All MIBs › CPQHSV110V3-MIB › sCellEventTrap96
sCellEventTrap96
Module: CPQHSV110V3-MIB
OID (symbolic): CPQHSV110V3-MIB::sCellEventTrap96
OID (numeric): 1.3.6.1.4.1.232.0.13602310
Node type: NOTIFICATION-TYPE
Description: Severity: Undetermined -- more information needed to determine severity. A Volume has transitioned to the MISSING state. The affected Volume is identified in the handle field. The addHandle field contains the identity of the Physical Disk Drive that is associated with that Volume. The enclosure number, bay number, and rack number where the associated Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], and attribute.value.u32[2] fields, respectively. The internal identification of that Volume's Redundant Storage Set is contained in the attribute.value.u32[3] field. The attribute.type field contains the value of 1. The value.ul1 field contains the new state. The value.ul2 field contains the old state. The state values that may be found in the value.ul1 and value.ul2 fields are as follows:
- 1 = Normal - Volume is present and operating normally
- 2 = Migrating - Data from this volume is being moved to other storage in this Disk Group
- 4 = Reconstructing - Volume is inaccessible; redundant data is being regenerated and moved to other storage in this Disk Group
- 5 = Completing - This previously inaccessible volume has become accessible; data migration is being completed
- 6 = Reverting - This previously inaccessible volume has become accessible; data is being regenerated
- 7 = Failed - Volume is not being used in the Disk Group; disk errors are preventing normal usage
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' CPQHSV110V3-MIB::sCellEventTrap96 snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.232.0.13602310
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:60685->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (30931725) 3 days, 13:55:17.25 SNMPv2-MIB::snmpTrapOID.0 = OID: CPQHSV110V3-MIB::sCellEventTrap96
Start monitoring HP StorageWorks HSV110 (EVA) array controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQHSV110V3-MIB::sCellEventTrap96 OID value, configure state conditions and alerts, and monitor any HP StorageWorks HSV110 (EVA) array controller from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.232 | compaq | COMPAQ-ID-REC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.232.0.13602310 | sCellEventTrap96 | CPQHSV110V3-MIB |