CPQHSV110V3-MIB :: sCellEventTrapC7

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CPQHSV110V3-MIB › sCellEventTrapC7

sCellEventTrapC7

Module: CPQHSV110V3-MIB

OID (symbolic): CPQHSV110V3-MIB::sCellEventTrapC7

OID (numeric): 1.3.6.1.4.1.232.0.13603079

Node type: NOTIFICATION-TYPE

Description: Severity: Critical -- failure or failure imminent. A Full Copy terminated prior to completion. A remote copy error occurred due to an inaccessible alternate Storage System. The Virtual Disk address specified in the vda field indicates the first block in error. The Full Copy will continue when the Data Replication Destination is restored.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' CPQHSV110V3-MIB::sCellEventTrapC7
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.232.0.13603079

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:60179->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (460669715) 53 days, 7:38:17.15
  SNMPv2-MIB::snmpTrapOID.0 = OID: CPQHSV110V3-MIB::sCellEventTrapC7

Start monitoring HP StorageWorks HSV110 (EVA) array controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQHSV110V3-MIB::sCellEventTrapC7 OID value, configure state conditions and alerts, and monitor any HP StorageWorks HSV110 (EVA) array controller from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.0.13603079sCellEventTrapC7CPQHSV110V3-MIB