| OID symbolic | OID numeric | Type | Access | Description |
| aptisActionsModule | 1.3.6.1.4.1.2637.1.1.5 | | | The following variables describe the administrative actions
that may be invoked through SNMP. |
| slotControlTable | 1.3.6.1.4.1.2637.2.3.203 | | not-accessible | slot control |
| slotControlEntry | 1.3.6.1.4.1.2637.2.3.203.1 | | not-accessible | This is the structure of entries in the
slotControlTable. |
| INT slotControlInstance | 1.3.6.1.4.1.2637.2.3.203.1.1 | INTEGER | read-create | Each invocation of this action will have a unique
instance number, assigned by the switch. |
| INT slotControlStatusGeneral | 1.3.6.1.4.1.2637.2.3.203.1.2 | INTEGER | read-create | like, did it work, or what? This is the standard
actionStatus enum used for all actions. |
| INT slotControlStatusSpecific | 1.3.6.1.4.1.2637.2.3.203.1.3 | INTEGER | read-create | like, did it work, or what? If the generalStatus is
err-param or failed, this will hold a more specific
error number. |
| INT slotControlSlotIndex | 1.3.6.1.4.1.2637.2.3.203.1.11 | INTEGER | read-create | The physical slot number. |
| INT slotControlSlotAction | 1.3.6.1.4.1.2637.2.3.203.1.12 | INTEGER | read-create | The action requested for this slot. |
| sessionTerminateTable | 1.3.6.1.4.1.2637.2.3.230 | | not-accessible | This action allows a remote manager to terminate an
active session. |
| sessionTerminateEntry | 1.3.6.1.4.1.2637.2.3.230.1 | | not-accessible | This is the structure of entries in the
sessionTerminateTable. |
| INT sessionTerminateInstance | 1.3.6.1.4.1.2637.2.3.230.1.1 | INTEGER | read-create | Each invocation of this action will have a unique
instance number, assigned by the switch. |
| INT sessionTerminateStatusGeneral | 1.3.6.1.4.1.2637.2.3.230.1.2 | INTEGER | read-create | This is the standard actionStatus enum used for all
actions. |
| INT sessionTerminateStatusSpecific | 1.3.6.1.4.1.2637.2.3.230.1.3 | INTEGER | read-create | If generalStatus is err-param or failed, this will
hold a more specific error number. |
| INT sessionTerminateBootEra | 1.3.6.1.4.1.2637.2.3.230.1.11 | INTEGER | read-create | An input parameter to the session-terminate action.
Together with the sessionID, uniquely identifies the
session to terminate. If a value is provided, it must
match the current value of bootEra, so this field is
only provided as a safeguard to ensure that sessions
from the wrong boot era can't be terminated
accidentally. |
| INT sessionTerminateSessionID | 1.3.6.1.4.1.2637.2.3.230.1.12 | INTEGER | read-create | An input parameter to the session-terminate action,
naming the session which should be terminated. |
| STR sessionTerminateSignature | 1.3.6.1.4.1.2637.2.3.230.1.13 | DisplayString | read-create | An input parameter to the session-terminate action,
providing a cryptographically secure verification that
the manager requesting the termination has the
appropriate credentials to do so. NOTE: the exact
algorithm for generating the signature has not yet
been determined. |
| t1TestTable | 1.3.6.1.4.1.2637.2.3.2106 | | not-accessible | T1 Testing Control. |
| t1TestEntry | 1.3.6.1.4.1.2637.2.3.2106.1 | | not-accessible | This is the structure of entries in the
t1TestTable. |
| INT t1TestInstance | 1.3.6.1.4.1.2637.2.3.2106.1.1 | INTEGER | read-create | T1 Test Instance. |
| INT t1TestTestType | 1.3.6.1.4.1.2637.2.3.2106.1.2 | INTEGER | read-create | type of test to run. |
| INT t1TestSlotNumber | 1.3.6.1.4.1.2637.2.3.2106.1.3 | INTEGER | read-create | ID of the slot to run the test on. |
| INT t1TestPortNumber | 1.3.6.1.4.1.2637.2.3.2106.1.4 | INTEGER | read-create | ID of the DS1 to run the test on. |
| INT t1TestTestLength | 1.3.6.1.4.1.2637.2.3.2106.1.5 | INTEGER | read-create | number of bytes of data to send. |
| INT t1TestErrorRate | 1.3.6.1.4.1.2637.2.3.2106.1.6 | INTEGER | read-create | percentage of data received with errors. |
| INT t1TestState | 1.3.6.1.4.1.2637.2.3.2106.1.7 | INTEGER | read-create | current state of test. |
| flashWriteTable | 1.3.6.1.4.1.2637.2.3.3501 | | not-accessible | This action causes a portion of the configuration
subtree to be written out to a text file on one of the
CVX system's local flash cards. |
| flashWriteEntry | 1.3.6.1.4.1.2637.2.3.3501.1 | | not-accessible | This is the structure of entries in the
flashWriteTable. |
| INT flashWriteInstance | 1.3.6.1.4.1.2637.2.3.3501.1.1 | INTEGER | read-create | Each invocation of this action will have a unique
instance number, assigned by the switch. |
| INT flashWriteStatusGeneral | 1.3.6.1.4.1.2637.2.3.3501.1.2 | INTEGER | read-create | This is the standard actionStatus enum used for all
actions. |
| INT flashWriteStatusSpecific | 1.3.6.1.4.1.2637.2.3.3501.1.3 | INTEGER | read-create | If generalStatus is err-param or failed, this will
hold a more specific error number. |
| STR flashWritePathString | 1.3.6.1.4.1.2637.2.3.3501.1.11 | DisplayString | read-create | The starting node in the configuration tree. The
contents of all the nodes under this node will be
written out to the text file. |
| STR flashWriteFileName | 1.3.6.1.4.1.2637.2.3.3501.1.12 | DisplayString | read-create | The relative file name to hold the text config. The
CVX file system uses drive C: to refer to the bottom
flash card, and D: to refer to the top flash card. If
the drive letter is not specified, then C: is assumed.
If this file exists, it will only be overwritten with
a complete copy of the output from this action. NOTE
that the file CONFIG.CVX is not accessible through
this action. To save the config to flash where it will
be used at the next reboot, use the flashSave action
instead. |
| INT flashWriteBytesWritten | 1.3.6.1.4.1.2637.2.3.3501.1.13 | INTEGER | read-create | On success, the total number of bytes written to
flash. |
| BOO flashWriteVerboseMode | 1.3.6.1.4.1.2637.2.3.3501.1.14 | Boolean | read-create | Setting this field to TRUE requests that the output
file contain all configuration values, otherwise only
those that differ from the default values. |
| flashReadTable | 1.3.6.1.4.1.2637.2.3.3502 | | not-accessible | This action causes the configuration subtree to be
read to one of the CVX system's local flash cards. |
| flashReadEntry | 1.3.6.1.4.1.2637.2.3.3502.1 | | not-accessible | This is the structure of entries in the
flashReadTable. |
| INT flashReadInstance | 1.3.6.1.4.1.2637.2.3.3502.1.1 | INTEGER | read-create | Each invocation of this action will have a unique
instance number, assigned by the switch. |
| INT flashReadStatusGeneral | 1.3.6.1.4.1.2637.2.3.3502.1.2 | INTEGER | read-create | This is the standard actionStatus enum used for all
actions. |
| STR flashReadFileName | 1.3.6.1.4.1.2637.2.3.3502.1.12 | DisplayString | read-create | The relative file name to hold the text config. The
CVX file system uses drive C: to refer to the bottom
flash card, and D: to refer to the top flash card. If
the drive letter is not specified, then C: is
assumed. |
| INT flashReadLinesRead | 1.3.6.1.4.1.2637.2.3.3502.1.13 | INTEGER | read-create | On success, the total number of lines read from
flash. |
| flashSaveTable | 1.3.6.1.4.1.2637.2.3.3503 | | not-accessible | This action saves the configuration to the flash file
CONFIG.CVX. It is equivalent to the 'write' command in
the CLI. |
| flashSaveEntry | 1.3.6.1.4.1.2637.2.3.3503.1 | | not-accessible | This is the structure of entries in the
flashSaveTable. |
| INT flashSaveInstance | 1.3.6.1.4.1.2637.2.3.3503.1.1 | INTEGER | read-create | Each invocation of this action will have a unique
instance number, assigned by the switch. |
| INT flashSaveStatusGeneral | 1.3.6.1.4.1.2637.2.3.3503.1.2 | INTEGER | read-create | This is the standard actionStatus enum used for all
actions. |
| INT flashSaveStatusSpecific | 1.3.6.1.4.1.2637.2.3.3503.1.3 | INTEGER | read-create | If generalStatus is err-param or failed, this will
hold a more specific error number. |
| resetTable | 1.3.6.1.4.1.2637.2.3.3510 | | not-accessible | CVX Chassis Options. |
| resetEntry | 1.3.6.1.4.1.2637.2.3.3510.1 | | not-accessible | This is the structure of entries in the
resetTable. |
| INT resetInstance | 1.3.6.1.4.1.2637.2.3.3510.1.1 | INTEGER | read-create | Each invocation of this action will have a unique
instance number, assigned by the switch. |
| INT resetStatusGeneral | 1.3.6.1.4.1.2637.2.3.3510.1.2 | INTEGER | read-create | This is the standard actionStatus enum used for all
actions. |
| INT resetResetType | 1.3.6.1.4.1.2637.2.3.3510.1.11 | INTEGER | read-create | Select the type of reset requested. |