All MIBs › WHISP-PLV-GATEWAY-MIB
Organization: Motorola
Last Updated: 2006-07-28
Category: Cambium/Motorola Wireless Broadband
Description: Manages Motorola Canopy Point-to-Multipoint gateway device configuration, bridging, and network connectivity status.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is WHISP-PLV-GATEWAY-MIB?
WHISP-PLV-GATEWAY-MIB is a Motorola (Canopy/WHISP broadband wireless heritage) proprietary MIB for the PLV (Power Line/Voltage?) Gateway device, reporting identity and configuration. Its objects cover model, serial number, LAN/WAN/PLC MAC addresses, hardware version, device/loader/SIM firmware versions, modem count, device/SIM upgrade status, temperature, NTP config/server, current time/date, modem-table timeout, auto-logout time, a PSD setting, and up to three trap-destination IP/community-string pairs. As a configuration/status MIB it lets an administrator confirm firmware versions and trap-destination configuration on a Motorola WHISP PLV Gateway. It is deployed on Motorola WHISP PLV Gateway devices. Engineers can download the WHISP-PLV-GATEWAY-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in WHISP-PLV-GATEWAY-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Motorola WHISP PLV Gateway devices
Monitoring Examples
An administrator checks gwInfoDevFirmwareVer and gwConfTrapIp1 to confirm firmware version and trap-destination configuration on a Motorola WHISP PLV Gateway.
What Can Be Monitored
- gateway firmware version and trap-destination configuration
This MIB depends on
Related MIBs
Imported Objects
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Counter32 | |
| Gauge32 | |
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE |
From SNMPv2-TC
| DisplayString | |
| MacAddress |
From WHISP-GLOBAL-REG-MIB
| whispPlvGateway | OBJECT-IDENTITY |
From WHISP-TC-MIB
| WhispLUID | |
| WhispMACAddress |
How to Use in IPNetwork Monitor
Example using gwModemInOctets OID:
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| whispPlvGatewayMIB | 1.3.6.1.4.1.161.19.3.8.1 | Initial Version. | ||
| whispPlvGatewayObjects | 1.3.6.1.4.1.161.19.3.8.1.1 | |||
| whispPlvGwInfo | 1.3.6.1.4.1.161.19.3.8.1.1.1 | |||
| STR gwInfoModel | 1.3.6.1.4.1.161.19.3.8.1.1.1.1 | DisplayString | read-only | This object indicates the Gateway Model Number. |
| STR gwInfoSerialNumber | 1.3.6.1.4.1.161.19.3.8.1.1.1.2 | DisplayString | read-only | This object indicates the Gateway Serial Number. |
| MAC gwInfoLanMac | 1.3.6.1.4.1.161.19.3.8.1.1.1.3 | MacAddress | read-only | This object indicates the Gateway's LAN port MAC Address. |
| MAC gwInfoWanMac | 1.3.6.1.4.1.161.19.3.8.1.1.1.4 | MacAddress | read-only | This object indicates the Gateway's WAN port MAC Address. |
| MAC gwInfoPlcMac | 1.3.6.1.4.1.161.19.3.8.1.1.1.5 | MacAddress | read-only | This object indicates the Gateway PLC MAC Address |
| STR gwInfoHardwareVer | 1.3.6.1.4.1.161.19.3.8.1.1.1.6 | DisplayString | read-only | This object indicates the Gateway Hardware Version. |
| STR gwInfoDevFirmwareVer | 1.3.6.1.4.1.161.19.3.8.1.1.1.7 | DisplayString | read-only | This object indicates the Gateway Device Firmware Version. |
| STR gwInfoLoaderVer | 1.3.6.1.4.1.161.19.3.8.1.1.1.8 | DisplayString | read-only | This object indicates the Gateway Loader Version. |
| STR gwInfoSimFirmwareVer | 1.3.6.1.4.1.161.19.3.8.1.1.1.9 | DisplayString | read-only | This object indicates the Intellon Simple Module Firmware Version. |
| I32 gwInfoModemCount | 1.3.6.1.4.1.161.19.3.8.1.1.1.10 | Integer32 | read-only | This object indicates the number of Modems registered to the Gateway. |
| INT gwInfoDeviceUpgradeStatus | 1.3.6.1.4.1.161.19.3.8.1.1.1.11 | INTEGER | read-only | This object indicates the Gateway Last Software Upgrade Status. 0 - Upgrade not started 1 - Upgrade in progress 2 - Last Upgrade failed 3 - Last Upgrade was successful. |
| INT gwInfoSimUpgradeStatus | 1.3.6.1.4.1.161.19.3.8.1.1.1.12 | INTEGER | read-only | This object indicates the Intellon Simple Module's last Software Upgrade Status. 0 - Upgrade not started 1 - Upgrade in progress 2 - Last Upgrade failed 3 - Last Upgrade was successful. |
| I32 gwInfoTemperature | 1.3.6.1.4.1.161.19.3.8.1.1.1.13 | Integer32 | read-only | This object indicates the ambient temperature of the Gateway. |
| whispPlvGwConfig | 1.3.6.1.4.1.161.19.3.8.1.1.2 | |||
| INT gwConfNtpConfig | 1.3.6.1.4.1.161.19.3.8.1.1.2.1 | INTEGER | read-write | This object is used to Enable or Disable the Gateway to set it's system clock using NTP. |
| STR gwConfNtpServer | 1.3.6.1.4.1.161.19.3.8.1.1.2.2 | DisplayString | read-write | This object is used to configure the NTP Server. |
| STR gwConfTime | 1.3.6.1.4.1.161.19.3.8.1.1.2.3 | DisplayString | read-write | This object is used to configure Gateway's system clock time. The input format is HH:MM::SS. This object is accessible only if gwConfNtpConfig is disabled. |
| STR gwConfDate | 1.3.6.1.4.1.161.19.3.8.1.1.2.4 | DisplayString | read-write | This object is used to configure Gateway's system clock date. The input format is YYYY/MM/DD. This object is accessible only if gwConfNtpConfig is disabled. |
| I32 gwConfModemTableTimeout | 1.3.6.1.4.1.161.19.3.8.1.1.2.5 | Integer32 | read-write | This object is used to configure the Modem Table Timeout. Any Inactive Modem will be deleted from the Modem table, if it is inactive for a period more than the timeout value. |
| I32 gwConfAutoLogoutTime | 1.3.6.1.4.1.161.19.3.8.1.1.2.6 | Integer32 | read-write | This object is used to configure the Gateway Auto Logout Time. User will be logged out of the Gateway's web interface, if there is inactivity for a period more than the Auto Logout Time. |
| OCT gwConfPSD | 1.3.6.1.4.1.161.19.3.8.1.1.2.7 | OCTET STRING | read-write | This object indicates the Power Spectral Density of the signal, at all the 84 carriers, that the device transmits. Starting at the left most octet, which represents the spectral value at channel number 0, each octet represents the spectral value at the corresponding channel number. The channel numbers 4, 5, 13, 14, 29, 49, 50, 51, 69 and 70 are masked and their spectral values cannot be changed. |
| whispPlvGwTrapConfig | 1.3.6.1.4.1.161.19.3.8.1.1.3 | |||
| IP gwConfTrapIp1 | 1.3.6.1.4.1.161.19.3.8.1.1.3.1 | IpAddress | read-write | This object is used to configure IP Address of SNMP Trap Client #1. |
| STR gwConfTrapCommStr1 | 1.3.6.1.4.1.161.19.3.8.1.1.3.2 | DisplayString | read-write | This object is used to configure SNMP Community string for Trap Client #1. |
| IP gwConfTrapIp2 | 1.3.6.1.4.1.161.19.3.8.1.1.3.3 | IpAddress | read-write | This object is used to configure IP Address of SNMP Trap Client #2. |
| STR gwConfTrapCommStr2 | 1.3.6.1.4.1.161.19.3.8.1.1.3.4 | DisplayString | read-write | This object is used to configure SNMP Community string for Trap Client #2. |
| IP gwConfTrapIp3 | 1.3.6.1.4.1.161.19.3.8.1.1.3.5 | IpAddress | read-write | This object is used to configure IP Address of SNMP Trap Client #3. |
| STR gwConfTrapCommStr3 | 1.3.6.1.4.1.161.19.3.8.1.1.3.6 | DisplayString | read-write | This object is used to configure SNMP Community string for Trap Client #3. |
| IP gwConfTrapIp4 | 1.3.6.1.4.1.161.19.3.8.1.1.3.7 | IpAddress | read-write | This object is used to configure IP Address of SNMP Trap Client #4. |
| STR gwConfTrapCommStr4 | 1.3.6.1.4.1.161.19.3.8.1.1.3.8 | DisplayString | read-write | This object is used to configure SNMP Community string for Trap Client #4. |
| IP gwConfTrapIp5 | 1.3.6.1.4.1.161.19.3.8.1.1.3.9 | IpAddress | read-write | This object is used to configure IP Address of SNMP Trap Client #5. |
| STR gwConfTrapCommStr5 | 1.3.6.1.4.1.161.19.3.8.1.1.3.10 | DisplayString | read-write | This object is used to configure SNMP Community string for Trap Client #5. |
| IP gwConfTrapIp6 | 1.3.6.1.4.1.161.19.3.8.1.1.3.11 | IpAddress | read-write | This object is used to configure IP Address of SNMP Trap Client #6. |
| STR gwConfTrapCommStr6 | 1.3.6.1.4.1.161.19.3.8.1.1.3.12 | DisplayString | read-write | This object is used to configure SNMP Community string for Trap Client #6. |
| IP gwConfTrapIp7 | 1.3.6.1.4.1.161.19.3.8.1.1.3.13 | IpAddress | read-write | This object is used to configure IP Address of SNMP Trap Client #7. |
| STR gwConfTrapCommStr7 | 1.3.6.1.4.1.161.19.3.8.1.1.3.14 | DisplayString | read-write | This object is used to configure SNMP Community string for Trap Client #7. |
| IP gwConfTrapIp8 | 1.3.6.1.4.1.161.19.3.8.1.1.3.15 | IpAddress | read-write | This object is used to configure IP Address of SNMP Trap Client #8. |
| STR gwConfTrapCommStr8 | 1.3.6.1.4.1.161.19.3.8.1.1.3.16 | DisplayString | read-write | This object is used to configure SNMP Community string for Trap Client #8. |
| IP gwConfTrapIp9 | 1.3.6.1.4.1.161.19.3.8.1.1.3.17 | IpAddress | read-write | This object is used to configure IP Address of SNMP Trap Client #9. |
| STR gwConfTrapCommStr9 | 1.3.6.1.4.1.161.19.3.8.1.1.3.18 | DisplayString | read-write | This object is used to configure SNMP Community string for Trap Client #9. |
| IP gwConfTrapIp10 | 1.3.6.1.4.1.161.19.3.8.1.1.3.19 | IpAddress | read-write | This object is used to configure IP Address of SNMP Trap Client #10. |
| STR gwConfTrapCommStr10 | 1.3.6.1.4.1.161.19.3.8.1.1.3.20 | DisplayString | read-write | This object is used to configure SNMP Community string for Trap Client #10. |
| whispPlvGwPwrLnStats | 1.3.6.1.4.1.161.19.3.8.1.1.4 | |||
| I32 gwPwrLnMaxDelay | 1.3.6.1.4.1.161.19.3.8.1.1.4.1 | Integer32 | read-only | This object indicates the Maximum transfer delay on Powerline. |
| I32 gwPwrLnTxAck | 1.3.6.1.4.1.161.19.3.8.1.1.4.2 | Integer32 | read-only | This object indicates the Powerline Transmit ACK count. |
| I32 gwPwrLnTxNak | 1.3.6.1.4.1.161.19.3.8.1.1.4.3 | Integer32 | read-only | This object indicates the Powerline Transmit NACK count. |
| I32 gwPwrLnTxFail | 1.3.6.1.4.1.161.19.3.8.1.1.4.4 | Integer32 | read-only | This object indicates the Powerline Transmission Failures. |
| I32 gwPwrLnTxColl | 1.3.6.1.4.1.161.19.3.8.1.1.4.5 | Integer32 | read-only | This object indicates the Powerline Transmission Collisions. |
| I32 gwPwrLnTxCarrLoss | 1.3.6.1.4.1.161.19.3.8.1.1.4.6 | Integer32 | read-only | This object indicates the Powerline Transmt Carrier Loss Detection. |
| I32 gwPwrLnRoboByte40 | 1.3.6.1.4.1.161.19.3.8.1.1.4.7 | Integer32 | read-only | This object indicates the raw value of channel capacity as reported by Intellon PHY |
| I32 gwPwrLnRoboFails | 1.3.6.1.4.1.161.19.3.8.1.1.4.8 | Integer32 | read-only | This object indicates the Powerline protocol receive failures, in ROBO mode. |
| I32 gwPwrLnRoboDrops | 1.3.6.1.4.1.161.19.3.8.1.1.4.9 | Integer32 | read-only | This object indicates the Powerline protocol transmit drops, in ROBO mode. |
| whispPlvGwAdmConfig | 1.3.6.1.4.1.161.19.3.8.1.1.5 | |||
| STR gwAdmConfLoginUsername | 1.3.6.1.4.1.161.19.3.8.1.1.5.1 | DisplayString | read-write | This object is used to configure Gateway's System Management Login Username. |
| STR gwAdmConfLoginPassword | 1.3.6.1.4.1.161.19.3.8.1.1.5.2 | DisplayString | read-write | This object is used to configure Gateway's System Management Login Password. |
| STR gwAdmConfNEK | 1.3.6.1.4.1.161.19.3.8.1.1.5.3 | DisplayString | read-write | This object is used to configure Network Encryption Key of the Gateway. |
| IP gwAdmConfAuthServIp1 | 1.3.6.1.4.1.161.19.3.8.1.1.5.4 | IpAddress | read-write | This object is used to configure BAM Server #1 IP Address. |
| IP gwAdmConfAuthServIp2 | 1.3.6.1.4.1.161.19.3.8.1.1.5.5 | IpAddress | read-write | This object is used to configure BAM Server #2 IP Address. |
| IP gwAdmConfAuthServIp3 | 1.3.6.1.4.1.161.19.3.8.1.1.5.6 | IpAddress | read-write | This object is used to configure BAM Server #3 IP Address. |
| INT gwAdmConfAuthMode | 1.3.6.1.4.1.161.19.3.8.1.1.5.7 | INTEGER | read-write | This object is used to Enable or Disable BAM Authentication on the Gateway. |
| STR gwAdmConfAuthKey | 1.3.6.1.4.1.161.19.3.8.1.1.5.8 | DisplayString | read-write | This object is used to configure Authentication Key, to use with BAM Server, on the Gateway. |
| INT gwAdmConfAuthKeyOption | 1.3.6.1.4.1.161.19.3.8.1.1.5.9 | INTEGER | read-write | This object is used to configure the Authentication Key to be used, on the Gateway. |
| STR gwAdmConfSnmpGetCommStr | 1.3.6.1.4.1.161.19.3.8.1.1.5.10 | DisplayString | read-write | This object is used to configure SNMP 'Read' community string of the Gateway. |
| STR gwAdmConfSnmpSetCommStr | 1.3.6.1.4.1.161.19.3.8.1.1.5.11 | DisplayString | read-write | This object is used to configure SNMP 'Read-Write' community string of the Gateway. |
| STR gwAdmConfSnmpAdminCommStr | 1.3.6.1.4.1.161.19.3.8.1.1.5.12 | DisplayString | read-write | This object is used to configure SNMP 'Admin' community string of the Gateway. |
| IP gwAdmConfFtpServerIp | 1.3.6.1.4.1.161.19.3.8.1.1.5.13 | IpAddress | read-write | This object is used to configure IP Address of FTP server hosting auto-upgrade files. |
| STR gwAdmConfFtpUsername | 1.3.6.1.4.1.161.19.3.8.1.1.5.14 | DisplayString | read-write | This object is used to configure Username to login to a FTP server, for use with FTP-based auto-upgrade. |
| STR gwAdmConfFtpPassword | 1.3.6.1.4.1.161.19.3.8.1.1.5.15 | DisplayString | read-write | This object is used to configure Password to login to a FTP server, for use with FTP-based auto-upgrade. |
| STR gwAdmConfFtpFile | 1.3.6.1.4.1.161.19.3.8.1.1.5.16 | DisplayString | read-write | This object is used to configure Path and/or Filename of the firmware file, for use with FTP-based auto-upgrade. |
| INT gwAdmConfDeviceUpgradeStart | 1.3.6.1.4.1.161.19.3.8.1.1.5.17 | INTEGER | read-write | This object is used to Start Device Firmware Upgrade process in the Gateway. To start the upgrade process, this object should be set to '1'. |
| INT gwAdmConfSimUpgradeStart | 1.3.6.1.4.1.161.19.3.8.1.1.5.18 | INTEGER | read-write | This object is used to start Intellon Simple Module Firmware Upgrade process in the Gateway. To start the upgrade process, this object should be set to '1'. |
| INT gwAdmConfSystemReboot | 1.3.6.1.4.1.161.19.3.8.1.1.5.19 | INTEGER | read-write | This object is used to Reboot the Gateway. To reboot the Gateway, this object should be set to '1'. |
| INT gwAdmConfReset | 1.3.6.1.4.1.161.19.3.8.1.1.5.20 | INTEGER | read-write | This object is used to reset the Gateway configuration to Factory Defaults. To reset the Gateway configuration to factory defaults, this object should be set to '1'. |
| INT gwAdmConfDeviceMode | 1.3.6.1.4.1.161.19.3.8.1.1.5.21 | INTEGER | read-write | This object is used to configure the device in 'switch' mode or 'NAT' mode. |
| I32 gwAdmConfLUIDStart | 1.3.6.1.4.1.161.19.3.8.1.1.5.22 | Integer32 | read-write | This object is used to configure the starting value of the Modem LUID range. This value should not be greater than gwAdmConfLUIDEnd value |
| I32 gwAdmConfLUIDEnd | 1.3.6.1.4.1.161.19.3.8.1.1.5.23 | Integer32 | read-write | This object is used to configure the ending value of the Modem LUID range. This value should not be less than gwAdmConfLUIDStart value |
| INT gwAdmConfVLANPassthroughStatus | 1.3.6.1.4.1.161.19.3.8.1.1.5.24 | INTEGER | read-write | This object is used to enable or disable VLAN Passthrough feature. |
| I32 gwAdmConfManagementVLANId | 1.3.6.1.4.1.161.19.3.8.1.1.5.25 | Integer32 | read-write | This object is used to enable or disable VLAN Passthrough feature. |
| whispPlvGwAdmLanConfig | 1.3.6.1.4.1.161.19.3.8.1.1.6 | |||
| INT gwAdmConfLanConfig | 1.3.6.1.4.1.161.19.3.8.1.1.6.1 | INTEGER | read-write | This object is used to Enable or Disable DHCP client. |
| IP gwAdmConfLanIp | 1.3.6.1.4.1.161.19.3.8.1.1.6.2 | IpAddress | read-write | This object is used to configure LAN IP Address. |
| IP gwAdmConfLanSubnetMask | 1.3.6.1.4.1.161.19.3.8.1.1.6.3 | IpAddress | read-write | This object is used to configure LAN IP Subnet Mask. |
| IP gwAdmConfLanGatewayIp | 1.3.6.1.4.1.161.19.3.8.1.1.6.4 | IpAddress | read-write | This object is used to configure Gateway IP Address. |
| whispPlvGwAdmSnmpAcessConfig | 1.3.6.1.4.1.161.19.3.8.1.1.7 | |||
| IP gwAdmSnmpAccessIpNetwork1 | 1.3.6.1.4.1.161.19.3.8.1.1.7.1 | IpAddress | read-write | This object is used to configure SNMP Access Network Address #1. |
| IP gwAdmSnmpAccessIpNetworkMask1 | 1.3.6.1.4.1.161.19.3.8.1.1.7.2 | IpAddress | read-write | This object is used to configure SNMP Access Network Address Mask #1. |
| IP gwAdmSnmpAccessIpNetwork2 | 1.3.6.1.4.1.161.19.3.8.1.1.7.3 | IpAddress | read-write | This object is used to configure SNMP Access Network Address #2. |
| IP gwAdmSnmpAccessIpNetworkMask2 | 1.3.6.1.4.1.161.19.3.8.1.1.7.4 | IpAddress | read-write | This object is used to configure SNMP Access Network Address Mask #2. |
| IP gwAdmSnmpAccessIpNetwork3 | 1.3.6.1.4.1.161.19.3.8.1.1.7.5 | IpAddress | read-write | This object is used to configure SNMP Access Network Address #3. |
| IP gwAdmSnmpAccessIpNetworkMask3 | 1.3.6.1.4.1.161.19.3.8.1.1.7.6 | IpAddress | read-write | This object is used to configure SNMP Access Network Address Mask #3. |
| IP gwAdmSnmpAccessIpNetwork4 | 1.3.6.1.4.1.161.19.3.8.1.1.7.7 | IpAddress | read-write | This object is used to configure SNMP Access Network Address #4. |
| IP gwAdmSnmpAccessIpNetworkMask4 | 1.3.6.1.4.1.161.19.3.8.1.1.7.8 | IpAddress | read-write | This object is used to configure SNMP Access Network Address Mask #4. |
| IP gwAdmSnmpAccessIpNetwork5 | 1.3.6.1.4.1.161.19.3.8.1.1.7.9 | IpAddress | read-write | This object is used to configure SNMP Access Network Address #5. |
| IP gwAdmSnmpAccessIpNetworkMask5 | 1.3.6.1.4.1.161.19.3.8.1.1.7.10 | IpAddress | read-write | This object is used to configure SNMP Access Network Address Mask #5. |
| IP gwAdmSnmpAccessIpNetwork6 | 1.3.6.1.4.1.161.19.3.8.1.1.7.11 | IpAddress | read-write | This object is used to configure SNMP Access Network Address #6. |
| IP gwAdmSnmpAccessIpNetworkMask6 | 1.3.6.1.4.1.161.19.3.8.1.1.7.12 | IpAddress | read-write | This object is used to configure SNMP Access Network Address Mask #6. |
| IP gwAdmSnmpAccessIpNetwork7 | 1.3.6.1.4.1.161.19.3.8.1.1.7.13 | IpAddress | read-write | This object is used to configure SNMP Access Network Address #7. |
| IP gwAdmSnmpAccessIpNetworkMask7 | 1.3.6.1.4.1.161.19.3.8.1.1.7.14 | IpAddress | read-write | This object is used to configure SNMP Access Network Address Mask #7. |
| IP gwAdmSnmpAccessIpNetwork8 | 1.3.6.1.4.1.161.19.3.8.1.1.7.15 | IpAddress | read-write | This object is used to configure SNMP Access Network Address #8. |
| IP gwAdmSnmpAccessIpNetworkMask8 | 1.3.6.1.4.1.161.19.3.8.1.1.7.16 | IpAddress | read-write | This object is used to configure SNMP Access Network Address Mask #8. |
| IP gwAdmSnmpAccessIpNetwork9 | 1.3.6.1.4.1.161.19.3.8.1.1.7.17 | IpAddress | read-write | This object is used to configure SNMP Access Network Address #9. |
| IP gwAdmSnmpAccessIpNetworkMask9 | 1.3.6.1.4.1.161.19.3.8.1.1.7.18 | IpAddress | read-write | This object is used to configure SNMP Access Network Address Mask #9. |
| IP gwAdmSnmpAccessIpNetwork10 | 1.3.6.1.4.1.161.19.3.8.1.1.7.19 | IpAddress | read-write | This object is used to configure SNMP Access Network Address #10. |
| IP gwAdmSnmpAccessIpNetworkMask10 | 1.3.6.1.4.1.161.19.3.8.1.1.7.20 | IpAddress | read-write | This object is used to configure SNMP Access Network Address Mask #10. |
| whispPlvGwAdmWanConfig | 1.3.6.1.4.1.161.19.3.8.1.1.8 | |||
| INT gwAdmWConfWanConfig | 1.3.6.1.4.1.161.19.3.8.1.1.8.1 | INTEGER | read-write | This object is used to configure the WAN Type. This object is accessible only if the Gateway is in NAT mode. |
| IP gwAdmWConfWanIp | 1.3.6.1.4.1.161.19.3.8.1.1.8.2 | IpAddress | read-write | This object is used to configure WAN IP Address of the Gateway. This object is accessible only if the Gateway is in NAT mode. |
| IP gwAdmWConfSubnetMask | 1.3.6.1.4.1.161.19.3.8.1.1.8.3 | IpAddress | read-write | This object is used to configure WAN IP Subnet Mask of the Gateway. This object is accessible only if the Gateway is in NAT mode. |
| IP gwAdmWConfGateway | 1.3.6.1.4.1.161.19.3.8.1.1.8.4 | IpAddress | read-write | This object is used to configure Default Gateway IP of the Gateway. This object is accessible only if the Gateway is in NAT mode. |
| IP gwAdmWConfDNS1 | 1.3.6.1.4.1.161.19.3.8.1.1.8.5 | IpAddress | read-write | This object is used to configure DNS Server #1. This object is accessible only if the Gateway is in NAT mode. |
| IP gwAdmWConfDNS2 | 1.3.6.1.4.1.161.19.3.8.1.1.8.6 | IpAddress | read-write | This object is used to configure DNS Server #2. This object is accessible only if the Gateway is in NAT mode. |
| STR gwAdmWConfPppoeUsername | 1.3.6.1.4.1.161.19.3.8.1.1.8.7 | DisplayString | read-write | This object is used to configure PPPoE Username. This object is accessible only if the Gateway is in NAT mode. |
| STR gwAdmWConfPppoePassword | 1.3.6.1.4.1.161.19.3.8.1.1.8.8 | DisplayString | read-write | This object is used to configure PPPoE Password. This object is accessible only if the Gateway is in NAT mode. |
| INT gwAdmWConfDhcpConfig | 1.3.6.1.4.1.161.19.3.8.1.1.8.9 | INTEGER | read-write | This object is used to Enable or Disable DHCP Server. This object is accessible only if the Gateway is in NAT mode. |
| IP gwAdmWConfDhcpStartIp | 1.3.6.1.4.1.161.19.3.8.1.1.8.10 | IpAddress | read-write | This object is used to configure Starting Address of the IP address block, that the DHCP Server can assign to its clients. This object is accessible only if the Gateway is in NAT mode. |
| IP gwAdmWConfDhcpEndIp | 1.3.6.1.4.1.161.19.3.8.1.1.8.11 | IpAddress | read-write | This object is used to configure Last Address of the IP address block, that the DHCP Server can assign to its clients. This object is accessible only if the Gateway is in NAT mode. |
| INT gwAdmWConfDhcpLeaseTime | 1.3.6.1.4.1.161.19.3.8.1.1.8.12 | INTEGER | read-write | This object is used to configure time period for which the IP address assigned to a client is valid. This object is accessible only if the Gateway is in NAT mode. |
| INT gwAdmWConfUpnpConfig | 1.3.6.1.4.1.161.19.3.8.1.1.8.13 | INTEGER | read-write | This object is used to Enable or Disable the UPnP in the Gateway. This object is accessible only if the Gateway is in NAT mode. |
| INT gwAdmWConfFirewallConfig | 1.3.6.1.4.1.161.19.3.8.1.1.8.14 | INTEGER | read-write | This object is used to Enable or Disable Firewall in the Gateway. This object is accessible only if the Gateway is in NAT mode. |
| whispPlvGwModemTable | 1.3.6.1.4.1.161.19.3.8.1.1.9 | not-accessible | This table contains one row per Modem registered to the Gateway. | |
| whispPlvGwModemEntry | 1.3.6.1.4.1.161.19.3.8.1.1.9.1 | not-accessible | Information about a particular Modem registered to the Gateway. | |
| WHI gwModemLUID | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.1 | WhispLUID | read-only | This object indicates the unique value assigned by the Gateway, to each Modem. |
| STR gwModemDescr | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.2 | DisplayString | read-only | The value of this object should be same as the object 'sysName' of the Device registered to the Gateway. |
| ADR gwModemPhysAddress | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.3 | WhispMACAddress | read-only | This object indicates the PLC MAC Address of the Modem. |
| IP gwModemIP | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.4 | IpAddress | read-only | This object indicates the IP Address of the Modem. |
| STR gwModemHardwareVersion | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.5 | DisplayString | read-only | This object indicates the Hardware Version of the Modem. |
| STR gwModemSoftwareVersion | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.6 | DisplayString | read-only | This object indicates the Software Version of the Modem. |
| STR gwModemSoftwareBootVersion | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.7 | DisplayString | read-only | This object indicates the Boot Loader Version of the Modem. |
| INT gwModemSessState | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.8 | INTEGER | read-only | This object indicates the current Operational state of the Modem. 0 = Idle 1 = In Session 2 = Clearing 3 = Re-registration downlink reset 4 = Authentication Challenge 5 = Registering 6 = Not in use. |
| I32 gwModemsessionCount | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.9 | Integer32 | read-only | This object indicates the number of times the Modem is In and Out of session. |
| I32 gwModemMtu | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.10 | Integer32 | read-only | This object indicates the size of the largest datagram that can be sent and received by the Modem, in octets. |
| G32 gwModemSpeed | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.11 | Gauge32 | read-only | This object indicates an estimate of Modem's current bandwidth, in Mbps. |
| C32 gwModemInOctetsEx | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.12 | Counter32 | read-only | This object indicates the octets received by the Modem over Powerline, including framing characters. to each Modem. |
| C32 gwModemInUcastPkts | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.13 | Counter32 | read-only | This object indicates the number of subnetwork-unicast packets delivered to a higher-layer protocol. |
| C32 gwModemInNUcastPkts | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.14 | Counter32 | read-only | This object indicates the number of subnetwork-broadcast and subnetwork-multiicast packets delivered to a higher-layer protocol. |
| C32 gwModemInDiscards | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.15 | Counter32 | read-only | This object indicates the number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. |
| C32 gwModemInError | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.16 | Counter32 | read-only | This object indicates the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. |
| C32 gwModemInUnknownProtos | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.17 | Counter32 | read-only | This object indicates the number of packets received, but were discarded because of an unknown or unsupported protocol. |
| C32 gwModemOutOctets | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.18 | Counter32 | read-only | This object indicates the total number of octets transmitted, including the framing characters. |
| C32 gwModemOutUcastPkts | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.19 | Counter32 | read-only | This object indicates the total number of packets that higher-level protocols requested be transmitted to a subnetwork-unicast address, including those that were discarded or not sent. |
| C32 gwModemOutNUcastPkts | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.20 | Counter32 | read-only | This object indicates the total number of packets that higher-level protocols requested be transmitted to a non-unicast (i.e., a subnetwork-broadcast or subnetwork-multicast) address, including those that were discarded or not sent. |
| C32 gwModemOutDiscards | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.21 | Counter32 | read-only | This object indicates the number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being transmitted. One possible reason for discarding such a packet could be to free up buffer space. |
| C32 gwModemOutError | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.22 | Counter32 | read-only | This object indicates the number of outbound packets that could not be transmitted because of errors. |
| G32 gwModemOutQLen | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.23 | Gauge32 | read-only | This object indicates the number of packets in output packet queue. |
| I32 gwModemRoboByte40 | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.24 | Integer32 | read-only | This object indicates the current channel receive capacity of the Modem. |
| I32 gwModemRoboFails | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.25 | Integer32 | read-only | This object indicates the Powerline link receive failures of the Modem. |
| I32 gwModemRoboDrops | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.26 | Integer32 | read-only | This object indicates the Powerline link send failures of the Modem. |
| INT gwModemDeviceType | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.27 | INTEGER | read-only | This object indicates the Type of the Device registered to the Gateway 0 = Modem 1 = Repeater 2 = Other |
| OCT gwModemPSD | 1.3.6.1.4.1.161.19.3.8.1.1.9.1.28 | OCTET STRING | read-only | This object indicates the Software Version of the Modem. |
| whispPlvGatewayEvents | 1.3.6.1.4.1.161.19.3.8.1.2 | |||
| gwTrapPrefix | 1.3.6.1.4.1.161.19.3.8.1.2.0 | |||
| NTF gwTrapRegComplete | 1.3.6.1.4.1.161.19.3.8.1.2.0.1 | This Notification is generated if the Modem has successfully registered to the Gateway. | ||
| NTF gwTrapRegLost | 1.3.6.1.4.1.161.19.3.8.1.2.0.2 | This Notification is generated if the Modem entry is removed from the Gateway's Modem Table, after being inactive for a period more than 'gwConfModemTableTimeout' value. | ||
| NTF gwTrapDeviceUpgradeStarted | 1.3.6.1.4.1.161.19.3.8.1.2.0.3 | This Notification is generated if the Gateway has started the Device Firmware Upgrade process. | ||
| NTF gwTrapDeviceUpgradeCompleted | 1.3.6.1.4.1.161.19.3.8.1.2.0.4 | This Notification is generated once the Device Firmware Upgrade process is completed. | ||
| NTF gwTrapSimUpgradeStarted | 1.3.6.1.4.1.161.19.3.8.1.2.0.5 | This Notification is generated if the Gateway has started the Simple Module Firmware Upgrade process. | ||
| NTF gwTrapSimUpgradeCompleted | 1.3.6.1.4.1.161.19.3.8.1.2.0.6 | This Notification is generated once the Simple Module Firmware Upgrade process is completed. | ||
| whispPlvGatewayConformance | 1.3.6.1.4.1.161.19.3.8.1.3 | |||
| whispPlvGatewayGroups | 1.3.6.1.4.1.161.19.3.8.1.3.1 | |||
| whispPlvGatewayInfoGroup | 1.3.6.1.4.1.161.19.3.8.1.3.1.1 | The collection of objects that indicates Gateway device information. | ||
| whispPlvGatewayConfigGroup | 1.3.6.1.4.1.161.19.3.8.1.3.1.2 | The collection of objects used to configure the Gateway. These objects are accessible to everyone. | ||
| whispPlvGatewayTrapConfigGroup | 1.3.6.1.4.1.161.19.3.8.1.3.1.3 | The collection of Gateway's SNMP Trap Configuration objects. These objects are accessible to everyone. | ||
| whispPlvGatewayPowerlineGroup | 1.3.6.1.4.1.161.19.3.8.1.3.1.4 | The collection of Gateway's Powerline Statistics These objects are accessible to everyone. | ||
| whispPlvGatewayAdmConfigGroup | 1.3.6.1.4.1.161.19.3.8.1.3.1.5 | The collection of objects that are used to configure the Gateway. These objects are accessible only thru 'admin' community string. | ||
| whispPlvGatewayAdmLanConfigGroup | 1.3.6.1.4.1.161.19.3.8.1.3.1.6 | The collection of Gateway's LAN configuration objects. These objects are accessible only thru 'admin' community string. | ||
| whispPlvGatewayAdmSnmpAccessConfigGroup | 1.3.6.1.4.1.161.19.3.8.1.3.1.7 | The collection of objects that are used to configure the Gateway. These objects are accessible only thru 'admin' community string. | ||
| whispPlvGatewayAdmWanConfigGroup | 1.3.6.1.4.1.161.19.3.8.1.3.1.8 | The collection of Gateway's WAN configuration objects. These objects are accessible only thru 'admin' community string. | ||
| whispPlvGatewayAdmModemGroup | 1.3.6.1.4.1.161.19.3.8.1.3.1.9 | The collection of objects that gives information of the Modems connected to the Gateway. | ||
| whispPlvGatewayNotificationsGroup | 1.3.6.1.4.1.161.19.3.8.1.3.1.10 | The collection of Notifications generated by the Gateway. | ||
| whispPlvGatewayCompliances | 1.3.6.1.4.1.161.19.3.8.1.3.2 | |||
| whispPlvGatewayCompliance | 1.3.6.1.4.1.161.19.3.8.1.3.2.1 | The compliance statement of SNMP entities which implement the WHISP-PLV-GATEWAY-MIB. |
RFC description
Manages Canopy PLV (Proprietary Link VLAN) gateway device information and configuration.
Start monitoring Motorola WHISP PLV Gateway devices (firmware-version/trap-destination config status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.