All MIBs › TRANSMODE1100
Organization: Transmode Systems AB
Last Updated: 2003-10-06
Category: Carrier and Optical Transport
Description: Manages Transmode Systems 1100 optical transport node configuration, channel provisioning, and performance monitoring.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is TRANSMODE1100?
TRANSMODE1100 is Transmode Systems' enterprise MIB for its 1100-series optical transport node, a WDM/DWDM metro optical networking platform, covering channel provisioning, optical transport configuration, and performance monitoring for the node. It exposes configuration data (channel/wavelength provisioning) alongside performance-monitoring data typical of optical transport equipment, such as per-channel optical signal quality and transmission performance counters. Its role in hardware status monitoring is central to optical-transport operations: this class of MIB is used to track optical power levels, channel/laser status, and transmission errors so a degrading optical link or failing transceiver can be identified before it causes a service outage. It is a vendor-proprietary enterprise MIB rather than one built on a specific IETF optical-transport standard, though it operates in the same problem space as ITU-T optical transport monitoring concepts. It is deployed in metro/regional optical transport networks where Transmode 1100 nodes multiplex multiple client signals onto DWDM wavelengths for transport between sites. Network engineers evaluating or troubleshooting this functionality can download the TRANSMODE1100 file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in TRANSMODE1100. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Transmode 1100 optical transport node
Monitoring Examples
No specific object or table names were provided in the source excerpt for this module, so concrete identifiers cannot be cited. Based on its stated purpose covering channel provisioning and performance monitoring, an administrator would typically poll per-channel optical power/performance objects to catch a wavelength channel whose signal quality is degrading, which would show up as rising error counts or falling optical power before the channel fails outright.
What Can Be Monitored
- channel/wavelength provisioning status
- optical signal performance
- channel configuration
This MIB depends on
Related MIBs
Imported Objects
From SNMPv2-SMI
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| enterprises |
From SNMPv2-TC
| DateAndTime | |
| DisplayString | |
| TEXTUAL-CONVENTION |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| org | 1.3 | |||
| dod | 1.3.6 | |||
| internet | 1.3.6.1 | |||
| private | 1.3.6.1.4 | |||
| enterprises | 1.3.6.1.4.1 | |||
| transmode | 1.3.6.1.4.1.11857 | This is the enterprise specific MIB for Transmode | ||
| system1100 | 1.3.6.1.4.1.11857.1 | |||
| trmAlarmHandling | 1.3.6.1.4.1.11857.1.1 | |||
| trmAlarmConfig | 1.3.6.1.4.1.11857.1.1.1 | |||
| trmAlarmGeneral | 1.3.6.1.4.1.11857.1.1.1.1 | |||
| INT trmAutoAcknowledge | 1.3.6.1.4.1.11857.1.1.1.1.1 | INTEGER | read-write | Indicates if alarms should be automatically acknowledged or not. Can be on(1) or off(2). |
| INT trmClearAlarmLog | 1.3.6.1.4.1.11857.1.1.1.1.2 | INTEGER | read-write | Used to delete all history alarms. To delete all history alarms, a SetRequest-PDU with a clear(1) value encoding is used. |
| INT trmTemperature | 1.3.6.1.4.1.11857.1.1.1.1.3 | INTEGER | read-write | Indicates the temperature unit used in the system. Can be celsius(1) or farenheit(2). |
| INT trmAlarmTemperatureHigh | 1.3.6.1.4.1.11857.1.1.1.1.4 | INTEGER | read-write | High temperature level. This parameter indicates at what level a High temperature alarm will occur in the system. See trmTemperature if deg. Celsius or Farenheit is used. |
| INT trmAlarmTemperatureHighHyst | 1.3.6.1.4.1.11857.1.1.1.1.5 | INTEGER | read-write | High termperature hysteresis. This parameter is used together with trmAlarmTempemperatureHigh to decide when a High temperature alarm will cease. The alarm will cease at trmAlarmTemperatureHigh - trmAlarmTemperatureHighHyst. See trmTemperature if deg. Celsius or Farenheit is used. |
| INT trmAlarmTemperatureLow | 1.3.6.1.4.1.11857.1.1.1.1.6 | INTEGER | read-write | Low temperature level. This parameter indicates at what level a Low temperature alarm will occur in the system. See trmTemperature if deg. Celsius or Farenheit is used. |
| INT trmAlarmTemperatureLowHyst | 1.3.6.1.4.1.11857.1.1.1.1.7 | INTEGER | read-write | Low termperature hysteresis. This parameter is used together with trmAlarmTemperatureLow to decide when a Low temperature alarm will cease. The alarm will cease at trmAlarmTemperatureLow - trmAlarmTemperatureLowHyst. See trmTemperature if deg. Celsius or Farenheit is used. |
| INT trmPluginReset | 1.3.6.1.4.1.11857.1.1.1.1.8 | INTEGER | read-write | Used to reset all the plug in units. To reset all units, a SetRequest-PDU with a reset(1) value encoding is used. |
| INT trmOpticalInputPowerHighPINLine | 1.3.6.1.4.1.11857.1.1.1.1.9 | INTEGER | read-write | Optical input power high alarm level for line interface PINs. Value displayed and set is dBm/10. |
| INT trmOpticalInputPowerHighAPDLine | 1.3.6.1.4.1.11857.1.1.1.1.10 | INTEGER | read-write | Optical input power high alarm level for client interface APDs. Value displayed and set is dBm/10. |
| INT trmOpticalInputPowerLowPINLine | 1.3.6.1.4.1.11857.1.1.1.1.11 | INTEGER | read-write | Optical input power low alarm level for client interface PINs. Value displayed and set is dBm/10. |
| INT trmOpticalInputPowerLowAPDLine | 1.3.6.1.4.1.11857.1.1.1.1.12 | INTEGER | read-write | Optical input power low alarm level for client interface APDs. Value displayed and set is dBm/10. |
| CAS trmCascade | 1.3.6.1.4.1.11857.1.1.1.1.13 | CascadeMode | read-write | Shows if Cascading is activated or not and is also used to enable/diasable Cascading. activate(1) means activated and deactivate(2) means not activated. |
| CAS trmCascadeStatus | 1.3.6.1.4.1.11857.1.1.1.1.14 | CascadeStatus | read-only | Displays the current operating mode of the Cascading. Can be deactivated[1], initializing(2), ok(3) or failure(4). |
| INT trmOpticalInputPowerHighAPDLine2 | 1.3.6.1.4.1.11857.1.1.1.1.15 | INTEGER | read-write | Optical input power high alarm level for client interface APDs. Applicable for 76xx/15 units(repeaters). Value displayed and set is dBm/10. |
| INT trmOpticalInputPowerLowAPDLine2 | 1.3.6.1.4.1.11857.1.1.1.1.16 | INTEGER | read-write | Optical input power low alarm level for client interface APDs. Applicable for 76xx/15 units(repeaters). Value displayed and set is dBm/10. |
| INT trmOpticalInputPowerHigh850Client | 1.3.6.1.4.1.11857.1.1.1.1.17 | INTEGER | read-write | Optical input power high alarm level for 850 nm client interface. Value displayed and set is dBm/10. |
| INT trmOpticalInputPowerHigh1310Client | 1.3.6.1.4.1.11857.1.1.1.1.18 | INTEGER | read-write | Optical input power high alarm level for 1310 nm client interface. Value displayed and set is dBm/10. |
| INT trmOpticalInputPowerLow850Client | 1.3.6.1.4.1.11857.1.1.1.1.19 | INTEGER | read-write | Optical input power low alarm level for 850 nm client interface. Value displayed and set is dBm/10. |
| INT trmOpticalInputPowerLow1310Client | 1.3.6.1.4.1.11857.1.1.1.1.20 | INTEGER | read-write | Optical input power low alarm level for 1310 nm client interface. Value displayed and set is dBm/10. |
| trmAlarmSeverity | 1.3.6.1.4.1.11857.1.1.1.2 | |||
| trmAlarmSeverityTable | 1.3.6.1.4.1.11857.1.1.1.2.1 | not-accessible | A list of all type of alarms in the system. | |
| trmAlarmSeverityEntry | 1.3.6.1.4.1.11857.1.1.1.2.1.1 | not-accessible | A set of parameters that describe a alarm. | |
| INT trmAlarmSeverityId | 1.3.6.1.4.1.11857.1.1.1.2.1.1.1 | INTEGER | not-accessible | An id that uniquely identifies an alarm. |
| STR trmAlarmSeverityName | 1.3.6.1.4.1.11857.1.1.1.2.1.1.2 | DisplayString | read-only | The alarm name. |
| ALA trmAlarmSeverityLevel | 1.3.6.1.4.1.11857.1.1.1.2.1.1.3 | AlarmSeverity | read-write | Indicates the alarm severity. Can be set to critical (1) , major (2) , minor (3) , warning (4) or off(5) |
| trmAlarmExternal | 1.3.6.1.4.1.11857.1.1.1.3 | |||
| trmAlarmExternalTable | 1.3.6.1.4.1.11857.1.1.1.3.1 | not-accessible | A list of all external alarms. | |
| trmAlarmExternalEntry | 1.3.6.1.4.1.11857.1.1.1.3.1.1 | not-accessible | A set of parameters that describe a external alarm. | |
| INT trmAlarmExternalId | 1.3.6.1.4.1.11857.1.1.1.3.1.1.1 | INTEGER | not-accessible | An id that uniquely identifies an external alarm. 1 = External alarm 1, 2 = External alarm 2 and 3 = External alarm 3. |
| STR trmAlarmExternalName | 1.3.6.1.4.1.11857.1.1.1.3.1.1.2 | DisplayString | read-write | The External alarm name. Maximum number of characters is 20. |
| EXT trmAlarmExternalLevel | 1.3.6.1.4.1.11857.1.1.1.3.1.1.3 | ExternalAlarmLevel | read-write | Alarm level that activates the alarm. Can be activelow (1) or activehigh (2). |
| trmAlarmLog | 1.3.6.1.4.1.11857.1.1.2 | |||
| trmAlarmLogTable | 1.3.6.1.4.1.11857.1.1.2.1 | not-accessible | A table of history alarms in the system. The number of entries are as many as there are acknowledged alarms in the system. | |
| trmAlarmLogEntry | 1.3.6.1.4.1.11857.1.1.2.1.1 | not-accessible | A set of parameters that describe a history alarm. A row in this table can not be created or deleted by SNMP operations on columns of the table. | |
| INT trmAlarmLogIndex | 1.3.6.1.4.1.11857.1.1.2.1.1.1 | INTEGER | not-accessible | The index for this alarm entry. |
| RAC trmAlarmLogRackNumber | 1.3.6.1.4.1.11857.1.1.2.1.1.2 | RackNumber | read-only | The rack number where the alarm occured. |
| SLO trmAlarmLogSlotNumber | 1.3.6.1.4.1.11857.1.1.2.1.1.3 | SlotNumber | read-only | The slot number where the alarm occured. |
| STR trmAlarmLogName | 1.3.6.1.4.1.11857.1.1.2.1.1.4 | DisplayString | read-only | The alarm description. |
| PER trmAlarmLogSeverity | 1.3.6.1.4.1.11857.1.1.2.1.1.5 | PerceivedSeverity | read-only | The alarm severity. Can be indeterminate (0) , critical (1) , major (2) , minor (3) or warning (4). |
| STR trmAlarmLogUnit | 1.3.6.1.4.1.11857.1.1.2.1.1.6 | DisplayString | read-only | The type, version and index for the unit associated with the alarm. |
| STR trmAlarmLogSerialNumber | 1.3.6.1.4.1.11857.1.1.2.1.1.7 | DisplayString | read-only | The serial number for the unit associated with the alarm. |
| STR trmAlarmLogActTime | 1.3.6.1.4.1.11857.1.1.2.1.1.8 | DisplayString | read-only | The time the alarm was generated. |
| STR trmAlarmLogDeactTime | 1.3.6.1.4.1.11857.1.1.2.1.1.9 | DisplayString | read-only | The time the alarm was deactivated. |
| STR trmAlarmLogAckTime | 1.3.6.1.4.1.11857.1.1.2.1.1.10 | DisplayString | read-only | This time the alarm was acknowledged. |
| STR trmAlarmLogAckUser | 1.3.6.1.4.1.11857.1.1.2.1.1.11 | DisplayString | read-only | The user that acknowledged the alarm. |
| trmAlarmActive | 1.3.6.1.4.1.11857.1.1.3 | |||
| trmAlarmActiveGeneral | 1.3.6.1.4.1.11857.1.1.3.1 | |||
| INT trmAlarmActiveCounter | 1.3.6.1.4.1.11857.1.1.3.1.1 | INTEGER | read-only | Indicates the total number of active alarms in the system. |
| ALA trmAlarmActiveAcknowledgeAllDeact | 1.3.6.1.4.1.11857.1.1.3.1.2 | AlarmAcknowledge | read-write | Acknowledges all alarm that is not acknowledged and is deactivated. To acknowledge, a SetRequest-PDU with a yes(1) value encoding is used. |
| ALA trmAlarmActiveAcknowledgeAll | 1.3.6.1.4.1.11857.1.1.3.1.3 | AlarmAcknowledge | read-write | Acknowledgedges all alarms that is not acknowledged. To acknowledge, a SetRequest-PDU with a yes(1) value encoding is used. |
| trmAlarmActiveTable | 1.3.6.1.4.1.11857.1.1.3.2 | not-accessible | A table of active alarms in the system. With active alarm the meaning is a not acknowledged alarm. The number of entries are as many as there are not acknowledged alarms in the system. | |
| trmAlarmActiveEntry | 1.3.6.1.4.1.11857.1.1.3.2.1 | not-accessible | An entry in the table of active alarms in the system. A row in this table can not be created or deleted by SNMP operations on columns of the table. | |
| INT trmAlarmActiveIndex | 1.3.6.1.4.1.11857.1.1.3.2.1.1 | INTEGER | not-accessible | The index for this alarm entry. |
| RAC trmAlarmActiveRackNumber | 1.3.6.1.4.1.11857.1.1.3.2.1.2 | RackNumber | read-only | The rack number where the alarm occured. |
| SLO trmAlarmActiveSlotNumber | 1.3.6.1.4.1.11857.1.1.3.2.1.3 | SlotNumber | read-only | The slot number where the alarm occured. |
| STR trmAlarmActiveName | 1.3.6.1.4.1.11857.1.1.3.2.1.4 | DisplayString | read-only | The alarm description |
| PER trmAlarmActiveSeverity | 1.3.6.1.4.1.11857.1.1.3.2.1.5 | PerceivedSeverity | read-only | The alarm severity. Can be indeterminate (0) , critical (1) , major (2) , minor (3) or warning (4). |
| STR trmAlarmActiveUnit | 1.3.6.1.4.1.11857.1.1.3.2.1.6 | DisplayString | read-only | The type, version and index of the unit associated with the alarm. |
| STR trmAlarmActiveSerialNumber | 1.3.6.1.4.1.11857.1.1.3.2.1.7 | DisplayString | read-only | The serial number of the unit associated with the alarm. |
| STR trmAlarmActiveActTime | 1.3.6.1.4.1.11857.1.1.3.2.1.8 | DisplayString | read-only | The time the alarm was generated. |
| STR trmAlarmActiveDeactTime | 1.3.6.1.4.1.11857.1.1.3.2.1.9 | DisplayString | read-only | The time the alarm was deactivated. |
| ALA trmAlarmActiveAcknowledge | 1.3.6.1.4.1.11857.1.1.3.2.1.10 | AlarmAcknowledge | read-write | This oid is used to acknowledge a alarm. To acknowledge a alarm, a SetRequest-PDU with a acknowledge(1) value encoding is used. |
| trmSubrack | 1.3.6.1.4.1.11857.1.2 | |||
| trmSubrackList | 1.3.6.1.4.1.11857.1.2.1 | |||
| trmSubrackListTable | 1.3.6.1.4.1.11857.1.2.1.1 | not-accessible | A list of units present in the subrack(s). | |
| trmSubrackListEntry | 1.3.6.1.4.1.11857.1.2.1.1.1 | not-accessible | A set of parameters that describe a unit. | |
| RAC trmListRackNumber | 1.3.6.1.4.1.11857.1.2.1.1.1.1 | RackNumber | not-accessible | This object indicates in what rack the unit is situated in. |
| SLO trmListSlotNumber | 1.3.6.1.4.1.11857.1.2.1.1.1.2 | SlotNumber | not-accessible | This object indicates in what slot the unit is situated in. Can be slot 1-12. |
| PRE trmListUnitPresent | 1.3.6.1.4.1.11857.1.2.1.1.1.3 | Present | read-only | This object indicates if the unit is present yes(1) or not no(2). |
| STR trmListProductNumber | 1.3.6.1.4.1.11857.1.2.1.1.1.4 | DisplayString | read-only | The Product number of the unit (XXYY/ZZ) where: Board type = XX Board version = YY Board index = ZZ. |
| STR trmListProductDescription | 1.3.6.1.4.1.11857.1.2.1.1.1.5 | DisplayString | read-only | A product description of the unit. |
| STR trmListHwRevision | 1.3.6.1.4.1.11857.1.2.1.1.1.6 | DisplayString | read-only | The hardware revision of the unit. |
| STR trmListSerialNumber | 1.3.6.1.4.1.11857.1.2.1.1.1.7 | DisplayString | read-only | The serial number of the unit. |
| STR trmListManufacturingDate | 1.3.6.1.4.1.11857.1.2.1.1.1.8 | DisplayString | read-only | The manufacturing date of the unit. Format is Year:Week. |
| STR trmListSoftwareProdNo | 1.3.6.1.4.1.11857.1.2.1.1.1.9 | DisplayString | read-only | The software product number of the software on this unit. |
| STR trmListSwVersion | 1.3.6.1.4.1.11857.1.2.1.1.1.10 | DisplayString | read-only | Revision number of the software on this unit. |
| trmSubrackUnits | 1.3.6.1.4.1.11857.1.2.2 | |||
| trm6001 | 1.3.6.1.4.1.11857.1.2.2.1 | |||
| trm6001PM | 1.3.6.1.4.1.11857.1.2.2.1.1 | |||
| trm6001Table | 1.3.6.1.4.1.11857.1.2.2.1.1.1 | not-accessible | List of NMB(s). | |
| trm6001Entry | 1.3.6.1.4.1.11857.1.2.2.1.1.1.1 | not-accessible | A set of parameters that describes an NMB | |
| RAC trm6001RackNumber | 1.3.6.1.4.1.11857.1.2.2.1.1.1.1.1 | RackNumber | not-accessible | The network management board rack number. |
| SLO trm6001SlotNumber | 1.3.6.1.4.1.11857.1.2.2.1.1.1.1.2 | SlotNumberNmb | not-accessible | The network management board slot number. |
| STR trm6001IPAddress | 1.3.6.1.4.1.11857.1.2.2.1.1.1.1.3 | DisplayString | read-only | The network management board IP address. |
| STR trm6001MACAddress | 1.3.6.1.4.1.11857.1.2.2.1.1.1.1.4 | DisplayString | read-only | The network management board MAC address. |
| INT trm6001Temperature | 1.3.6.1.4.1.11857.1.2.2.1.1.1.1.5 | INTEGER | read-only | The network management board temperature in deg. C or deg. F. See trmTemperature if deg. Celsius or Farenheit is used. |
| STR trm6001UpTime | 1.3.6.1.4.1.11857.1.2.2.1.1.1.1.6 | DisplayString | read-only | The network management board up time. |
| TRM trm6001Date | 1.3.6.1.4.1.11857.1.2.2.1.1.1.1.7 | TrmDate | read-write | Used to set the NMB date on format YYYY-MM-DD. |
| TRM trm6001Time | 1.3.6.1.4.1.11857.1.2.2.1.1.1.1.8 | TrmTime | read-write | Used to set the NMB time on format HH:MM:SS. |
| INT trm6001SwReset | 1.3.6.1.4.1.11857.1.2.2.1.1.1.1.9 | INTEGER | read-write | Used to reset the NMB unit. To reset the NMB unit, a SetRequest-PDU with a reset(1) value encoding is used. |
| trm6001FM | 1.3.6.1.4.1.11857.1.2.2.1.2 | |||
| trm6001Traps | 1.3.6.1.4.1.11857.1.2.2.1.2.0 | |||
| NTF trm6001TrapExternal1 | 1.3.6.1.4.1.11857.1.2.2.1.2.0.1 | This trap is sent when a External 1 alarm is generated at the NMB 6001 unit. | ||
| NTF trm6001TrapExternal2 | 1.3.6.1.4.1.11857.1.2.2.1.2.0.2 | This trap is sent when a External 2 alarm is generated at the NMB 6001 unit. | ||
| NTF trm6001TrapExternal3 | 1.3.6.1.4.1.11857.1.2.2.1.2.0.3 | This trap is sent when a External 3 alarm is generated at the NMB 6001 unit. | ||
| NTF trm6001CascadeFailure | 1.3.6.1.4.1.11857.1.2.2.1.2.0.4 | This trap is sent when a attempt to enable Cascading has failed or connection is lost with the cascading rack. | ||
| trm9xxx | 1.3.6.1.4.1.11857.1.2.2.2 | |||
| trm9xxxPM | 1.3.6.1.4.1.11857.1.2.2.2.1 | |||
| trm9xxxTable | 1.3.6.1.4.1.11857.1.2.2.2.1.1 | not-accessible | A list of power supply units in the subrack(s). | |
| trm9xxxEntry | 1.3.6.1.4.1.11857.1.2.2.2.1.1.1 | not-accessible | A set of parameters that describe a power supply unit. | |
| RAC trm9xxxRackNumber | 1.3.6.1.4.1.11857.1.2.2.2.1.1.1.1 | RackNumber | not-accessible | This object indicates in what rack the power supply is situated in. |
| SLO trm9xxxSlotNumber | 1.3.6.1.4.1.11857.1.2.2.2.1.1.1.2 | SlotNumberPS | not-accessible | This object indicates in what slot number the power supply is situated in. Can be slot 10 or 11. |
| PRE trm9xxxPresent | 1.3.6.1.4.1.11857.1.2.2.2.1.1.1.3 | Present | read-only | This parameter indicates if the power supply is present or not. yes(1) means present and no(2) means not present. |
| POW trm9xxxType | 1.3.6.1.4.1.11857.1.2.2.2.1.1.1.4 | PowerType | read-only | This parameter describes what kind of power supply this unit is. Power9048(2) means a power supply with input pover 48 VDC, Power9220(3) means 100-240 VAC. If the type is unknown this parameter is unknown(1). |
| POW trm9xxxStatus | 1.3.6.1.4.1.11857.1.2.2.2.1.1.1.5 | PowerStatus | read-only | This parameter indicates the status of the power supply. off(1) means that the power supply not is operating and on(2) means that it is operating. |
| trm9xxxFM | 1.3.6.1.4.1.11857.1.2.2.2.2 | |||
| trm9xxxTraps | 1.3.6.1.4.1.11857.1.2.2.2.2.0 | |||
| NTF trm9xxxTrapFailure | 1.3.6.1.4.1.11857.1.2.2.2.2.0.1 | This trap indicates that a fault was detected on a power supply or the input power is removed. | ||
| NTF trm9xxxTrapMissing | 1.3.6.1.4.1.11857.1.2.2.2.2.0.2 | This trap is sent when a power supply is missing. | ||
| trm75xx | 1.3.6.1.4.1.11857.1.2.2.3 | |||
| trm75xxPM | 1.3.6.1.4.1.11857.1.2.2.3.1 | |||
| trm75xxTable | 1.3.6.1.4.1.11857.1.2.2.3.1.1 | not-accessible | A list of 70 & 75 units in the subrack(s). | |
| trm75xxEntry | 1.3.6.1.4.1.11857.1.2.2.3.1.1.1 | not-accessible | A set of parameters that describe a 70 or a 75 unit. | |
| RAC trm75xxRackNumber | 1.3.6.1.4.1.11857.1.2.2.3.1.1.1.1 | RackNumber | not-accessible | This parameter indicates in what rack the unit is situated in. |
| BOA trm75xxSlotNumber | 1.3.6.1.4.1.11857.1.2.2.3.1.1.1.2 | BoardNumber | not-accessible | This parameter indicates in what slot number the unit is situated in. Can be slot 1 - 8. |
| STR trm75xxRxLine | 1.3.6.1.4.1.11857.1.2.2.3.1.1.1.3 | DisplayString | read-only | This parameter indicates the status of the optical input for the line interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving. |
| STR trm75xxEstProtLine | 1.3.6.1.4.1.11857.1.2.2.3.1.1.1.4 | DisplayString | read-only | This parameter indicates the Estimated Protocol for the line interface input. |
| STR trm75xxEstFibRateLine | 1.3.6.1.4.1.11857.1.2.2.3.1.1.1.5 | DisplayString | read-only | This parameter indicates the Estimated Fiber Rate for the line interface input in Mbit/s. |
| STR trm75xxTxLine | 1.3.6.1.4.1.11857.1.2.2.3.1.1.1.6 | DisplayString | read-only | This parameter indicates the status of the optical output power for the line interface. It corresponds to the line Tx LED status of the unit. Can be on or off. |
| TXM trm75xxTxMode | 1.3.6.1.4.1.11857.1.2.2.3.1.1.1.7 | TxMode75 | read-write | This parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1) or disabled(2). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. |
| STR trm75xxWavelengthLine | 1.3.6.1.4.1.11857.1.2.2.3.1.1.1.8 | DisplayString | read-only | This parameter indicates the nominal wavelength for the line interface transiever. |
| STR trm75xxRxClient | 1.3.6.1.4.1.11857.1.2.2.3.1.1.1.9 | DisplayString | read-only | This parameter indicates the status of the optical input for the client interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving. |
| STR trm75xxEstProtClient | 1.3.6.1.4.1.11857.1.2.2.3.1.1.1.10 | DisplayString | read-only | This parameter indicates the Estimated Protocol for the client interface input. |
| STR trm75xxEstFibRateClient | 1.3.6.1.4.1.11857.1.2.2.3.1.1.1.11 | DisplayString | read-only | This parameter indicates the Estimated Fiber Rate for the client interface input in Mbit/s. |
| STR trm75xxTxClient | 1.3.6.1.4.1.11857.1.2.2.3.1.1.1.12 | DisplayString | read-only | This parameter indicates the status of the optical output power for the client interface. It corresponds to the client Tx LED status of the unit. Can be on or off. |
| TXM trm75xxTxModeClient | 1.3.6.1.4.1.11857.1.2.2.3.1.1.1.13 | TxMode75 | read-only | This object is obsolete and not used anymore. |
| STR trm75xxIDStringClient | 1.3.6.1.4.1.11857.1.2.2.3.1.1.1.14 | DisplayString | read-write | This parameter identifies the equipment(ID String) connected to the client interface. Maximum number of characters is 20. |
| STR trm75xxIPAddressClient | 1.3.6.1.4.1.11857.1.2.2.3.1.1.1.15 | DisplayString | read-write | This parameter indentifies the equipment(IP Address) connected to the client interface. |
| STR trm75xxWavelengthClient | 1.3.6.1.4.1.11857.1.2.2.3.1.1.1.16 | DisplayString | read-only | This parameter indicates the nominal wavelength for the client interface transiever. |
| SPE trm75xxSpeedLimit | 1.3.6.1.4.1.11857.1.2.2.3.1.1.1.17 | SpeedLimit75 | read-write | This parameter indicates the speed limit set for this unit and is used to set a new speed limit. It generates an alarm and disables Line and Client Tx if the Client bitrate is higher than a predefined protocol. The alarm is ceased and Tx is enabled again at a lower value (hysteresis). Speed Limit is deactivated if trm75xxTxMode is disabled(2). Speed Limit can be set in 3 modes to allow different protocols: noLimit(1): Any protocol is allowed. lowLimit(2): 100Base-FX, STM1/OC3, ESCON & Video 270Mb. mediumLimit(3): All protocols above + STM4/OC-12. |
| trm75xxFM | 1.3.6.1.4.1.11857.1.2.2.3.2 | |||
| trm75xxTraps | 1.3.6.1.4.1.11857.1.2.2.3.2.0 | |||
| NTF trm75xxTrapGlitchLine | 1.3.6.1.4.1.11857.1.2.2.3.2.0.1 | This trap is sent when a unit experiences a split second optical input power glitch at the line interface. | ||
| NTF trm75xxTrapLopLine | 1.3.6.1.4.1.11857.1.2.2.3.2.0.2 | This trap is sent when the optical input power is lost at the line interface. | ||
| NTF trm75xxTrapTxLine | 1.3.6.1.4.1.11857.1.2.2.3.2.0.3 | This trap is sent when a unit fails to generate optical output power at Tx line interface. | ||
| NTF trm75xxTrapTxDisableLine | 1.3.6.1.4.1.11857.1.2.2.3.2.0.4 | This trap is sent when the optical output power for the line interface is disabled. | ||
| NTF trm75xxTrapGlitchClient | 1.3.6.1.4.1.11857.1.2.2.3.2.0.5 | This trap is sent when a unit experiences a split second optical input power glitch at the client interface. | ||
| NTF trm75xxTrapLopClient | 1.3.6.1.4.1.11857.1.2.2.3.2.0.6 | This trap is sent when the optical input power is lost at the client interface. | ||
| NTF trm75xxTrapTxClient | 1.3.6.1.4.1.11857.1.2.2.3.2.0.7 | This trap is sent when a unit fails to generate optical output power at Tx client. | ||
| NTF trm75xxTrapTxDisableClient | 1.3.6.1.4.1.11857.1.2.2.3.2.0.8 | This trap is sent when the optical output power for the client interface is disabled. | ||
| trm76xx | 1.3.6.1.4.1.11857.1.2.2.4 | |||
| trm76xxPM | 1.3.6.1.4.1.11857.1.2.2.4.1 | |||
| trm76xxTable | 1.3.6.1.4.1.11857.1.2.2.4.1.1 | not-accessible | A list of 76YY/ZZ in the subrack(s). | |
| trm76xxEntry | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1 | not-accessible | A set of parameters that describe the Subrack units | |
| RAC trm76xxRackNumber | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.1 | RackNumber | not-accessible | This parameter indicates in what rack the unit is situated in. |
| BOA trm76xxSlotNumber | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.2 | BoardNumber | not-accessible | This parameter indicates in what slot number the unit is situated in. Can be any of slot 1 - 8. |
| INT trm76xxTemperature | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.3 | INTEGER | read-only | This parameter indicates the temperature measured by the unit in deg. C or deg. F. See trmSubrackConfigTemp if deg. Celsius or Farenheit is used. |
| CDR trm76xxCDR | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.4 | CDRMode | read-write | This parameter indicates the working mode of the CDR clock recovery circuit. Can be auto3R(1), bypass2R(2), custom(3),fddiOR100Base-FX(4), stm1orOC-3(5), video270Mbps(6), stm4orOC-12(7), gigabitEthernet(8), fibreChannel(9), fibreChannelx2(10), stm16orOC-48(11) or gigabitEthernetx2(12). custom(3) can not be set, it just indicates if a custom protocol is set with oid trm76xxCustomFibRate. |
| INT trm76xxCustomFibRate | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.5 | INTEGER | read-write | This parameter is used to set the working mode of the CDR clock recovery circuit(Custom mode). Custom mode can be set between 30000 and 2700000 Kbit/s. |
| TXM trm76xxTxMode | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.6 | TxMode76 | read-write | This parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. forcedon(3): Optical output is ON. (Normally, forcedon(3) is used for test purpose only) |
| LIN trm76xxLineLoopMode | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.7 | LineLoopMode | read-write | This parameter is used to set the line loop mode. Can be set to normal(1) or looptest(2). normal(1): The line loop test function is off. looptest(2): Line is looped, RX=TX. (Normally, Loop test is only used for installation, test purpose or fault-location). |
| INT trm76xxSwReset | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.8 | INTEGER | read-write | Used to reset the unit. To reset the unit, a SetRequest-PDU with a reset(1) value encoding is used. |
| STR trm76xxRxLine | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.9 | DisplayString | read-only | This parameter indicates the status of the optical input for the line interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving. |
| INT trm76xxOpticalInPowLine | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.10 | INTEGER | read-only | This parameter indicates the Optical input power for the line interface. When the Optical input power is to low to measure this parameter is -500 (-50 dBm). If the Optical output power is to high to measure this parameter is -20 (-2 dBm). If this parameter is invalid -1 (-0.1 dBm) is returned. Divide this value by 10 to show optical input power in dBm. |
| SPE trm76xxSpeedLimit | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.11 | SpeedLimit76 | read-write | This parameter indicates the speed limit set for this unit and is used to set a new speed limit. It generates an alarm and disables Line and Client Tx if the Client bitrate is higher than a predefined protocol. The alarm is ceased and Tx is enabled again at a lower value (hysteresis). Speed Limit is deactivated if trm76xxTxMode is disabled(2) or forcedon(3). Speed Limit can be set in 4 modes to allow different protocols: noLimit(1): Any protocol is allowed. lowLimit(2): 100Base-FX, STM1/OC3, ESCON & Video 270Mb. mediumLimit(3): All protocols above + STM4/OC-12. highLimit(4): All protocols above + Fibre channel & Gigabit Ethernet. |
| STR trm76xxEstProtLine | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.12 | DisplayString | read-only | This parameter indicates the Estimated Protocol for the line interface Rx. |
| STR trm76xxEstFibRateLine | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.13 | DisplayString | read-only | This parameter indicates the Estimated Fiber Rate for the line interface Rx in Mbit/s. |
| STR trm76xxTxLine | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.14 | DisplayString | read-only | This parameter indicates the status of the optical output power for the line interface. It corresponds to the line Tx LED status of the unit. Can be on or off. |
| INT trm76xxOpticalOutPowLine | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.15 | INTEGER | read-only | This parameter indicates the optical output power for the line interface. If data not is available yet this parameter is -1(-0.1 dBm). If this parameter is -100 (-10 dBm) the output power is equal too or less than -100 (-10 dBm). Divide this value by 10 to show the optical output power in dBm. |
| INT trm76xxProdOutPowLine | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.16 | INTEGER | read-only | This parameter indicates the production output power for the line interface. If data not is valid yet this parameter is -1 (-0.1 dBm). Divide this value by 10 to show the production output power in dBm. |
| INT trm76xxLaserBiasCurLine | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.17 | INTEGER | read-only | This parameter indicates the laser bias current for the line interface. If this parameter is 5450(545 mA) the laser bias current is more or equal to 545 mA. Divide this value by 10 to show the laser bias current in mA. |
| INT trm76xxProdLaserBiasCurLine | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.18 | INTEGER | read-only | This parameter indicates the production laser bias current for the line interface. Divide this value by 10 to show the laser bias current in mA. |
| STR trm76xxWavelengthLine | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.19 | DisplayString | read-only | This parameter indicates the nominal wavelength for the line interface transiever. |
| STR trm76xxRxClient | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.20 | DisplayString | read-only | This parameter indicates the status of the optical input for the client interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving. |
| STR trm76xxEstProtClient | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.21 | DisplayString | read-only | This parameter indicates the Estimated Protocol for the client interface Rx. |
| STR trm76xxEstFibRateClient | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.22 | DisplayString | read-only | This parameter indicates the Estimated Fiber Rate for the client interface Rx in Mbit/s. |
| STR trm76xxTxClient | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.23 | DisplayString | read-only | This parameter indicates the status of the optical output power for the client interface. It corresponds to the client Tx LED status of the unit. Can be on or off. |
| STR trm76xxIDStringClient | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.24 | DisplayString | read-write | This parameter identifies the equipment(ID String) connected to the client interface. Maximum number of characters is 20. |
| STR trm76xxIPAddressClient | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.25 | DisplayString | read-write | This parameter indentifies the equipment(IP Address) connected to the client interface. |
| STR trm76xxWavelengthClient | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.26 | DisplayString | read-only | This parameter indicates the nominal wavelength for the client interface transiever. |
| INT trm76xxOpticalInPowClient | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.27 | INTEGER | read-only | This parameter indicates the Optical input power for the client interface. When the Optical input power is to low to measure this parameter is -500 (-50 dBm). If the Optical output power is to high to measure this parameter is -20 (-2 dBm). If this parameter is invalid -1 (-0.1 dBm) is returned. Divide this value by 10 to show optical input power in dBm. |
| INT trm76xxOpticalOutPowClient | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.28 | INTEGER | read-only | This parameter indicates the optical output power for the client interface. If data not is available yet this parameter is -1(-0.1 dBm). If this parameter is -100 (-10 dBm) the output power is equal too or less than -100 (-10 dBm). Divide this value by 10 to show the optical output power in dBm. |
| INT trm76xxLaserBiasCurClient | 1.3.6.1.4.1.11857.1.2.2.4.1.1.1.29 | INTEGER | read-only | This parameter indicates the laser bias current for the client interface. If this parameter is 5450(545 mA) the laser bias current is more or equal to 545 mA. Divide this value by 10 to show the laser bias current in mA. |
| trm76xxFM | 1.3.6.1.4.1.11857.1.2.2.4.2 | |||
| trm76xxTraps | 1.3.6.1.4.1.11857.1.2.2.4.2.0 | |||
| NTF trm76xxTrapCDRAutoModeRangeChangeLine | 1.3.6.1.4.1.11857.1.2.2.4.2.0.1 | This trap is sent when a client equipment might be using a protocol not specified for auto mode or it might have changed the protocol. If auto mode is used consider goto manual mode instead. This trap concerns the regeneration at the Tx line output. | ||
| NTF trm76xxTrapRxGlitchLine | 1.3.6.1.4.1.11857.1.2.2.4.2.0.2 | This trap is sent when a unit experiences a split second optical input power glitch at the line interface. | ||
| NTF trm76xxTrapLopLine | 1.3.6.1.4.1.11857.1.2.2.4.2.0.3 | This trap is sent when the optical input power is lost at the line interface. | ||
| NTF trm76xxTrapRxHighPowerLine | 1.3.6.1.4.1.11857.1.2.2.4.2.0.4 | This trap is sent when the optical input power for line is higher than trmOpticalInputPowerHighPINLine or trmOpticalInputPowerHighAPDLine. | ||
| NTF trm76xxTrapRxLowPowerLine | 1.3.6.1.4.1.11857.1.2.2.4.2.0.5 | This trap is sent when the optical input power for line is lower than trmOpticalInputPowerLowPINLine or trmOpticalInputPowerLowAPDLine. | ||
| NTF trm76xxTrapLoLLine | 1.3.6.1.4.1.11857.1.2.2.4.2.0.6 | This trap is sent when the line Tx indicates loss of 3R synchronization. | ||
| NTF trm76xxTrapTxLine | 1.3.6.1.4.1.11857.1.2.2.4.2.0.7 | This trap is sent when a unit fails to generate optical output power at Tx line. | ||
| NTF trm76xxTrapSFPFailureLine | 1.3.6.1.4.1.11857.1.2.2.4.2.0.8 | This trap/alarm is not used in the system and is obsolete. | ||
| NTF trm76xxTrapSFPMissingLine | 1.3.6.1.4.1.11857.1.2.2.4.2.0.9 | This trap/alarm is not used in the system and is obsolete. | ||
| NTF trm76xxTrapCDRAutoModeRangeChangeClient | 1.3.6.1.4.1.11857.1.2.2.4.2.0.10 | This trap is sent when a client equipment might be using a protocol not specified for auto mode or it might have changed the protocol. If auto mode is used consider goto manual mode instead. This trap concerns the regeneration at the Tx client output. | ||
| NTF trm76xxTrapRxGlitchClient | 1.3.6.1.4.1.11857.1.2.2.4.2.0.11 | This trap is sent when a unit experiences a split second optical input power glitch at the client interface. | ||
| NTF trm76xxTrapLopClient | 1.3.6.1.4.1.11857.1.2.2.4.2.0.12 | This trap is sent when the optical input power is lost at the client interface. | ||
| NTF trm76xxTrapRxHighPowerClient | 1.3.6.1.4.1.11857.1.2.2.4.2.0.13 | This trap/alarm is not used in the system and the object is obsolete. | ||
| NTF trm76xxTrapRxLowPowerClient | 1.3.6.1.4.1.11857.1.2.2.4.2.0.14 | This trap/alarm is not used in the system and the object is obsolete. | ||
| NTF trm76xxTrapLoLClient | 1.3.6.1.4.1.11857.1.2.2.4.2.0.15 | This trap is sent when the client Tx indicates loss of 3R synchronization. | ||
| NTF trm76xxTrapTxClient | 1.3.6.1.4.1.11857.1.2.2.4.2.0.16 | This trap is sent when a unit fails to generate optical output power at Tx client. | ||
| NTF trm76xxTrapSFPFailureClient | 1.3.6.1.4.1.11857.1.2.2.4.2.0.17 | This trap is sent when a unit have a client SFP transiever got a failure or a Bias temperature alarm. | ||
| NTF trm76xxTrapSFPMissingClient | 1.3.6.1.4.1.11857.1.2.2.4.2.0.18 | This trap is sent when a unit doesn't have a client SFP transiever. | ||
| NTF trm76xxTrapTxDisable | 1.3.6.1.4.1.11857.1.2.2.4.2.0.19 | This trap is sent when the optical output power for both the line and client interface have been disabled. | ||
| NTF trm76xxTrapLaserDegradationLine | 1.3.6.1.4.1.11857.1.2.2.4.2.0.20 | This trap is sent when there is a laser degradation on the line laser. This means that the laser bias current is raised to be able to keep the optical output from the laser. | ||
| NTF trm76xxTrapEyeQualityLine | 1.3.6.1.4.1.11857.1.2.2.4.2.0.21 | For future use. | ||
| NTF trm76xxTrapEyeQualityClient | 1.3.6.1.4.1.11857.1.2.2.4.2.0.22 | For future use. | ||
| trm803x | 1.3.6.1.4.1.11857.1.2.2.5 | |||
| trm803xPM | 1.3.6.1.4.1.11857.1.2.2.5.1 | |||
| trm803xTable | 1.3.6.1.4.1.11857.1.2.2.5.1.1 | not-accessible | A list of 803x units. | |
| trm803xEntry | 1.3.6.1.4.1.11857.1.2.2.5.1.1.1 | not-accessible | A set of parameters that describe a 803x unit. | |
| RAC trm803xRackNumber | 1.3.6.1.4.1.11857.1.2.2.5.1.1.1.1 | RackNumber | not-accessible | This object indicates in what rack the 803x unit is situated in. |
| INT trm803xSlotNumber | 1.3.6.1.4.1.11857.1.2.2.5.1.1.1.2 | INTEGER | not-accessible | This object indicates in what slot number the 803x unitis situated in. Can only be slot 12. |
| MUX trm803xMuxType | 1.3.6.1.4.1.11857.1.2.2.5.1.1.1.3 | MuxType | read-only | This parameter indicates what Mux type this is. Can be none(1), mux8030(2), mux8031(3), mux8032(4), mux8033(5) or mux8034(6). |
| STR trm803xIDStringLine | 1.3.6.1.4.1.11857.1.2.2.5.1.1.1.4 | DisplayString | read-write | This parameter identifies the equipment connected to the line interface. The ID string can be used to indentify a fiber pair/link. Maximum number of characters is 20. |
| STR trm803xIPAddressLine | 1.3.6.1.4.1.11857.1.2.2.5.1.1.1.5 | DisplayString | read-write | This parameter identifies the equipment connected to the line interface. The IP address can be used to indentify the corresponding NMB unit. |
| trm2204 | 1.3.6.1.4.1.11857.1.2.2.6 | |||
| trm2204PM | 1.3.6.1.4.1.11857.1.2.2.6.1 | |||
| trm2204Table | 1.3.6.1.4.1.11857.1.2.2.6.1.1 | not-accessible | A list of 2204 units. | |
| trm2204Entry | 1.3.6.1.4.1.11857.1.2.2.6.1.1.1 | not-accessible | A set of parameters that describe a 2204 unit. | |
| RAC trm2204RackNumber | 1.3.6.1.4.1.11857.1.2.2.6.1.1.1.1 | RackNumber | not-accessible | This object indicates in what rack the 2204 unit is situated in. |
| INT trm2204SlotNumber | 1.3.6.1.4.1.11857.1.2.2.6.1.1.1.2 | INTEGER | not-accessible | This object indicates in what slot number the 2204 unitis situated in. Can be slot 1-8. |
| SEC trm2204SecurityMode | 1.3.6.1.4.1.11857.1.2.2.6.1.1.1.3 | SecurityMode | read-write | This parameter indicates the security mode for the unit. It is also used to set the Security Mode for the unit. Can be activated(1) or deactivated(2). |
| trm26xx | 1.3.6.1.4.1.11857.1.2.2.7 | |||
| trm26xxPM | 1.3.6.1.4.1.11857.1.2.2.7.1 | |||
| trm26xxTable | 1.3.6.1.4.1.11857.1.2.2.7.1.1 | not-accessible | A list of 26xx units in the subrack(s). | |
| trm26xxEntry | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1 | not-accessible | A set of parameters that describe a 26xx unit. | |
| RAC trm26xxRackNumber | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1.1 | RackNumber | not-accessible | This parameter indicates in what rack the unit is situated in. |
| BOA trm26xxSlotNumber | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1.2 | BoardNumber | not-accessible | This parameter indicates in what slot number the unit is situated in. Can be slot 1 - 8. |
| STR trm26xxStatus | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1.3 | DisplayString | read-only | This parameter indicates the status of the optical input for the line interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving. |
| INT trm26xxTemperature | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1.4 | INTEGER | read-only | The network management board temperature in deg. C or deg. F. See trmTemperature if deg. Celsius or Farenheit is used. |
| TXM trm26xxTxMode | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1.5 | TxMode75 | read-write | This parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1) or disabled(2). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. |
| INT trm26xxSwReset | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1.6 | INTEGER | read-write | Used to reset the unit. To reset the unit, a SetRequest-PDU with a reset(1) value encoding is used. |
| INT trm26xxOpticalPowerPIN1 | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1.7 | INTEGER | read-only | |
| INT trm26xxOpticalPowerPIN2 | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1.8 | INTEGER | read-only | |
| INT trm26xxLogOpticalPower | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1.9 | INTEGER | read-only | |
| INT trm26xxTemperatureTEC1 | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1.10 | INTEGER | read-only | |
| INT trm26xxTemperatureTEC2 | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1.11 | INTEGER | read-only | |
| INT trm26xxVoltageTEC1 | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1.12 | INTEGER | read-only | |
| INT trm26xxVoltageTEC2 | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1.13 | INTEGER | read-only | |
| INT trm26xxCurrentTEC1 | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1.14 | INTEGER | read-only | |
| INT trm26xxCurrentTEC2 | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1.15 | INTEGER | read-only | |
| INT trm26xxCurrentBIAS1 | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1.16 | INTEGER | read-only | |
| INT trm26xxCurrentBIAS2 | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1.17 | INTEGER | read-only | |
| INT trm26xxVoltageBIAS1 | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1.18 | INTEGER | read-only | |
| INT trm26xxVoltageBIAS2 | 1.3.6.1.4.1.11857.1.2.2.7.1.1.1.19 | INTEGER | read-only | |
| trm26xxFM | 1.3.6.1.4.1.11857.1.2.2.7.2 | |||
| trm26xxTraps | 1.3.6.1.4.1.11857.1.2.2.7.2.0 | |||
| NTF trm26xxTrapTEC1Faulty | 1.3.6.1.4.1.11857.1.2.2.7.2.0.1 | |||
| NTF trm26xxTrapTEC2Faulty | 1.3.6.1.4.1.11857.1.2.2.7.2.0.2 | |||
| NTF trm26xxTrapBIAS1Faulty | 1.3.6.1.4.1.11857.1.2.2.7.2.0.3 | |||
| NTF trm26xxTrapBIAS2Faulty | 1.3.6.1.4.1.11857.1.2.2.7.2.0.4 | |||
| NTF trm26xxTrapPIUTempShutdown | 1.3.6.1.4.1.11857.1.2.2.7.2.0.5 | |||
| NTF trm26xxTrapOpticalLinkdown | 1.3.6.1.4.1.11857.1.2.2.7.2.0.6 | |||
| NTF trm26xxTrapTxDisable | 1.3.6.1.4.1.11857.1.2.2.7.2.0.7 | This trap is sent when the amplifier has been disabled. | ||
| trm25xx | 1.3.6.1.4.1.11857.1.2.2.8 | |||
| trm25xxPM | 1.3.6.1.4.1.11857.1.2.2.8.1 | |||
| trm25xxTable | 1.3.6.1.4.1.11857.1.2.2.8.1.1 | not-accessible | A list of 25xx in the subrack(s). | |
| trm25xxEntry | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1 | not-accessible | A set of parameters that describe the Subrack units | |
| RAC trm25xxRackNumber | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1.1 | RackNumber | not-accessible | This parameter indicates in what rack the unit is situated in. |
| BOA trm25xxSlotNumber | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1.2 | BoardNumber | not-accessible | This parameter indicates in what slot number the unit is situated in. Can be any of slot 1 - 8. |
| STR trm25xxWorkingLineStatus | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1.3 | DisplayString | read-only | This parameter indicates the Working Line status. |
| STR trm25xxProtectingLineStatus | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1.4 | DisplayString | read-only | This parameter indicates the Protecting Line status. |
| INT trm25xxTemperature | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1.5 | INTEGER | read-only | This parameter indicates the temperature measured by the unit in deg. C or deg. F. See trmSubrackConfigTemp if deg. Celsius or Farenheit is used. |
| INT trm25xxSwReset | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1.6 | INTEGER | read-write | Used to reset the unit. To reset the unit, a SetRequest-PDU with a reset(1) value encoding is used. |
| STR trm25xxRxLine | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1.7 | DisplayString | read-only | This parameter indicates the status of the optical input for the line Subrack. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving. |
| INT trm25xxOpticalInPowLine | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1.8 | INTEGER | read-only | This parameter indicates the Optical input power for the line Subrack. When the Optical input power is to low to measure this parameter is -500 (-50 dBm). If the Optical output power is to high to measure this parameter is -20 (-2 dBm). If this parameter is invalid -1 (-0.1 dBm) is returned. Divide this value by 10 to show optical input power in dBm. |
| SPE trm25xxSpeedLimit | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1.9 | SpeedLimit76 | read-write | This parameter indicates the speed limit set for this unit and is used to set a new speed limit. It generates an alarm and disables Line and Client Tx if the Client bitrate is higher than a predefined protocol. The alarm is ceased and Tx is enabled again at a lower value (hysteresis). Speed Limit is deactivated if trm25xxTxMode is disabled(2) or forcedon(3). Speed Limit can be set in 4 modes to allow different protocols: noLimit(1): Any protocol is allowed. lowLimit(2): 100Base-FX, STM1/OC3, ESCON & Video 270Mb. mediumLimit(3): All protocols above + STM4/OC-12. highLimit(4): All protocols above + Fibre channel & Gigabit Ethernet. |
| STR trm25xxEstProtLine | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1.10 | DisplayString | read-only | This parameter indicates the Estimated Protocol for the line Subrack input. |
| STR trm25xxEstFibRateLine | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1.11 | DisplayString | read-only | This parameter indicates the Estimated Fiber Rate for the line Subrack input in Mbit/s. |
| STR trm25xxTxLine | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1.12 | DisplayString | read-only | This parameter indicates the status of the optical output power for the line Subrack. It corresponds to the line Tx LED status of the unit. Can be on or off. |
| INT trm25xxOpticalOutPowLine | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1.13 | INTEGER | read-only | This parameter indicates the optical output power for the line Subrack. If data not is available yet this parameter is -1(-0.1 dBm). If this parameter is -100 (-10 dBm) the output power is equal too or less than -100 (-10 dBm). Divide this value by 10 to show the optical output power in dBm. |
| INT trm25xxProdOutPowLine | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1.14 | INTEGER | read-only | This parameter indicates the production output power for the line Subrack. If data not is valid yet this parameter is -1 (-0.1 dBm). Divide this value by 10 to show the production output power in dBm. |
| INT trm25xxLaserBiasCurLine | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1.15 | INTEGER | read-only | This parameter indicates the laser bias current for the line Subrack. If this parameter is 5450(545 mA) the laser bias current is more or equal to 545 mA. Divide this value by 10 to show the laser bias current in mA. |
| INT trm25xxProdLaserBiasCurLine | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1.16 | INTEGER | read-only | This parameter indicates the production laser bias current for the line Subrack. Divide this value by 10 to show the laser bias current in mA. |
| CDR trm25xxCDR | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1.17 | CDRMode | read-write | This parameter indicates the working mode of the CDR clock recovery circuit. Can be auto3R(1), bypass2R(2), custom(3),fddiOR100Base-FX(4), stm1orOC-3(5), video270Mbps(6), stm4orOC-12(7), gigabitEthernet(8), fibreChannel(9), fibreChannelx2(10), stm16orOC-48(11) or gigabitEthernetx2(12). custom(3) can not be set, it just indicates if a custom protocol is set with oid trm25xxCustomFibRate. |
| INT trm25xxCustomFibRate | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1.18 | INTEGER | read-write | This parameter is used to set the working mode of the CDR clock recovery circuit(Custom mode). Custom mode can be set between 30000 and 2700000 Kbit/s. |
| TXM trm25xxTxMode | 1.3.6.1.4.1.11857.1.2.2.8.1.1.1.19 | TxMode76 | read-write | This parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. forcedon(3): Optical output is ON. (Normally, forcedon(3) is used for test purpose only) |
| trm25xxFM | 1.3.6.1.4.1.11857.1.2.2.8.2 | |||
| trm25xxTraps | 1.3.6.1.4.1.11857.1.2.2.8.2.0 | |||
| NTF trm25xxTrapWorkingLineFailure | 1.3.6.1.4.1.11857.1.2.2.8.2.0.1 | This trap is sent when the Working Line goes down. | ||
| NTF trm25xxTrapProtectingLineFailure | 1.3.6.1.4.1.11857.1.2.2.8.2.0.2 | This trap is sent when the Protecting Line goes down. | ||
| NTF trm25xxTrapWorkingAndProtectingLineFailure | 1.3.6.1.4.1.11857.1.2.2.8.2.0.3 | This trap is sent when both the Working and Protecting Line goes down. | ||
| trm53005500 | 1.3.6.1.4.1.11857.1.2.2.9 | |||
| trm53005500PM | 1.3.6.1.4.1.11857.1.2.2.9.1 | |||
| trm53005500Table | 1.3.6.1.4.1.11857.1.2.2.9.1.1 | not-accessible | A list of all 5300/01 and 5500/01 units in the subrack(s). | |
| trm53005500Entry | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1 | not-accessible | A set of parameters that describe a 5300/01 or 5500/01 unit. | |
| RAC trm53005500RackNumber | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.1 | RackNumber | not-accessible | This parameter indicates in what rack the unit is situated in. |
| BOA trm53005500SlotNumber | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.2 | BoardNumber | not-accessible | This parameter indicates in what slot number the unit is situated in. Can be any of slot 1 - 8. |
| INT trm53005500Temperature | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.3 | INTEGER | read-only | This parameter indicates the temperature measured by the unit in deg. C or deg. F. See trmSubrackConfigTemp if deg. Celsius or Farenheit is used. |
| INT trm53005500SwReset | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.4 | INTEGER | read-write | Used to reset the unit. To reset the unit, a SetRequest-PDU with a reset(1) value encoding is used. |
| STR trm53005500WavelengthLine | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.5 | DisplayString | read-only | This parameter indicates the nominal wavelength for the line interface transiever. |
| STR trm53005500RxLine | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.6 | DisplayString | read-only | This parameter indicates the status of the optical input for the line Subrack. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving. |
| INT trm53005500OpticalInPowLine | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.7 | INTEGER | read-only | This parameter indicates the Optical input power for the line interface. When the Optical input power is to low to measure this parameter is -500 (-50 dBm). If the Optical output power is to high to measure this parameter is -20 (-2 dBm). If this parameter is invalid -1 (-0.1 dBm) is returned. Divide this value by 10 to show optical input power in dBm. |
| STR trm53005500TxLine | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.8 | DisplayString | read-only | This parameter indicates the status of the optical output power for the line Subrack. It corresponds to the line Tx LED status of the unit. Can be on or off. |
| TXM trm53005500TxModeLine | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.9 | TxMode75 | read-write | This parameter indicates the mode of the optical transmitter for line TX. Can be set to normal(1) or disabled(2). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. |
| STR trm53005500WavelengthClient1 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.10 | DisplayString | read-only | This parameter indicates the nominal wavelength for the client 1 interface transiever. |
| STR trm53005500RxClient1 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.11 | DisplayString | read-only | This parameter indicates the status of the optical input for the client 1 interface. It corresponds to the client 1 Rx LED status of the unit. Can be Receiving or Not receiving. |
| CDR trm53005500CDRClient1 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.12 | CDR55Mode | read-write | This parameter indicates the working mode of the CDR clock recovery circuit and is used to change working mode. Only setable for unit 5500/01. Can be ESCON(1), stm1orOC-3(2), fddiOR100Base-FX(3), or syncClock16MHz(4). |
| STR trm53005500TxClient1 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.13 | DisplayString | read-only | This parameter indicates the status of the optical output power. It corresponds to the Tx LED status of the unit. Can be on or off. |
| TXM trm53005500TxModeClient1 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.14 | TxMode76 | read-write | This parameter indicates the mode of the optical transmitter for client 1 TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. forcedon(3): Optical output is ON. (Normally, forcedon(3) is used for test purpose only) |
| STR trm53005500IDStringClient1 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.15 | DisplayString | read-write | This parameter identifies the equipment(ID String) connected to the client 1 interface. Maximum number of characters is 20. |
| STR trm53005500IPAddressClient1 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.16 | DisplayString | read-write | This parameter indentifies the equipment(IP Address) connected to the client 1 interface. |
| STR trm53005500WavelengthClient2 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.17 | DisplayString | read-only | This parameter indicates the nominal wavelength for the client 2 interface transiever. |
| STR trm53005500RxClient2 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.18 | DisplayString | read-only | This parameter indicates the status of the optical input for the client 2 interface. It corresponds to the client 2 Rx LED status of the unit. Can be Receiving or Not receiving. |
| CDR trm53005500CDRClient2 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.19 | CDR55Mode | read-write | This parameter indicates the working mode of the CDR clock recovery circuit and is used to change working mode. Only setable for unit 5500/01. Can be ESCON(1), stm1orOC-3(2), fddiOR100Base-FX(3), or syncClock16MHz(4). |
| STR trm53005500TxClient2 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.20 | DisplayString | read-only | This parameter indicates the status of the optical output power. It corresponds to the Tx LED status of the unit. Can be on or off. |
| TXM trm53005500TxModeClient2 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.21 | TxMode76 | read-write | This parameter indicates the mode of the optical transmitter for client 2 TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. forcedon(3): Optical output is ON. (Normally, forcedon(3) is used for test purpose only) |
| STR trm53005500IDStringClient2 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.22 | DisplayString | read-write | This parameter identifies the equipment(ID String) connected to the client 2 interface. Maximum number of characters is 20. |
| STR trm53005500IPAddressClient2 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.23 | DisplayString | read-write | This parameter indentifies the equipment(IP Address) connected to the client 2 interface. |
| STR trm53005500WavelengthClient3 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.24 | DisplayString | read-only | This parameter indicates the nominal wavelength for the client 3 interface transiever. |
| STR trm53005500RxClient3 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.25 | DisplayString | read-only | This parameter indicates the status of the optical input for the client 3 interface. It corresponds to the client 3 Rx LED status of the unit. Can be Receiving or Not receiving. |
| CDR trm53005500CDRClient3 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.26 | CDR55Mode | read-write | This parameter indicates the working mode of the CDR clock recovery circuit and is used to change working mode. Only setable for unit 5500/01. Can be ESCON(1), stm1orOC-3(2), fddiOR100Base-FX(3), or syncClock16MHz(4). |
| STR trm53005500TxClient3 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.27 | DisplayString | read-only | This parameter indicates the status of the optical output power. It corresponds to the Tx LED status of the unit. Can be on or off. |
| TXM trm53005500TxModeClient3 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.28 | TxMode76 | read-write | This parameter indicates the mode of the optical transmitter for client 3 TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. forcedon(3): Optical output is ON. (Normally, forcedon(3) is used for test purpose only) |
| STR trm53005500IDStringClient3 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.29 | DisplayString | read-write | This parameter identifies the equipment(ID String) connected to the client 3 interface. Maximum number of characters is 20. |
| STR trm53005500IPAddressClient3 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.30 | DisplayString | read-write | This parameter indentifies the equipment(IP Address) connected to the client 3 interface. |
| STR trm53005500WavelengthClient4 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.31 | DisplayString | read-only | This parameter indicates the nominal wavelength for the client 4 interface transiever. |
| STR trm53005500RxClient4 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.32 | DisplayString | read-only | This parameter indicates the status of the optical input for the client 4 interface. It corresponds to the client 4 Rx LED status of the unit. Can be Receiving or Not receiving. |
| CDR trm53005500CDRClient4 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.33 | CDR55Mode | read-write | This parameter indicates the working mode of the CDR clock recovery circuit and is used to change working mode. Only setable for unit 5500/01. Can be ESCON(1), stm1orOC-3(2), fddiOR100Base-FX(3), or syncClock16MHz(4). |
| STR trm53005500TxClient4 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.34 | DisplayString | read-only | This parameter indicates the status of the optical output power. It corresponds to the Tx LED status of the unit. Can be on or off. |
| TXM trm53005500TxModeClient4 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.35 | TxMode76 | read-write | This parameter indicates the mode of the optical transmitter for client 4 TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. forcedon(3): Optical output is ON. (Normally, forcedon(3) is used for test purpose only) |
| STR trm53005500IDStringClient4 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.36 | DisplayString | read-write | This parameter identifies the equipment(ID String) connected to the client 4 interface. Maximum number of characters is 20. |
| STR trm53005500IPAddressClient4 | 1.3.6.1.4.1.11857.1.2.2.9.1.1.1.37 | DisplayString | read-write | This parameter indentifies the equipment(IP Address) connected to the client 4 interface. |
| trm53005500FM | 1.3.6.1.4.1.11857.1.2.2.9.2 | |||
| trm53005500Traps | 1.3.6.1.4.1.11857.1.2.2.9.2.0 | |||
| NTF trm53005500TrapRxLinkdownLine | 1.3.6.1.4.1.11857.1.2.2.9.2.0.1 | This trap is sent when the Line Rx signal is out of sync or has been lost. | ||
| NTF trm53005500TrapExternalsyncFailureLine | 1.3.6.1.4.1.11857.1.2.2.9.2.0.2 | This trap is sent when the Line external sync signal is lost or is out of sync. | ||
| NTF trm53005500TrapSfpMissingLine | 1.3.6.1.4.1.11857.1.2.2.9.2.0.3 | This trap is sent when the Line SFP transiever not is mounted. | ||
| NTF trm53005500TrapSfpBadTypeLine | 1.3.6.1.4.1.11857.1.2.2.9.2.0.4 | This trap is sent when a invalid Line SFP is used. | ||
| NTF trm53005500TrapSfpFaultyLine | 1.3.6.1.4.1.11857.1.2.2.9.2.0.5 | This trap is sent when the Line SFP is faulty. | ||
| NTF trm53005500TrapRxGlitchLine | 1.3.6.1.4.1.11857.1.2.2.9.2.0.6 | This trap is sent when a unit experiences a split second optical input power glitch at the Line interface. | ||
| NTF trm53005500TrapTxGlitchLine | 1.3.6.1.4.1.11857.1.2.2.9.2.0.7 | This trap is sent when a unit experiences a split second optical transmission glitch at the Line interface. | ||
| NTF trm53005500TrapTxDisabledLine | 1.3.6.1.4.1.11857.1.2.2.9.2.0.8 | This trap is sent when the optical output power for the line interface have been disabled. | ||
| NTF trm53005500TrapRxLinkDownClient1 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.9 | This trap is sent when the Client 1 Rx signal is out of sync or has been lost. | ||
| NTF trm53005500TrapTxOutOfSyncClient1 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.10 | This trap is sent when the Client 1 tx output signal is outside the selected frequencey range. | ||
| NTF trm53005500TrapSfpMissingClient1 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.11 | This trap is sent when the Client 1 SFP transiever not is mounted. | ||
| NTF trm53005500TrapSfpBadTypeClient1 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.12 | This trap is sent when a unsupported Client 1 SFP is used. | ||
| NTF trm53005500TrapSfpFaultyClient1 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.13 | This trap is sent when the Client 1 SFP is faulty. | ||
| NTF trm53005500TrapTxGlitchClient1 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.14 | This trap is sent when a unit experiences a split second optical transmission glitch at the Client 1 interface. | ||
| NTF trm53005500TrapRxGlitchClient1 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.15 | This trap is sent when a unit experiences a split second optical input power glitch at the Client 1 interface. | ||
| NTF trm53005500TrapTxDisabledClient1 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.16 | This trap is sent when the optical output power for the client 1 interface have been disabled. | ||
| NTF trm53005500TrapRxLinkDownClient2 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.17 | This trap is sent when the Client 2 Rx signal is out of sync or has been lost. | ||
| NTF trm53005500TrapTxOutOfSyncClient2 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.18 | This trap is sent when the Client 2 tx output signal is outside the selected frequencey range. | ||
| NTF trm53005500TrapSfpMissingClient2 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.19 | This trap is sent when the Client 2 SFP transiever not is mounted. | ||
| NTF trm53005500TrapSfpBadTypeClient2 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.20 | This trap is sent when a unsupported Client 2 SFP is used. | ||
| NTF trm53005500TrapSfpFaultyClient2 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.21 | This trap is sent when the Client 2 SFP is faulty. | ||
| NTF trm53005500TrapTxGlitchClient2 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.22 | This trap is sent when a unit experiences a split second optical transmission glitch at the Client 2 interface. | ||
| NTF trm53005500TrapRxGlitchClient2 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.23 | This trap is sent when a unit experiences a split second optical input power glitch at the Client 2 interface. | ||
| NTF trm53005500TrapTxDisabledClient2 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.24 | This trap is sent when the optical output power for the client 2 interface have been disabled. | ||
| NTF trm53005500TrapRxLinkDownClient3 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.25 | This trap is sent when the Client 3 Rx signal is out of sync or has been lost. | ||
| NTF trm53005500TrapTxOutOfSyncClient3 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.26 | This trap is sent when the Client 3 tx output signal is outside the selected frequencey range. | ||
| NTF trm53005500TrapSfpMissingClient3 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.27 | This trap is sent when the Client 3 SFP transiever not is mounted. | ||
| NTF trm53005500TrapSfpBadTypeClient3 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.28 | This trap is sent when a unsupported Client 3 SFP is used. | ||
| NTF trm53005500TrapSfpFaultyClient3 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.29 | This trap is sent when the Client 3 SFP is faulty. | ||
| NTF trm53005500TrapTxGlitchClient3 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.30 | This trap is sent when a unit experiences a split second optical transmission glitch at the Client 3 interface. | ||
| NTF trm53005500TrapRxGlitchClient3 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.31 | This trap is sent when a unit experiences a split second optical input power glitch at the Client 3 interface. | ||
| NTF trm53005500TrapTxDisabledClient3 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.32 | This trap is sent when the optical output power for the client 3 interface have been disabled. | ||
| NTF trm53005500TrapRxLinkDownClient4 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.33 | This trap is sent when the Client 4 Rx signal is out of sync or has been lost. | ||
| NTF trm53005500TrapTxOutOfSyncClient4 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.34 | This trap is sent when the Client 4 tx output signal is outside the selected frequencey range. | ||
| NTF trm53005500TrapSfpMissingClient4 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.35 | This trap is sent when the Client 4 SFP transiever not is mounted. | ||
| NTF trm53005500TrapSfpBadTypeClient4 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.36 | This trap is sent when a unsupported Client 4 SFP is used. | ||
| NTF trm53005500TrapSfpFaultyClient4 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.37 | This trap is sent when the Client 4 SFP is faulty. | ||
| NTF trm53005500TrapTxGlitchClient4 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.38 | This trap is sent when a unit experiences a split second optical transmission glitch at the Client 4 interface. | ||
| NTF trm53005500TrapRxGlitchClient4 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.39 | This trap is sent when a unit experiences a split second optical input power glitch at the Client 4 interface. | ||
| NTF trm53005500TrapTxDisabledClient4 | 1.3.6.1.4.1.11857.1.2.2.9.2.0.40 | This trap is sent when the optical output power for the client 4 interface have been disabled. | ||
| NTF trm53005500TrapHwFailure | 1.3.6.1.4.1.11857.1.2.2.9.2.0.41 | This trap is sent when the unit got a hardware failure. | ||
| trmSubrackFM | 1.3.6.1.4.1.11857.1.2.3 | |||
| trmSubrackTraps | 1.3.6.1.4.1.11857.1.2.3.0 | |||
| NTF trmTrapBmiLost | 1.3.6.1.4.1.11857.1.2.3.0.1 | This trap is sent when communication with a unit is lost. | ||
| NTF trmTrapBmiError | 1.3.6.1.4.1.11857.1.2.3.0.2 | This trap is sent when a internal BMI error occur. | ||
| NTF trmTrapHighTemp | 1.3.6.1.4.1.11857.1.2.3.0.3 | This trap is sent when a high temperature alarm occurs on the NMB 6001 unit or a unit with temperature measurement. | ||
| NTF trmTrapLowTemp | 1.3.6.1.4.1.11857.1.2.3.0.4 | This trap is sent when a low temperature alarm occurs on the NMB 6001 unit or a unit with temperature measurement. | ||
| NTF trmTrapVeryHighTemp | 1.3.6.1.4.1.11857.1.2.3.0.5 | This trap is sent when a very high temperature alarm occurs on the NMB 6001 unit or a unit with temperature measurement. | ||
| NTF trmTrapSpeedLimitExceeded | 1.3.6.1.4.1.11857.1.2.3.0.6 | This trap is sent if the Client bitrate is higher than a predefined protocol. When the alarm is activated Line and Client Tx is disabled. The alarm is ceased and Tx is enabled again at a lower value (hysteresis). Speed Limit is deactivated if Tx mode for the unit is disabled(2) or forcedon(3) |
RFC description
Enterprise MIB for Transmode optical transport equipment including alarm and performance management.
Start monitoring Transmode 1100 optical transport node (DWDM channel/optical-power status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.