WebGraph-Thermometer-US-MIB :: wtWebioAn1GraphSessCntrlAdminPassword

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › WebGraph-Thermometer-US-MIB › wtWebioAn1GraphSessCntrlAdminPassword

wtWebioAn1GraphSessCntrlAdminPassword

Module: WebGraph-Thermometer-US-MIB

OID (symbolic): WebGraph-Thermometer-US-MIB::wtWebioAn1GraphSessCntrlAdminPassword

OID (numeric): 1.3.6.1.4.1.5040.1.2.8.2.4

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.

What is wtWebioAn1GraphSessCntrlAdminPassword?

Sets the administrator password protecting variables with admin-level rights; only the administrator can change it, and the source DESCRIPTION notes the factory default password is "public" if none has been set.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.8.2.4
snmpwalk -v2c -c public <target> WebGraph-Thermometer-US-MIB::wtWebioAn1GraphSessCntrlAdminPassword

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5040.1.2.8.2.4.1
snmpget -v2c -c public <target> WebGraph-Thermometer-US-MIB::wtWebioAn1GraphSessCntrlAdminPassword.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5040.1.2.8.2.4.1 s <value>

Start monitoring WebGraph/Webio networked thermometer sensor appliance (temperature reading/threshold-alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WebGraph-Thermometer-US-MIB::wtWebioAn1GraphSessCntrlAdminPassword OID value, configure state conditions and alerts, and monitor any WebGraph/Webio networked thermometer sensor appliance (temperature reading/threshold-alarm status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5040wutCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1wtComServerCom-Server-Intern-MIB
1.3.6.1.4.1.5040.1.2wtWebioWebGraph-8xThermometer-US-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5040.1.2.8wtWebioAn1GraphWebGraph-Thermometer-US-MIB
1.3.6.1.4.1.5040.1.2.8.2wtWebioAn1GraphSessCntrlWebGraph-Thermometer-US-MIB
1.3.6.1.4.1.5040.1.2.8.2.4wtWebioAn1GraphSessCntrlAdminPasswordWebGraph-Thermometer-US-MIB