All MIBs › CPQHSV110V3-MIB › sCellEventTrap972
sCellEventTrap972
Module: CPQHSV110V3-MIB
OID (symbolic): CPQHSV110V3-MIB::sCellEventTrap972
OID (numeric): 1.3.6.1.4.1.232.0.13602418
Node type: NOTIFICATION-TYPE
Description: Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field has completed its shutdown preparations.
The oldAttr.type field contain the value 1. The oldAttr.value.u32[0] field value indicates the result of the HSV110 controller Cache Memory shutdown operation as follows:
- 1 = Success
- 2 = Failure
- 3 = Not applicable
The oldAttr.value.u32[1] field contains the internal Storage System Management Interface cache shutdown status code.
The oldAttr.value.u32[2] field value indicates the result of the Physical Disk Drive enclosure(s) power off operation as follows:
- 1 = Success
- 2 = Failure
- 3 = Not applicable
The oldAttr.value.u32[3] field contains the internal Storage System Management Interface Physical Disk Drive enclosure(s) power off status code.
The oldAttr.value.u32[4] field value indicates the result of the battery assemblies disable operation as follows:
- 1 = Success
- 2 = Failure
- 3 = Not applicable
The oldAttr.value.u32[5] field value indicates the battery assemblies disable operation failure mode as follows:
- 0 = No failure indicated.
- 1 = Failed only on the HSV110 controller identified in the handle field.
- 2 = Failed only on the other HSV110 controller of the pair.
- 3 = Failed on both HSV110 controllers.
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' CPQHSV110V3-MIB::sCellEventTrap972 snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.232.0.13602418
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:62394->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (380031930) 43 days, 23:38:39.30 SNMPv2-MIB::snmpTrapOID.0 = OID: CPQHSV110V3-MIB::sCellEventTrap972
SNMPv3 example:
snmptrap -v3 -l authPriv -u snmpv3user -a SHA -A "AuthPass1" -x AES -X "PrivPass1" <manager> '' CPQHSV110V3-MIB::sCellEventTrap972
Start monitoring HP StorageWorks HSV110 (EVA) array controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQHSV110V3-MIB::sCellEventTrap972 OID value, configure state conditions and alerts, and monitor any HP StorageWorks HSV110 (EVA) array controller from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.0.13602418 | sCellEventTrap972 | CPQHSV110V3-MIB |