G6-SMARTOFFICE-MIB :: sensorGroupConfigScriptName

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › G6-SMARTOFFICE-MIB › sensorGroupConfigScriptName

sensorGroupConfigScriptName

Module: G6-SMARTOFFICE-MIB

OID (symbolic): G6-SMARTOFFICE-MIB::sensorGroupConfigScriptName

OID (numeric): 1.3.6.1.4.1.3181.10.6.4.99.5.1.8

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

Description: When the group is updated and the required conditions are met, the script specified in this parameter is executed. If the parameter is left blank, the standard MS_SmartOfficeControl.ms script is executed. The specified script should not contain any time consuming functions. Syntax: = appname/filename:subroutine The appname and subroutine name are optional. Without appname, the script must be located in xml_cli_scripts folder.

What is sensorGroupConfigScriptName?

Names the script executed when this sensor group updates and its trigger conditions are met, defaulting to MS_SmartOfficeControl.ms if left blank, using an appname/filename:subroutine syntax, per its DESCRIPTION. Admins point this at a custom automation script instead of the default when they want bespoke logic for this specific sensor group.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.4.99.5.1.8
snmpwalk -v2c -c public <target> G6-SMARTOFFICE-MIB::sensorGroupConfigScriptName

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.4.99.5.1.8.1
snmpget -v2c -c public <target> G6-SMARTOFFICE-MIB::sensorGroupConfigScriptName.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.3181.10.6.4.99.5.1.8.1 s <value>

Start monitoring MICROSENS Generation 6 (G6) managed Ethernet switch (SmartOffice building-automation feature) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the G6-SMARTOFFICE-MIB::sensorGroupConfigScriptName OID value, configure state conditions and alerts, and monitor any MICROSENS Generation 6 (G6) managed Ethernet switch (SmartOffice building-automation feature) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3181microsensMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10managedSwitchesMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10.6g6MICROSENS-G6-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3181.10.6.4deviceG6-SMARTOFFICE-MIB
1.3.6.1.4.1.3181.10.6.4.99smartofficeG6-SMARTOFFICE-MIB
1.3.6.1.4.1.3181.10.6.4.99.5sensorGroupConfigTableG6-SMARTOFFICE-MIB
1.3.6.1.4.1.3181.10.6.4.99.5.1sensorGroupConfigEntryG6-SMARTOFFICE-MIB
1.3.6.1.4.1.3181.10.6.4.99.5.1.8sensorGroupConfigScriptNameG6-SMARTOFFICE-MIB