All MIBs › CPQHSV110V3-MIB › sCellEventTrap971
sCellEventTrap971
Module: CPQHSV110V3-MIB
OID (symbolic): CPQHSV110V3-MIB::sCellEventTrap971
OID (numeric): 1.3.6.1.4.1.232.0.13602417
Node type: NOTIFICATION-TYPE
Description: Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field received a request to shutdown.
The oldAttr.type field and field contain the value 1. The oldAttr.value.u32[0] field indicates the type of restart that was requested as follows:
- 0 = None -- no restart
- 1 = Regular -- full restart, host system connectivity is lost until the controller returns to normal operation
- 2 = Fast -- resynchronization, restart of the controller in a manner that has little or no impact on host system connectivity
The oldAttr.value.u32[1] field indicates whether the other HSV110 controller of the pair was requested to remain operational or to also shutdown as follows:
- 0 = Remain operational
- 1 = Coupled shutdown
The oldAttr.value.u32[2] field indicates whether the HSV110 controller was requested to remain in the power on state or power itself off as follows:
- 0 = Remain in the power on state
- 1 = Power itself off
The oldAttr.value.u32[3] field value indicates whether the Physical Disk Drive enclosure(s) was requested to remain in the power on state or to be powered off as follows:
- 0 = Remain in the power on state
- 1 = Powered off
The oldAttr.value.u32[4] field value indicates whether the battery assemblies located within the HSV110 controller were requested to be enabled or disabled as follows:
- 0 = Enabled
- 1 = Disabled
The oldAttr.value.u32[5] field contains the number of seconds the shutdown operation was requested to be delayed.
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' CPQHSV110V3-MIB::sCellEventTrap971 snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.232.0.13602417
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:60971->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (231376427) 26 days, 18:42:44.27 SNMPv2-MIB::snmpTrapOID.0 = OID: CPQHSV110V3-MIB::sCellEventTrap971
Start monitoring HP StorageWorks HSV110 (EVA) array controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQHSV110V3-MIB::sCellEventTrap971 OID value, configure state conditions and alerts, and monitor any HP StorageWorks HSV110 (EVA) array controller from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.0.13602417 | sCellEventTrap971 | CPQHSV110V3-MIB |