| OID symbolic | OID numeric | Type | Access | Description |
| eriRouterPvcMib | 1.3.6.1.4.1.193.218.2.7 | | | Defines the objects necessary to support the management of
ATM, Frame Relay and IEEE 802.1Q permanent virtual circuits
(PVC). |
| eriRouterPvcMIBObjects | 1.3.6.1.4.1.193.218.2.7.1 | | | |
| eriRouterAtmPvcConfigTable | 1.3.6.1.4.1.193.218.2.7.1.1 | | not-accessible | This table contains the objects which identify and configure
ATM PVCs. |
| eriRouterAtmPvcConfigEntry | 1.3.6.1.4.1.193.218.2.7.1.1.1 | | not-accessible | A conceptual row in the eriRouterAtmPvcConfigTable. |
| ERI eriRouterAtmPvcSlot | 1.3.6.1.4.1.193.218.2.7.1.1.1.1 | EriRouterSlot | not-accessible | The chassis slot number |
| ERI eriRouterAtmPvcPort | 1.3.6.1.4.1.193.218.2.7.1.1.1.2 | EriRouterPort | not-accessible | The port number |
| U32 eriRouterAtmPvcVpi | 1.3.6.1.4.1.193.218.2.7.1.1.1.3 | Unsigned32 | not-accessible | The Virtual Path Identifier for the PVC. |
| U32 eriRouterAtmPvcVci | 1.3.6.1.4.1.193.218.2.7.1.1.1.4 | Unsigned32 | not-accessible | The Virtual Channel Identifier for the PVC. |
| STR eriRouterAtmPvcProfileName | 1.3.6.1.4.1.193.218.2.7.1.1.1.5 | SnmpAdminString | read-create | The profile name to use with the PVC. |
| ERI eriRouterAtmPvcEncapsulation | 1.3.6.1.4.1.193.218.2.7.1.1.1.6 | EriRouterAtmEncapsulation | read-create | The encapsulation to use with the PVC. |
| ROW eriRouterAtmPvcRowStatus | 1.3.6.1.4.1.193.218.2.7.1.1.1.8 | RowStatus | read-create | The row status for creating, modifying, or deleting an entry
in the table. |
| ERI eriRouterAtmPvcCircuitType | 1.3.6.1.4.1.193.218.2.7.1.1.1.9 | EriRouterPvcCircuitType | read-create | The PVC circuit type. With respect to this mib
object, only those entries whose eriRouterAtmPvcCircuitType
has a value 'explicit' may be removed by setting
eriRouterAtmPvcRowStatus equal to 'destroy'. A set
operation with eriRouterAtmPvcRowStatus equal to 'destroy'
on any row with eriRouterAtmPvcCircuitType not equal to
'explicit' will result in an INCONSISTENT_VALUE_ERROR. |
| ERI eriRouterAtmPvcCircuitHandle | 1.3.6.1.4.1.193.218.2.7.1.1.1.10 | EriRouterCircuitHandle | read-only | This object is used internally to uniquely identify
a circuit. The value of this object may be used to
correlate entries with those in the eriRouterBindTable defined
in the ERICSSON-ROUTER-BIND-MIB. |
| T/F eriRouterAtmPvcClearCircuit | 1.3.6.1.4.1.193.218.2.7.1.1.1.11 | TruthValue | read-create | When this object is true(1), the system will clear active
subscriber sessions on the specified circuit. When false(2),
there is no action taken. This object can only be written
when the conceptual row exists.
When this object is set to true(1) and the encapsulation
of the circuit is bridged or routed, e.g. bridge1483(2) or
route1483(4), subscribers will re-authenticate after
being cleared. |
| eriRouterFrameRelayPvcConfigTable | 1.3.6.1.4.1.193.218.2.7.1.2 | | not-accessible | This table contains the objects which identify and configure
Frame Relay PVCs. |
| eriRouterFrameRelayPvcConfigEntry | 1.3.6.1.4.1.193.218.2.7.1.2.1 | | not-accessible | A conceptual row in the eriRouterFrameRelayPvcConfigTable. |
| ERI eriRouterFrameRelayPvcSlot | 1.3.6.1.4.1.193.218.2.7.1.2.1.1 | EriRouterSlot | not-accessible | The chassis slot number |
| ERI eriRouterFrameRelayPvcPort | 1.3.6.1.4.1.193.218.2.7.1.2.1.2 | EriRouterPort | not-accessible | The port number |
| U32 eriRouterFrameRelayPvcChannel | 1.3.6.1.4.1.193.218.2.7.1.2.1.3 | Unsigned32 | not-accessible | The channel number |
| U32 eriRouterFrameRelayPvcDLCI | 1.3.6.1.4.1.193.218.2.7.1.2.1.4 | Unsigned32 | not-accessible | The Data Link Connection Identifier |
| STR eriRouterFrameRelayPvcProfileName | 1.3.6.1.4.1.193.218.2.7.1.2.1.5 | SnmpAdminString | read-create | The profile name to use with the PVC. |
| ERI eriRouterFrameRelayPvcEncapsulation | 1.3.6.1.4.1.193.218.2.7.1.2.1.6 | EriRouterFrameRelayEncapsulation | read-create | The encapsulation to use with the PVC. |
| ROW eriRouterFrameRelayPvcRowStatus | 1.3.6.1.4.1.193.218.2.7.1.2.1.8 | RowStatus | read-create | The row status for creating, modifying, or deleting an entry
in the table. |
| ERI eriRouterFrameRelayPvcCircuitType | 1.3.6.1.4.1.193.218.2.7.1.2.1.9 | EriRouterPvcCircuitType | read-create | The PVC circuit type. With respect to this mib
object, only those entries whose eriRouterFrameRelayPvcCircuitType
has a value 'explicit' may be removed by setting
eriRouterFrameRelayPvcRowStatus equal to 'destroy'. A set
operation with eriRouterFrameRelayPvcRowStatus equal to 'destroy'
on any row with eriRouterFrameRelayPvcCircuitType not equal to
'explicit' will result in an INCONSISTENT_VALUE_ERROR. |
| ERI eriRouterFrameRelayPvcCircuitHandle | 1.3.6.1.4.1.193.218.2.7.1.2.1.10 | EriRouterCircuitHandle | read-only | This object is used internally to uniquely identify
a circuit. The value of this object may be used to
correlate entries with those in the eriRouterBindTable defined
in the ERICSSON-ROUTER-BIND-MIB. |
| T/F eriRouterFrameRelayPvcClearCircuit | 1.3.6.1.4.1.193.218.2.7.1.2.1.11 | TruthValue | read-create | When this object is true(1), the system will clear active
subscriber sessions on the specified circuit. When false(2),
there is no action taken. This object can only be written
when the conceptual row exists.
When this object is set to true(1) and the encapsulation
of the circuit is bridged or routed, e.g. bridge1490(2) or
route1490(4), subscribers will re-authenticate after
being cleared. |
| eriRouterDot1qPvcOnEthConfigTable | 1.3.6.1.4.1.193.218.2.7.1.3 | | not-accessible | This table contains the objects which identify and configure
IEEE 802.1Q PVCs on Ethernet ports. |
| eriRouterDot1qPvcOnEthConfigEntry | 1.3.6.1.4.1.193.218.2.7.1.3.1 | | not-accessible | A conceptual row in the eriRouterDot1qPvcOnEthConfigTable. |
| ERI eriRouterDot1qPvcOnEthSlot | 1.3.6.1.4.1.193.218.2.7.1.3.1.1 | EriRouterSlot | not-accessible | The chassis slot number. |
| ERI eriRouterDot1qPvcOnEthPort | 1.3.6.1.4.1.193.218.2.7.1.3.1.2 | EriRouterPort | not-accessible | The port number. |
| ERI eriRouterDot1qPvcOnEthVlanId | 1.3.6.1.4.1.193.218.2.7.1.3.1.3 | EriRouterVidOrUntagged | not-accessible | IEEE 802.1Q Virtual LAN (VLAN) tag value. |
| ROW eriRouterDot1qPvcOnEthRowStatus | 1.3.6.1.4.1.193.218.2.7.1.3.1.4 | RowStatus | read-create | The row status for creating, modifying, or deleting an entry
in the table. |
| STR eriRouterDot1qPvcOnEthProfileName | 1.3.6.1.4.1.193.218.2.7.1.3.1.5 | SnmpAdminString | read-create | The profile name to use with the PVC. |
| ERI eriRouterDot1qPvcOnEthEncapsulation | 1.3.6.1.4.1.193.218.2.7.1.3.1.6 | EriRouterDot1qEncapsulation | read-create | The encapsulation to use with the PVC. |
| ERI eriRouterDot1qPvcOnEthCircuitType | 1.3.6.1.4.1.193.218.2.7.1.3.1.7 | EriRouterPvcCircuitType | read-create | The PVC circuit type. With respect to this mib object,
only those entries whose eriRouterDot1qPvcOnEthCircuitType
has a value 'explicit' may be removed by setting
eriRouterDot1qPvcOnEthRowStatus equal to 'destroy'. A set
operation with eriRouterDot1qPvcOnEthRowStatus equal to 'destroy'
on any row with eriRouterDot1qPvcOnEthCircuitType not equal to
'explicit' will result in an INCONSISTENT_VALUE_ERROR. |
| ERI eriRouterDot1qPvcOnEthCircuitHandle | 1.3.6.1.4.1.193.218.2.7.1.3.1.8 | EriRouterCircuitHandle | read-only | This object is used internally to uniquely identify
a circuit. The value of this object may be used to
correlate entries with those in the eriRouterBindTable defined
in the ERICSSON-ROUTER-BIND-MIB. |
| T/F eriRouterDot1qPvcOnEthClearCircuit | 1.3.6.1.4.1.193.218.2.7.1.3.1.9 | TruthValue | read-create | When this object is true(1), the system will clear active
subscriber sessions on the specified circuit. When false(2),
there is no action taken. This object can only be written
when the conceptual row exists. |
| eriRouterDot1qPvcOnAtmConfigTable | 1.3.6.1.4.1.193.218.2.7.1.4 | | not-accessible | This table contains the objects which identify and configure
IEEE 802.1Q PVCs on ATM circuits. |
| eriRouterDot1qPvcOnAtmConfigEntry | 1.3.6.1.4.1.193.218.2.7.1.4.1 | | not-accessible | A conceptual row in the eriRouterDot1qPvcOnAtmConfigTable. |
| ERI eriRouterDot1qPvcOnAtmSlot | 1.3.6.1.4.1.193.218.2.7.1.4.1.1 | EriRouterSlot | not-accessible | The chassis slot number. |
| ERI eriRouterDot1qPvcOnAtmPort | 1.3.6.1.4.1.193.218.2.7.1.4.1.2 | EriRouterPort | not-accessible | The port number. |
| U32 eriRouterDot1qPvcOnAtmVpi | 1.3.6.1.4.1.193.218.2.7.1.4.1.3 | Unsigned32 | not-accessible | The Virtual Path Identifier for the PVC. |
| U32 eriRouterDot1qPvcOnAtmVci | 1.3.6.1.4.1.193.218.2.7.1.4.1.4 | Unsigned32 | not-accessible | The Virtual Channel Identifier for the PVC. |
| ERI eriRouterDot1qPvcOnAtmVlanId | 1.3.6.1.4.1.193.218.2.7.1.4.1.5 | EriRouterVidOrUntagged | not-accessible | IEEE 802.1Q Virtual LAN (VLAN) tag value. |
| ROW eriRouterDot1qPvcOnAtmRowStatus | 1.3.6.1.4.1.193.218.2.7.1.4.1.6 | RowStatus | read-create | The row status for creating, modifying, or deleting an entry
in the table. |
| STR eriRouterDot1qPvcOnAtmProfileName | 1.3.6.1.4.1.193.218.2.7.1.4.1.7 | SnmpAdminString | read-create | The profile name to use with the PVC. |
| ERI eriRouterDot1qPvcOnAtmEncapsulation | 1.3.6.1.4.1.193.218.2.7.1.4.1.8 | EriRouterDot1qEncapsulation | read-create | The encapsulation to use with the PVC. |
| ERI eriRouterDot1qPvcOnAtmCircuitType | 1.3.6.1.4.1.193.218.2.7.1.4.1.9 | EriRouterPvcCircuitType | read-create | The PVC circuit type. With respect to this mib object,
only those entries whose eriRouterDot1qPvcOnAtmCircuitType
has a value 'explicit' may be removed by setting
eriRouterDot1qPvcOnAtmRowStatus equal to 'destroy'. A set
operation with eriRouterDot1qPvcOnAtmRowStatus equal to 'destroy'
on any row with eriRouterDot1qPvcOnAtmCircuitType not equal to
'explicit' will result in an INCONSISTENT_VALUE_ERROR. |
| ERI eriRouterDot1qPvcOnAtmCircuitHandle | 1.3.6.1.4.1.193.218.2.7.1.4.1.10 | EriRouterCircuitHandle | read-only | This object is used internally to uniquely identify
a circuit. The value of this object may be used to
correlate entries with those in the eriRouterBindTable defined
in the ERICSSON-ROUTER-BIND-MIB. |
| T/F eriRouterDot1qPvcOnAtmClearCircuit | 1.3.6.1.4.1.193.218.2.7.1.4.1.11 | TruthValue | read-create | When this object is true(1), the system will clear active
subscriber sessions on the specified circuit. When false(2),
there is no action taken. This object can only be written
when the conceptual row exists. |
| eriRouterDot1qPvcOnFrConfigTable | 1.3.6.1.4.1.193.218.2.7.1.5 | | not-accessible | This table contains the objects which identify and configure
IEEE 802.1Q PVCs on ATM circuits. |
| eriRouterDot1qPvcOnFrConfigEntry | 1.3.6.1.4.1.193.218.2.7.1.5.1 | | not-accessible | A conceptual row in the eriRouterDot1qPvcOnFrConfigTable. |
| ERI eriRouterDot1qPvcOnFrSlot | 1.3.6.1.4.1.193.218.2.7.1.5.1.1 | EriRouterSlot | not-accessible | The chassis slot number. |
| ERI eriRouterDot1qPvcOnFrPort | 1.3.6.1.4.1.193.218.2.7.1.5.1.2 | EriRouterPort | not-accessible | The port number. |
| U32 eriRouterDot1qPvcOnFrChannel | 1.3.6.1.4.1.193.218.2.7.1.5.1.3 | Unsigned32 | not-accessible | The channel number. |
| U32 eriRouterDot1qPvcOnFrDLCI | 1.3.6.1.4.1.193.218.2.7.1.5.1.4 | Unsigned32 | not-accessible | The Data Link Connection Identifier. |
| ERI eriRouterDot1qPvcOnFrVlanId | 1.3.6.1.4.1.193.218.2.7.1.5.1.5 | EriRouterVidOrUntagged | not-accessible | IEEE 802.1Q Virtual LAN (VLAN) tag value. |
| ROW eriRouterDot1qPvcOnFrRowStatus | 1.3.6.1.4.1.193.218.2.7.1.5.1.6 | RowStatus | read-create | The row status for creating, modifying, or deleting an entry
in the table. |
| STR eriRouterDot1qPvcOnFrProfileName | 1.3.6.1.4.1.193.218.2.7.1.5.1.7 | SnmpAdminString | read-create | The profile name to use with the PVC. |
| ERI eriRouterDot1qPvcOnFrEncapsulation | 1.3.6.1.4.1.193.218.2.7.1.5.1.8 | EriRouterDot1qEncapsulation | read-create | The encapsulation to use with the PVC. |
| ERI eriRouterDot1qPvcOnFrCircuitType | 1.3.6.1.4.1.193.218.2.7.1.5.1.9 | EriRouterPvcCircuitType | read-create | The PVC circuit type. With respect to this mib object,
only those entries whose eriRouterDot1qPvcOnFrCircuitType
has a value 'explicit' may be removed by setting
eriRouterDot1qPvcOnFrRowStatus equal to 'destroy'. A set
operation with eriRouterDot1qPvcOnFrRowStatus equal to 'destroy'
on any row with eriRouterDot1qPvcOnFrCircuitType not equal to
'explicit' will result in an INCONSISTENT_VALUE_ERROR. |
| ERI eriRouterDot1qPvcOnFrCircuitHandle | 1.3.6.1.4.1.193.218.2.7.1.5.1.10 | EriRouterCircuitHandle | read-only | This object is used internally to uniquely identify
a circuit. The value of this object may be used to
correlate entries with those in the eriRouterBindTable defined
in the ERICSSON-ROUTER-BIND-MIB. |
| T/F eriRouterDot1qPvcOnFrClearCircuit | 1.3.6.1.4.1.193.218.2.7.1.5.1.11 | TruthValue | read-create | When this object is true(1), the system will clear active
subscriber sessions on the specified circuit. When false(2),
there is no action taken. This object can only be written
when the conceptual row exists. |
| eriRouterPvcMIBConformance | 1.3.6.1.4.1.193.218.2.7.2 | | | |
| eriRouterPvcCompliances | 1.3.6.1.4.1.193.218.2.7.2.1 | | | |
| eriRouterPvcCompliance | 1.3.6.1.4.1.193.218.2.7.2.1.1 | | | The compliance statement for SNMP entities which implement
the ERICSSON-ROUTER-PVC-MIB. |
| eriRouterPvcCompliance2 | 1.3.6.1.4.1.193.218.2.7.2.1.2 | | | The compliance statement for SNMP entities which implement
the ERICSSON-ROUTER-PVC-MIB. |
| eriRouterPvcCompliance3 | 1.3.6.1.4.1.193.218.2.7.2.1.3 | | | The compliance statement for SNMP entities which implement
the ERICSSON-ROUTER-PVC-MIB. |
| eriRouterPvcGroups | 1.3.6.1.4.1.193.218.2.7.2.2 | | | |
| eriRouterAtmPvcGroup | 1.3.6.1.4.1.193.218.2.7.2.2.1 | | | the collection of objects which represent the ATM PVC. |
| eriRouterFrameRelayPvcGroup | 1.3.6.1.4.1.193.218.2.7.2.2.2 | | | the collection of objects which represent the FrameRelay PVC. |
| eriRouterAtmPvcGroup2 | 1.3.6.1.4.1.193.218.2.7.2.2.3 | | | The collection of objects which represent the ATM PVC. |
| eriRouterFrameRelayPvcGroup2 | 1.3.6.1.4.1.193.218.2.7.2.2.4 | | | The collection of objects which represent the FrameRelay PVC. |
| eriRouterDot1qPvcOnEthGroup | 1.3.6.1.4.1.193.218.2.7.2.2.5 | | | A collection of objects providing information specific
to IEEE 802.1Q PVCs on Ethernet ports. |
| eriRouterDot1qPvcOnAtmGroup | 1.3.6.1.4.1.193.218.2.7.2.2.6 | | | A collection of objects providing information specific
to IEEE 802.1Q PVCs on ATM circuits. |
| eriRouterDot1qPvcOnFrGroup | 1.3.6.1.4.1.193.218.2.7.2.2.7 | | | A collection of objects providing information specific
to IEEE 802.1Q PVCs on Frame Relay circuits. |
| eriRouterPvcMIBNotifications | 1.3.6.1.4.1.193.218.2.7.3 | | | |