All MIBs › CISCO-C8500-REDUNDANCY-MIB › ccrDesiredSwitchBw
ccrDesiredSwitchBw
Module: CISCO-C8500-REDUNDANCY-MIB
OID (symbolic): CISCO-C8500-REDUNDANCY-MIB::ccrDesiredSwitchBw
OID (numeric): 1.3.6.1.4.1.9.9.105.1.2.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: The desired switching capacity (i.e., bandwidth) of the switch fabric. tenGbps(1) - 10 Gigabits/sec twentyGbps(2) - 20 Gigabits/sec
If the value configured by writing to this object is supported by the device, it will be applied at the next reboot. The speed at which the switch fabric is currently operating is reflected by the value of ccrSwitchBw.
What is ccrDesiredSwitchBw?
Read-write setting used to configure the desired switching fabric bandwidth (10 Gbps or 20 Gbps), applied if supported by the device.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.105.1.2.5 snmpwalk -v2c -c public <target> CISCO-C8500-REDUNDANCY-MIB::ccrDesiredSwitchBw
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.105.1.2.5.1 snmpget -v2c -c public <target> CISCO-C8500-REDUNDANCY-MIB::ccrDesiredSwitchBw.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.9.9.105.1.2.5.1 i <value>
Start monitoring Cisco Catalyst 8540 ATM switch (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-C8500-REDUNDANCY-MIB::ccrDesiredSwitchBw OID value, configure state conditions and alerts, and monitor any Cisco Catalyst 8540 ATM switch (legacy) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.105 | ciscoC8500RedundancyMIB | CISCO-C8500-REDUNDANCY-MIB |
| 1.3.6.1.4.1.9.9.105.1 | ciscoC8500RedundancyMIBObjects | CISCO-C8500-REDUNDANCY-MIB |
| 1.3.6.1.4.1.9.9.105.1.2 | ccrSwitch | CISCO-C8500-REDUNDANCY-MIB |
| 1.3.6.1.4.1.9.9.105.1.2.5 | ccrDesiredSwitchBw | CISCO-C8500-REDUNDANCY-MIB |