All MIBs › CPQHSV110V3-MIB › sCellEventTrapD34
sCellEventTrapD34
Module: CPQHSV110V3-MIB
OID (symbolic): CPQHSV110V3-MIB::sCellEventTrapD34
OID (numeric): 1.3.6.1.4.1.232.0.13603380
Node type: NOTIFICATION-TYPE
Description: Severity: Critical -- failure or failure imminent. A drive enclosure power supply is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition. The operational power supply will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply shuts down, whichever occurs first. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the denclNum field as follows:
- If denclNum is less than 99, the location is as indicated by the content of the rackNum and denclNum fields.
- If denclNum is equal to 99, the location is unknown. Note that the content of the rackNum field is undefined in this case.
- If denclNum is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rackNum and denclNum fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate.
- If enclosures.denclNum is less than 99, the location is as indicated by the content of the enclosures.rackNum and enclosures.denclNum fields.
- If enclosures.denclNum is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rackNum field is undefined in this case.
- If enclosures.denclNum is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rackNum and enclosures.denclNum fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate.
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' CPQHSV110V3-MIB::sCellEventTrapD34 snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.232.0.13603380
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:61729->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (338134817) 39 days, 3:15:48.17 SNMPv2-MIB::snmpTrapOID.0 = OID: CPQHSV110V3-MIB::sCellEventTrapD34
Start monitoring HP StorageWorks HSV110 (EVA) array controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQHSV110V3-MIB::sCellEventTrapD34 OID value, configure state conditions and alerts, and monitor any HP StorageWorks HSV110 (EVA) array controller from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.0.13603380 | sCellEventTrapD34 | CPQHSV110V3-MIB |