G6) managed Ethernet switch (SmartOffice building-automation feature) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the G6-SMARTOFFICE-MIB::sensorGroupConfigRunScriptWhen OID value, configure state conditions and alerts, and monitor any MICROSENS Generation 6 (G6) managed Ethernet switch (SmartOffice building-automation feature) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3181microsensMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10managedSwitchesMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10.6g6MICROSENS-G6-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3181.10.6.4deviceG6-SMARTOFFICE-MIB
1.3.6.1.4.1.3181.10.6.4.99smartofficeG6-SMARTOFFICE-MIB
1.3.6.1.4.1.3181.10.6.4.99.5sensorGroupConfigTableG6-SMARTOFFICE-MIB
1.3.6.1.4.1.3181.10.6.4.99.5.1sensorGroupConfigEntryG6-SMARTOFFICE-MIB
1.3.6.1.4.1.3181.10.6.4.99.5.1.6sensorGroupConfigRunScriptWhenG6-SMARTOFFICE-MIB