ADC-INTERREACH-SPECTRUM-MIB :: irsUnitGenUpTime

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ADC-INTERREACH-SPECTRUM-MIB › irsUnitGenUpTime

irsUnitGenUpTime

Module: ADC-INTERREACH-SPECTRUM-MIB

OID (symbolic): ADC-INTERREACH-SPECTRUM-MIB::irsUnitGenUpTime

OID (numeric): 1.3.6.1.4.1.2014.20.1.1.1.2.1.11

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The time in seconds since the unit last started up.

What is irsUnitGenUpTime?

This OID tracks the number of seconds elapsed since the unit last booted up, acting as a counter that reveals reboot history and stability patterns. If uptime is consistently low or resets unexpectedly, it signals underlying problems such as hardware failures, power issues, or software crashes that need investigation. A value of '86400' means the unit has been running for exactly one day, so a sudden drop to '100' indicates an unplanned reboot has occurred.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2014.20.1.1.1.2.1.11
snmpwalk -v2c -c public <target> ADC-INTERREACH-SPECTRUM-MIB::irsUnitGenUpTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2014.20.1.1.1.2.1.11.1
snmpget -v2c -c public <target> ADC-INTERREACH-SPECTRUM-MIB::irsUnitGenUpTime.1

Start monitoring ADC InterReach Spectrum DAS units with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADC-INTERREACH-SPECTRUM-MIB::irsUnitGenUpTime OID value, configure state conditions and alerts, and monitor any ADC InterReach Spectrum DAS units from a single console.

How to Use in IPNetwork Monitor

Select an ADC InterReach Spectrum DAS unit as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type irsUnitGenUpTime into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The time in seconds since the unit last started up. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the value is unexpectedly low (e.g. under 10 minutes), since that indicates a recent, possibly unplanned, reboot or restart. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2014adcADC-FLEXWAVE-URH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2014.20interReachADC-INTERREACH-SPECTRUM-MIB
1.3.6.1.4.1.2014.20.1interReachSpectrumADC-INTERREACH-SPECTRUM-MIB
1.3.6.1.4.1.2014.20.1.1interReachSpectrumMibModuleADC-INTERREACH-SPECTRUM-MIB
1.3.6.1.4.1.2014.20.1.1.1irsUnitObjectsADC-INTERREACH-SPECTRUM-MIB
1.3.6.1.4.1.2014.20.1.1.1.2irsUnitGenTableADC-INTERREACH-SPECTRUM-MIB
1.3.6.1.4.1.2014.20.1.1.1.2.1irsUnitGenEntryADC-INTERREACH-SPECTRUM-MIB
1.3.6.1.4.1.2014.20.1.1.1.2.1.11irsUnitGenUpTimeADC-INTERREACH-SPECTRUM-MIB