All MIBs › CPQHSV110V3-MIB › sCellEventTrapD47
sCellEventTrapD47
Module: CPQHSV110V3-MIB
OID (symbolic): CPQHSV110V3-MIB::sCellEventTrapD47
OID (numeric): 1.3.6.1.4.1.232.0.13603399
Node type: NOTIFICATION-TYPE
Description: Severity: Critical -- failure or failure imminent. A drive enclosure blower is not operating properly. This could affect the drive enclosure air flow and cause an over temperature condition. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the denclNum field as follows:
- If denclNum is less than 99, the location is as indicated by the content of the rackNum and denclNum fields.
- If denclNum is equal to 99, the location is unknown. Note that the content of the rackNum field is undefined in this case.
- If denclNum is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rackNum and denclNum fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate.
- 1 = The blower is operating at a speed that is outside of the Drive Enclosure Environmental Monitoring Unit specified range, possibly because of a bearing problem.
- 2 = The blower is operating at a speed that is significantly outside of the Drive Enclosure Environmental Monitoring Unit specified range, possibly because of a bearing problem.
- 3 = The blower has stopped. NOTE: The other blower (if operational) now operates at high speed and is a single point of failure. A single blower operating at high speed can provide sufficient air flow to cool an enclosure and the elements for up to 100 hours. However, operating an enclosure at temperatures approaching an overheating threshold can damage elements and may reduce the MTBF of a specific element. Hewlett-Packard therefore recommends immediate replacement of the defective blower.
- 4 = The power supply reported an internal blower error.
The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.denclNum field as follows:
- If enclosures.denclNum is less than 99, the location is as indicated by the content of the enclosures.rackNum and enclosures.denclNum fields.
- If enclosures.denclNum is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rackNum field is undefined in this case.
- If enclosures.denclNum is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rackNum and enclosures.denclNum fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate.
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' CPQHSV110V3-MIB::sCellEventTrapD47 snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.232.0.13603399
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:63684->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (415307972) 48 days, 1:37:59.72 SNMPv2-MIB::snmpTrapOID.0 = OID: CPQHSV110V3-MIB::sCellEventTrapD47
Start monitoring HP StorageWorks HSV110 (EVA) array controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQHSV110V3-MIB::sCellEventTrapD47 OID value, configure state conditions and alerts, and monitor any HP StorageWorks HSV110 (EVA) array controller from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.0.13603399 | sCellEventTrapD47 | CPQHSV110V3-MIB |