Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is ADC-INTERREACH-SPECTRUM-MIB?
ADC-INTERREACH-SPECTRUM-MIB is a private MIB from ADC Telecommunications for its InterReach Spectrum distributed antenna system (DAS), covering the IF Expansion Units (IFEUs) and Remote Antenna Units (RAUs) that distribute cellular/wireless signal throughout a building or campus. It exposes a unit-status table (irsUnitStatusTable) identifying each IFEU/RAU by a multi-part unit ID and reporting its current status, plus a general-information table (irsUnitGenTable) describing each unit's type. Its monitoring role is centered on hardware status of the DAS network elements - tracking whether each remote unit is online, degraded, or faulted (irsUnitStatusStatus), which is critical for maintaining consistent in-building wireless coverage since a single failed RAU can create a coverage dead zone. It is a standalone ADC private-enterprise MIB specific to the InterReach Spectrum product line, with no apparent dependency on external wireless standards MIBs. It is deployed in enterprise, stadium, and campus in-building wireless deployments using ADC InterReach Spectrum DAS hardware. Network engineers evaluating or troubleshooting this functionality can download the ADC-INTERREACH-SPECTRUM-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in ADC-INTERREACH-SPECTRUM-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- ADC InterReach Spectrum distributed antenna system (IFEU/RAU units)
Monitoring Examples
A facilities/RF engineer would walk irsUnitStatusTable (keyed by irsUnitStatusUnitId1/irsUnitStatusUnitId2/irsUnitStatusUnitId3) and check irsUnitStatusStatus to spot a Remote Antenna Unit that has gone offline or faulted, which would show up as a dead zone in in-building coverage. Cross-referencing irsUnitGenTable's irsUnitGenType confirms whether the affected unit is an IFEU (head-end) or RAU (remote antenna), helping prioritize the truck roll for repair.
What Can Be Monitored
- per-unit operational status
- unit type (IFEU vs RAU)
- unit identification
This MIB depends on
Related MIBs
Imported Objects
From ADC-FLEXWAVE-URH-MIB
| adc | OBJECT-IDENTITY |
| fwuHstName | OBJECT-TYPE |
| fwuNotificationStatus | OBJECT-TYPE |
| fwuRmtName | OBJECT-TYPE |
| fwuSystemAlarmCode | |
| fwuTrapSequenceNumber | OBJECT-TYPE |
| fwuTrapTimeStamp | OBJECT-TYPE |
From ADC-FWU-IRS-TC-MIB
| LatAndLong | |
| RauIntPath | |
| RauIntPathDir | |
| UnitId1 | |
| UnitId2 | |
| UnitId3 | |
| UnitType |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Counter32 | |
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE |
From SNMPv2-TC
| DisplayString |
How to Use in IPNetwork Monitor
Example using irsUnitGenUpTime OID:
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| interReach | 1.3.6.1.4.1.2014.20 | |||
| interReachSpectrum | 1.3.6.1.4.1.2014.20.1 | |||
| interReachSpectrumMibModule | 1.3.6.1.4.1.2014.20.1.1 | The MIB module for the ADC InterReach Spectrum System IF Expansion Units (IFEUs) and Remote Antenna Units (RAUs). | ||
| irsUnitObjects | 1.3.6.1.4.1.2014.20.1.1.1 | |||
| irsUnitStatusTable | 1.3.6.1.4.1.2014.20.1.1.1.1 | not-accessible | This table contains the current overall status of the IFEUs and RAUs in the system. Rows are automatically created and deleted by the agent according to the status of the IFEUs and RAUs. | |
| irsUnitStatusEntry | 1.3.6.1.4.1.2014.20.1.1.1.1.1 | not-accessible | An entry (conceptual row) in the irsUnitStatusTable. | |
| UNI irsUnitStatusUnitId1 | 1.3.6.1.4.1.2014.20.1.1.1.1.1.1 | UnitId1 | not-accessible | The first portion of a unit's node address, indicating the host number. |
| UNI irsUnitStatusUnitId2 | 1.3.6.1.4.1.2014.20.1.1.1.1.1.2 | UnitId2 | not-accessible | The second portion of a unit's node address, indicating the remote DART chassis address. |
| UNI irsUnitStatusUnitId3 | 1.3.6.1.4.1.2014.20.1.1.1.1.1.3 | UnitId3 | not-accessible | The third portion of a unit's node address, indicating the address of an IFEU, MRAU, or SRAU. |
| INT irsUnitStatusStatus | 1.3.6.1.4.1.2014.20.1.1.1.1.1.4 | INTEGER | read-only | The unit's overall status. Units with a status of okay or one which generally indicates the unit is communicating should be present in other tables such as the irsUnitGenTable. Units with a status of noComms, disconnect, portMissWired, noConnect, portShort, or portTrip will not be present in other tables. |
| irsUnitGenTable | 1.3.6.1.4.1.2014.20.1.1.1.2 | not-accessible | This table contains general state and configuration data for IFEUs and RAUs. Rows are automatically created and deleted by the agent according to the status of the IFEUs and RAUs. | |
| irsUnitGenEntry | 1.3.6.1.4.1.2014.20.1.1.1.2.1 | not-accessible | An entry (conceptual row) in the irsUnitGenTable. | |
| UNI irsUnitGenUnitId1 | 1.3.6.1.4.1.2014.20.1.1.1.2.1.1 | UnitId1 | not-accessible | The first portion of a unit's node address, indicating the host number. |
| UNI irsUnitGenUnitId2 | 1.3.6.1.4.1.2014.20.1.1.1.2.1.2 | UnitId2 | not-accessible | The second portion of a unit's node address, indicating the remote DART chassis address. |
| UNI irsUnitGenUnitId3 | 1.3.6.1.4.1.2014.20.1.1.1.2.1.3 | UnitId3 | not-accessible | The third portion of a unit's node address, indicating the address of an IFEU, MRAU, or SRAU. |
| UNI irsUnitGenType | 1.3.6.1.4.1.2014.20.1.1.1.2.1.4 | UnitType | read-only | The basic type of a unit. |
| STR irsUnitGenTypeName | 1.3.6.1.4.1.2014.20.1.1.1.2.1.5 | DisplayString | read-only | The full type name of a unit. |
| STR irsUnitGenSn | 1.3.6.1.4.1.2014.20.1.1.1.2.1.6 | DisplayString | read-only | The serial numbers of the modules in the unit, separated by commas. |
| STR irsUnitGenEpn | 1.3.6.1.4.1.2014.20.1.1.1.2.1.7 | DisplayString | read-only | The engineering part number(s) of the unit and/or the modules in the unit, separated by commas. |
| STR irsUnitGenHwId | 1.3.6.1.4.1.2014.20.1.1.1.2.1.8 | DisplayString | read-only | The hardware IDs of the modules in the unit, separated by commas. |
| STR irsUnitGenFwVer | 1.3.6.1.4.1.2014.20.1.1.1.2.1.9 | DisplayString | read-only | The firmware version of the unit. |
| STR irsUnitGenLabel | 1.3.6.1.4.1.2014.20.1.1.1.2.1.10 | DisplayString | read-write | The user settable label of the unit. |
| C32 irsUnitGenUpTimeEx | 1.3.6.1.4.1.2014.20.1.1.1.2.1.11 | Counter32 | read-only | The time in seconds since the unit last started up. |
| STR irsUnitGenMajorAlarmCode | 1.3.6.1.4.1.2014.20.1.1.1.2.1.12 | DisplayString | read-only | The major alarm codes, comma separated. |
| STR irsUnitGenMinorAlarmCode | 1.3.6.1.4.1.2014.20.1.1.1.2.1.13 | DisplayString | read-only | The minor alarm codes, comma separated. |
| STR irsUnitGenTemperature | 1.3.6.1.4.1.2014.20.1.1.1.2.1.14 | DisplayString | read-only | The unit temperatures, comma separated. For an IFEU, these are the temperatures of the DL and UL boards. For an RAU, these are the temperature of the main board followed by the temperatures of the RF boards. |
| STR irsUnitGenReboot | 1.3.6.1.4.1.2014.20.1.1.1.2.1.15 | DisplayString | read-write | Reboot a unit by setting this string to SoftReset or HardReset which will cause a soft or hard reset respectively to be performed in the unit. RF will be temporarily lost while the unit boots up. Any child units under the unit being reset will also be reset. Thus performing a reset on an IFEU has the effect of also resetting all the MRAUs and SRAUs under it. |
| INT irsUnitGenInOutService | 1.3.6.1.4.1.2014.20.1.1.1.2.1.16 | INTEGER | read-write | The in-service or out-of-service setting of a unit. |
| STR irsUnitGenCatalogNumber | 1.3.6.1.4.1.2014.20.1.1.1.2.1.17 | DisplayString | read-only | The TE catalog part number(s) of the unit and/or the modules in the unit, separated by commas. |
| irsRauObjects | 1.3.6.1.4.1.2014.20.1.1.1.3 | |||
| irsRauGenTable | 1.3.6.1.4.1.2014.20.1.1.1.3.1 | not-accessible | Table of RAU general parameters. Rows are automatically created and deleted by the agent according to the status of the RAUs. | |
| irsRauGenEntry | 1.3.6.1.4.1.2014.20.1.1.1.3.1.1 | not-accessible | An entry (conceptual row) in the irsRauGenTable. | |
| UNI irsRauGenUnitId1 | 1.3.6.1.4.1.2014.20.1.1.1.3.1.1.1 | UnitId1 | not-accessible | The first portion of a unit's node address, indicating the host number. |
| UNI irsRauGenUnitId2 | 1.3.6.1.4.1.2014.20.1.1.1.3.1.1.2 | UnitId2 | not-accessible | The second portion of a unit's node address, indicating the remote DART chassis address. |
| UNI irsRauGenUnitId3 | 1.3.6.1.4.1.2014.20.1.1.1.3.1.1.3 | UnitId3 | not-accessible | The third portion of a unit's node address, indicating the address of an IFEU, MRAU, or SRAU. |
| LAT irsRauGenLatitude | 1.3.6.1.4.1.2014.20.1.1.1.3.1.1.4 | LatAndLong | read-write | The RAU's latitude. It is of the format: N/S (+|-)ddd.dddddd where 'N/S' speaks to latitude. If the data is not present to the decimal then zeros must be inserted. i.e. N/S +001.100000 is valid while N/S 1.123456 is not. |
| LAT irsRauGenLongitude | 1.3.6.1.4.1.2014.20.1.1.1.3.1.1.5 | LatAndLong | read-write | The RAU's longitude. It is of the format: E/W (+|-)ddd.dddddd where 'E/W' speaks to longitude. If the data is not present to the decimal then zeros must be inserted. i.e. E/W 001.123000 is valid while E/W 1.1230000 is not. |
| INT irsRauGenAntennaDisconnectAlarmMask | 1.3.6.1.4.1.2014.20.1.1.1.3.1.1.6 | INTEGER | read-write | Enable or disable RAU's antenna disconnect alarm. |
| irsRauBandTable | 1.3.6.1.4.1.2014.20.1.1.1.3.2 | not-accessible | Table of RAU band parameters. Each row of the table contains the band settings for one band of one RAU. Rows are automatically created and deleted by the agent according to the status of the RAUs. | |
| irsRauBandEntry | 1.3.6.1.4.1.2014.20.1.1.1.3.2.1 | not-accessible | An entry (conceptual row) in the irsRauBandTable. | |
| UNI irsRauBandUnitId1 | 1.3.6.1.4.1.2014.20.1.1.1.3.2.1.1 | UnitId1 | not-accessible | The first portion of a unit's node address, indicating the host number. |
| UNI irsRauBandUnitId2 | 1.3.6.1.4.1.2014.20.1.1.1.3.2.1.2 | UnitId2 | not-accessible | The second portion of a unit's node address, indicating the remote DART chassis address. |
| UNI irsRauBandUnitId3 | 1.3.6.1.4.1.2014.20.1.1.1.3.2.1.3 | UnitId3 | not-accessible | The third portion of a unit's node address, indicating the address of an IFEU, MRAU, or SRAU. |
| I32 irsRauBandId | 1.3.6.1.4.1.2014.20.1.1.1.3.2.1.4 | Integer32 | not-accessible | The RAU band ID. These are consecutive integers starting at 1 and going up to the number of bands supported by the particular type of RAU. |
| NUM irsRauBandIntPath | 1.3.6.1.4.1.2014.20.1.1.1.3.2.1.5 | RauIntPath | read-only | The RAU internal path used for the band. This variable can be used for correlating bands with paths such as to determine the band associated with a notification for a particular RAU path. |
| STR irsRauBandName | 1.3.6.1.4.1.2014.20.1.1.1.3.2.1.6 | DisplayString | read-only | A descriptive name of the band including any RAU MIMO path designation such as: Upper C 700, Path 1 |
| BIT irsRauBandState | 1.3.6.1.4.1.2014.20.1.1.1.3.2.1.7 | Bits | read-only | The band state represented by 6 bits: bit 0: band state is normal bit 1: band has not been linked to any DARTs bit 2: band is shutdown due to an internal major alarm bit 3: band is shutdown due to an upstream major alarm bi3 4: band is locked out of service by user bit 5: associated DART is in standby |
| INT irsRauBandUserLockout | 1.3.6.1.4.1.2014.20.1.1.1.3.2.1.8 | INTEGER | read-write | The band lockout setting (also readable as the userLockout bit in irsRauBandState). Setting this value to 2 will cause the band to be put out of service. |
| I32 irsRauBandAdditionalGain | 1.3.6.1.4.1.2014.20.1.1.1.3.2.1.9 | Integer32 | read-only | RAU band additional gain beyond that of a standard RAU in units of dB. |
| irsRauAttenuatorTable | 1.3.6.1.4.1.2014.20.1.1.1.3.3 | not-accessible | Table of RAU attenuator settings. Each row of the table contains settings for one attenuator of one RAU. Rows are automatically created and deleted by the agent according to the status of the RAUs. | |
| irsRauAttenuatorEntry | 1.3.6.1.4.1.2014.20.1.1.1.3.3.1 | not-accessible | An entry (conceptual row) in the irsRauAttenuatorTable. | |
| UNI irsRauAttenuatorUnitId1 | 1.3.6.1.4.1.2014.20.1.1.1.3.3.1.1 | UnitId1 | not-accessible | The first portion of a unit's node address, indicating the host number. |
| UNI irsRauAttenuatorUnitId2 | 1.3.6.1.4.1.2014.20.1.1.1.3.3.1.2 | UnitId2 | not-accessible | The second portion of a unit's node address, indicating the remote DART chassis address. |
| UNI irsRauAttenuatorUnitId3 | 1.3.6.1.4.1.2014.20.1.1.1.3.3.1.3 | UnitId3 | not-accessible | The third portion of a unit's node address, indicating the address of an IFEU, MRAU, or SRAU. |
| I32 irsRauAttenuatorId | 1.3.6.1.4.1.2014.20.1.1.1.3.3.1.4 | Integer32 | not-accessible | The RAU attenuator ID. These are consecutive integers starting at 1 and going up to the number of attenuators supported by the particular type of RAU. |
| NUM irsRauAttenuatorIntPath | 1.3.6.1.4.1.2014.20.1.1.1.3.3.1.5 | RauIntPathDir | read-only | The RAU internal path and direction to which the attenuator applies. |
| STR irsRauAttenuatorName | 1.3.6.1.4.1.2014.20.1.1.1.3.3.1.6 | DisplayString | read-only | A descriptive name of the attenuator including which bands, direction, and MIMO paths it may apply to, such as: Upper C 700, Lower ABC 700, Path 1 Fwd |
| I32 irsRauAttenuatorAttenuation | 1.3.6.1.4.1.2014.20.1.1.1.3.3.1.7 | Integer32 | read-write | Attenuator setting 0 or 10 in units of dB. |
| irsGeneralObjects | 1.3.6.1.4.1.2014.20.1.1.2 | |||
| irsSystemInfo | 1.3.6.1.4.1.2014.20.1.1.2.1 | |||
| STR irsAgentVersionNum | 1.3.6.1.4.1.2014.20.1.1.2.1.1 | DisplayString | read-only | The version of the SNMP subagent for the Spectrum IFEUs and RAUs. |
| irsSystemSettings | 1.3.6.1.4.1.2014.20.1.1.2.2 | |||
| INT irsRauAntennaDisconnectAlarmSeverity | 1.3.6.1.4.1.2014.20.1.1.2.2.1 | INTEGER | read-write | The RAUs' antenna disconnect alarm severity global setting. |
| irsNotificationObjects | 1.3.6.1.4.1.2014.20.1.1.99 | |||
| UNI irsNotifyUnitId1 | 1.3.6.1.4.1.2014.20.1.1.99.3 | UnitId1 | accessible-for-notify | The first portion of a unit's node address, indicating the host number. |
| UNI irsNotifyUnitId2 | 1.3.6.1.4.1.2014.20.1.1.99.4 | UnitId2 | accessible-for-notify | The second portion of a unit's node address, indicating the remote DART chassis address. |
| UNI irsNotifyUnitId3 | 1.3.6.1.4.1.2014.20.1.1.99.5 | UnitId3 | accessible-for-notify | The third portion of a unit's node address, indicating the address of an IFEU, MRAU, or SRAU. |
| UNI irsNotifyUnitType | 1.3.6.1.4.1.2014.20.1.1.99.6 | UnitType | accessible-for-notify | Unique ID for the notification. |
| irsNotifications | 1.3.6.1.4.1.2014.20.1.1.100 | |||
| irsIfeuNotifications | 1.3.6.1.4.1.2014.20.1.1.100.1 | |||
| irsIfeuNotificationsPrefix | 1.3.6.1.4.1.2014.20.1.1.100.1.0 | |||
| NTF irsIfeuPowerUpResetFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.1 | Unit was power-cycled. | ||
| NTF irsIfeuHwResetFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.2 | Unit was rebooted. | ||
| NTF irsIfeuWatchdogResetFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.3 | Software error occurred and recovered. | ||
| NTF irsIfeuSwResetFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.4 | Software reset occurred and recovered. | ||
| NTF irsIfeuExternalResetFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.5 | Microprocessor reset occurred and recovered. | ||
| NTF irsIfeuBrownoutResetFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.6 | Hardware error occurred and recovered. | ||
| NTF irsIfeuFwDnldFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.7 | Firmware download occurred successfully. | ||
| NTF irsIfeuMemoryErrorFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.8 | Firmware download failed checksum. Reverted to previous firmware version. | ||
| NTF irsIfeuFwdRefPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.9 | Forward reference PLL unlocked. | ||
| NTF irsIfeuFwdHighFreqPilotPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.10 | High frequency forward pilot PLL unlocked. | ||
| NTF irsIfeuFwdLowFreqPilotFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.11 | Hardware fault (Forward Pilot, Low Frequency). | ||
| NTF irsIfeuFwdHighFreqPilotFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.12 | Hardware fault (Forward Pilot, High Frequency). | ||
| NTF irsIfeuSoftwareIncompatibilityFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.17 | Firmware incompatible with system. | ||
| NTF irsIfeuBandFaultLockoutFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.19 | Band commanded shutdown due to major alarm in a unit that is upstream (closer to the Host). | ||
| NTF irsIfeuUnitCommandedLockoutFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.20 | IFEU commanded out-of-service by user. | ||
| NTF irsIfeuUnitFaultLockoutFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.21 | IFEU commanded shutdown due to major alarm in a unit that is upstream (closer to the Host). | ||
| NTF irsIfeuFwdBoardDisconnectedFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.25 | FWD Module not present. | ||
| NTF irsIfeuRevBoardDisconnectedFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.26 | REV Module not present. | ||
| NTF irsIfeuFwdBoardDcPowerBadFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.27 | FWD Module internal DC voltages outside of specification. | ||
| NTF irsIfeuRevBoardDcPowerBadFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.28 | REV Module internal DC voltages outside of specification. | ||
| NTF irsIfeuPowerCassette1FailureFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.33 | Power Supply Unit input fault on Power Rectifier Module #1. | ||
| NTF irsIfeuPowerCassette2FailureFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.34 | Power Supply Unit input fault on Power Rectifier Module #2. | ||
| NTF irsIfeuPowerCassette3FailureFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.35 | Power Supply Unit input fault on Power Rectifier Module #3. | ||
| NTF irsIfeuPowerCassette1HighTempFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.36 | Power Rectifier Module #1 shutdown due to high temperature. | ||
| NTF irsIfeuPowerCassette2HighTempFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.37 | Power Rectifier Module #2 shutdown due to high temperature. | ||
| NTF irsIfeuPowerCassette3HighTempFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.38 | Power Rectifier Module #3 shutdown due to high temperature. | ||
| NTF irsIfeuPort1DisconnectFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.129 | MRAU disconnected from port 1 of IFEU. | ||
| NTF irsIfeuPort2DisconnectFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.130 | MRAU disconnected from port 2 of IFEU. | ||
| NTF irsIfeuPort3DisconnectFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.131 | MRAU disconnected from port 3 of IFEU. | ||
| NTF irsIfeuPort4DisconnectFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.132 | MRAU disconnected from port 4 of IFEU. | ||
| NTF irsIfeuPort5DisconnectFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.133 | MRAU disconnected from port 5 of IFEU. | ||
| NTF irsIfeuPort6DisconnectFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.134 | MRAU disconnected from port 6 of IFEU. | ||
| NTF irsIfeuPort7DisconnectFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.135 | MRAU disconnected from port 7 of IFEU. | ||
| NTF irsIfeuPort8DisconnectFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.136 | MRAU disconnected from port 8 of IFEU. | ||
| NTF irsIfeuPort1NoCommsFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.137 | IFEU unable to communicate with MRAU on port 1. | ||
| NTF irsIfeuPort2NoCommsFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.138 | IFEU unable to communicate with MRAU on port 2. | ||
| NTF irsIfeuPort3NoCommsFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.139 | IFEU unable to communicate with MRAU on port 3. | ||
| NTF irsIfeuPort4NoCommsFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.140 | IFEU unable to communicate with MRAU on port 4. | ||
| NTF irsIfeuPort5NoCommsFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.141 | IFEU unable to communicate with MRAU on port 5. | ||
| NTF irsIfeuPort6NoCommsFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.142 | IFEU unable to communicate with MRAU on port 6. | ||
| NTF irsIfeuPort7NoCommsFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.143 | IFEU unable to communicate with MRAU on port 7. | ||
| NTF irsIfeuPort8NoCommsFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.144 | IFEU unable to communicate with MRAU on port 8. | ||
| NTF irsIfeuPort1ShortFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.145 | Possible electrical short in the CATV cable, or MRAU problem. | ||
| NTF irsIfeuPort2ShortFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.146 | Possible electrical short in the CATV cable, or MRAU problem. | ||
| NTF irsIfeuPort3ShortFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.147 | Possible electrical short in the CATV cable, or MRAU problem. | ||
| NTF irsIfeuPort4ShortFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.148 | Possible electrical short in the CATV cable, or MRAU problem. | ||
| NTF irsIfeuPort5ShortFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.149 | Possible electrical short in the CATV cable, or MRAU problem. | ||
| NTF irsIfeuPort6ShortFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.150 | Possible electrical short in the CATV cable, or MRAU problem. | ||
| NTF irsIfeuPort7ShortFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.151 | Possible electrical short in the CATV cable, or MRAU problem. | ||
| NTF irsIfeuPort8ShortFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.152 | Possible electrical short in the CATV cable, or MRAU problem. | ||
| NTF irsIfeuPort1TripFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.153 | MRAU on port 1 drawing too much current. | ||
| NTF irsIfeuPort2TripFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.154 | MRAU on port 2 drawing too much current. | ||
| NTF irsIfeuPort3TripFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.155 | MRAU on port 3 drawing too much current. | ||
| NTF irsIfeuPort4TripFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.156 | MRAU on port 4 drawing too much current. | ||
| NTF irsIfeuPort5TripFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.157 | MRAU on port 5 drawing too much current. | ||
| NTF irsIfeuPort6TripFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.158 | MRAU on port 6 drawing too much current. | ||
| NTF irsIfeuPort7TripFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.159 | MRAU on port 7 drawing too much current. | ||
| NTF irsIfeuPort8TripFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.160 | MRAU on port 8 drawing too much current. | ||
| NTF irsIfeuPort1FwdRevCoaxMisPairedFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.161 | Port 1 forward/reverse CATV cables not paired correctly. | ||
| NTF irsIfeuPort2FwdRevCoaxMisPairedFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.162 | Port 2 forward/reverse CATV cables not paired correctly. | ||
| NTF irsIfeuPort3FwdRevCoaxMisPairedFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.163 | Port 3 forward/reverse CATV cables not paired correctly. | ||
| NTF irsIfeuPort4FwdRevCoaxMisPairedFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.164 | Port 4 forward/reverse CATV cables not paired correctly. | ||
| NTF irsIfeuPort5FwdRevCoaxMisPairedFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.165 | Port 5 forward/reverse CATV cables not paired correctly. | ||
| NTF irsIfeuPort6FwdRevCoaxMisPairedFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.166 | Port 6 forward/reverse CATV cables not paired correctly | ||
| NTF irsIfeuPort7FwdRevCoaxMisPairedFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.167 | Port 7 forward/reverse CATV cables not paired correctly. | ||
| NTF irsIfeuPort8FwdRevCoaxMisPairedFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.168 | Port 8 forward/reverse CATV cables not paired correctly. | ||
| NTF irsIfeuPort1InvalidUnitTypeFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.169 | The unit connected to port 1 is not an MRAU. | ||
| NTF irsIfeuPort2InvalidUnitTypeFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.170 | The unit connected to port 2 is not an MRAU. | ||
| NTF irsIfeuPort3InvalidUnitTypeFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.171 | The unit connected to port 3 is not an MRAU. | ||
| NTF irsIfeuPort4InvalidUnitTypeFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.172 | The unit connected to port 4 is not an MRAU. | ||
| NTF irsIfeuPort5InvalidUnitTypeFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.173 | The unit connected to port 5 is not an MRAU. | ||
| NTF irsIfeuPort6InvalidUnitTypeFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.174 | The unit connected to port 6 is not an MRAU. | ||
| NTF irsIfeuPort7InvalidUnitTypeFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.175 | The unit connected to port 7 is not an MRAU. | ||
| NTF irsIfeuPort8InvalidUnitTypeFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.176 | The unit connected to port 8 is not an MRAU. | ||
| NTF irsIfeuNoCommsFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.257 | No communications with DRU. | ||
| NTF irsIfeuFwdBoardOverTempFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.258 | IFEU FWD Module temperature above operating limit. | ||
| NTF irsIfeuRevBoardOverTempFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.259 | IFEU REV Module temperature above operating limit. | ||
| NTF irsIfeuFan1FailureFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.260 | Fan 1 not functioning. | ||
| NTF irsIfeuFan2FailureFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.261 | Fan 2 not functioning. | ||
| NTF irsIfeuUnknownHwIdFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.262 | Unable to determine IFEU hardware configuration. | ||
| NTF irsIfeu5vDcFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.265 | Controller Module internal 5 VDC voltage outside of specification. | ||
| NTF irsIfeu24vDcFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.266 | Controller Module internal 24 VDC voltage outside of specification. | ||
| NTF irsIfeu3vDcFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.267 | Controller Module internal 3 VDC voltage outside of specification. | ||
| NTF irsIfeu6vDcFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.268 | Controller Module internal 6 VDC voltage outside of specification. | ||
| NTF irsIfeu54vDcFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.269 | Controller Module internal 54 VDC voltage outside of specification. | ||
| NTF irsIfeuPowerSupplyCommsFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.270 | Missing cable or communications error with Power Supply Unit. | ||
| NTF irsIfeuSystemOperationSuspendedFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.272 | System operation suspended (freeze mode). | ||
| NTF irsIfeuPort1FwdIfPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.273 | Hardware fault (Forward Pilot - Port 1). | ||
| NTF irsIfeuPort2FwdIfPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.274 | Hardware fault (Forward Pilot - Port 2). | ||
| NTF irsIfeuPort3FwdIfPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.275 | Hardware fault (Forward Pilot - Port 3). | ||
| NTF irsIfeuPort4FwdIfPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.276 | Hardware fault (Forward Pilot - Port 4). | ||
| NTF irsIfeuPort5FwdIfPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.277 | Hardware fault (Forward Pilot - Port 5). | ||
| NTF irsIfeuPort6FwdIfPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.278 | Hardware fault (Forward Pilot - Port 6). | ||
| NTF irsIfeuPort7FwdIfPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.279 | Hardware fault (Forward Pilot - Port 7). | ||
| NTF irsIfeuPort8FwdIfPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.280 | Hardware fault (Forward Pilot - Port 8). | ||
| NTF irsIfeuPort1CalToneNotPresentFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.281 | Calibration test tone not present (Port 1). | ||
| NTF irsIfeuPort2CalToneNotPresentFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.282 | Calibration test tone not present (Port 2). | ||
| NTF irsIfeuPort3CalToneNotPresentFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.283 | Calibration test tone not present (Port 3). | ||
| NTF irsIfeuPort4CalToneNotPresentFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.284 | Calibration test tone not present (Port 4). | ||
| NTF irsIfeuPort5CalToneNotPresentFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.285 | Calibration test tone not present (Port 5). | ||
| NTF irsIfeuPort6CalToneNotPresentFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.286 | Calibration test tone not present (Port 6). | ||
| NTF irsIfeuPort7CalToneNotPresentFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.287 | Calibration test tone not present (Port 7). | ||
| NTF irsIfeuPort8CalToneNotPresentFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.288 | Calibration test tone not present (Port 8). | ||
| NTF irsIfeuPort1RevLowFreqPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.289 | Reverse CATV cable RF loss too high (Port 1). | ||
| NTF irsIfeuPort2RevLowFreqPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.290 | Reverse CATV cable RF loss too high (Port 2). | ||
| NTF irsIfeuPort3RevLowFreqPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.291 | Reverse CATV cable RF loss too high (Port 3). | ||
| NTF irsIfeuPort4RevLowFreqPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.292 | Reverse CATV cable RF loss too high (Port 4). | ||
| NTF irsIfeuPort5RevLowFreqPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.293 | Reverse CATV cable RF loss too high (Port 5). | ||
| NTF irsIfeuPort6RevLowFreqPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.294 | Reverse CATV cable RF loss too high (Port 6). | ||
| NTF irsIfeuPort7RevLowFreqPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.295 | Reverse CATV cable RF loss too high (Port 7). | ||
| NTF irsIfeuPort8RevLowFreqPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.296 | Reverse CATV cable RF loss too high (Port 8). | ||
| NTF irsIfeuPort1RevHighFreqPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.297 | Reverse CATV cable RF loss too high (Port 1). | ||
| NTF irsIfeuPort2RevHighFreqPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.298 | Reverse CATV cable RF loss too high (Port 2). | ||
| NTF irsIfeuPort3RevHighFreqPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.299 | Reverse CATV cable RF loss too high (Port 3). | ||
| NTF irsIfeuPort4RevHighFreqPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.300 | Reverse CATV cable RF loss too high (Port 4). | ||
| NTF irsIfeuPort5RevHighFreqPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.301 | Reverse CATV cable RF loss too high (Port 5). | ||
| NTF irsIfeuPort6RevHighFreqPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.302 | Reverse CATV cable RF loss too high (Port 6). | ||
| NTF irsIfeuPort7RevHighFreqPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.303 | Reverse CATV cable RF loss too high (Port 7). | ||
| NTF irsIfeuPort8RevHighFreqPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.304 | Reverse CATV cable RF loss too high (Port 8). | ||
| NTF irsIfeuPort1RevLowFreqPilotHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.305 | Reverse RF path exceeds maximum gain (Port 1). | ||
| NTF irsIfeuPort2RevLowFreqPilotHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.306 | Reverse RF path exceeds maximum gain (Port 2). | ||
| NTF irsIfeuPort3RevLowFreqPilotHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.307 | Reverse RF path exceeds maximum gain (Port 3). | ||
| NTF irsIfeuPort4RevLowFreqPilotHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.308 | Reverse RF path exceeds maximum gain (Port 4). | ||
| NTF irsIfeuPort5RevLowFreqPilotHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.309 | Reverse RF path exceeds maximum gain (Port 5). | ||
| NTF irsIfeuPort6RevLowFreqPilotHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.310 | Reverse RF path exceeds maximum gain (Port 6). | ||
| NTF irsIfeuPort7RevLowFreqPilotHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.311 | Reverse RF path exceeds maximum gain (Port 7). | ||
| NTF irsIfeuPort8RevLowFreqPilotHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.312 | Reverse RF path exceeds maximum gain (Port 8). | ||
| NTF irsIfeuPort1RevHighFreqPilotHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.313 | Reverse RF path exceeds maximum gain (Port 1). | ||
| NTF irsIfeuPort2RevHighFreqPilotHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.314 | Reverse RF path exceeds maximum gain (Port 2). | ||
| NTF irsIfeuPort3RevHighFreqPilotHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.315 | Reverse RF path exceeds maximum gain (Port 3). | ||
| NTF irsIfeuPort4RevHighFreqPilotHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.316 | Reverse RF path exceeds maximum gain (Port 4). | ||
| NTF irsIfeuPort5RevHighFreqPilotHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.317 | Reverse RF path exceeds maximum gain (Port 5). | ||
| NTF irsIfeuPort6RevHighFreqPilotHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.318 | Reverse RF path exceeds maximum gain (Port 6). | ||
| NTF irsIfeuPort7RevHighFreqPilotHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.319 | Reverse RF path exceeds maximum gain (Port 7). | ||
| NTF irsIfeuPort8RevHighFreqPilotHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.320 | Reverse RF path exceeds maximum gain (Port 8). | ||
| NTF irsIfeuPort1FwdCurrentHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.321 | Forward CATV cable current exceeds specification (Port 1). | ||
| NTF irsIfeuPort2FwdCurrentHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.322 | Forward CATV cable current exceeds specification (Port 2). | ||
| NTF irsIfeuPort3FwdCurrentHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.323 | Forward CATV cable current exceeds specification (Port 3). | ||
| NTF irsIfeuPort4FwdCurrentHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.324 | Forward CATV cable current exceeds specification (Port 4). | ||
| NTF irsIfeuPort5FwdCurrentHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.325 | Forward CATV cable current exceeds specification (Port 5). | ||
| NTF irsIfeuPort6FwdCurrentHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.326 | Forward CATV cable current exceeds specification (Port 6). | ||
| NTF irsIfeuPort7FwdCurrentHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.327 | Forward CATV cable current exceeds specification (Port 7). | ||
| NTF irsIfeuPort8FwdCurrentHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.328 | Forward CATV cable current exceeds specification (Port 8). | ||
| NTF irsIfeuPort1RevCurrentHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.329 | Reverse CATV cable current exceeds specification (Port 1). | ||
| NTF irsIfeuPort2RevCurrentHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.330 | Reverse CATV cable current exceeds specification (Port 2). | ||
| NTF irsIfeuPort3RevCurrentHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.331 | Reverse CATV cable current exceeds specification (Port 3). | ||
| NTF irsIfeuPort4RevCurrentHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.332 | Reverse CATV cable current exceeds specification (Port 4). | ||
| NTF irsIfeuPort5RevCurrentHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.333 | Reverse CATV cable current exceeds specification (Port 5). | ||
| NTF irsIfeuPort6RevCurrentHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.334 | Reverse CATV cable current exceeds specification (Port 6). | ||
| NTF irsIfeuPort7RevCurrentHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.335 | Reverse CATV cable current exceeds specification (Port 7). | ||
| NTF irsIfeuPort8RevCurrentHighFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.336 | Reverse CATV cable current exceeds specification (Port 8). | ||
| NTF irsIfeuCassette1HighTempFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.337 | Power Supply Unit temperature above operating limit (Power Rectifier Module #1). | ||
| NTF irsIfeuCassette1OutputBadFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.338 | Power Supply Unit output voltage outside specification (Power Rectifier Module #1). | ||
| NTF irsIfeuCassette1Fan1Fault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.339 | Power Supply Unit fan #1 not functioning (Power Rectifier Module #1). | ||
| NTF irsIfeuCassette1Fan2Fault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.340 | Power Supply Unit fan #2 not functioning (Power Rectifier Module #1). | ||
| NTF irsIfeuCassette1Fan3Fault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.341 | Power Supply Unit fan #3 not functioning (Power Rectifier Module #1). | ||
| NTF irsIfeuCassette1Unused | 1.3.6.1.4.1.2014.20.1.1.100.1.0.342 | Power Rectifier Module is present but not powered on. | ||
| NTF irsIfeuCassette1HighLoadingFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.344 | Power Supply Unit load high (Power Rectifier Module #1). | ||
| NTF irsIfeuCassette2HighTempFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.345 | Power Supply Unit temperature above operating limit (Power Rectifier Module #2). | ||
| NTF irsIfeuCassette2OutputBadFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.346 | Power Supply Unit output voltage outside specification (Power Rectifier Module #2). | ||
| NTF irsIfeuCassette2Fan1Fault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.347 | Power Supply Unit fan #1 not functioning (Power Rectifier Module #2). | ||
| NTF irsIfeuCassette2Fan2Fault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.348 | Power Supply Unit fan #2 not functioning (Power Rectifier Module #2). | ||
| NTF irsIfeuCassette2Fan3Fault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.349 | Power Supply Unit fan #3 not functioning (Power Rectifier Module #2). | ||
| NTF irsIfeuCassette2Unused | 1.3.6.1.4.1.2014.20.1.1.100.1.0.350 | Power Rectifier Module is present but not powered on. | ||
| NTF irsIfeuCassette2HighLoadingFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.352 | Power Supply Unit load high (Power Rectifier Module #2). | ||
| NTF irsIfeuCassette3HighTempFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.353 | Power Supply Unit temperature above operating limit (Power Rectifier Module #3). | ||
| NTF irsIfeuCassette3OutputBadFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.354 | Power Supply Unit output voltage outside specification (Power Rectifier Module #3). | ||
| NTF irsIfeuCassette3Fan1Fault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.355 | Power Supply Unit fan #1 not functioning (Power Rectifier Module #3). | ||
| NTF irsIfeuCassette3Fan2Fault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.356 | Power Supply Unit fan #2 not functioning (Power Rectifier Module #3). | ||
| NTF irsIfeuCassette3Fan3Fault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.357 | Power Supply Unit fan #3 not functioning (Power Rectifier Module #3). | ||
| NTF irsIfeuCassette3Unused | 1.3.6.1.4.1.2014.20.1.1.100.1.0.358 | Power Rectifier Module is present but not powered on. | ||
| NTF irsIfeuCassette3HighLoadingFault | 1.3.6.1.4.1.2014.20.1.1.100.1.0.360 | Power Supply Unit load high (Power Rectifier Module #3). | ||
| irsRauNotifications | 1.3.6.1.4.1.2014.20.1.1.100.2 | |||
| irsRauNotificationsPrefix | 1.3.6.1.4.1.2014.20.1.1.100.2.0 | |||
| NTF irsRauPowerUpResetFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.1 | Unit was power-cycled. | ||
| NTF irsRauHwResetFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.2 | Unit was rebooted. | ||
| NTF irsRauWatchdogResetFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.3 | Software error occurred and recovered. | ||
| NTF irsRauSwResetFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.4 | Software reset occurred and recovered. | ||
| NTF irsRauExternalResetFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.5 | Microprocessor reset occurred and recovered. | ||
| NTF irsRauBrownoutResetFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.6 | Hardware error occurred and recovered. | ||
| NTF irsRauFwDnldFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.7 | Firmware download occurred successfully. | ||
| NTF irsRauMemoryErrorFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.8 | Firmware download failed checksum. Reverted to previous firmware version. | ||
| NTF irsRauRevLowFreqPilotFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.9 | Hardware fault (Reverse Pilot, Low Frequency). | ||
| NTF irsRauRevHighFreqPilotFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.10 | Hardware fault (Reverse Pilot, High Frequency). | ||
| NTF irsRauRfCableDisconnect1Fault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.11 | External RF SMA cable 1 disconnected. | ||
| NTF irsRauRfCableDisconnect2Fault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.12 | External RF SMA cable 2 disconnected (Future tri-band units). | ||
| NTF irsRauAntennaDisconnectPort1Fault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.13 | Antenna disconnected (Band 1). | ||
| NTF irsRauAntennaDisconnectPort2Fault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.14 | Antenna disconnected (Band 2). | ||
| NTF irsRauSoftwareIncompatibilityFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.17 | Firmware incompatible with system. | ||
| NTF irsRauIncompatibleBandsFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.18 | RAU frequencies not compatible with configured DART links. | ||
| NTF irsRauDcVoltageLowFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.19 | RAU input voltage below specified limit. | ||
| NTF irsRauUnitComandedLockoutFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.20 | RAU commanded out-of-service by user. | ||
| NTF irsRauUnitFaultLockoutFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.21 | RAU commanded shutdown due to major alarm in a unit that is upstream (closer to the Host). | ||
| NTF irsRauCantPowerUpSrauFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.22 | DC Voltage too low to power up SRAUs. | ||
| NTF irsRauBandPath1AFwdPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.25 | Hardware fault (Forward RF Path PLL). | ||
| NTF irsRauBandPath2AFwdPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.26 | Hardware fault (Forward RF Path PLL). | ||
| NTF irsRauBandPath3AFwdPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.27 | Hardware fault (Forward RF Path PLL). | ||
| NTF irsRauBandPath1BFwdPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.28 | Hardware fault (Forward RF Path PLL). | ||
| NTF irsRauBandPath2BFwdPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.29 | Hardware fault (Forward RF Path PLL). | ||
| NTF irsRauBandPath3BFwdPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.30 | Hardware fault (Forward RF Path PLL). | ||
| NTF irsRauBandPath1ARevPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.33 | Hardware fault (Reverse RF Path PLL). | ||
| NTF irsRauBandPath2ARevPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.34 | Hardware fault (Reverse RF Path PLL). | ||
| NTF irsRauBandPath3ARevPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.35 | Hardware fault (Reverse RF Path PLL). | ||
| NTF irsRauBandPath1BRevPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.36 | Hardware fault (Reverse RF Path PLL). | ||
| NTF irsRauBandPath2BRevPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.37 | Hardware fault (Reverse RF Path PLL). | ||
| NTF irsRauBandPath3BRevPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.38 | Hardware fault (Reverse RF Path PLL). | ||
| NTF irsRauBandPath1AFwdPowerAmpFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.41 | Hardware fault (Power Amplifier). | ||
| NTF irsRauBandPath2AFwdPowerAmpFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.42 | Hardware fault (Power Amplifier). | ||
| NTF irsRauBandPath3AFwdPowerAmpFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.43 | Hardware fault (Power Amplifier). | ||
| NTF irsRauBandPath1BFwdPowerAmpFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.44 | Hardware fault (Power Amplifier). | ||
| NTF irsRauBandPath2BFwdPowerAmpFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.45 | Hardware fault (Power Amplifier). | ||
| NTF irsRauBandPath3BFwdPowerAmpFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.46 | Hardware fault (Power Amplifier). | ||
| NTF irsRauBandPath1ABandCommandedLockoutFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.49 | Band commanded out-of-service by user. | ||
| NTF irsRauBandPath2ABandCommandedLockoutFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.50 | Band commanded out-of-service by user. | ||
| NTF irsRauBandPath3ABandCommandedLockoutFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.51 | Band commanded out-of-service by user. | ||
| NTF irsRauBandPath1BBandCommandedLockoutFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.52 | Band commanded out-of-service by user. | ||
| NTF irsRauBandPath2BBandCommandedLockoutFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.53 | Band commanded out-of-service by user. | ||
| NTF irsRauBandPath3BBandCommandedLockoutFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.54 | Band commanded out-of-service by user. | ||
| NTF irsRauBandPath1ABandFaultLockoutFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.57 | Band commanded shutdown due to major alarm in a unit that is upstream (closer to the Host). | ||
| NTF irsRauBandPath2ABandFaultLockoutFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.58 | Band commanded shutdown due to major alarm in a unit that is upstream (closer to the Host). | ||
| NTF irsRauBandPath3ABandFaultLockoutFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.59 | Band commanded shutdown due to major alarm in a unit that is upstream (closer to the Host). | ||
| NTF irsRauBandPath1BBandFaultLockoutFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.60 | Band commanded shutdown due to major alarm in a unit that is upstream (closer to the Host). | ||
| NTF irsRauBandPath2BBandFaultLockoutFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.61 | Band commanded shutdown due to major alarm in a unit that is upstream (closer to the Host). | ||
| NTF irsRauBandPath3BBandFaultLockoutFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.62 | Band commanded shutdown due to major alarm in a unit that is upstream (closer to the Host). | ||
| NTF irsRauPort1DisconnectFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.129 | SRAU disconnected from port 1 of MRAU. | ||
| NTF irsRauPort2DisconnectFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.130 | SRAU disconnected from port 2 of MRAU. | ||
| NTF irsRauPort3DisconnectFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.131 | SRAU disconnected from port 3 of MRAU. | ||
| NTF irsRauPort1NoCommsFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.137 | MRAU unable to communicate with SRAU on port 1. | ||
| NTF irsRauPort2NoCommsFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.138 | MRAU unable to communicate with SRAU on port 2. | ||
| NTF irsRauPort3NoCommsFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.139 | MRAU unable to communicate with SRAU on port 3. | ||
| NTF irsRauPort1ShortFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.145 | Possible electrical short in the CATV cable, or SRAU problem. | ||
| NTF irsRauPort2ShortFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.146 | Possible electrical short in the coax cable, or SRAU problem. | ||
| NTF irsRauPort3ShortFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.147 | Possible electrical short in the coax cable, or SRAU problem. | ||
| NTF irsRauPort1TripFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.153 | SRAU on port 1 drawing too much current. | ||
| NTF irsRauPort2TripFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.154 | SRAU on port 2 drawing too much current. | ||
| NTF irsRauPort3TripFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.155 | SRAU on port 3 drawing too much current. | ||
| NTF irsRauPort1FwdRevCoaxMisPairedFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.161 | Port 1 forward/reverse CATV cables not paired correctly. | ||
| NTF irsRauPort2FwdRevCoaxMisPairedFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.162 | Port 2 forward/reverse CATV cables not paired correctly. | ||
| NTF irsRauPort3FwdRevCoaxMisPairedFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.163 | Port 3 forward/reverse CATV cables not paired correctly. | ||
| NTF irsRauPort1InvalidUnitTypeFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.169 | The unit connected to port 1 is not an SRAU. | ||
| NTF irsRauPort2InvalidUnitTypeFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.170 | The unit connected to port 2 is not an SRAU. | ||
| NTF irsRauPort3InvalidUnitTypeFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.171 | The unit connected to port 3 is not an SRAU. | ||
| NTF irsRauNoCommsFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.257 | No communications from IFEU or MRAU. | ||
| NTF irsRauHighTempFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.258 | RAU temperature above operating limit. | ||
| NTF irsRauFwdLowFreqPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.259 | Forward CATV cable RF loss too high. | ||
| NTF irsRauFwdHighFreqPilotLowFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.260 | Forward CATV cable RF loss too high. | ||
| NTF irsRauFwdLowFreqPilotHighFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.261 | Forward RF path exceeds maximum gain. | ||
| NTF irsRauFwdHighFreqPilotHighFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.262 | Forward RF path exceeds maximum gain. | ||
| NTF irsRauRevFdFailureFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.263 | Reverse RF path problem in the MRAU. Unable to complete reverse system end-to-end test. | ||
| NTF irsRauUnknownHwIdFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.264 | Unable to determine RAU hardware configuration. | ||
| NTF irsRauRfCable1DisconnectFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.267 | External RF SMA cable 1 disconnected. | ||
| NTF irsRauRfCable2DisconnectFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.268 | External RF SMA cable 2 disconnected (Future tri-band units). | ||
| NTF irsRauAntennaPort1DisconnectFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.269 | Antenna disconnected (Band 1). | ||
| NTF irsRauAntennaPort2DisconnectFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.270 | Antenna disconnected (Band 2). | ||
| NTF irsRauSystemOperationSuspendedFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.272 | System operation suspended (freeze mode). | ||
| NTF irsRauBandPath1ASysTestRequiredFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.273 | System test has not been executed on this RF band. | ||
| NTF irsRauBandPath2ASysTestRequiredFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.274 | System test has not been executed on this RF band. | ||
| NTF irsRauBandPath3ASysTestRequiredFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.275 | System test has not been executed on this RF band. | ||
| NTF irsRauBandPath1BSysTestRequiredFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.276 | System test has not been executed on this RF band. | ||
| NTF irsRauBandPath2BSysTestRequiredFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.277 | System test has not been executed on this RF band. | ||
| NTF irsRauBandPath3BSysTestRequiredFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.278 | System test has not been executed on this RF band. | ||
| NTF irsRauBandPath1AFwdSysTestNotCompletedFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.281 | System end-to-end test failed on forward path. | ||
| NTF irsRauBandPath2AFwdSysTestNotCompletedFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.282 | System end-to-end test failed on forward path. | ||
| NTF irsRauBandPath3AFwdSysTestNotCompletedFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.283 | System end-to-end test failed on forward path. | ||
| NTF irsRauBandPath1BFwdSysTestNotCompletedFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.284 | System end-to-end test failed on forward path. | ||
| NTF irsRauBandPath2BFwdSysTestNotCompletedFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.285 | System end-to-end test failed on forward path. | ||
| NTF irsRauBandPath3BFwdSysTestNotCompletedFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.286 | System end-to-end test failed on forward path. | ||
| NTF irsRauBandPath1ARevPathFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.289 | System end-to-end test failed on reverse path. | ||
| NTF irsRauBandPath2ARevPathFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.290 | System end-to-end test failed on reverse path. | ||
| NTF irsRauBandPath3ARevPathFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.291 | System end-to-end test failed on reverse path. | ||
| NTF irsRauBandPath1BRevPathFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.292 | System end-to-end test failed on reverse path. | ||
| NTF irsRauBandPath2BRevPathFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.293 | System end-to-end test failed on reverse path. | ||
| NTF irsRauBandPath3BRevPathFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.294 | System end-to-end test failed on reverse path. | ||
| NTF irsRauBandPath1ARevFdPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.297 | Unable to generate reverse test tone. | ||
| NTF irsRauBandPath2ARevFdPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.298 | Unable to generate reverse test tone. | ||
| NTF irsRauBandPath3ARevFdPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.299 | Unable to generate reverse test tone. | ||
| NTF irsRauBandPath1BRevFdPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.300 | Unable to generate reverse test tone. | ||
| NTF irsRauBandPath2BRevFdPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.301 | Unable to generate reverse test tone. | ||
| NTF irsRauBandPath3BRevFdPllUnlockFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.302 | Unable to generate reverse test tone. | ||
| NTF irsRauBandPath1AFwdSysTestBlockedFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.305 | Unable to execute FWD system test due to detection of external signal in the same band at the RAU. | ||
| NTF irsRauBandPath2AFwdSysTestBlockedFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.306 | Unable to execute FWD system test due to detection of external signal in the same band at the RAU. | ||
| NTF irsRauBandPath3AFwdSysTestBlockedFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.307 | Unable to execute FWD system test due to detection of external signal in the same band at the RAU. | ||
| NTF irsRauBandPath1BFwdSysTestBlockedFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.308 | Unable to execute FWD system test due to detection of external signal in the same band at the RAU. | ||
| NTF irsRauBandPath2BFwdSysTestBlockedFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.309 | Unable to execute FWD system test due to detection of external signal in the same band at the RAU. | ||
| NTF irsRauBandPath3BFwdSysTestBlockedFault | 1.3.6.1.4.1.2014.20.1.1.100.2.0.310 | Unable to execute FWD system test due to detection of external signal in the same band at the RAU. | ||
| irsMIBConformance | 1.3.6.1.4.1.2014.20.1.1.200 | |||
| irsMIBCompliances | 1.3.6.1.4.1.2014.20.1.1.200.1 | |||
| irsBasicCompliance | 1.3.6.1.4.1.2014.20.1.1.200.1.1 | The compliance statement for InterReach Spectrum entities which implement the ADC-INTERREACH-SPECTRUM-MIB. | ||
| irsMIBGroups | 1.3.6.1.4.1.2014.20.1.1.200.2 | |||
| irsUnitObjectsGroup | 1.3.6.1.4.1.2014.20.1.1.200.2.1 | A collection of objects providing unit related instrumentation and control of an agent. | ||
| irsNotificationObjectsGroup | 1.3.6.1.4.1.2014.20.1.1.200.2.2 | This is the minimum set of objects required in order to support the irsNotificationObjects group. | ||
| irsNotificationsGroup | 1.3.6.1.4.1.2014.20.1.1.200.2.3 | A collection of notifications. |
RFC description
Vendor-private MIB for ADC (Applied Digital Computing) Interreach Spectrum product managing application delivery and network performance metrics.
Start monitoring ADC InterReach Spectrum DAS units with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.