All MIBs › WebGraph-Thermometer-US-MIB
Category: Power and Environmental Monitoring
Description: Monitors WebGraph thermometer sensor current temperature readings and configurable high and low alarm thresholds.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is WebGraph-Thermometer-US-MIB?
This is a proprietary MIB for a WebGraph-branded networked thermometer sensor appliance, apparently an OEM/rebranded unit given its "Webio" internal object prefix, used to track ambient temperature at a monitored location such as a server room or equipment cabinet. It exposes hardware sensor data through a per-sensor table of current temperature values along with a binary threshold-alarm indicator, plus session-control objects (password, configuration mode) for securing device configuration changes. Being a pure environmental sensor MIB, its core function is hardware status monitoring, reporting current temperature and flagging when a configurable high/low alarm threshold has been crossed, essential for detecting cooling failures or environmental excursions that could damage nearby IT equipment. It is a small self-contained proprietary schema with no apparent dependency on other MIBs. It is deployed on standalone WebGraph/Webio networked temperature-probe appliances placed in data closets, cabinets, or rooms requiring environmental monitoring. Network engineers evaluating or troubleshooting this functionality can download the WebGraph-Thermometer-US-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in WebGraph-Thermometer-US-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- WebGraph/Webio networked thermometer sensor appliance
Monitoring Examples
An operator would poll wtWebioAn1GraphSensorTable (via wtWebioAn1GraphSensorEntry/wtWebioAn1GraphSensorNo) to identify each configured sensor, then read the current reading from wtWebioAn1GraphTempValueTable's wtWebioAn1GraphTempValue. If wtWebioAn1GraphBinaryTempValueTable's wtWebioAn1GraphBinaryTempValue shows the alarm bit set, that indicates the sensor has crossed its configured high or low temperature threshold, prompting investigation of a possible air-conditioning failure in the monitored space.
What Can Be Monitored
- current temperature reading per sensor
- high/low temperature alarm threshold status
- sensor index/count
- device session/config-mode status
This MIB depends on
Related MIBs
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| IpAddress | |
| NetworkAddress | |
| TimeTicks | |
| enterprises |
From RFC1213-MIB
| DisplayString | |
| PhysAddress |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| wut | 1.3.6.1.4.1.5040 | |||
| wtComServer | 1.3.6.1.4.1.5040.1 | |||
| wtWebio | 1.3.6.1.4.1.5040.1.2 | |||
| wtWebioAn1Graph | 1.3.6.1.4.1.5040.1.2.8 | |||
| NTF wtWebioAn1GraphAlert1 | 1.3.6.1.4.1.5040.1.2.8.0.31 | This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn1GraphAlert2 | 1.3.6.1.4.1.5040.1.2.8.0.32 | This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn1GraphAlert3 | 1.3.6.1.4.1.5040.1.2.8.0.33 | This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn1GraphAlert4 | 1.3.6.1.4.1.5040.1.2.8.0.34 | This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn1GraphAlert5 | 1.3.6.1.4.1.5040.1.2.8.0.35 | This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn1GraphAlert6 | 1.3.6.1.4.1.5040.1.2.8.0.36 | This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn1GraphAlert7 | 1.3.6.1.4.1.5040.1.2.8.0.37 | This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn1GraphAlert8 | 1.3.6.1.4.1.5040.1.2.8.0.38 | This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn1GraphAlert9 | 1.3.6.1.4.1.5040.1.2.8.0.91 | This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn1GraphAlert10 | 1.3.6.1.4.1.5040.1.2.8.0.92 | This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn1GraphAlert11 | 1.3.6.1.4.1.5040.1.2.8.0.93 | This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn1GraphAlert12 | 1.3.6.1.4.1.5040.1.2.8.0.94 | This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn1GraphAlert13 | 1.3.6.1.4.1.5040.1.2.8.0.95 | This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn1GraphAlert14 | 1.3.6.1.4.1.5040.1.2.8.0.96 | This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn1GraphAlert15 | 1.3.6.1.4.1.5040.1.2.8.0.97 | This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn1GraphAlert16 | 1.3.6.1.4.1.5040.1.2.8.0.98 | This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn1GraphAlertDiag | 1.3.6.1.4.1.5040.1.2.8.0.110 | This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| wtWebioAn1GraphTemp | 1.3.6.1.4.1.5040.1.2.8.1 | |||
| INT wtWebioAn1GraphSensors | 1.3.6.1.4.1.5040.1.2.8.1.1 | INTEGER | read-only | Number of temperature sensors |
| wtWebioAn1GraphSensorTable | 1.3.6.1.4.1.5040.1.2.8.1.2 | not-accessible | List of sensors. | |
| wtWebioAn1GraphSensorEntry | 1.3.6.1.4.1.5040.1.2.8.1.2.1 | not-accessible | Temperature sensor numbers. | |
| INT wtWebioAn1GraphSensorNo | 1.3.6.1.4.1.5040.1.2.8.1.2.1.1 | INTEGER | read-only | Temperature sensor number. |
| wtWebioAn1GraphTempValueTable | 1.3.6.1.4.1.5040.1.2.8.1.3 | not-accessible | List of temperature values corresponding to the channel numbers. | |
| wtWebioAn1GraphTempValueEntry | 1.3.6.1.4.1.5040.1.2.8.1.3.1 | not-accessible | Temperatures of the sensors. | |
| OCT wtWebioAn1GraphTempValue | 1.3.6.1.4.1.5040.1.2.8.1.3.1.1 | OCTET STRING | read-only | Temperature value of the sensor, ASCII, 5 characters in length. |
| wtWebioAn1GraphBinaryTempValueTable | 1.3.6.1.4.1.5040.1.2.8.1.4 | not-accessible | List of binary temperature values corresponding to the channel numbers. | |
| wtWebioAn1GraphBinaryTempValueEntry | 1.3.6.1.4.1.5040.1.2.8.1.4.1 | not-accessible | Binary temperature values of the sensors. | |
| INT wtWebioAn1GraphBinaryTempValue | 1.3.6.1.4.1.5040.1.2.8.1.4.1.1 | INTEGER | read-only | Binary temperature value of the sensor in 1/10 degrees Celsius, signed number, 0x7FFF indicates an invalid measured value. |
| wtWebioAn1GraphSessCntrl | 1.3.6.1.4.1.5040.1.2.8.2 | |||
| OCT wtWebioAn1GraphSessCntrlPassword | 1.3.6.1.4.1.5040.1.2.8.2.1 | OCTET STRING | read-write | Entering this password opens a session which is ended by writing a 1 to wtWebioAn1GraphSessCntrlLogout. When read this variable provides a string of length zero. |
| INT wtWebioAn1GraphSessCntrlConfigMode | 1.3.6.1.4.1.5040.1.2.8.2.2 | INTEGER | read-only | When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read. |
| INT wtWebioAn1GraphSessCntrlLogout | 1.3.6.1.4.1.5040.1.2.8.2.3 | INTEGER | read-write | If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0. |
| OCT wtWebioAn1GraphSessCntrlAdminPassword | 1.3.6.1.4.1.5040.1.2.8.2.4 | OCTET STRING | read-write | This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public. |
| OCT wtWebioAn1GraphSessCntrlConfigPassword | 1.3.6.1.4.1.5040.1.2.8.2.5 | OCTET STRING | read-write | This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer. |
| wtWebioAn1GraphConfig | 1.3.6.1.4.1.5040.1.2.8.3 | |||
| wtWebioAn1GraphDevice | 1.3.6.1.4.1.5040.1.2.8.3.1 | |||
| wtWebioAn1GraphText | 1.3.6.1.4.1.5040.1.2.8.3.1.1 | |||
| OCT wtWebioAn1GraphDeviceName | 1.3.6.1.4.1.5040.1.2.8.3.1.1.1 | OCTET STRING | read-write | Name of the Webio, which is user definable. |
| OCT wtWebioAn1GraphDeviceText | 1.3.6.1.4.1.5040.1.2.8.3.1.1.2 | OCTET STRING | read-write | Description of the Webio, which is user definable. |
| OCT wtWebioAn1GraphDeviceLocation | 1.3.6.1.4.1.5040.1.2.8.3.1.1.3 | OCTET STRING | read-write | Description of the location of the Webio, which is user definable. |
| OCT wtWebioAn1GraphDeviceContact | 1.3.6.1.4.1.5040.1.2.8.3.1.1.4 | OCTET STRING | read-write | Contact address of the system operator of the Webio, which is user definable. |
| wtWebioAn1GraphTimeDate | 1.3.6.1.4.1.5040.1.2.8.3.1.2 | |||
| wtWebioAn1GraphTimeZone | 1.3.6.1.4.1.5040.1.2.8.3.1.2.1 | |||
| INT wtWebioAn1GraphTzOffsetHrs | 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.1 | INTEGER | read-write | Offset hours for the time zone (winter time) with respect to UTC. |
| INT wtWebioAn1GraphTzOffsetMin | 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.2 | INTEGER | read-write | Offset minutes for the time zone (winter time) with respect to UTC. |
| OCT wtWebioAn1GraphTzEnable | 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.3 | OCTET STRING | read-write | Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone |
| INT wtWebioAn1GraphStTzOffsetHrs | 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.4 | INTEGER | read-write | Offset hours of the time zone (summer time) with respect to UTC. |
| INT wtWebioAn1GraphStTzOffsetMin | 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.5 | INTEGER | read-write | Offset minutes of the time zone (summer time) with respect to UTC. |
| OCT wtWebioAn1GraphStTzEnable | 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.6 | OCTET STRING | read-write | Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime |
| INT wtWebioAn1GraphStTzStartMonth | 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.7 | INTEGER | read-write | Month in which the change is made from winter time to summer time. |
| INT wtWebioAn1GraphStTzStartMode | 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.8 | INTEGER | read-write | Mode of the day of the week for which the change is made from winter time to summer time. |
| INT wtWebioAn1GraphStTzStartWday | 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.9 | INTEGER | read-write | Day of the week on which the change is made from winter time to summer time |
| INT wtWebioAn1GraphStTzStartHrs | 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.10 | INTEGER | read-write | Hour in which the time zone is changed from winter to summer time with respect to UTC. |
| INT wtWebioAn1GraphStTzStartMin | 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.11 | INTEGER | read-write | Minute in which the time zone is changed from winter to summer time with respect to UTC. |
| INT wtWebioAn1GraphStTzStopMonth | 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.12 | INTEGER | read-write | Month in which the change is made from summer time to winter time. |
| INT wtWebioAn1GraphStTzStopMode | 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.13 | INTEGER | read-write | Mode of the week day on which the change is made from summer time to winter time. |
| INT wtWebioAn1GraphStTzStopWday | 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.14 | INTEGER | read-write | Day of the week on which the change is made from summer time to winter time. |
| INT wtWebioAn1GraphStTzStopHrs | 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.15 | INTEGER | read-write | Hour at which the time zone is changed from summer to winter time with respect to UTC. |
| INT wtWebioAn1GraphStTzStopMin | 1.3.6.1.4.1.5040.1.2.8.3.1.2.1.16 | INTEGER | read-write | Minute at which the time zone is changed from summer to winter time with respect to UTC. |
| wtWebioAn1GraphTimeServer | 1.3.6.1.4.1.5040.1.2.8.3.1.2.2 | |||
| OCT wtWebioAn1GraphTimeServer1 | 1.3.6.1.4.1.5040.1.2.8.3.1.2.2.1 | OCTET STRING | read-write | IP address or name of the 1st time server in ASCII |
| OCT wtWebioAn1GraphTimeServer2 | 1.3.6.1.4.1.5040.1.2.8.3.1.2.2.2 | OCTET STRING | read-write | IP address or name of the 2nd time server in ASCII |
| OCT wtWebioAn1GraphTsEnable | 1.3.6.1.4.1.5040.1.2.8.3.1.2.2.3 | OCTET STRING | read-write | Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server |
| INT wtWebioAn1GraphTsSyncTime | 1.3.6.1.4.1.5040.1.2.8.3.1.2.2.4 | INTEGER | read-write | Daily synchronisation time with the time server (hour: 0-23). |
| wtWebioAn1GraphDeviceClock | 1.3.6.1.4.1.5040.1.2.8.3.1.2.3 | |||
| INT wtWebioAn1GraphClockHrs | 1.3.6.1.4.1.5040.1.2.8.3.1.2.3.1 | INTEGER | read-write | Clock hours taking into account the time zone settings. |
| INT wtWebioAn1GraphClockMin | 1.3.6.1.4.1.5040.1.2.8.3.1.2.3.2 | INTEGER | read-write | Clock minutes taking into account the time zone settings. |
| INT wtWebioAn1GraphClockDay | 1.3.6.1.4.1.5040.1.2.8.3.1.2.3.3 | INTEGER | read-write | Date: Day of the month, taking into account the time zone settings. |
| INT wtWebioAn1GraphClockMonth | 1.3.6.1.4.1.5040.1.2.8.3.1.2.3.4 | INTEGER | read-write | Date: Month, taking into account the time zone settings. |
| INT wtWebioAn1GraphClockYear | 1.3.6.1.4.1.5040.1.2.8.3.1.2.3.5 | INTEGER | read-write | Date: Year, taking into account the time zone settings. |
| wtWebioAn1GraphBasic | 1.3.6.1.4.1.5040.1.2.8.3.1.3 | |||
| wtWebioAn1GraphNetwork | 1.3.6.1.4.1.5040.1.2.8.3.1.3.1 | |||
| IP wtWebioAn1GraphIpAddress | 1.3.6.1.4.1.5040.1.2.8.3.1.3.1.1 | IpAddress | read-write | IP address of the Webio |
| IP wtWebioAn1GraphSubnetMask | 1.3.6.1.4.1.5040.1.2.8.3.1.3.1.2 | IpAddress | read-write | Subnet mask of the Webio |
| IP wtWebioAn1GraphGateway | 1.3.6.1.4.1.5040.1.2.8.3.1.3.1.3 | IpAddress | read-write | Gateway of the Webio |
| OCT wtWebioAn1GraphDnsServer1 | 1.3.6.1.4.1.5040.1.2.8.3.1.3.1.4 | OCTET STRING | read-write | IP address of the 1st DNS server in ASCII |
| OCT wtWebioAn1GraphDnsServer2 | 1.3.6.1.4.1.5040.1.2.8.3.1.3.1.5 | OCTET STRING | read-write | IP address of the 2nd DNS server in ASCII |
| OCT wtWebioAn1GraphAddConfig | 1.3.6.1.4.1.5040.1.2.8.3.1.3.1.6 | OCTET STRING | read-write | Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: BOOTP disable |
| wtWebioAn1GraphHTML | 1.3.6.1.4.1.5040.1.2.8.3.1.3.2 | |||
| wtWebioAn1GraphMail | 1.3.6.1.4.1.5040.1.2.8.3.1.3.3 | |||
| OCT wtWebioAn1GraphMailAdName | 1.3.6.1.4.1.5040.1.2.8.3.1.3.3.1 | OCTET STRING | read-write | Device name for mail administration. |
| OCT wtWebioAn1GraphMailReply | 1.3.6.1.4.1.5040.1.2.8.3.1.3.3.2 | OCTET STRING | read-write | Reply address for the mail server. |
| OCT wtWebioAn1GraphMailServer | 1.3.6.1.4.1.5040.1.2.8.3.1.3.3.3 | OCTET STRING | read-write | Name or IP address of the mail server. |
| OCT wtWebioAn1MailEnable | 1.3.6.1.4.1.5040.1.2.8.3.1.3.3.4 | OCTET STRING | read-write | Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable |
| OCT wtWebioAn1GraphMailAuthentication | 1.3.6.1.4.1.5040.1.2.8.3.1.3.3.5 | OCTET STRING | read-write | Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication |
| OCT wtWebioAn1GraphMailAuthUser | 1.3.6.1.4.1.5040.1.2.8.3.1.3.3.6 | OCTET STRING | read-write | Name of the user to be authenticated. |
| OCT wtWebioAn1GraphMailAuthPassword | 1.3.6.1.4.1.5040.1.2.8.3.1.3.3.7 | OCTET STRING | read-write | Authentication password. |
| OCT wtWebioAn1GraphMailPop3Server | 1.3.6.1.4.1.5040.1.2.8.3.1.3.3.8 | OCTET STRING | read-write | Name or Ip-address of the POP3 Servers. |
| wtWebioAn1GraphSNMP | 1.3.6.1.4.1.5040.1.2.8.3.1.3.4 | |||
| OCT wtWebioAn1GraphSnmpCommunityStringRead | 1.3.6.1.4.1.5040.1.2.8.3.1.3.4.1 | OCTET STRING | read-write | Community string read only |
| OCT wtWebioAn1GraphSnmpCommunityStringReadWrite | 1.3.6.1.4.1.5040.1.2.8.3.1.3.4.2 | OCTET STRING | read-write | Community string read / write |
| OCT wtWebioAn1GraphSystemTrapManagerIP | 1.3.6.1.4.1.5040.1.2.8.3.1.3.4.3 | OCTET STRING | read-write | Name or IP address of the TCP server which accepts the system trap. |
| OCT wtWebioAn1GraphSystemTrapEnable | 1.3.6.1.4.1.5040.1.2.8.3.1.3.4.4 | OCTET STRING | read-write | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused |
| OCT wtWebioAn1GraphSnmpEnable | 1.3.6.1.4.1.5040.1.2.8.3.1.3.4.5 | OCTET STRING | read-write | Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable |
| OCT wtWebioAn1GraphSnmpCommunityStringTrap | 1.3.6.1.4.1.5040.1.2.8.3.1.3.4.6 | OCTET STRING | read-write | Community string of the traps. |
| wtWebioAn1GraphUDP | 1.3.6.1.4.1.5040.1.2.8.3.1.3.5 | |||
| INT wtWebioAn1GraphUdpPort | 1.3.6.1.4.1.5040.1.2.8.3.1.3.5.1 | INTEGER | read-write | Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device. |
| OCT wtWebioAn1GraphUdpEnable | 1.3.6.1.4.1.5040.1.2.8.3.1.3.5.2 | OCTET STRING | read-write | Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable |
| wtWebioAn1GraphSyslog | 1.3.6.1.4.1.5040.1.2.8.3.1.3.6 | |||
| OCT wtWebioAn1GraphSyslogServerIP | 1.3.6.1.4.1.5040.1.2.8.3.1.3.6.1 | OCTET STRING | read-write | Name or IP address of the Syslog server, which accepts the Syslog messgaes. |
| INT wtWebioAn1GraphSyslogServerPort | 1.3.6.1.4.1.5040.1.2.8.3.1.3.6.2 | INTEGER | read-write | Portnumber of the Syslog servers, default 514. |
| OCT wtWebioAn1GraphSyslogSystemMessagesEnable | 1.3.6.1.4.1.5040.1.2.8.3.1.3.6.3 | OCTET STRING | read-write | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused |
| OCT wtWebioAn1GraphSyslogEnable | 1.3.6.1.4.1.5040.1.2.8.3.1.3.6.4 | OCTET STRING | read-write | Set bit 0 to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable |
| wtWebioAn1GraphFTP | 1.3.6.1.4.1.5040.1.2.8.3.1.3.7 | |||
| OCT wtWebioAn1GraphFTPServerIP | 1.3.6.1.4.1.5040.1.2.8.3.1.3.7.1 | OCTET STRING | read-write | Name or IP address of the FTP server, which accepts the FTP messages. |
| INT wtWebioAn1GraphFTPServerControlPort | 1.3.6.1.4.1.5040.1.2.8.3.1.3.7.2 | INTEGER | read-write | Portnumber of the control port of the FTP server, default 21. |
| OCT wtWebioAn1GraphFTPUserName | 1.3.6.1.4.1.5040.1.2.8.3.1.3.7.3 | OCTET STRING | read-write | FTP Loggin: user name. |
| OCT wtWebioAn1GraphFTPPassword | 1.3.6.1.4.1.5040.1.2.8.3.1.3.7.4 | OCTET STRING | read-write | FTP Loggin: user password. |
| OCT wtWebioAn1GraphFTPAccount | 1.3.6.1.4.1.5040.1.2.8.3.1.3.7.5 | OCTET STRING | read-write | FTP Loggin: name of account. |
| OCT wtWebioAn1GraphFTPOption | 1.3.6.1.4.1.5040.1.2.8.3.1.3.7.6 | OCTET STRING | read-write | Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable |
| OCT wtWebioAn1GraphFTPEnable | 1.3.6.1.4.1.5040.1.2.8.3.1.3.7.7 | OCTET STRING | read-write | Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable |
| wtWebioAn1GraphHTTP | 1.3.6.1.4.1.5040.1.2.8.3.1.3.8 | |||
| OCT wtWebioAn1GraphStartup | 1.3.6.1.4.1.5040.1.2.8.3.1.3.8.1 | OCTET STRING | read-write | Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selected at a time. |
| OCT wtWebioAn1GraphGetHeaderEnable | 1.3.6.1.4.1.5040.1.2.8.3.1.3.8.2 | OCTET STRING | read-write | If this bit is set, every answer of a short form GET question will be lead by the IP-address and name of the device: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : GET Header enable |
| INT wtWebioAn1GraphHttpPort | 1.3.6.1.4.1.5040.1.2.8.3.1.3.8.3 | INTEGER | read-write | Definition of the standard HTML port (Default: 80). |
| wtWebioAn1GraphDatalogger | 1.3.6.1.4.1.5040.1.2.8.3.1.4 | |||
| INT wtWebioAn1GraphLoggerTimebase | 1.3.6.1.4.1.5040.1.2.8.3.1.4.1 | INTEGER | read-write | Time base of the data logger |
| OCT wtWebioAn1GraphLoggerSensorSel | 1.3.6.1.4.1.5040.1.2.8.3.1.4.2 | OCTET STRING | read-write | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8 |
| OCT wtWebioAn1GraphDisplaySensorSel | 1.3.6.1.4.1.5040.1.2.8.3.1.4.3 | OCTET STRING | read-write | Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8 |
| wtWebioAn1GraphSensorColorTable | 1.3.6.1.4.1.5040.1.2.8.3.1.4.4 | not-accessible | List of sensor colors for the praphical presentation. | |
| wtWebioAn1GraphSensorColorEntry | 1.3.6.1.4.1.5040.1.2.8.3.1.4.4.1 | not-accessible | Index numbers of the sensors. | |
| OCT wtWebioAn1GraphSensorColor | 1.3.6.1.4.1.5040.1.2.8.3.1.4.4.1.1 | OCTET STRING | read-write | Color of the sensors at the praphical presention. |
| OCT wtWebioAn1GraphAutoScaleEnable | 1.3.6.1.4.1.5040.1.2.8.3.1.4.5 | OCTET STRING | read-write | If bit 0 is set, vertical auto scale is enabled: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Auto Scale enable |
| OCT wtWebioAn1GraphVerticalUpperLimit | 1.3.6.1.4.1.5040.1.2.8.3.1.4.6 | OCTET STRING | read-write | This value defines the maximum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places. |
| OCT wtWebioAn1GraphVerticalLowerLimit | 1.3.6.1.4.1.5040.1.2.8.3.1.4.7 | OCTET STRING | read-write | This value defines the minimum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places. |
| INT wtWebioAn1GraphHorizontalZoom | 1.3.6.1.4.1.5040.1.2.8.3.1.4.8 | INTEGER | read-write | Defines the default zoom stage, if no auto scaling is selected. |
| wtWebioAn1GraphAlarm | 1.3.6.1.4.1.5040.1.2.8.3.1.5 | |||
| INT wtWebioAn1GraphAlarmCount | 1.3.6.1.4.1.5040.1.2.8.3.1.5.1 | INTEGER | read-only | Number of independent alarms. |
| wtWebioAn1GraphAlarmIfTable | 1.3.6.1.4.1.5040.1.2.8.3.1.5.2 | not-accessible | List of alarm indices. | |
| wtWebioAn1GraphAlarmIfEntry | 1.3.6.1.4.1.5040.1.2.8.3.1.5.2.1 | not-accessible | Numbers of the alarms. | |
| INT wtWebioAn1GraphAlarmNo | 1.3.6.1.4.1.5040.1.2.8.3.1.5.2.1.1 | INTEGER | read-only | Alarm number. |
| wtWebioAn1GraphAlarmTable | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3 | not-accessible | List of settings depending on the alarm number. | |
| wtWebioAn1GraphAlarmEntry | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1 | not-accessible | Alarm parameters of the individual alarms. | |
| OCT wtWebioAn1GraphAlarmTrigger | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.1 | OCTET STRING | read-write | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8 |
| OCT wtWebioAn1GraphAlarmMin | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.2 | OCTET STRING | read-write | Minimum temperature in degrees with maximum 2 decimal places. |
| OCT wtWebioAn1GraphAlarmMax | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.3 | OCTET STRING | read-write | Maximum temperature in degrees with maximum 2 decimal places. |
| OCT wtWebioAn1GraphAlarmHysteresis | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.4 | OCTET STRING | read-write | Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places. |
| OCT wtWebioAn1GraphAlarmDelay | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.5 | OCTET STRING | read-write | Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes). |
| OCT wtWebioAn1GraphAlarmInterval | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.6 | OCTET STRING | read-write | Send interval for alarm messages. |
| OCT wtWebioAn1GraphAlarmEnable | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.7 | OCTET STRING | read-write | Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable |
| OCT wtWebioAn1GraphAlarmEMailAddr | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.8 | OCTET STRING | read-write | E-Mail address for sending the alarm mail to. |
| OCT wtWebioAn1GraphAlarmMailSubject | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.9 | OCTET STRING | read-write | Subject line for alarm mail. |
| OCT wtWebioAn1GraphAlarmMailText | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.10 | OCTET STRING | read-write | Alarm mail text: provides the current temperature; n = 1..8. provides the current time. |
| OCT wtWebioAn1GraphAlarmManagerIP | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.11 | OCTET STRING | read-write | Name or IP address of the SNMP Manager which accepts the trap. |
| OCT wtWebioAn1GraphAlarmTrapText | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.12 | OCTET STRING | read-write | This text is sent in the trap body. |
| OCT wtWebioAn1GraphAlarmMailOptions | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.13 | OCTET STRING | read-write | Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1-7: unused |
| OCT wtWebioAn1GraphAlarmTcpIpAddr | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.14 | OCTET STRING | read-write | Name or IP address of the TCP server which accepts the trap. |
| INT wtWebioAn1GraphAlarmTcpPort | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.15 | INTEGER | read-write | Port number of the TCP server which accepts the trap. |
| OCT wtWebioAn1GraphAlarmTcpText | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.16 | OCTET STRING | read-write | This text is sent in the TCP trap body. |
| OCT wtWebioAn1GraphAlarmClearMailSubject | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.17 | OCTET STRING | read-write | Subject line for alarm clear mail. |
| OCT wtWebioAn1GraphAlarmClearMailText | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.18 | OCTET STRING | read-write | Alarm clear mail text: provides the current temperature; n = 1..8. provides the current time. |
| OCT wtWebioAn1GraphAlarmClearTrapText | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.19 | OCTET STRING | read-write | This text is sent in the trap body. |
| OCT wtWebioAn1GraphAlarmClearTcpText | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.20 | OCTET STRING | read-write | This text is sent in the TCP trap body. |
| IP wtWebioAn1GraphAlarmSyslogIpAddr | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.21 | IpAddress | read-write | IP address of the syslog server to which the Webio device should send syslog messages. |
| INT wtWebioAn1GraphAlarmSyslogPort | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.22 | INTEGER | read-write | Port number of the syslog server to which the Webio device should send syslog messages. |
| OCT wtWebioAn1GraphAlarmSyslogText | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.23 | OCTET STRING | read-write | Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body. |
| OCT wtWebioAn1GraphAlarmSyslogClearText | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.24 | OCTET STRING | read-write | Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body. |
| OCT wtWebioAn1GraphAlarmFtpDataPort | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.25 | OCTET STRING | read-write | Local data port: 1..65535 or AUTO: the next free port will be assigned. |
| OCT wtWebioAn1GraphAlarmFtpFileName | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.26 | OCTET STRING | read-write | Name of the file including path informations. |
| OCT wtWebioAn1GraphAlarmFtpText | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.27 | OCTET STRING | read-write | Message text to store on the FTP server. |
| OCT wtWebioAn1GraphAlarmFtpClearText | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.28 | OCTET STRING | read-write | Alarm clear message to store on the FTP server. |
| OCT wtWebioAn1GraphAlarmFtpOptions | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.29 | OCTET STRING | read-write | Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused |
| OCT wtWebioAn1GraphAlarmTimerCron | 1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.30 | OCTET STRING | read-write | This entry contains 5 text fields space or tab seperated for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separately. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute). |
| wtWebioAn1GraphPorts | 1.3.6.1.4.1.5040.1.2.8.3.2 | |||
| wtWebioAn1GraphPortTable | 1.3.6.1.4.1.5040.1.2.8.3.2.1 | not-accessible | List of settings depending on the sensor number. | |
| wtWebioAn1GraphPortEntry | 1.3.6.1.4.1.5040.1.2.8.3.2.1.1 | not-accessible | Sensor parameters for the individual sensors. | |
| OCT wtWebioAn1GraphPortName | 1.3.6.1.4.1.5040.1.2.8.3.2.1.1.1 | OCTET STRING | read-write | Name of the sensor. |
| OCT wtWebioAn1GraphPortText | 1.3.6.1.4.1.5040.1.2.8.3.2.1.1.2 | OCTET STRING | read-write | Description of the sensor. |
| OCT wtWebioAn1GraphPortOffset1 | 1.3.6.1.4.1.5040.1.2.8.3.2.1.1.3 | OCTET STRING | read-write | Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1. |
| OCT wtWebioAn1GraphPortTemperature1 | 1.3.6.1.4.1.5040.1.2.8.3.2.1.1.4 | OCTET STRING | read-write | Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places. |
| OCT wtWebioAn1GraphPortOffset2 | 1.3.6.1.4.1.5040.1.2.8.3.2.1.1.5 | OCTET STRING | read-write | Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2. |
| OCT wtWebioAn1GraphPortTemperature2 | 1.3.6.1.4.1.5040.1.2.8.3.2.1.1.6 | OCTET STRING | read-write | Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places. |
| OCT wtWebioAn1GraphPortComment | 1.3.6.1.4.1.5040.1.2.8.3.2.1.1.7 | OCTET STRING | read-write | Offset calibration: informations of date, name of operator, reference devices. |
| wtWebioAn1GraphManufact | 1.3.6.1.4.1.5040.1.2.8.3.3 | |||
| OCT wtWebioAn1GraphMfName | 1.3.6.1.4.1.5040.1.2.8.3.3.1 | OCTET STRING | read-write | Manufacturer company name |
| OCT wtWebioAn1GraphMfAddr | 1.3.6.1.4.1.5040.1.2.8.3.3.2 | OCTET STRING | read-write | Manufacturer address. |
| OCT wtWebioAn1GraphMfHotline | 1.3.6.1.4.1.5040.1.2.8.3.3.3 | OCTET STRING | read-write | Manufacturer hotline. |
| OCT wtWebioAn1GraphMfInternet | 1.3.6.1.4.1.5040.1.2.8.3.3.4 | OCTET STRING | read-write | Manufacturer Internet address. |
| OCT wtWebioAn1GraphMfDeviceTyp | 1.3.6.1.4.1.5040.1.2.8.3.3.5 | OCTET STRING | read-write | Manufacturer device name (model number). |
| OCT wtWebioAn1GraphMfOrderNo | 1.3.6.1.4.1.5040.1.2.8.3.3.6 | OCTET STRING | read-write | Manufacturer part number. |
| wtWebioAn1GraphDiag | 1.3.6.1.4.1.5040.1.2.8.3.4 | |||
| INT wtWebioAn1GraphDiagErrorCount | 1.3.6.1.4.1.5040.1.2.8.3.4.1 | INTEGER | read-only | Number of entries in the error memory. |
| OCT wtWebioAn1GraphDiagBinaryError | 1.3.6.1.4.1.5040.1.2.8.3.4.2 | OCTET STRING | read-only | Error causes coded bit-by-bit. |
| INT wtWebioAn1GraphDiagErrorIndex | 1.3.6.1.4.1.5040.1.2.8.3.4.3 | INTEGER | read-write | The value of this variable is used as an index to read an error massege from wtWebioAn1GraphDiagErrorMessage. Errors are numbered from 1 to wtWebioAn1GraphDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioAn1GraphDiagErrorMessage. |
| OCT wtWebioAn1GraphDiagErrorMessage | 1.3.6.1.4.1.5040.1.2.8.3.4.4 | OCTET STRING | read-only | Using wtWebioAn1GraphDiagErrorIndex as an index, the appropriate message is available. |
| INT wtWebioAn1GraphDiagErrorClear | 1.3.6.1.4.1.5040.1.2.8.3.4.5 | INTEGER | write-only | Writing 1 into this variable clears all diagnosis messages. |
RFC description
Manages WebGraph Thermometer remote monitoring devices with digital input/output, alarms, and syslog configuration.
Start monitoring WebGraph/Webio networked thermometer sensor appliance (temperature reading/threshold-alarm status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.