CPQHSV110V3-MIB :: sCellEventTrap70

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CPQHSV110V3-MIB › sCellEventTrap70

sCellEventTrap70

Module: CPQHSV110V3-MIB

OID (symbolic): CPQHSV110V3-MIB::sCellEventTrap70

OID (numeric): 1.3.6.1.4.1.232.0.13601792

Node type: NOTIFICATION-TYPE

Description: Severity: Warning -- not failed but attention recommended or required. Allocation of a Virtual Disk has stalled due to insufficient space in the Disk Group caused by the failure or pulling of a physical disk drive. The tag1 field contains the identity of the Virtual Disk. The tag2 field contains the identity of the Disk Group. The values that may be found in the state field are as follows:

  • 0 = Attempting to retry the allocation
  • 1 = Awaiting a leveling event (a drive needs to be inserted)

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' CPQHSV110V3-MIB::sCellEventTrap70
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.232.0.13601792

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:49435->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (225817371) 26 days, 3:16:13.71
  SNMPv2-MIB::snmpTrapOID.0 = OID: CPQHSV110V3-MIB::sCellEventTrap70

Start monitoring HP StorageWorks HSV110 (EVA) array controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQHSV110V3-MIB::sCellEventTrap70 OID value, configure state conditions and alerts, and monitor any HP StorageWorks HSV110 (EVA) array controller from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.0.13601792sCellEventTrap70CPQHSV110V3-MIB