CPQHSV110V3-MIB :: sCellEventTrap32

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CPQHSV110V3-MIB › sCellEventTrap32

sCellEventTrap32

Module: CPQHSV110V3-MIB

OID (symbolic): CPQHSV110V3-MIB::sCellEventTrap32

OID (numeric): 1.3.6.1.4.1.232.0.13600770

Node type: NOTIFICATION-TYPE

Description: Severity: Warning -- not failed but attention recommended or required. A physical disk drive will not be used because the maximum number of physical disk drives already exist in the current Storage System. The affected physical disk drive is identified in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerpId field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The location of the physical disk drive is contained in the rackNum, denclNum, and bay fields. Note that the content of the rackNum field will not be valid until a future release. Note also that in this case the content of the reasonCode, flags, rssFlags, inqData, quorumSequence, capacity, and memberState fields is undefined.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' CPQHSV110V3-MIB::sCellEventTrap32
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.232.0.13600770

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:60124->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (142751964) 16 days, 12:31:59.64
  SNMPv2-MIB::snmpTrapOID.0 = OID: CPQHSV110V3-MIB::sCellEventTrap32

Start monitoring HP StorageWorks HSV110 (EVA) array controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CPQHSV110V3-MIB::sCellEventTrap32 OID value, configure state conditions and alerts, and monitor any HP StorageWorks HSV110 (EVA) array controller from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.232compaqCOMPAQ-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.232.0.13600770sCellEventTrap32CPQHSV110V3-MIB