All MIBs › ERICSSON-ROUTER-PVC-MIB › eriRouterAtmPvcClearCircuit
eriRouterAtmPvcClearCircuit
Module: ERICSSON-ROUTER-PVC-MIB
OID (symbolic): ERICSSON-ROUTER-PVC-MIB::eriRouterAtmPvcClearCircuit
OID (numeric): 1.3.6.1.4.1.193.218.2.7.1.1.1.11
Node type: OBJECT-TYPE
Type: TruthValue
Access: read-create
Description: When this object is true(1), the system will clear active subscriber sessions on the specified circuit. When false(2), there is no action taken. This object can only be written when the conceptual row exists.
When this object is set to true(1) and the encapsulation of the circuit is bridged or routed, e.g. bridge1483(2) or route1483(4), subscribers will re-authenticate after being cleared.
What is eriRouterAtmPvcClearCircuit?
Setting this to true(1) forces the router to drop any active subscriber sessions on this ATM PVC without deleting the circuit itself, useful for kicking a hung DSL subscriber off without reconfiguring the VPI/VCI. If the PVC's encapsulation is bridged or routed (e.g. bridge1483 or route1483), the client will automatically re-authenticate after being cleared.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.193 | ericsson | ANS-COMMON-MIB |
| 1.3.6.1.4.1.193.218 | eriRouterSMI | ERICSSON-ROUTER-SMI |
| 1.3.6.1.4.1.193.218.2 | eriRouterMgmt | ERICSSON-ROUTER-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.193.218.2.7 | eriRouterPvcMib | ERICSSON-ROUTER-PVC-MIB |
| 1.3.6.1.4.1.193.218.2.7.1 | eriRouterPvcMIBObjects | ERICSSON-ROUTER-PVC-MIB |
| 1.3.6.1.4.1.193.218.2.7.1.1 | eriRouterAtmPvcConfigTable | ERICSSON-ROUTER-PVC-MIB |
| 1.3.6.1.4.1.193.218.2.7.1.1.1 | eriRouterAtmPvcConfigEntry | ERICSSON-ROUTER-PVC-MIB |
| 1.3.6.1.4.1.193.218.2.7.1.1.1.11 | eriRouterAtmPvcClearCircuit | ERICSSON-ROUTER-PVC-MIB |