All MIBs › ADVA-FSPR7-CFM-EXTENSION-MIB › mepAlarmSeverityValue
mepAlarmSeverityValue
Module: ADVA-FSPR7-CFM-EXTENSION-MIB
OID (symbolic): ADVA-FSPR7-CFM-EXTENSION-MIB::mepAlarmSeverityValue
OID (numeric): 1.3.6.1.4.1.2544.1.11.6.1.1.10.1.5
Node type: OBJECT-TYPE
Type: TrapAlarmSeverity
Access: read-write
Description: This object identifies the severity assigned to this alarm.
What is mepAlarmSeverityValue?
This object stores the configured severity level (critical, major, minor, warning, or clear) that should be assigned to a particular alarm when raised. Network engineers use this to set alarm importance and control escalation behavior, ensuring critical faults trigger immediate notifications. An example is configuring a specific alarm to "critical" severity to ensure it pages on-call engineers immediately.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.6.1.1.10.1.5 snmpwalk -v2c -c public <target> ADVA-FSPR7-CFM-EXTENSION-MIB::mepAlarmSeverityValue
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.6.1.1.10.1.5.1 snmpget -v2c -c public <target> ADVA-FSPR7-CFM-EXTENSION-MIB::mepAlarmSeverityValue.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.11.6.1.1.10.1.5.1 s <value>
Start monitoring ADVA Optical Networking FSP R7-series carrier Ethernet network elements with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-CFM-EXTENSION-MIB::mepAlarmSeverityValue OID value, configure state conditions and alerts, and monitor any ADVA Optical Networking FSP R7-series carrier Ethernet network elements from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.11.6 | cfmExtensionMIB | ADVA-FSPR7-CFM-EXTENSION-MIB |
| 1.3.6.1.4.1.2544.1.11.6.1 | cfmAlarmMIB | ADVA-FSPR7-CFM-EXTENSION-MIB |
| 1.3.6.1.4.1.2544.1.11.6.1.1 | cfmAlarmObjects | ADVA-FSPR7-CFM-EXTENSION-MIB |
| 1.3.6.1.4.1.2544.1.11.6.1.1.10 | mepAlarmSeverityTable | ADVA-FSPR7-CFM-EXTENSION-MIB |
| 1.3.6.1.4.1.2544.1.11.6.1.1.10.1 | mepAlarmSeverityEntry | ADVA-FSPR7-CFM-EXTENSION-MIB |
| 1.3.6.1.4.1.2544.1.11.6.1.1.10.1.5 | mepAlarmSeverityValue | ADVA-FSPR7-CFM-EXTENSION-MIB |