AVIAT-ALARM-REPORTING-MIB

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › AVIAT-ALARM-REPORTING-MIB

Organization: Aviat Networks

Last Updated: 2016-05-26

Category: Alarm and Event Management, Vendor: Aviat

Description: Manages alarm reporting configuration and active fault notifications for Aviat microwave radio systems.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is AVIAT-ALARM-REPORTING-MIB?

AVIAT-ALARM-REPORTING-MIB manages alarm reporting configuration and describes the status of active faults for Aviat Networks microwave radio transmission equipment, a technology used in point-to-point wireless backhaul links. Its data centers on fault/alarm status: which alarms are currently active on the radio system, their configuration, and reporting behavior, rather than raw performance counters. As a fault-monitoring MIB, it is specifically geared toward hardware status monitoring — surfacing conditions like radio link failures, hardware faults, or environmental alarms (e.g., power or transceiver issues) on the microwave radio units. It relies on the standard SNMP notification/trap framework and the Aviat enterprise OID tree, and may be used alongside other Aviat radio-performance or inventory MIBs. It is deployed in telecom and utility microwave backhaul networks where Aviat radios link cell towers or remote sites. Engineers can download the AVIAT-ALARM-REPORTING-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in AVIAT-ALARM-REPORTING-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Aviat Networks microwave radio (point-to-point wireless backhaul)

Monitoring Examples

No specific object or table names were captured in the sampled source, so concrete leaf objects cannot be cited; however, given its stated purpose an admin would expect to poll or receive traps for an active-alarm table reflecting current fault conditions on the microwave radio (e.g., link failure, RF transmit/receive faults). An alarm transitioning from clear to active would indicate a degraded or failed radio link requiring dispatch. This is inferred from the module's description rather than confirmed sampled objects.

What Can Be Monitored

  • active alarm status
  • alarm configuration
  • radio link fault conditions
Imported Objects

From AVIAT-TEXTCONVENTION-MIB

AviatYangIdentityRef

From IANA-ITU-ALARM-TC-MIB

IANAItuEventType
IANAItuProbableCause

From ITU-ALARM-TC-MIB

ItuPerceivedSeverity

From SNMPv2-CONF

MODULE-COMPLIANCE
NOTIFICATION-GROUP
OBJECT-GROUP

From SNMPv2-SMI

Counter32
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE

From SNMPv2-TC

DateAndTime
DisplayString
TEXTUAL-CONVENTION
TruthValue

From STXN-GLOBALREGISTER-MIB

aviatModulesOBJECT-IDENTITY

How to Use in IPNetwork Monitor

Example using aviatAlarmInstanceStatusChangeCount OID:

Select an Aviat Networks microwave radio link (point-to-point backhaul) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type aviatAlarmInstanceStatusChangeCount into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of times that the entity has raised or lowered this alarm instance since the system was started. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Alarm reporting and status monitoring for Aviat Networks wireless products.

Start monitoring Aviat Networks microwave radio links (point-to-point backhaul) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download AVIAT-ALARM-REPORTING-MIB