| OID symbolic | OID numeric | Type | Access | Description |
| lhnNsmNotificationModule | 1.3.6.1.4.1.9804.2.1.15 | | | HP StorageWorks P4000 Notifications:
Traps(v1) and Informs(v2c) |
| lhnNsmNotificationModuleConformance | 1.3.6.1.4.1.9804.2.1.15.1 | | | |
| lhnNsmNotificationModuleCompliances | 1.3.6.1.4.1.9804.2.1.15.1.1 | | | |
| lefthandNetworksNsmNotificationMibCompliance | 1.3.6.1.4.1.9804.2.1.15.1.1.1 | | | The compliance statement. |
| lhnNsmNotificationModuleGroups | 1.3.6.1.4.1.9804.2.1.15.1.2 | | | |
| lefthandNetworksNsmNotificationGroup | 1.3.6.1.4.1.9804.2.1.15.1.2.1 | | | The default group for all NSM Notification objects. |
| lefthandNetworksNsmNotificationMibAllNotifications | 1.3.6.1.4.1.9804.2.1.15.1.2.2 | | | The default group for all NSM Notification objects. |
| lhnNsmDevices | 1.3.6.1.4.1.9804.3.1.1 | | | sub-tree for NSM devices |
| lhnNsmEvents | 1.3.6.1.4.1.9804.3.1.1.0 | | | sub-tree for NSM events |
| NTF lhnNsmNotificationGeneric | 1.3.6.1.4.1.9804.3.1.1.0.1 | | | A generic system event was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationBackplane | 1.3.6.1.4.1.9804.3.1.1.0.2 | | | An event for the system backplane was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationController | 1.3.6.1.4.1.9804.3.1.1.0.3 | | | An event for the RAID controller was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationRAID | 1.3.6.1.4.1.9804.3.1.1.0.4 | | | An event for the system RAID was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationDisk | 1.3.6.1.4.1.9804.3.1.1.0.5 | | | An event for a disk was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationBootDevice | 1.3.6.1.4.1.9804.3.1.1.0.6 | | | An event for a boot device was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationFan | 1.3.6.1.4.1.9804.3.1.1.0.7 | | | An event for a fan was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationTemperature | 1.3.6.1.4.1.9804.3.1.1.0.8 | | | An event for a temperature sensor was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationPowerSupply | 1.3.6.1.4.1.9804.3.1.1.0.9 | | | An event for a power supply was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationVoltage | 1.3.6.1.4.1.9804.3.1.1.0.10 | | | An event for a voltage sensor was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationNetwork | 1.3.6.1.4.1.9804.3.1.1.0.11 | | | An event for the network was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationMemory | 1.3.6.1.4.1.9804.3.1.1.0.12 | | | An event for the system memory was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationCPU | 1.3.6.1.4.1.9804.3.1.1.0.13 | | | An event for the CPU was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationLogging | 1.3.6.1.4.1.9804.3.1.1.0.14 | | | An event for the log partition was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationManagementGroup | 1.3.6.1.4.1.9804.3.1.1.0.15 | | | An event for the management group was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationRemoteManagementGroup | 1.3.6.1.4.1.9804.3.1.1.0.16 | | | An event for a remote management group was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationCluster | 1.3.6.1.4.1.9804.3.1.1.0.17 | | | An event for the cluster was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationStorageServer | 1.3.6.1.4.1.9804.3.1.1.0.18 | | | An event for the storage server was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationRemoteCopy | 1.3.6.1.4.1.9804.3.1.1.0.19 | | | An event for a remote copy operation was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationVolume | 1.3.6.1.4.1.9804.3.1.1.0.20 | | | An event for a volume was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| NTF lhnNsmNotificationSnapshot | 1.3.6.1.4.1.9804.3.1.1.0.21 | | | An event for a snapshot was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Added in SAN/iQ 8.5 |
| I32 notificationOldMessageCount | 1.3.6.1.4.1.9804.3.1.1.2.13.1 | Integer32 | read-only | number of notification messages
Used by SAN/iQ 8.1 and earlier.
Obsolete in SAN/iQ 8.5.
Marked as current to increase compatability with some SNMP clients. |
| notificationOldMessageTable | 1.3.6.1.4.1.9804.3.1.1.2.13.2 | | not-accessible | A table of notification messages for the NSM.
The number of entries is given by notificationMessageCount.
Used by SAN/iQ 8.1 and earlier.
Obsolete in SAN/iQ 8.5.
Marked as current to increase compatability with some SNMP clients. |
| notificationOldMessageEntry | 1.3.6.1.4.1.9804.3.1.1.2.13.2.1 | | not-accessible | row of notification message parameters
Used by SAN/iQ 8.1 and earlier.
Obsolete in SAN/iQ 8.5.
Marked as current to increase compatability with some SNMP clients. |
| U32 notificationIndex | 1.3.6.1.4.1.9804.3.1.1.2.13.2.1.1 | Unsigned32 | not-accessible | notification message index
Used by SAN/iQ 8.1 and earlier.
Obsolete in SAN/iQ 8.5.
Marked as current to increase compatability with some SNMP clients. |
| STR notificationMessage | 1.3.6.1.4.1.9804.3.1.1.2.13.2.1.2 | DisplayString | read-only | notification message contents
Used by SAN/iQ 8.1 and earlier.
Obsolete in SAN/iQ 8.5.
Marked as current to increase compatability with some SNMP clients. |
| DAT notificationTime | 1.3.6.1.4.1.9804.3.1.1.2.13.2.1.3 | DateAndTime | read-only | time notification occurred
Used by SAN/iQ 8.1 and earlier.
Obsolete in SAN/iQ 8.5.
Marked as current to increase compatability with some SNMP clients. |
| I32 notificationMessageCount | 1.3.6.1.4.1.9804.3.1.1.2.15.1 | Integer32 | read-only | The number of notification messages available in the history. |
| notificationMessageTable | 1.3.6.1.4.1.9804.3.1.1.2.15.2 | | not-accessible | A table of the last 100 notifications for the NSM.
The number of entries is given by messageNotificationCount. |
| notificationMessageEntry | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1 | | not-accessible | A row of notification message information.
The information contained in each row is dependant on the trap type
and the event that caused the trap. Not all NotificationMessageEntry
objects will have values. |
| U32 notificationMessageIndex | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.1 | Unsigned32 | not-accessible | The index for the notificationMessageTable table. |
| STR message | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.2 | DisplayString | read-only | The notification message. |
| DAT messageTime | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.3 | DateAndTime | read-only | The time the notification was sent. |
| STR eventID | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.4 | DisplayString | read-only | The event ID in symbolic format. |
| INT severity | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.5 | INTEGER | read-only | The event severity. |
| STR hostname | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.6 | DisplayString | read-only | The NSM hostname. |
| STR primaryIP | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.7 | DisplayString | read-only | The primary IP address. |
| STR mac | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.8 | DisplayString | read-only | The MAC address of the primary IP address. |
| STR serialNumber | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.9 | DisplayString | read-only | The chassis serial number. |
| STR modelName | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.10 | DisplayString | read-only | The system model name. |
| STR productName | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.11 | DisplayString | read-only | The OEM product name. |
| STR productID | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.12 | DisplayString | read-only | The OEM product ID. |
| T/F hpim | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.13 | TruthValue | read-only | HP Insight Manager SNMP agent installed on NSM |
| STR softwareVersion | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.14 | DisplayString | read-only | The SAN/iQ software version |
| STR managementGroupVersion | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.15 | DisplayString | read-only | The management group version. |
| STR managementGroupSerialNumber | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.16 | DisplayString | read-only | The management group serial number. |
| STR managementGroup | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.17 | DisplayString | read-only | The management group name. |
| STR cluster | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.18 | DisplayString | read-only | The cluster name. |
| STR site | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.19 | DisplayString | read-only | The site the cluster is in. |
| STR componentName | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.20 | DisplayString | read-only | The component name. |
| STR systemName | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.21 | DisplayString | read-only | The system hostname. |
| STR logicalName | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.22 | DisplayString | read-only | The logical name for the component. |
| STR componentState | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.23 | DisplayString | read-only | The component state. |
| STR componentModel | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.24 | DisplayString | read-only | The component model. |
| STR componentSerialNumber | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.25 | DisplayString | read-only | The component serial number. |
| STR componentFirmwareVersion | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.26 | DisplayString | read-only | The component firmware version. |
| STR componentHardwareVersion | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.27 | DisplayString | read-only | The component hardware version. |
| STR driverVersion | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.28 | DisplayString | read-only | The driver version. |
| STR biosVersion | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.29 | DisplayString | read-only | The BIOS version. |
| STR raidConfiguration | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.30 | DisplayString | read-only | The RAID configuration. |
| STR diskInterface | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.31 | DisplayString | read-only | The disk interface type. |
| I32 diskCapacity | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.32 | Integer32 | read-only | The disk capacity. |
| STR raidState | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.33 | DisplayString | read-only | The RAID state. |
| STR parityInitStatus | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.34 | DisplayString | read-only | The RAID Parity Initialization status. |
| STR healthState | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.35 | DisplayString | read-only | The disk health state. |
| STR bbuState | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.36 | DisplayString | read-only | The BBU state. |
| STR cacheState | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.37 | DisplayString | read-only | The cache state. |
| STR linkState | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.38 | DisplayString | read-only | The link state. |
| STR vipState | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.39 | DisplayString | read-only | The cluster VIP state. |
| STR maintenanceMode | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.40 | DisplayString | read-only | The management group maintenance mode. |
| I32 minFanSpeed | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.41 | Integer32 | read-only | The minimal fan speed. |
| G32 fanSpeedEx | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.42 | Gauge32 | read-only | The fan speed. |
| I32 highTemperatureLimit | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.43 | Integer32 | read-only | The high temperature limit. |
| STR temperatureState | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.44 | DisplayString | read-only | The component temperature state. |
| G32 temperature | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.45 | Gauge32 | read-only | The component temperature. |
| I32 highVoltageLimit | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.46 | Integer32 | read-only | The high voltage limit. |
| I32 lowVoltageLimit | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.47 | Integer32 | read-only | The low voltage limit. |
| G32 voltage | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.48 | Gauge32 | read-only | The voltage. |
| G32 utilization | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.49 | Gauge32 | read-only | The rescource utilization. |
| G32 latency | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.50 | Gauge32 | read-only | The storage server latency. |
| G32 memoryUtilization | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.51 | Gauge32 | read-only | The memory utilization. |
| I32 memoryConfig | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.52 | Integer32 | read-only | The system memory configuration. |
| G32 cpuUtilization | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.53 | Gauge32 | read-only | The CPU utilization. |
| I32 cpuConfig | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.54 | Integer32 | read-only | The number of CPU cores. |
| STR diskSpeed | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.55 | DisplayString | read-only | The disk interface speed. |
| STR licenseState | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.56 | DisplayString | read-only | The feature license state. |
| STR utilizationState | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.57 | DisplayString | read-only | The utilization state. |
| STR latencyState | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.58 | DisplayString | read-only | The storage server latency state. |
| STR serverVIPAddress | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.59 | DisplayString | read-only | The VIP address. |
| STR serverVIPState | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.60 | DisplayString | read-only | The VIP state. |
| STR replicationState | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.61 | DisplayString | read-only | The volume/snapshot replication state. |
| STR snapshotState | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.62 | DisplayString | read-only | The snapshot state. |
| STR snapshotSchedState | 1.3.6.1.4.1.9804.3.1.1.2.15.2.1.63 | DisplayString | read-only | The snapshot schedule state. |
| NTF userNotification | 1.3.6.1.4.1.9804.3.1.1.3.1 | | | A system event was generated.
The user chose to be notified of this condition
via SNMP. A table of messages exists which stores
all the notifications issued. This trap will
contain the OID referring to the corresponding
message stored in this table.
Used by SAN/iQ 8.1 and earlier.
Obsolete in SAN/iQ 8.5.
Marked as current to increase compatability with some SNMP clients. |