ADVA-FSPR7-CFM-EXTENSION-MIB

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ADVA-FSPR7-CFM-EXTENSION-MIB

Organization: ADVA Optical Networking

Last Updated: 2011-02-03

Category: Optical and WDM, Vendor: ADVA Optical

Description: Extends IEEE 802.1ag CFM management for ADVA Optical Networking FSP R7 carrier Ethernet OAM functionality.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is ADVA-FSPR7-CFM-EXTENSION-MIB?

ADVA-FSPR7-CFM-EXTENSION-MIB extends IEEE 802.1ag Connectivity Fault Management (CFM) support on ADVA Optical Networking's FSP R7 carrier Ethernet platform, adding ADVA-specific alarm-severity configuration and alarm-state objects layered on top of standard CFM maintenance-endpoint (MEP) constructs. It exposes both configuration data -- per-MEP alarm severity assignment (indexed by maintenance domain, maintenance association, and MEP identifier) -- and current alarm/fault state for those MEPs. Its monitoring value is squarely in fault monitoring: it lets an administrator see which CFM alarms (e.g. loss of continuity, remote defect indication) are currently active on a given MEP and at what configured severity, which is central to detecting Ethernet OAM connectivity faults on carrier Ethernet services. It has a clear dependency on the IEEE 802.1ag CFM standard and the associated standard CFM MIB, whose MD/MA/MEP indexing scheme it reuses and extends with ADVA-specific alarm objects. It is deployed on ADVA FSP R7-series carrier Ethernet network elements used by service providers for Ethernet OAM and SLA fault monitoring. Engineers can download the ADVA-FSPR7-CFM-EXTENSION-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in ADVA-FSPR7-CFM-EXTENSION-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • ADVA Optical Networking FSP R7-series carrier Ethernet network elements

Monitoring Examples

An administrator would poll mepAlarmSeverityTable/mepAlarmSeverityEntry (indexed by mepAlarmSeverityMdIndex, mepAlarmSeverityMaNetIndex, mepAlarmSeverityMepIdentifier) to confirm the configured mepAlarmSeverityType/mepAlarmSeverityValue for a given maintenance endpoint, and would check mepAlarmTable/mepAlarmEntry for the same MEP to see if an alarm is currently active. A MEP reporting an active alarm entry when its severity is configured as critical would indicate a real connectivity fault (e.g. loss of continuity) on that carrier Ethernet service requiring immediate attention, while cfmAlarms/cfmAlarmObjects would be used to correlate module-wide alarm notifications.

What Can Be Monitored

  • per-MEP alarm severity configuration
  • active CFM alarm state per MEP
  • connectivity fault (loss of continuity) alarms
  • remote defect indication alarms
Imported Objects

From ADVA-MIB

ServiceImpairment
TrapAlarmSeverity
fspR7OBJECT-IDENTITY
neEventLogIdentityTranslationOBJECT-TYPE
neEventLogTimeStampOBJECT-TYPE

From SNMPv2-CONF

MODULE-COMPLIANCE
NOTIFICATION-GROUP
OBJECT-GROUP

From SNMPv2-SMI

MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE
Unsigned32

From SNMPv2-TC

DateAndTime
TEXTUAL-CONVENTION
OIDs

RFC description

ADVA FSP7000 Ethernet CFM extension for managing connectivity fault management alarms and severity.

Start monitoring ADVA Optical Networking FSP R7-series carrier Ethernet network elements with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download ADVA-FSPR7-CFM-EXTENSION-MIB