directorConfigActOnUngroupedSensors

Module: G6-SMARTOFFICE-MIB

OID (symbolic): G6-SMARTOFFICE-MIB::directorConfigActOnUngroupedSensors

OID (numeric): 1.3.6.1.4.1.3181.10.6.4.99.2.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: When set any sensor attributes which are not configured to be part of a sensor group, will also trigger the regular script execution. This may be selected in smaller setups to save the effort of defining groups. Note that no event rate limiting can be applied to ungrouped sensors and thus using this mode can result in overloading the system leading to sluggish response times.

What is directorConfigActOnUngroupedSensors?

When enabled, sensor attributes not assigned to any sensor group still trigger script execution, per its DESCRIPTION, which is convenient in small setups but disables event rate limiting and can overload the system with too many script runs. Admins should only enable this in small deployments, since the DESCRIPTION explicitly warns it can cause sluggish response times if used at scale.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.4.99.2.1.4
snmpwalk -v2c -c public <target> G6-SMARTOFFICE-MIB::directorConfigActOnUngroupedSensors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.4.99.2.1.4.1
snmpget -v2c -c public <target> G6-SMARTOFFICE-MIB::directorConfigActOnUngroupedSensors.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.3181.10.6.4.99.2.1.4.1 i <value>

Start monitoring MICROSENS Generation 6 (G6) managed Ethernet switch (SmartOffice building-automation feature) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the G6-SMARTOFFICE-MIB::directorConfigActOnUngroupedSensors OID value, configure state conditions and alerts, and monitor any MICROSENS Generation 6 (G6) managed Ethernet switch (SmartOffice building-automation feature) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3181microsensMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10managedSwitchesMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10.6g6MICROSENS-G6-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3181.10.6.4deviceG6-SMARTOFFICE-MIB
1.3.6.1.4.1.3181.10.6.4.99smartofficeG6-SMARTOFFICE-MIB
1.3.6.1.4.1.3181.10.6.4.99.2directorConfigTableG6-SMARTOFFICE-MIB
1.3.6.1.4.1.3181.10.6.4.99.2.1directorConfigEntryG6-SMARTOFFICE-MIB
1.3.6.1.4.1.3181.10.6.4.99.2.1.4directorConfigActOnUngroupedSensorsG6-SMARTOFFICE-MIB