TRANSMODE1100 DEFINITIONS ::= BEGIN IMPORTS DisplayString, TEXTUAL-CONVENTION, DateAndTime FROM SNMPv2-TC enterprises, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE FROM SNMPv2-SMI; transmode MODULE-IDENTITY LAST-UPDATED "200310061100Z" ORGANIZATION "Transmode Systems AB" CONTACT-INFO "http://www.transmode.com" DESCRIPTION "This is the enterprise specific MIB for Transmode" REVISION "200310061100Z" DESCRIPTION "Rev 1.2.9 06 Oct 2003 11:00 Changes in TEXTUAL-CONVENTION CDR55Mode." REVISION "200305131630Z" DESCRIPTION "Rev 1.2.8 04 Sep 2003 09:50 Added unit trm53005500. Added oids trmOpticalInputPowerHighAPDLine2, trmOpticalInputPowerLowAPDLine2, trmOpticalInputPowerHigh850Client, trmOpticalInputPowerLow850Client, trmOpticalInputPowerHigh1310Client, trmOpticalInputPowerLow1310Client, trm76xxOpticalInPowClient,trm76xxOpticalOutPowClient and trm76xxLaserBiasCurClient. Added disconnecting to TEXTUAL-CONVENTION CascadeStatus." REVISION "200305131630Z" DESCRIPTION "Rev 1.2.7 13 May 2003 16:30 Added new trap for 26xx, trm26xxTrapTxDisable." REVISION "200304041130Z" DESCRIPTION "Rev 1.2.6 4 Apr 2003 11:30 Added unit trm25xx." REVISION "200303261540Z" DESCRIPTION "Rev 1.2.5 26 Mar 2003 15:40 Added unit trm26xx." REVISION "200302201310Z" DESCRIPTION "Rev 1.2.4 20 Feb 2003 13:10 New oids trmCascade and trmCascadeStatus." REVISION "200211271445Z" DESCRIPTION "Rev 1.2.3 27 Nov 2002 14:45 New traps trm76xxTrapLaserDegradationLine, trm76xxTrapEyeQualityLine and trm76xxTrapEyeQualityClient" REVISION "200211181635Z" DESCRIPTION "Rev 1.2.2 18 Nov 2002 16:35 New oids trm75xxAlarmSpeedLimit and trm76xxAlarmSpeedLimit. trm76xxAlarmSpeedLimit replaced trm76xxOpticalInPowLineTxt. New trap trmTrapSpeedLimitExceeded. Renamed trm75xxTxModeLine to trm75xxTxMode. Made trm75xxTxModeClient obsolete and read-only. Removed trm76xxTrapSFPFailureLine, trm76xxTrapSFPMissingLine, trm76xxTrapRxHighPowerClient and trm76xxTrapHxLowPowerClient." REVISION "200211051520Z" DESCRIPTION "Rev 1.2.1 5 Nov 2002 15:20 New oids trmOpticalInputPowerHighPINLine, trmOpticalInputPowerHighAPDLine, trmOpticalInputPowerLowPINLine, trmOpticalInputPowerLowAPDLine Renamed oids trm76xxTrapRxOverloadLine to trm76xxTrapRxHighPowerLine. trm76xxTrapRxOverloadClient to trm76xxTrapRxHighPowerClient. " REVISION "200210301705Z" DESCRIPTION "Rev 1.2.0 30 Oct 2002 17:05 Renamed: trmAlarmConfiguration --> trmAlarmConfig trmGeneralConfig --> trmAlarmGeneral trmSeverityConfig --> trmAlarmSeverity and all its sub objects. trmExternalAlarms --> trmAlarmExternal and all its sub objects. trmActiveAlarm* --> trmAlarmActive* trmActiveGeneral --> trmAlarmActiveGeneral trmActivealarmNum --> trmAlarmActiveCounter trmSr* --> trmList* trmSubrackUnits --> trmUnits trmNMB6001* --> trm6001* trmAlarmNMB6001* --> trm6001Trap* trmPower* --> trm9xxx* trmAlarmPs* --> trm9xxxTrap* trmInterfaceUnits7075* --> trm75xx* trm7075* --> trm75xx* trmAlarmUnit7075* --> trm75xxTrap* trmInterfaceUnits76* --> trm76* trm76* --> trm76xx* trm76RegenerationMode --> trm76xxCDR trmAlarmUnit76* --> trm76xxTrap* trmMux803x* --> trm803x* trmAlarmBmiTraps --> trmSubrackTraps trmAlarmBmi* --> trmTrap* Moved and renamed: All sub objets from trmTempAlarms(old) to trmAlarmGeneral(new) and renamed Temp to AlarmTemperature. trmSubrackConfigTemperature(old) to trmAlarmGeneral(new) and renamed to trmTemperature. trmSubrackConfigPluginReset(old) to trmAlarmGeneral(new) and renamed to trmPluginReset. trmSubrackConfigNMBReset to trm6001Table and renamed to trm6001SwReset. Removed: trmTempAlarms New: trm6001Date trm6001Time trm803xMuxType trm2204 Changed type: trm76xxCDR(trm76RegenerationMode) from DisplayString to CDRMode trm76xxCustomFibRate(trm76CustomFibRate) from DisplayString to INTEGER " REVISION "200210231605Z" DESCRIPTION "Rev 1.1.1 23 Oct 2002 16:05 indeterminate (0) removed from AlarmSeverity. Renamed off(5) to none(5) in AlarmSeverity. Changed AlarmAcknowledge to {acknowledge(1)}. Changed trmAutoAcknowledge to on(1), off(2). trm76RegenerationMode changed to trm76CDR and made read-write. trm76CustomFibRate changed to INTEGER. " REVISION "200209301357Z" DESCRIPTION "Rev 1.1.0 30 Sep 2002 13:57 Changed TEXTUAL-CONVENTION LineLoopMode from forced(2) to looptest(2). Descriptions updated." ::= {enterprises 11857 } --************************************************************************* --************************************************************************* -- TEXTUAL-CONVENTIONS -- --************************************************************************* --************************************************************************* AlarmClass ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "The AlarmClass type categorizes the alarm, and is defined when the alarm is registered. It is as defined in X.733, ITU Alarm Reporting Function: o communications. An alarm of this class is principally associated with the procedures or processes required to convey information from one point to another. o qos. An alarm of this class is principally associated with a degradation in the quality of service. o processing. An alarm of this class is principally associated with a software or processing fault. o equipment. An alarm of this class is principally associated with an equipment fault. o environmental. An alarm of this class is principally associated with a condition relating to an enclosure in with equipment resides." SYNTAX INTEGER {unknown (0) , communications (1) , qos (2) , processing (3) , equipment (4) , environmental (5)} PerceivedSeverity ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "The PerceivedSeverity defines six severity levels, which provide an indication of how it is perceived that the capability of the managed object has been affected. Those severity levels which represent service affecting conditions ordered from most severe to least severe are critical, major, minor and warning. The levels used are as defined in X.733, ITU Alarm Reporting Function: o The Indeterminate severity level indicates that the severity level cannot be determined. o The Critical severity level indicates that a service affecting condition has occurred and an immediate corrective action is required. Such a severity can be reported, for example, when a managed object becomes totally out of service and its capability must be restored. o The Major severity level indicates that a service affecting condition has developed and an urgent corrective action is required. Such a severity can be reported, for example, when there is a severe degradation in the capability of the managed object and its full capability must be restored. o The Minor severity level indicates the existence of a non-service affecting fault condition and that corrective action should be taken in order to prevent a more serious (for example, service affecting) fault. Such a severity can be reported, for example, when the detected alarm condition is not currently degrading the capacity of the managed object. o The Warning severity level indicates the detection of a potential or impending service affecting fault, before any significant effects have been felt. Action should be taken to further diagnose (if necessary) and correct the problem in order to prevent it from becoming a more serious service affecting fault. o The Cleared severity level indicates the clearing of one or more previously reported alarms. This alarm clears all alarms for this managed object that have the same Alarm type, Probable cause and Specific problems (if given). When an alarm is cleared, an alarmCleared event is generated. This event clears the alarm with the AlarmActiveFaultId contained in the event. It is not required that the clearing of previously reported alarms are reported. Therefore, a managing system cannot assume that the absence of an alarmedCleared event for a fault means that the condition that caused the generation of previous alarms is still present. Managed object definers shall state if, and under which conditions, the alarmedCleared event is used. The clear value of AlarmSeverity is an action which is used when a management station wants to clear an active alarm. This is not possible on all systems, and thus an agent does not have support write access for this value." SYNTAX INTEGER {indeterminate (0) , critical (1) , major (2) , minor (3) , warning (4), cleared (5)} AlarmSeverity ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "The AlarmSeverity maps directly to the perceived severity field but includes an additional element for information alarms. See The perceived alarm severity textual convention for a description of the other types. o The information severity level indicates an event of information character.No action has to be taken." SYNTAX INTEGER {critical (1) , major (2) , minor (3) , warning (4), none(5)} RowStatus ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "" SYNTAX INTEGER {active (1) , notInService (2) , notReady (3) , createAndGo (4) , createAndWait (5) , destroy (6)} OwnerString ::= TEXTUAL-CONVENTION DISPLAY-HINT "255a" STATUS current DESCRIPTION "An OwnerString identifies the initiator or owner of a row in a table. This label is set by the initiator to provide for the following possibilities: o A management station may recognize resources it owns and no longer needs. o A network operator can find the management station that owns the resource and negotiate for it to be freed. o A network operator may decide to unilaterally free resources another network operator has reserved. o Upon initialization, a management station may recognize resources it had reserved in the past. With this information it may free the resources if it no longer needs them. Management stations and agent systems should support any format of the OwnerString dictated by the local policy of the organization. It is suggested that this name contain one or more of the following: IP address, management station name, network manager's name, location, or phone number. This information will help users to share the resources more effectively. There is often default functionality that the device or the administrator of the agent (often the network administrator) wishes to set up. The resources associated with this functionality are then owned by the device itself or by the network administrator, and are intended to be long-lived. In this case, the device or the administrator will set the relevant owner object to a string starting with 'local'. Indiscriminate modification of the local configuration by network management stations is discouraged. In fact, a network management station should only modify these objects under the direction of the administrator of the agent system." SYNTAX DisplayString (SIZE (0 .. 127 )) TrafficStatus ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Traffic Status. Indicates if there is traffic(2) or not, notraffic(1)." SYNTAX INTEGER {notraffic (1) , traffic (2)} TxMode76 ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Mode of the optical transmitter. normal(1) = On if Receiving signal. disabled(2) = Always off. enabled(3) = Always on(testmode)." SYNTAX INTEGER {normal (1) , disabled (2) , forcedon (3) } TxMode75 ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Mode of the optical transmitter. normal(1)= On if Receiving signal. disabled (2) = Always off." SYNTAX INTEGER {normal (1) , disabled (2) } Present ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Indicates if a unit is present(yes) or not(no)." SYNTAX INTEGER {yes (1) , no (2)} PowerStatus ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Power Status. Indicates if power is on or off" SYNTAX INTEGER {off (1) , on (2)} PowerType ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Power Type. Indicates the type of power." SYNTAX INTEGER {unknown (1), power9048 (2) , power9220 (3), power9148(4), power9122(5)} MuxType ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Mux Type. Indicates the Mux type." SYNTAX INTEGER {none (1), mux8030 (2) , mux8031 (3) , mux8032(4) , mux8033(5), mux8034(6) } ExternalAlarmLevel ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "External alarm level. Indicates at which level a alarm shoud be active on" SYNTAX INTEGER {activelow (1) , activehigh (2)} AlarmStatus ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Switch, that can be active or ceased" SYNTAX INTEGER {active (1) , ceased (2)} Switch ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Switch, that can be turned either on or off" SYNTAX INTEGER {off (1) , on (2)} PortType ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Type of port" SYNTAX INTEGER {line (1) , client (2)} RackNumber ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Rack Number" SYNTAX INTEGER (1..5) SlotNumber ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Slot position in rack" SYNTAX INTEGER (1..17) BoardNumber ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Board position in rack" SYNTAX INTEGER (1..12) SlotNumberPS ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Power supply slot position in rack" SYNTAX INTEGER (10..15) SlotNumberNmb ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Network management board slot position in rack" SYNTAX INTEGER (9..13) AlarmAcknowledge ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Indicates if a alarm is acknowledged or not. Can be either yes or no" SYNTAX INTEGER {acknowledge (1)} LineLoopMode ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Line loop mode can be normal(1) or forced(2)." SYNTAX INTEGER {normal (1) , looptest (2)} CDRMode ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Different CDR settings." SYNTAX INTEGER { auto3R(1), bypass2R(2), custom(3),fddiOR100Base-FX(4), stm1orOC-3(5), video270Mbps(6), stm4orOC-12(7), gigabitEthernet(8), fibreChannel(9), fibreChannelx2(10), stm16orOC-48(11), gigabitEthernetx2(12) } TrmDate ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Date on format YYYY-MM-DD." SYNTAX DisplayString (SIZE (0..10)) TrmTime ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Date on format HH:MM:SS." SYNTAX DisplayString (SIZE(0..8)) SecurityMode ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Security Mode." SYNTAX INTEGER { activated(1), deactivated(2) } SpeedLimit75 ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Speed Limit." SYNTAX INTEGER { noLimit(1), lowLimit(2), mediumLimit(3) } SpeedLimit76 ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Speed Limit." SYNTAX INTEGER { noLimit(1), lowLimit(2), mediumLimit(3), highLimit(4) } CascadeStatus ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Cascade status." SYNTAX INTEGER { deactivated(1), initializing(2), ok(3), failure(4), disconnecting(5) } CascadeMode ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Cascade Mode." SYNTAX INTEGER { activate(1), deactivate(2) } CDR55Mode ::= TEXTUAL-CONVENTION DISPLAY-HINT "" STATUS current DESCRIPTION "Different CDR settings." SYNTAX INTEGER { escon(1), stm1orOC-3(2), fddiOR100Base-FX(3),syncSignal16-32Mbps(4)} --********************************************************************************************* --********************************************************************************************* -- Tree --********************************************************************************************* --********************************************************************************************* org OBJECT IDENTIFIER ::= {iso 3 } dod OBJECT IDENTIFIER ::= {org 6 } internet OBJECT IDENTIFIER ::= {dod 1 } private OBJECT IDENTIFIER ::= {internet 4 } enterprises OBJECT IDENTIFIER ::= {private 1 } system1100 OBJECT IDENTIFIER ::= {transmode 1 } --********************************************************************************************* --********************************************************************************************* -- Alarm handling --********************************************************************************************* --********************************************************************************************* trmAlarmHandling OBJECT IDENTIFIER ::= {system1100 1 } trmAlarmConfig OBJECT IDENTIFIER ::= {trmAlarmHandling 1 } trmAlarmLog OBJECT IDENTIFIER ::= {trmAlarmHandling 2 } trmAlarmActive OBJECT IDENTIFIER ::= {trmAlarmHandling 3 } -- Alarm Configuration trmAlarmGeneral OBJECT IDENTIFIER ::= {trmAlarmConfig 1 } trmAutoAcknowledge OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if alarms should be automatically acknowledged or not. Can be on(1) or off(2)." ::= {trmAlarmGeneral 1 } trmClearAlarmLog OBJECT-TYPE SYNTAX INTEGER { clear(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to delete all history alarms. To delete all history alarms, a SetRequest-PDU with a clear(1) value encoding is used." ::= {trmAlarmGeneral 2 } trmTemperature OBJECT-TYPE SYNTAX INTEGER { celsius(1), farenheit(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the temperature unit used in the system. Can be celsius(1) or farenheit(2)." ::= {trmAlarmGeneral 3 } trmAlarmTemperatureHigh OBJECT-TYPE SYNTAX INTEGER (-32767 .. 32768 ) MAX-ACCESS read-write STATUS current DESCRIPTION "High temperature level. This parameter indicates at what level a High temperature alarm will occur in the system. See trmTemperature if deg. Celsius or Farenheit is used." ::= {trmAlarmGeneral 4 } trmAlarmTemperatureHighHyst OBJECT-TYPE SYNTAX INTEGER (-32767 .. 32768 ) MAX-ACCESS read-write STATUS current DESCRIPTION "High termperature hysteresis. This parameter is used together with trmAlarmTempemperatureHigh to decide when a High temperature alarm will cease. The alarm will cease at trmAlarmTemperatureHigh - trmAlarmTemperatureHighHyst. See trmTemperature if deg. Celsius or Farenheit is used." ::= {trmAlarmGeneral 5 } trmAlarmTemperatureLow OBJECT-TYPE SYNTAX INTEGER (-32767 .. 32768 ) MAX-ACCESS read-write STATUS current DESCRIPTION "Low temperature level. This parameter indicates at what level a Low temperature alarm will occur in the system. See trmTemperature if deg. Celsius or Farenheit is used." ::= {trmAlarmGeneral 6 } trmAlarmTemperatureLowHyst OBJECT-TYPE SYNTAX INTEGER (-32767 .. 32768 ) MAX-ACCESS read-write STATUS current DESCRIPTION "Low termperature hysteresis. This parameter is used together with trmAlarmTemperatureLow to decide when a Low temperature alarm will cease. The alarm will cease at trmAlarmTemperatureLow - trmAlarmTemperatureLowHyst. See trmTemperature if deg. Celsius or Farenheit is used." ::= {trmAlarmGeneral 7 } trmPluginReset OBJECT-TYPE SYNTAX INTEGER { reset(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to reset all the plug in units. To reset all units, a SetRequest-PDU with a reset(1) value encoding is used." ::= {trmAlarmGeneral 8 } trmOpticalInputPowerHighPINLine OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Optical input power high alarm level for line interface PINs. Value displayed and set is dBm/10." ::= {trmAlarmGeneral 9 } trmOpticalInputPowerHighAPDLine OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Optical input power high alarm level for client interface APDs. Value displayed and set is dBm/10." ::= {trmAlarmGeneral 10 } trmOpticalInputPowerLowPINLine OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Optical input power low alarm level for client interface PINs. Value displayed and set is dBm/10." ::= {trmAlarmGeneral 11 } trmOpticalInputPowerLowAPDLine OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Optical input power low alarm level for client interface APDs. Value displayed and set is dBm/10." ::= {trmAlarmGeneral 12 } trmCascade OBJECT-TYPE SYNTAX CascadeMode MAX-ACCESS read-write STATUS current DESCRIPTION "Shows if Cascading is activated or not and is also used to enable/diasable Cascading. activate(1) means activated and deactivate(2) means not activated." ::= {trmAlarmGeneral 13 } trmCascadeStatus OBJECT-TYPE SYNTAX CascadeStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the current operating mode of the Cascading. Can be deactivated[1], initializing(2), ok(3) or failure(4)." ::= {trmAlarmGeneral 14 } trmOpticalInputPowerHighAPDLine2 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Optical input power high alarm level for client interface APDs. Applicable for 76xx/15 units(repeaters). Value displayed and set is dBm/10." ::= {trmAlarmGeneral 15 } trmOpticalInputPowerLowAPDLine2 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Optical input power low alarm level for client interface APDs. Applicable for 76xx/15 units(repeaters). Value displayed and set is dBm/10." ::= {trmAlarmGeneral 16 } trmOpticalInputPowerHigh850Client OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Optical input power high alarm level for 850 nm client interface. Value displayed and set is dBm/10." ::= {trmAlarmGeneral 17 } trmOpticalInputPowerHigh1310Client OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Optical input power high alarm level for 1310 nm client interface. Value displayed and set is dBm/10." ::= {trmAlarmGeneral 18 } trmOpticalInputPowerLow850Client OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Optical input power low alarm level for 850 nm client interface. Value displayed and set is dBm/10." ::= {trmAlarmGeneral 19 } trmOpticalInputPowerLow1310Client OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Optical input power low alarm level for 1310 nm client interface. Value displayed and set is dBm/10." ::= {trmAlarmGeneral 20 } trmAlarmSeverity OBJECT IDENTIFIER ::= {trmAlarmConfig 2 } trmAlarmSeverityTable OBJECT-TYPE SYNTAX SEQUENCE OF TrmAlarmSeverityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of all type of alarms in the system." ::= {trmAlarmSeverity 1} trmAlarmSeverityEntry OBJECT-TYPE SYNTAX TrmAlarmSeverityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of parameters that describe a alarm." INDEX {trmAlarmSeverityId } ::= {trmAlarmSeverityTable 1} TrmAlarmSeverityEntry ::= SEQUENCE { trmAlarmSeverityId INTEGER, trmAlarmSeverityName DisplayString, trmAlarmSeverityLevel AlarmSeverity } trmAlarmSeverityId OBJECT-TYPE SYNTAX INTEGER (1 .. 2147483647 ) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An id that uniquely identifies an alarm." ::= {trmAlarmSeverityEntry 1 } trmAlarmSeverityName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm name." ::= {trmAlarmSeverityEntry 2 } trmAlarmSeverityLevel OBJECT-TYPE SYNTAX AlarmSeverity MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the alarm severity. Can be set to critical (1) , major (2) , minor (3) , warning (4) or off(5)" ::= {trmAlarmSeverityEntry 3 } trmAlarmExternal OBJECT IDENTIFIER ::= {trmAlarmConfig 3 } trmAlarmExternalTable OBJECT-TYPE SYNTAX SEQUENCE OF TrmAlarmExternalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of all external alarms." ::= {trmAlarmExternal 1} trmAlarmExternalEntry OBJECT-TYPE SYNTAX TrmAlarmExternalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of parameters that describe a external alarm." INDEX {trmAlarmExternalId } ::= {trmAlarmExternalTable 1} TrmAlarmExternalEntry ::= SEQUENCE { trmAlarmExternalId INTEGER, trmAlarmExternalName DisplayString, trmAlarmExternalLevel ExternalAlarmLevel } trmAlarmExternalId OBJECT-TYPE SYNTAX INTEGER (1 .. 2147483647 ) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An id that uniquely identifies an external alarm. 1 = External alarm 1, 2 = External alarm 2 and 3 = External alarm 3." ::= {trmAlarmExternalEntry 1 } trmAlarmExternalName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The External alarm name. Maximum number of characters is 20." ::= {trmAlarmExternalEntry 2 } trmAlarmExternalLevel OBJECT-TYPE SYNTAX ExternalAlarmLevel MAX-ACCESS read-write STATUS current DESCRIPTION "Alarm level that activates the alarm. Can be activelow (1) or activehigh (2)." ::= {trmAlarmExternalEntry 3 } -- The AlarmLog group -- -- The Alarm group is a collection of objects for monitoring of -- history alarms in the system. trmAlarmLogTable OBJECT-TYPE SYNTAX SEQUENCE OF TrmAlarmLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of history alarms in the system. The number of entries are as many as there are acknowledged alarms in the system." ::= {trmAlarmLog 1} trmAlarmLogEntry OBJECT-TYPE SYNTAX TrmAlarmLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of parameters that describe a history alarm. A row in this table can not be created or deleted by SNMP operations on columns of the table." INDEX {trmAlarmLogIndex } ::= {trmAlarmLogTable 1} TrmAlarmLogEntry ::= SEQUENCE { trmAlarmLogIndex INTEGER, trmAlarmLogRackNumber RackNumber, trmAlarmLogSlotNumber SlotNumber, trmAlarmLogName DisplayString, trmAlarmLogSeverity PerceivedSeverity, trmAlarmLogUnit DisplayString, trmAlarmLogSerialNumber DisplayString, trmAlarmLogActTime DisplayString, trmAlarmLogDeactTime DisplayString, trmAlarmLogAckTime DisplayString, trmAlarmLogAckUser DisplayString } trmAlarmLogIndex OBJECT-TYPE SYNTAX INTEGER (1 .. 2147483647 ) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index for this alarm entry." ::= {trmAlarmLogEntry 1 } trmAlarmLogRackNumber OBJECT-TYPE SYNTAX RackNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The rack number where the alarm occured." ::= {trmAlarmLogEntry 2 } trmAlarmLogSlotNumber OBJECT-TYPE SYNTAX SlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The slot number where the alarm occured." ::= {trmAlarmLogEntry 3 } trmAlarmLogName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm description." ::= {trmAlarmLogEntry 4 } trmAlarmLogSeverity OBJECT-TYPE SYNTAX PerceivedSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm severity. Can be indeterminate (0) , critical (1) , major (2) , minor (3) or warning (4)." ::= {trmAlarmLogEntry 5 } trmAlarmLogUnit OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The type, version and index for the unit associated with the alarm." ::= {trmAlarmLogEntry 6 } trmAlarmLogSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number for the unit associated with the alarm." ::= {trmAlarmLogEntry 7 } trmAlarmLogActTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The time the alarm was generated." ::= {trmAlarmLogEntry 8 } trmAlarmLogDeactTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The time the alarm was deactivated." ::= {trmAlarmLogEntry 9 } trmAlarmLogAckTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This time the alarm was acknowledged." ::= {trmAlarmLogEntry 10 } trmAlarmLogAckUser OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The user that acknowledged the alarm." ::= {trmAlarmLogEntry 11 } -- The AlarmActive group -- -- The AlarmActive group is a collection of objects for monitoring of -- active alarms in the system. trmAlarmActiveGeneral OBJECT IDENTIFIER ::= {trmAlarmActive 1 } trmAlarmActiveCounter OBJECT-TYPE SYNTAX INTEGER (-1 .. 32768 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the total number of active alarms in the system." ::= {trmAlarmActiveGeneral 1 } trmAlarmActiveAcknowledgeAllDeact OBJECT-TYPE SYNTAX AlarmAcknowledge MAX-ACCESS read-write STATUS current DESCRIPTION "Acknowledges all alarm that is not acknowledged and is deactivated. To acknowledge, a SetRequest-PDU with a yes(1) value encoding is used." ::= {trmAlarmActiveGeneral 2 } trmAlarmActiveAcknowledgeAll OBJECT-TYPE SYNTAX AlarmAcknowledge MAX-ACCESS read-write STATUS current DESCRIPTION "Acknowledgedges all alarms that is not acknowledged. To acknowledge, a SetRequest-PDU with a yes(1) value encoding is used." ::= {trmAlarmActiveGeneral 3 } trmAlarmActiveTable OBJECT-TYPE SYNTAX SEQUENCE OF TrmAlarmActiveEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of active alarms in the system. With active alarm the meaning is a not acknowledged alarm. The number of entries are as many as there are not acknowledged alarms in the system." ::= {trmAlarmActive 2} trmAlarmActiveEntry OBJECT-TYPE SYNTAX TrmAlarmActiveEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table of active alarms in the system. A row in this table can not be created or deleted by SNMP operations on columns of the table." INDEX {trmAlarmActiveIndex } ::= {trmAlarmActiveTable 1} TrmAlarmActiveEntry ::= SEQUENCE { trmAlarmActiveIndex INTEGER, trmAlarmActiveRackNumber RackNumber, trmAlarmActiveSlotNumber SlotNumber, trmAlarmActiveName DisplayString, trmAlarmActiveSeverity PerceivedSeverity, trmAlarmActiveUnit DisplayString, trmAlarmActiveSerialNumber DisplayString, trmAlarmActiveActTime DisplayString, trmAlarmActiveDeactTime DisplayString, trmAlarmActiveAcknowledge AlarmAcknowledge } trmAlarmActiveIndex OBJECT-TYPE SYNTAX INTEGER (1 .. 2147483647 ) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index for this alarm entry." ::= {trmAlarmActiveEntry 1 } trmAlarmActiveRackNumber OBJECT-TYPE SYNTAX RackNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The rack number where the alarm occured." ::= {trmAlarmActiveEntry 2 } trmAlarmActiveSlotNumber OBJECT-TYPE SYNTAX SlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The slot number where the alarm occured." ::= {trmAlarmActiveEntry 3 } trmAlarmActiveName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm description" ::= {trmAlarmActiveEntry 4 } trmAlarmActiveSeverity OBJECT-TYPE SYNTAX PerceivedSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm severity. Can be indeterminate (0) , critical (1) , major (2) , minor (3) or warning (4)." ::= {trmAlarmActiveEntry 5 } trmAlarmActiveUnit OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The type, version and index of the unit associated with the alarm." ::= {trmAlarmActiveEntry 6 } trmAlarmActiveSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number of the unit associated with the alarm." ::= {trmAlarmActiveEntry 7 } trmAlarmActiveActTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The time the alarm was generated." ::= {trmAlarmActiveEntry 8 } trmAlarmActiveDeactTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The time the alarm was deactivated." ::= {trmAlarmActiveEntry 9 } trmAlarmActiveAcknowledge OBJECT-TYPE SYNTAX AlarmAcknowledge MAX-ACCESS read-write STATUS current DESCRIPTION "This oid is used to acknowledge a alarm. To acknowledge a alarm, a SetRequest-PDU with a acknowledge(1) value encoding is used." ::= {trmAlarmActiveEntry 10 } --***************************************************************************************** --***************************************************************************************** -- trmSubracks --***************************************************************************************** --***************************************************************************************** trmSubrack OBJECT IDENTIFIER ::= {system1100 2 } --***************************************************************************************** --***************************************************************************************** -- trmSubrackList --***************************************************************************************** --***************************************************************************************** trmSubrackList OBJECT IDENTIFIER ::= {trmSubrack 1 } trmSubrackListTable OBJECT-TYPE SYNTAX SEQUENCE OF TrmSubrackListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of units present in the subrack(s)." ::= {trmSubrackList 1} trmSubrackListEntry OBJECT-TYPE SYNTAX TrmSubrackListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of parameters that describe a unit." INDEX {trmListRackNumber,trmListSlotNumber } ::= {trmSubrackListTable 1} TrmSubrackListEntry ::= SEQUENCE { trmListRackNumber RackNumber, trmListSlotNumber SlotNumber, trmListUnitPresent Present, trmListProductNumber DisplayString, trmListProductDescription DisplayString, trmListHwRevision DisplayString, trmListSerialNumber DisplayString, trmListManufacturingDate DisplayString, trmListSoftwareProdNo DisplayString, trmListSwVersion DisplayString } trmListRackNumber OBJECT-TYPE SYNTAX RackNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates in what rack the unit is situated in." ::= {trmSubrackListEntry 1 } trmListSlotNumber OBJECT-TYPE SYNTAX SlotNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates in what slot the unit is situated in. Can be slot 1-12." ::= {trmSubrackListEntry 2 } trmListUnitPresent OBJECT-TYPE SYNTAX Present MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates if the unit is present yes(1) or not no(2)." ::= {trmSubrackListEntry 3 } trmListProductNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Product number of the unit (XXYY/ZZ) where: Board type = XX Board version = YY Board index = ZZ." ::= {trmSubrackListEntry 4 } trmListProductDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A product description of the unit." ::= {trmSubrackListEntry 5 } trmListHwRevision OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The hardware revision of the unit." ::= {trmSubrackListEntry 6 } trmListSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number of the unit." ::= {trmSubrackListEntry 7} trmListManufacturingDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The manufacturing date of the unit. Format is Year:Week." ::= {trmSubrackListEntry 8} trmListSoftwareProdNo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The software product number of the software on this unit." ::= {trmSubrackListEntry 9} trmListSwVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Revision number of the software on this unit." ::= {trmSubrackListEntry 10} --***************************************************************************************** --***************************************************************************************** -- Units --***************************************************************************************** --***************************************************************************************** trmSubrackUnits OBJECT IDENTIFIER ::= {trmSubrack 2 } --***************************************************************************************** --***************************************************************************************** -- NMB - Network management board --***************************************************************************************** --***************************************************************************************** trm6001 OBJECT IDENTIFIER ::= {trmSubrackUnits 1 } --***************************************************************************************** -- NMB - Performance management --***************************************************************************************** trm6001PM OBJECT IDENTIFIER ::= {trm6001 1 } trm6001Table OBJECT-TYPE SYNTAX SEQUENCE OF Trm6001Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of NMB(s)." ::= {trm6001PM 1} trm6001Entry OBJECT-TYPE SYNTAX Trm6001Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of parameters that describes an NMB" INDEX {trm6001RackNumber,trm6001SlotNumber} ::= {trm6001Table 1} Trm6001Entry ::= SEQUENCE { trm6001RackNumber RackNumber, trm6001SlotNumber SlotNumberNmb, trm6001IPAddress DisplayString, trm6001MACAddress DisplayString, trm6001Temperature INTEGER, trm6001UpTime DisplayString, trm6001Date TrmDate, trm6001Time TrmTime, trm6001SwReset INTEGER } trm6001RackNumber OBJECT-TYPE SYNTAX RackNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "The network management board rack number." ::= {trm6001Entry 1 } trm6001SlotNumber OBJECT-TYPE SYNTAX SlotNumberNmb MAX-ACCESS not-accessible STATUS current DESCRIPTION "The network management board slot number." ::= {trm6001Entry 2 } trm6001IPAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The network management board IP address." ::= {trm6001Entry 3 } trm6001MACAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The network management board MAC address." ::= {trm6001Entry 4 } trm6001Temperature OBJECT-TYPE SYNTAX INTEGER (1 .. 2147483647 ) MAX-ACCESS read-only STATUS current DESCRIPTION "The network management board temperature in deg. C or deg. F. See trmTemperature if deg. Celsius or Farenheit is used." ::= {trm6001Entry 5 } trm6001UpTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The network management board up time." ::= {trm6001Entry 6 } trm6001Date OBJECT-TYPE SYNTAX TrmDate MAX-ACCESS read-write STATUS current DESCRIPTION "Used to set the NMB date on format YYYY-MM-DD." ::= {trm6001Entry 7 } trm6001Time OBJECT-TYPE SYNTAX TrmTime MAX-ACCESS read-write STATUS current DESCRIPTION "Used to set the NMB time on format HH:MM:SS." ::= {trm6001Entry 8 } trm6001SwReset OBJECT-TYPE SYNTAX INTEGER { reset(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to reset the NMB unit. To reset the NMB unit, a SetRequest-PDU with a reset(1) value encoding is used." ::= {trm6001Entry 9 } --***************************************************************************************** -- NMB - fault management --***************************************************************************************** trm6001FM OBJECT IDENTIFIER ::= {trm6001 2 } trm6001Traps OBJECT IDENTIFIER ::= { trm6001FM 0 } trm6001TrapExternal1 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a External 1 alarm is generated at the NMB 6001 unit." ::= { trm6001Traps 1 } trm6001TrapExternal2 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a External 2 alarm is generated at the NMB 6001 unit." ::= { trm6001Traps 2 } trm6001TrapExternal3 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a External 3 alarm is generated at the NMB 6001 unit." ::= { trm6001Traps 3 } trm6001CascadeFailure NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a attempt to enable Cascading has failed or connection is lost with the cascading rack." ::= { trm6001Traps 4 } --***************************************************************************************** --***************************************************************************************** -- Power --***************************************************************************************** --***************************************************************************************** trm9xxx OBJECT IDENTIFIER ::= { trmSubrackUnits 2 } --***************************************************************************************** -- Power - performance management --***************************************************************************************** trm9xxxPM OBJECT IDENTIFIER ::= {trm9xxx 1 } trm9xxxTable OBJECT-TYPE SYNTAX SEQUENCE OF Trm9xxxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of power supply units in the subrack(s)." ::= {trm9xxxPM 1} trm9xxxEntry OBJECT-TYPE SYNTAX Trm9xxxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of parameters that describe a power supply unit." INDEX {trm9xxxRackNumber,trm9xxxSlotNumber} ::= {trm9xxxTable 1} Trm9xxxEntry ::= SEQUENCE { trm9xxxRackNumber RackNumber, trm9xxxSlotNumber SlotNumberPS, trm9xxxPresent Present, trm9xxxType PowerType, trm9xxxStatus PowerStatus } trm9xxxRackNumber OBJECT-TYPE SYNTAX RackNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates in what rack the power supply is situated in." ::= {trm9xxxEntry 1 } trm9xxxSlotNumber OBJECT-TYPE SYNTAX SlotNumberPS MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates in what slot number the power supply is situated in. Can be slot 10 or 11." ::= {trm9xxxEntry 2 } trm9xxxPresent OBJECT-TYPE SYNTAX Present MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates if the power supply is present or not. yes(1) means present and no(2) means not present." ::= {trm9xxxEntry 3 } trm9xxxType OBJECT-TYPE SYNTAX PowerType MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter describes what kind of power supply this unit is. Power9048(2) means a power supply with input pover 48 VDC, Power9220(3) means 100-240 VAC. If the type is unknown this parameter is unknown(1)." ::= {trm9xxxEntry 4 } trm9xxxStatus OBJECT-TYPE SYNTAX PowerStatus MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the power supply. off(1) means that the power supply not is operating and on(2) means that it is operating." ::= {trm9xxxEntry 5 } --***************************************************************************************** -- Power - fault management --***************************************************************************************** trm9xxxFM OBJECT IDENTIFIER ::= {trm9xxx 2 } trm9xxxTraps OBJECT IDENTIFIER ::= { trm9xxxFM 0 } trm9xxxTrapFailure NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap indicates that a fault was detected on a power supply or the input power is removed." ::= { trm9xxxTraps 1 } trm9xxxTrapMissing NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a power supply is missing." ::= { trm9xxxTraps 2 } --***************************************************************************************** --***************************************************************************************** -- 70YY/ZZ and 75YY/ZZ Interface slots --***************************************************************************************** --***************************************************************************************** trm75xx OBJECT IDENTIFIER ::= {trmSubrackUnits 3 } --***************************************************************************************** -- 70YY/ZZ and 75YY/ZZ Interface units Performance management --***************************************************************************************** trm75xxPM OBJECT IDENTIFIER ::= {trm75xx 1 } trm75xxTable OBJECT-TYPE SYNTAX SEQUENCE OF Trm75xxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of 70 & 75 units in the subrack(s)." ::= {trm75xxPM 1} trm75xxEntry OBJECT-TYPE SYNTAX Trm75xxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of parameters that describe a 70 or a 75 unit." INDEX {trm75xxRackNumber,trm75xxSlotNumber} ::= {trm75xxTable 1} Trm75xxEntry ::= SEQUENCE { trm75xxRackNumber RackNumber, trm75xxSlotNumber BoardNumber, trm75xxRxLine DisplayString, trm75xxEstProtLine DisplayString, trm75xxEstFibRateLine DisplayString, trm75xxTxLine DisplayString, trm75xxTxMode TxMode75, trm75xxWavelengthLine DisplayString, trm75xxRxClient DisplayString, trm75xxEstProtClient DisplayString, trm75xxEstFibRateClient DisplayString, trm75xxTxClient DisplayString, trm75xxTxModeClient TxMode75, trm75xxIDStringClient DisplayString, trm75xxIPAddressClient DisplayString, trm75xxWavelengthClient DisplayString, trm75xxSpeedLimit SpeedLimit75 } trm75xxRackNumber OBJECT-TYPE SYNTAX RackNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameter indicates in what rack the unit is situated in." ::= {trm75xxEntry 1} trm75xxSlotNumber OBJECT-TYPE SYNTAX BoardNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameter indicates in what slot number the unit is situated in. Can be slot 1 - 8." ::= {trm75xxEntry 2} trm75xxRxLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical input for the line interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving." ::= {trm75xxEntry 3} trm75xxEstProtLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the Estimated Protocol for the line interface input." ::= {trm75xxEntry 4} trm75xxEstFibRateLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the Estimated Fiber Rate for the line interface input in Mbit/s." ::= {trm75xxEntry 5} trm75xxTxLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical output power for the line interface. It corresponds to the line Tx LED status of the unit. Can be on or off." ::= {trm75xxEntry 6} trm75xxTxMode OBJECT-TYPE SYNTAX TxMode75 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1) or disabled(2). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF." ::= {trm75xxEntry 7} trm75xxWavelengthLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the nominal wavelength for the line interface transiever." ::= {trm75xxEntry 8} trm75xxRxClient OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical input for the client interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving." ::= {trm75xxEntry 9} trm75xxEstProtClient OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the Estimated Protocol for the client interface input." ::= {trm75xxEntry 10} trm75xxEstFibRateClient OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the Estimated Fiber Rate for the client interface input in Mbit/s." ::= {trm75xxEntry 11} trm75xxTxClient OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical output power for the client interface. It corresponds to the client Tx LED status of the unit. Can be on or off." ::= {trm75xxEntry 12} trm75xxTxModeClient OBJECT-TYPE SYNTAX TxMode75 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "This object is obsolete and not used anymore." ::= {trm75xxEntry 13} trm75xxIDStringClient OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter identifies the equipment(ID String) connected to the client interface. Maximum number of characters is 20." ::= {trm75xxEntry 14 } trm75xxIPAddressClient OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indentifies the equipment(IP Address) connected to the client interface." ::= {trm75xxEntry 15 } trm75xxWavelengthClient OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the nominal wavelength for the client interface transiever." ::= {trm75xxEntry 16} trm75xxSpeedLimit OBJECT-TYPE SYNTAX SpeedLimit75 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the speed limit set for this unit and is used to set a new speed limit. It generates an alarm and disables Line and Client Tx if the Client bitrate is higher than a predefined protocol. The alarm is ceased and Tx is enabled again at a lower value (hysteresis). Speed Limit is deactivated if trm75xxTxMode is disabled(2). Speed Limit can be set in 3 modes to allow different protocols: noLimit(1): Any protocol is allowed. lowLimit(2): 100Base-FX, STM1/OC3, ESCON & Video 270Mb. mediumLimit(3): All protocols above + STM4/OC-12." ::= {trm75xxEntry 17} --***************************************************************************************** -- 70YY/ZZ and 75YY/ZZ Interface units fault management --***************************************************************************************** trm75xxFM OBJECT IDENTIFIER ::= {trm75xx 2 } trm75xxTraps OBJECT IDENTIFIER ::= { trm75xxFM 0 } trm75xxTrapGlitchLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit experiences a split second optical input power glitch at the line interface." ::= { trm75xxTraps 1 } trm75xxTrapLopLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the optical input power is lost at the line interface." ::= { trm75xxTraps 2 } trm75xxTrapTxLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit fails to generate optical output power at Tx line interface." ::= { trm75xxTraps 3 } trm75xxTrapTxDisableLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the optical output power for the line interface is disabled." ::= { trm75xxTraps 4 } trm75xxTrapGlitchClient NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit experiences a split second optical input power glitch at the client interface." ::= { trm75xxTraps 5 } trm75xxTrapLopClient NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the optical input power is lost at the client interface." ::= { trm75xxTraps 6 } trm75xxTrapTxClient NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit fails to generate optical output power at Tx client." ::= { trm75xxTraps 7 } trm75xxTrapTxDisableClient NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the optical output power for the client interface is disabled." ::= { trm75xxTraps 8 } --***************************************************************************************** --***************************************************************************************** -- 76YY/ZZ Interface units --***************************************************************************************** --***************************************************************************************** trm76xx OBJECT IDENTIFIER ::= {trmSubrackUnits 4 } --***************************************************************************************** -- 76YY/ZZ Interface units performance management --***************************************************************************************** trm76xxPM OBJECT IDENTIFIER ::= {trm76xx 1 } trm76xxTable OBJECT-TYPE SYNTAX SEQUENCE OF Trm76xxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of 76YY/ZZ in the subrack(s)." ::= {trm76xxPM 1} trm76xxEntry OBJECT-TYPE SYNTAX Trm76xxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of parameters that describe the Subrack units" INDEX {trm76xxRackNumber,trm76xxSlotNumber } ::= {trm76xxTable 1} Trm76xxEntry ::= SEQUENCE { trm76xxRackNumber RackNumber, trm76xxSlotNumber BoardNumber, trm76xxTemperature INTEGER, trm76xxCDR CDRMode, trm76xxCustomFibRate INTEGER, trm76xxTxMode TxMode76, trm76xxLineLoopMode LineLoopMode, trm76xxSwReset INTEGER, trm76xxRxLine DisplayString, trm76xxOpticalInPowLine INTEGER, trm76xxSpeedLimit SpeedLimit76, trm76xxEstProtLine DisplayString, trm76xxEstFibRateLine DisplayString, trm76xxTxLine DisplayString, trm76xxOpticalOutPowLine INTEGER, trm76xxProdOutPowLine INTEGER, trm76xxLaserBiasCurLine INTEGER, trm76xxProdLaserBiasCurLine INTEGER, trm76xxWavelengthLine DisplayString, trm76xxRxClient DisplayString, trm76xxEstProtClient DisplayString, trm76xxEstFibRateClient DisplayString, trm76xxTxClient DisplayString, trm76xxIDStringClient DisplayString, trm76xxIPAddressClient DisplayString, trm76xxWavelengthClient DisplayString, trm76xxOpticalInPowClient INTEGER, trm76xxOpticalOutPowClient INTEGER, trm76xxLaserBiasCurClient INTEGER } trm76xxRackNumber OBJECT-TYPE SYNTAX RackNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameter indicates in what rack the unit is situated in." ::= {trm76xxEntry 1} trm76xxSlotNumber OBJECT-TYPE SYNTAX BoardNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameter indicates in what slot number the unit is situated in. Can be any of slot 1 - 8." ::= {trm76xxEntry 2} trm76xxTemperature OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the temperature measured by the unit in deg. C or deg. F. See trmSubrackConfigTemp if deg. Celsius or Farenheit is used." ::= {trm76xxEntry 3} trm76xxCDR OBJECT-TYPE SYNTAX CDRMode MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the working mode of the CDR clock recovery circuit. Can be auto3R(1), bypass2R(2), custom(3),fddiOR100Base-FX(4), stm1orOC-3(5), video270Mbps(6), stm4orOC-12(7), gigabitEthernet(8), fibreChannel(9), fibreChannelx2(10), stm16orOC-48(11) or gigabitEthernetx2(12). custom(3) can not be set, it just indicates if a custom protocol is set with oid trm76xxCustomFibRate." ::= {trm76xxEntry 4} trm76xxCustomFibRate OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is used to set the working mode of the CDR clock recovery circuit(Custom mode). Custom mode can be set between 30000 and 2700000 Kbit/s." ::= {trm76xxEntry 5} trm76xxTxMode OBJECT-TYPE SYNTAX TxMode76 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. forcedon(3): Optical output is ON. (Normally, forcedon(3) is used for test purpose only)" ::= {trm76xxEntry 6} trm76xxLineLoopMode OBJECT-TYPE SYNTAX LineLoopMode MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is used to set the line loop mode. Can be set to normal(1) or looptest(2). normal(1): The line loop test function is off. looptest(2): Line is looped, RX=TX. (Normally, Loop test is only used for installation, test purpose or fault-location)." ::= {trm76xxEntry 7} trm76xxSwReset OBJECT-TYPE SYNTAX INTEGER { reset(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to reset the unit. To reset the unit, a SetRequest-PDU with a reset(1) value encoding is used." ::= {trm76xxEntry 8} trm76xxRxLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical input for the line interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving." ::= {trm76xxEntry 9} trm76xxOpticalInPowLine OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the Optical input power for the line interface. When the Optical input power is to low to measure this parameter is -500 (-50 dBm). If the Optical output power is to high to measure this parameter is -20 (-2 dBm). If this parameter is invalid -1 (-0.1 dBm) is returned. Divide this value by 10 to show optical input power in dBm." ::= {trm76xxEntry 10} trm76xxSpeedLimit OBJECT-TYPE SYNTAX SpeedLimit76 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the speed limit set for this unit and is used to set a new speed limit. It generates an alarm and disables Line and Client Tx if the Client bitrate is higher than a predefined protocol. The alarm is ceased and Tx is enabled again at a lower value (hysteresis). Speed Limit is deactivated if trm76xxTxMode is disabled(2) or forcedon(3). Speed Limit can be set in 4 modes to allow different protocols: noLimit(1): Any protocol is allowed. lowLimit(2): 100Base-FX, STM1/OC3, ESCON & Video 270Mb. mediumLimit(3): All protocols above + STM4/OC-12. highLimit(4): All protocols above + Fibre channel & Gigabit Ethernet." ::= {trm76xxEntry 11} trm76xxEstProtLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the Estimated Protocol for the line interface Rx." ::= {trm76xxEntry 12} trm76xxEstFibRateLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the Estimated Fiber Rate for the line interface Rx in Mbit/s." ::= {trm76xxEntry 13} trm76xxTxLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical output power for the line interface. It corresponds to the line Tx LED status of the unit. Can be on or off." ::= {trm76xxEntry 14} trm76xxOpticalOutPowLine OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the optical output power for the line interface. If data not is available yet this parameter is -1(-0.1 dBm). If this parameter is -100 (-10 dBm) the output power is equal too or less than -100 (-10 dBm). Divide this value by 10 to show the optical output power in dBm." ::= {trm76xxEntry 15} trm76xxProdOutPowLine OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the production output power for the line interface. If data not is valid yet this parameter is -1 (-0.1 dBm). Divide this value by 10 to show the production output power in dBm." ::= {trm76xxEntry 16} trm76xxLaserBiasCurLine OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the laser bias current for the line interface. If this parameter is 5450(545 mA) the laser bias current is more or equal to 545 mA. Divide this value by 10 to show the laser bias current in mA." ::= {trm76xxEntry 17} trm76xxProdLaserBiasCurLine OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the production laser bias current for the line interface. Divide this value by 10 to show the laser bias current in mA." ::= {trm76xxEntry 18} trm76xxWavelengthLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the nominal wavelength for the line interface transiever." ::= {trm76xxEntry 19} trm76xxRxClient OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical input for the client interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving." ::= {trm76xxEntry 20} trm76xxEstProtClient OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the Estimated Protocol for the client interface Rx." ::= {trm76xxEntry 21} trm76xxEstFibRateClient OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the Estimated Fiber Rate for the client interface Rx in Mbit/s." ::= {trm76xxEntry 22} trm76xxTxClient OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical output power for the client interface. It corresponds to the client Tx LED status of the unit. Can be on or off." ::= {trm76xxEntry 23} trm76xxIDStringClient OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter identifies the equipment(ID String) connected to the client interface. Maximum number of characters is 20." ::= {trm76xxEntry 24 } trm76xxIPAddressClient OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indentifies the equipment(IP Address) connected to the client interface." ::= {trm76xxEntry 25 } trm76xxWavelengthClient OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the nominal wavelength for the client interface transiever." ::= {trm76xxEntry 26} trm76xxOpticalInPowClient OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the Optical input power for the client interface. When the Optical input power is to low to measure this parameter is -500 (-50 dBm). If the Optical output power is to high to measure this parameter is -20 (-2 dBm). If this parameter is invalid -1 (-0.1 dBm) is returned. Divide this value by 10 to show optical input power in dBm." ::= {trm76xxEntry 27} trm76xxOpticalOutPowClient OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the optical output power for the client interface. If data not is available yet this parameter is -1(-0.1 dBm). If this parameter is -100 (-10 dBm) the output power is equal too or less than -100 (-10 dBm). Divide this value by 10 to show the optical output power in dBm." ::= {trm76xxEntry 28} trm76xxLaserBiasCurClient OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the laser bias current for the client interface. If this parameter is 5450(545 mA) the laser bias current is more or equal to 545 mA. Divide this value by 10 to show the laser bias current in mA." ::= {trm76xxEntry 29} --***************************************************************************************** -- 76YY/ZZ Subrack units fault management --***************************************************************************************** trm76xxFM OBJECT IDENTIFIER ::= {trm76xx 2 } trm76xxTraps OBJECT IDENTIFIER ::= { trm76xxFM 0 } trm76xxTrapCDRAutoModeRangeChangeLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a client equipment might be using a protocol not specified for auto mode or it might have changed the protocol. If auto mode is used consider goto manual mode instead. This trap concerns the regeneration at the Tx line output." ::= { trm76xxTraps 1 } trm76xxTrapRxGlitchLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit experiences a split second optical input power glitch at the line interface." ::= { trm76xxTraps 2 } trm76xxTrapLopLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the optical input power is lost at the line interface." ::= { trm76xxTraps 3 } trm76xxTrapRxHighPowerLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the optical input power for line is higher than trmOpticalInputPowerHighPINLine or trmOpticalInputPowerHighAPDLine." ::= { trm76xxTraps 4 } trm76xxTrapRxLowPowerLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the optical input power for line is lower than trmOpticalInputPowerLowPINLine or trmOpticalInputPowerLowAPDLine." ::= { trm76xxTraps 5 } trm76xxTrapLoLLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the line Tx indicates loss of 3R synchronization." ::= { trm76xxTraps 6 } trm76xxTrapTxLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit fails to generate optical output power at Tx line." ::= { trm76xxTraps 7 } trm76xxTrapSFPFailureLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS obsolete DESCRIPTION "This trap/alarm is not used in the system and is obsolete." ::= { trm76xxTraps 8 } trm76xxTrapSFPMissingLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS obsolete DESCRIPTION "This trap/alarm is not used in the system and is obsolete." ::= { trm76xxTraps 9 } trm76xxTrapCDRAutoModeRangeChangeClient NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a client equipment might be using a protocol not specified for auto mode or it might have changed the protocol. If auto mode is used consider goto manual mode instead. This trap concerns the regeneration at the Tx client output." ::= { trm76xxTraps 10 } trm76xxTrapRxGlitchClient NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit experiences a split second optical input power glitch at the client interface." ::= { trm76xxTraps 11 } trm76xxTrapLopClient NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the optical input power is lost at the client interface." ::= { trm76xxTraps 12 } trm76xxTrapRxHighPowerClient NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS obsolete DESCRIPTION "This trap/alarm is not used in the system and the object is obsolete." ::= { trm76xxTraps 13 } trm76xxTrapRxLowPowerClient NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS obsolete DESCRIPTION "This trap/alarm is not used in the system and the object is obsolete." ::= { trm76xxTraps 14 } trm76xxTrapLoLClient NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the client Tx indicates loss of 3R synchronization." ::= { trm76xxTraps 15 } trm76xxTrapTxClient NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit fails to generate optical output power at Tx client." ::= { trm76xxTraps 16 } trm76xxTrapSFPFailureClient NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit have a client SFP transiever got a failure or a Bias temperature alarm." ::= { trm76xxTraps 17 } trm76xxTrapSFPMissingClient NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit doesn't have a client SFP transiever." ::= { trm76xxTraps 18 } trm76xxTrapTxDisable NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the optical output power for both the line and client interface have been disabled." ::= { trm76xxTraps 19 } trm76xxTrapLaserDegradationLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when there is a laser degradation on the line laser. This means that the laser bias current is raised to be able to keep the optical output from the laser." ::= { trm76xxTraps 20 } trm76xxTrapEyeQualityLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "For future use." ::= { trm76xxTraps 21 } trm76xxTrapEyeQualityClient NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "For future use." ::= { trm76xxTraps 22 } --***************************************************************************************** --***************************************************************************************** -- Mux --***************************************************************************************** --***************************************************************************************** trm803x OBJECT IDENTIFIER ::= { trmSubrackUnits 5 } --***************************************************************************************** -- Mux - performance management --***************************************************************************************** trm803xPM OBJECT IDENTIFIER ::= {trm803x 1 } trm803xTable OBJECT-TYPE SYNTAX SEQUENCE OF Trm803xEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of 803x units." ::= {trm803xPM 1} trm803xEntry OBJECT-TYPE SYNTAX Trm803xEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of parameters that describe a 803x unit." INDEX {trm803xRackNumber,trm803xSlotNumber} ::= {trm803xTable 1} Trm803xEntry ::= SEQUENCE { trm803xRackNumber RackNumber, trm803xSlotNumber INTEGER, trm803xMuxType MuxType, trm803xIDStringLine DisplayString, trm803xIPAddressLine DisplayString } trm803xRackNumber OBJECT-TYPE SYNTAX RackNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates in what rack the 803x unit is situated in." ::= {trm803xEntry 1 } trm803xSlotNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates in what slot number the 803x unitis situated in. Can only be slot 12." ::= {trm803xEntry 2 } trm803xMuxType OBJECT-TYPE SYNTAX MuxType MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates what Mux type this is. Can be none(1), mux8030(2), mux8031(3), mux8032(4), mux8033(5) or mux8034(6)." ::= {trm803xEntry 3 } trm803xIDStringLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter identifies the equipment connected to the line interface. The ID string can be used to indentify a fiber pair/link. Maximum number of characters is 20." ::= {trm803xEntry 4 } trm803xIPAddressLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter identifies the equipment connected to the line interface. The IP address can be used to indentify the corresponding NMB unit." ::= {trm803xEntry 5 } --***************************************************************************************** --***************************************************************************************** -- 2204 --***************************************************************************************** --***************************************************************************************** trm2204 OBJECT IDENTIFIER ::= { trmSubrackUnits 6 } --***************************************************************************************** -- Mux - performance management --***************************************************************************************** trm2204PM OBJECT IDENTIFIER ::= {trm2204 1 } trm2204Table OBJECT-TYPE SYNTAX SEQUENCE OF Trm2204Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of 2204 units." ::= {trm2204PM 1} trm2204Entry OBJECT-TYPE SYNTAX Trm2204Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of parameters that describe a 2204 unit." INDEX {trm2204RackNumber,trm2204SlotNumber} ::= {trm2204Table 1} Trm2204Entry ::= SEQUENCE { trm2204RackNumber RackNumber, trm2204SlotNumber INTEGER, trm2204SecurityMode SecurityMode } trm2204RackNumber OBJECT-TYPE SYNTAX RackNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates in what rack the 2204 unit is situated in." ::= {trm2204Entry 1 } trm2204SlotNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates in what slot number the 2204 unitis situated in. Can be slot 1-8." ::= {trm2204Entry 2 } trm2204SecurityMode OBJECT-TYPE SYNTAX SecurityMode MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the security mode for the unit. It is also used to set the Security Mode for the unit. Can be activated(1) or deactivated(2)." ::= {trm2204Entry 3 } --***************************************************************************************** --***************************************************************************************** -- 26xx Interface slots --***************************************************************************************** --***************************************************************************************** trm26xx OBJECT IDENTIFIER ::= {trmSubrackUnits 7 } --***************************************************************************************** -- 26xx Interface units Performance management --***************************************************************************************** trm26xxPM OBJECT IDENTIFIER ::= {trm26xx 1 } trm26xxTable OBJECT-TYPE SYNTAX SEQUENCE OF Trm26xxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of 26xx units in the subrack(s)." ::= {trm26xxPM 1} trm26xxEntry OBJECT-TYPE SYNTAX Trm26xxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of parameters that describe a 26xx unit." INDEX {trm26xxRackNumber,trm26xxSlotNumber} ::= {trm26xxTable 1} Trm26xxEntry ::= SEQUENCE { trm26xxRackNumber RackNumber, trm26xxSlotNumber BoardNumber, trm26xxStatus DisplayString, trm26xxTemperature INTEGER, trm26xxTxMode TxMode75, trm26xxSwReset INTEGER, trm26xxOpticalPowerPIN1 INTEGER, trm26xxOpticalPowerPIN2 INTEGER, trm26xxLogOpticalPower INTEGER, trm26xxTemperatureTEC1 INTEGER, trm26xxTemperatureTEC2 INTEGER, trm26xxVoltageTEC1 INTEGER, trm26xxVoltageTEC2 INTEGER, trm26xxCurrentTEC1 INTEGER, trm26xxCurrentTEC2 INTEGER, trm26xxCurrentBIAS1 INTEGER, trm26xxCurrentBIAS2 INTEGER, trm26xxVoltageBIAS1 INTEGER, trm26xxVoltageBIAS2 INTEGER } trm26xxRackNumber OBJECT-TYPE SYNTAX RackNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameter indicates in what rack the unit is situated in." ::= {trm26xxEntry 1} trm26xxSlotNumber OBJECT-TYPE SYNTAX BoardNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameter indicates in what slot number the unit is situated in. Can be slot 1 - 8." ::= {trm26xxEntry 2} trm26xxStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical input for the line interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving." ::= {trm26xxEntry 3} trm26xxTemperature OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The network management board temperature in deg. C or deg. F. See trmTemperature if deg. Celsius or Farenheit is used." ::= {trm26xxEntry 4} trm26xxTxMode OBJECT-TYPE SYNTAX TxMode75 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1) or disabled(2). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF." ::= {trm26xxEntry 5} trm26xxSwReset OBJECT-TYPE SYNTAX INTEGER { reset(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to reset the unit. To reset the unit, a SetRequest-PDU with a reset(1) value encoding is used." ::= {trm26xxEntry 6} trm26xxOpticalPowerPIN1 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {trm26xxEntry 7} trm26xxOpticalPowerPIN2 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {trm26xxEntry 8} trm26xxLogOpticalPower OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {trm26xxEntry 9} trm26xxTemperatureTEC1 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {trm26xxEntry 10} trm26xxTemperatureTEC2 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {trm26xxEntry 11} trm26xxVoltageTEC1 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {trm26xxEntry 12} trm26xxVoltageTEC2 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= {trm26xxEntry 13} trm26xxCurrentTEC1 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {trm26xxEntry 14 } trm26xxCurrentTEC2 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {trm26xxEntry 15 } trm26xxCurrentBIAS1 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {trm26xxEntry 16} trm26xxCurrentBIAS2 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {trm26xxEntry 17} trm26xxVoltageBIAS1 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {trm26xxEntry 18} trm26xxVoltageBIAS2 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {trm26xxEntry 19} --***************************************************************************************** -- 26xx Interface units fault management --***************************************************************************************** trm26xxFM OBJECT IDENTIFIER ::= {trm26xx 2 } trm26xxTraps OBJECT IDENTIFIER ::= { trm26xxFM 0 } trm26xxTrapTEC1Faulty NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "" ::= { trm26xxTraps 1 } trm26xxTrapTEC2Faulty NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "" ::= { trm26xxTraps 2 } trm26xxTrapBIAS1Faulty NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "" ::= { trm26xxTraps 3 } trm26xxTrapBIAS2Faulty NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "" ::= { trm26xxTraps 4 } trm26xxTrapPIUTempShutdown NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "" ::= { trm26xxTraps 5 } trm26xxTrapOpticalLinkdown NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "" ::= { trm26xxTraps 6 } trm26xxTrapTxDisable NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the amplifier has been disabled." ::= { trm26xxTraps 7 } --***************************************************************************************** --***************************************************************************************** -- 25xx Interface units --***************************************************************************************** --***************************************************************************************** trm25xx OBJECT IDENTIFIER ::= {trmSubrackUnits 8 } --***************************************************************************************** -- 25YY/ZZ Interface units performance management --***************************************************************************************** trm25xxPM OBJECT IDENTIFIER ::= {trm25xx 1 } trm25xxTable OBJECT-TYPE SYNTAX SEQUENCE OF Trm25xxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of 25xx in the subrack(s)." ::= {trm25xxPM 1} trm25xxEntry OBJECT-TYPE SYNTAX Trm25xxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of parameters that describe the Subrack units" INDEX {trm25xxRackNumber,trm25xxSlotNumber } ::= {trm25xxTable 1} Trm25xxEntry ::= SEQUENCE { trm25xxRackNumber RackNumber, trm25xxSlotNumber BoardNumber, trm25xxWorkingLineStatus DisplayString, trm25xxProtectingLineStatus DisplayString, trm25xxTemperature INTEGER, trm25xxSwReset INTEGER, trm25xxRxLine DisplayString, trm25xxOpticalInPowLine INTEGER, trm25xxSpeedLimit SpeedLimit76, trm25xxEstProtLine DisplayString, trm25xxEstFibRateLine DisplayString, trm25xxTxLine DisplayString, trm25xxOpticalOutPowLine INTEGER, trm25xxProdOutPowLine INTEGER, trm25xxLaserBiasCurLine INTEGER, trm25xxProdLaserBiasCurLine INTEGER, trm25xxCDR CDRMode, trm25xxCustomFibRate INTEGER, trm25xxTxMode TxMode76 } trm25xxRackNumber OBJECT-TYPE SYNTAX RackNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameter indicates in what rack the unit is situated in." ::= {trm25xxEntry 1} trm25xxSlotNumber OBJECT-TYPE SYNTAX BoardNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameter indicates in what slot number the unit is situated in. Can be any of slot 1 - 8." ::= {trm25xxEntry 2} trm25xxWorkingLineStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the Working Line status." ::= {trm25xxEntry 3 } trm25xxProtectingLineStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the Protecting Line status." ::= {trm25xxEntry 4 } trm25xxTemperature OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the temperature measured by the unit in deg. C or deg. F. See trmSubrackConfigTemp if deg. Celsius or Farenheit is used." ::= {trm25xxEntry 5} trm25xxSwReset OBJECT-TYPE SYNTAX INTEGER { reset(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to reset the unit. To reset the unit, a SetRequest-PDU with a reset(1) value encoding is used." ::= {trm25xxEntry 6} trm25xxRxLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical input for the line Subrack. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving." ::= {trm25xxEntry 7} trm25xxOpticalInPowLine OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the Optical input power for the line Subrack. When the Optical input power is to low to measure this parameter is -500 (-50 dBm). If the Optical output power is to high to measure this parameter is -20 (-2 dBm). If this parameter is invalid -1 (-0.1 dBm) is returned. Divide this value by 10 to show optical input power in dBm." ::= {trm25xxEntry 8 } trm25xxSpeedLimit OBJECT-TYPE SYNTAX SpeedLimit76 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the speed limit set for this unit and is used to set a new speed limit. It generates an alarm and disables Line and Client Tx if the Client bitrate is higher than a predefined protocol. The alarm is ceased and Tx is enabled again at a lower value (hysteresis). Speed Limit is deactivated if trm25xxTxMode is disabled(2) or forcedon(3). Speed Limit can be set in 4 modes to allow different protocols: noLimit(1): Any protocol is allowed. lowLimit(2): 100Base-FX, STM1/OC3, ESCON & Video 270Mb. mediumLimit(3): All protocols above + STM4/OC-12. highLimit(4): All protocols above + Fibre channel & Gigabit Ethernet." ::= {trm25xxEntry 9} trm25xxEstProtLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the Estimated Protocol for the line Subrack input." ::= {trm25xxEntry 10} trm25xxEstFibRateLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the Estimated Fiber Rate for the line Subrack input in Mbit/s." ::= {trm25xxEntry 11} trm25xxTxLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical output power for the line Subrack. It corresponds to the line Tx LED status of the unit. Can be on or off." ::= {trm25xxEntry 12} trm25xxOpticalOutPowLine OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the optical output power for the line Subrack. If data not is available yet this parameter is -1(-0.1 dBm). If this parameter is -100 (-10 dBm) the output power is equal too or less than -100 (-10 dBm). Divide this value by 10 to show the optical output power in dBm." ::= {trm25xxEntry 13} trm25xxProdOutPowLine OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the production output power for the line Subrack. If data not is valid yet this parameter is -1 (-0.1 dBm). Divide this value by 10 to show the production output power in dBm." ::= {trm25xxEntry 14} trm25xxLaserBiasCurLine OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the laser bias current for the line Subrack. If this parameter is 5450(545 mA) the laser bias current is more or equal to 545 mA. Divide this value by 10 to show the laser bias current in mA." ::= {trm25xxEntry 15} trm25xxProdLaserBiasCurLine OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the production laser bias current for the line Subrack. Divide this value by 10 to show the laser bias current in mA." ::= {trm25xxEntry 16} trm25xxCDR OBJECT-TYPE SYNTAX CDRMode MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the working mode of the CDR clock recovery circuit. Can be auto3R(1), bypass2R(2), custom(3),fddiOR100Base-FX(4), stm1orOC-3(5), video270Mbps(6), stm4orOC-12(7), gigabitEthernet(8), fibreChannel(9), fibreChannelx2(10), stm16orOC-48(11) or gigabitEthernetx2(12). custom(3) can not be set, it just indicates if a custom protocol is set with oid trm25xxCustomFibRate." ::= {trm25xxEntry 17} trm25xxCustomFibRate OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is used to set the working mode of the CDR clock recovery circuit(Custom mode). Custom mode can be set between 30000 and 2700000 Kbit/s." ::= {trm25xxEntry 18} trm25xxTxMode OBJECT-TYPE SYNTAX TxMode76 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. forcedon(3): Optical output is ON. (Normally, forcedon(3) is used for test purpose only)" ::= {trm25xxEntry 19} --***************************************************************************************** -- 25xx Subrack units fault management --***************************************************************************************** trm25xxFM OBJECT IDENTIFIER ::= {trm25xx 2 } trm25xxTraps OBJECT IDENTIFIER ::= { trm25xxFM 0 } trm25xxTrapWorkingLineFailure NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Working Line goes down." ::= { trm25xxTraps 1 } trm25xxTrapProtectingLineFailure NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Protecting Line goes down." ::= { trm25xxTraps 2 } trm25xxTrapWorkingAndProtectingLineFailure NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when both the Working and Protecting Line goes down." ::= { trm25xxTraps 3 } --***************************************************************************************** --***************************************************************************************** -- 5300/01 and 5500/01 Interface units --***************************************************************************************** --***************************************************************************************** trm53005500 OBJECT IDENTIFIER ::= {trmSubrackUnits 9 } --***************************************************************************************** -- 5300/01 and 5500/01 Interface units performance management --***************************************************************************************** trm53005500PM OBJECT IDENTIFIER ::= {trm53005500 1 } trm53005500Table OBJECT-TYPE SYNTAX SEQUENCE OF Trm53005500Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of all 5300/01 and 5500/01 units in the subrack(s)." ::= {trm53005500PM 1} trm53005500Entry OBJECT-TYPE SYNTAX Trm53005500Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of parameters that describe a 5300/01 or 5500/01 unit." INDEX {trm53005500RackNumber,trm53005500SlotNumber } ::= {trm53005500Table 1} Trm53005500Entry ::= SEQUENCE { trm53005500RackNumber RackNumber, trm53005500SlotNumber BoardNumber, trm53005500Temperature INTEGER, trm53005500SwReset INTEGER, trm53005500WavelengthLine DisplayString, trm53005500RxLine DisplayString, trm53005500OpticalInPowLine INTEGER, trm53005500TxLine DisplayString, trm53005500TxModeLine TxMode75, trm53005500WavelengthClient1 DisplayString, trm53005500RxClient1 DisplayString, trm53005500CDRClient1 CDR55Mode, trm53005500TxClient1 DisplayString, trm53005500TxModeClient1 TxMode76, trm53005500IDStringClient1 DisplayString, trm53005500IPAddressClient1 DisplayString, trm53005500WavelengthClient2 DisplayString, trm53005500RxClient2 DisplayString, trm53005500CDRClient2 CDR55Mode, trm53005500TxClient2 DisplayString, trm53005500TxModeClient2 TxMode76, trm53005500IDStringClient2 DisplayString, trm53005500IPAddressClient2 DisplayString, trm53005500WavelengthClient3 DisplayString, trm53005500RxClient3 DisplayString, trm53005500CDRClient3 CDR55Mode, trm53005500TxClient3 DisplayString, trm53005500TxModeClient3 TxMode76, trm53005500IDStringClient3 DisplayString, trm53005500IPAddressClient3 DisplayString, trm53005500WavelengthClient4 DisplayString, trm53005500RxClient4 DisplayString, trm53005500CDRClient4 CDR55Mode, trm53005500TxClient4 DisplayString, trm53005500TxModeClient4 TxMode76, trm53005500IDStringClient4 DisplayString, trm53005500IPAddressClient4 DisplayString } trm53005500RackNumber OBJECT-TYPE SYNTAX RackNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameter indicates in what rack the unit is situated in." ::= {trm53005500Entry 1} trm53005500SlotNumber OBJECT-TYPE SYNTAX BoardNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameter indicates in what slot number the unit is situated in. Can be any of slot 1 - 8." ::= {trm53005500Entry 2} trm53005500Temperature OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the temperature measured by the unit in deg. C or deg. F. See trmSubrackConfigTemp if deg. Celsius or Farenheit is used." ::= {trm53005500Entry 3} trm53005500SwReset OBJECT-TYPE SYNTAX INTEGER { reset(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to reset the unit. To reset the unit, a SetRequest-PDU with a reset(1) value encoding is used." ::= {trm53005500Entry 4} trm53005500WavelengthLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the nominal wavelength for the line interface transiever." ::= {trm53005500Entry 5} trm53005500RxLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical input for the line Subrack. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving." ::= {trm53005500Entry 6} trm53005500OpticalInPowLine OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the Optical input power for the line interface. When the Optical input power is to low to measure this parameter is -500 (-50 dBm). If the Optical output power is to high to measure this parameter is -20 (-2 dBm). If this parameter is invalid -1 (-0.1 dBm) is returned. Divide this value by 10 to show optical input power in dBm." ::= {trm53005500Entry 7} trm53005500TxLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical output power for the line Subrack. It corresponds to the line Tx LED status of the unit. Can be on or off." ::= {trm53005500Entry 8} trm53005500TxModeLine OBJECT-TYPE SYNTAX TxMode75 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the mode of the optical transmitter for line TX. Can be set to normal(1) or disabled(2). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF." ::= {trm53005500Entry 9} trm53005500WavelengthClient1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the nominal wavelength for the client 1 interface transiever." ::= {trm53005500Entry 10} trm53005500RxClient1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical input for the client 1 interface. It corresponds to the client 1 Rx LED status of the unit. Can be Receiving or Not receiving." ::= {trm53005500Entry 11} trm53005500CDRClient1 OBJECT-TYPE SYNTAX CDR55Mode MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the working mode of the CDR clock recovery circuit and is used to change working mode. Only setable for unit 5500/01. Can be ESCON(1), stm1orOC-3(2), fddiOR100Base-FX(3), or syncClock16MHz(4)." ::= {trm53005500Entry 12} trm53005500TxClient1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical output power. It corresponds to the Tx LED status of the unit. Can be on or off." ::= {trm53005500Entry 13} trm53005500TxModeClient1 OBJECT-TYPE SYNTAX TxMode76 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the mode of the optical transmitter for client 1 TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. forcedon(3): Optical output is ON. (Normally, forcedon(3) is used for test purpose only)" ::= {trm53005500Entry 14} trm53005500IDStringClient1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter identifies the equipment(ID String) connected to the client 1 interface. Maximum number of characters is 20." ::= {trm53005500Entry 15 } trm53005500IPAddressClient1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indentifies the equipment(IP Address) connected to the client 1 interface." ::= {trm53005500Entry 16 } trm53005500WavelengthClient2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the nominal wavelength for the client 2 interface transiever." ::= {trm53005500Entry 17} trm53005500RxClient2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical input for the client 2 interface. It corresponds to the client 2 Rx LED status of the unit. Can be Receiving or Not receiving." ::= {trm53005500Entry 18} trm53005500CDRClient2 OBJECT-TYPE SYNTAX CDR55Mode MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the working mode of the CDR clock recovery circuit and is used to change working mode. Only setable for unit 5500/01. Can be ESCON(1), stm1orOC-3(2), fddiOR100Base-FX(3), or syncClock16MHz(4)." ::= {trm53005500Entry 19} trm53005500TxClient2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical output power. It corresponds to the Tx LED status of the unit. Can be on or off." ::= {trm53005500Entry 20} trm53005500TxModeClient2 OBJECT-TYPE SYNTAX TxMode76 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the mode of the optical transmitter for client 2 TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. forcedon(3): Optical output is ON. (Normally, forcedon(3) is used for test purpose only)" ::= {trm53005500Entry 21} trm53005500IDStringClient2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter identifies the equipment(ID String) connected to the client 2 interface. Maximum number of characters is 20." ::= {trm53005500Entry 22 } trm53005500IPAddressClient2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indentifies the equipment(IP Address) connected to the client 2 interface." ::= {trm53005500Entry 23 } trm53005500WavelengthClient3 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the nominal wavelength for the client 3 interface transiever." ::= {trm53005500Entry 24} trm53005500RxClient3 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical input for the client 3 interface. It corresponds to the client 3 Rx LED status of the unit. Can be Receiving or Not receiving." ::= {trm53005500Entry 25} trm53005500CDRClient3 OBJECT-TYPE SYNTAX CDR55Mode MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the working mode of the CDR clock recovery circuit and is used to change working mode. Only setable for unit 5500/01. Can be ESCON(1), stm1orOC-3(2), fddiOR100Base-FX(3), or syncClock16MHz(4)." ::= {trm53005500Entry 26} trm53005500TxClient3 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical output power. It corresponds to the Tx LED status of the unit. Can be on or off." ::= {trm53005500Entry 27} trm53005500TxModeClient3 OBJECT-TYPE SYNTAX TxMode76 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the mode of the optical transmitter for client 3 TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. forcedon(3): Optical output is ON. (Normally, forcedon(3) is used for test purpose only)" ::= {trm53005500Entry 28} trm53005500IDStringClient3 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter identifies the equipment(ID String) connected to the client 3 interface. Maximum number of characters is 20." ::= {trm53005500Entry 29 } trm53005500IPAddressClient3 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indentifies the equipment(IP Address) connected to the client 3 interface." ::= {trm53005500Entry 30 } trm53005500WavelengthClient4 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the nominal wavelength for the client 4 interface transiever." ::= {trm53005500Entry 31} trm53005500RxClient4 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical input for the client 4 interface. It corresponds to the client 4 Rx LED status of the unit. Can be Receiving or Not receiving." ::= {trm53005500Entry 32} trm53005500CDRClient4 OBJECT-TYPE SYNTAX CDR55Mode MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the working mode of the CDR clock recovery circuit and is used to change working mode. Only setable for unit 5500/01. Can be ESCON(1), stm1orOC-3(2), fddiOR100Base-FX(3), or syncClock16MHz(4)." ::= {trm53005500Entry 33} trm53005500TxClient4 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates the status of the optical output power. It corresponds to the Tx LED status of the unit. Can be on or off." ::= {trm53005500Entry 34} trm53005500TxModeClient4 OBJECT-TYPE SYNTAX TxMode76 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the mode of the optical transmitter for client 4 TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. forcedon(3): Optical output is ON. (Normally, forcedon(3) is used for test purpose only)" ::= {trm53005500Entry 35} trm53005500IDStringClient4 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter identifies the equipment(ID String) connected to the client 4 interface. Maximum number of characters is 20." ::= {trm53005500Entry 36 } trm53005500IPAddressClient4 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indentifies the equipment(IP Address) connected to the client 4 interface." ::= {trm53005500Entry 37 } --***************************************************************************************** -- 5300/5500 Subrack units fault management --***************************************************************************************** trm53005500FM OBJECT IDENTIFIER ::= {trm53005500 2 } trm53005500Traps OBJECT IDENTIFIER ::= { trm53005500FM 0 } trm53005500TrapRxLinkdownLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Line Rx signal is out of sync or has been lost." ::= { trm53005500Traps 1 } trm53005500TrapExternalsyncFailureLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Line external sync signal is lost or is out of sync." ::= { trm53005500Traps 2 } trm53005500TrapSfpMissingLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Line SFP transiever not is mounted." ::= { trm53005500Traps 3 } trm53005500TrapSfpBadTypeLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a invalid Line SFP is used." ::= { trm53005500Traps 4 } trm53005500TrapSfpFaultyLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Line SFP is faulty." ::= { trm53005500Traps 5 } trm53005500TrapRxGlitchLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit experiences a split second optical input power glitch at the Line interface." ::= { trm53005500Traps 6 } trm53005500TrapTxGlitchLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit experiences a split second optical transmission glitch at the Line interface." ::= { trm53005500Traps 7 } trm53005500TrapTxDisabledLine NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the optical output power for the line interface have been disabled." ::= { trm53005500Traps 8 } trm53005500TrapRxLinkDownClient1 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Client 1 Rx signal is out of sync or has been lost." ::= { trm53005500Traps 9 } trm53005500TrapTxOutOfSyncClient1 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Client 1 tx output signal is outside the selected frequencey range." ::= { trm53005500Traps 10 } trm53005500TrapSfpMissingClient1 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Client 1 SFP transiever not is mounted." ::= { trm53005500Traps 11 } trm53005500TrapSfpBadTypeClient1 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unsupported Client 1 SFP is used." ::= { trm53005500Traps 12 } trm53005500TrapSfpFaultyClient1 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Client 1 SFP is faulty." ::= { trm53005500Traps 13 } trm53005500TrapTxGlitchClient1 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit experiences a split second optical transmission glitch at the Client 1 interface." ::= { trm53005500Traps 14 } trm53005500TrapRxGlitchClient1 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit experiences a split second optical input power glitch at the Client 1 interface." ::= { trm53005500Traps 15 } trm53005500TrapTxDisabledClient1 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the optical output power for the client 1 interface have been disabled." ::= { trm53005500Traps 16 } trm53005500TrapRxLinkDownClient2 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Client 2 Rx signal is out of sync or has been lost." ::= { trm53005500Traps 17 } trm53005500TrapTxOutOfSyncClient2 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Client 2 tx output signal is outside the selected frequencey range." ::= { trm53005500Traps 18 } trm53005500TrapSfpMissingClient2 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Client 2 SFP transiever not is mounted." ::= { trm53005500Traps 19 } trm53005500TrapSfpBadTypeClient2 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unsupported Client 2 SFP is used." ::= { trm53005500Traps 20 } trm53005500TrapSfpFaultyClient2 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Client 2 SFP is faulty." ::= { trm53005500Traps 21 } trm53005500TrapTxGlitchClient2 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit experiences a split second optical transmission glitch at the Client 2 interface." ::= { trm53005500Traps 22 } trm53005500TrapRxGlitchClient2 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit experiences a split second optical input power glitch at the Client 2 interface." ::= { trm53005500Traps 23 } trm53005500TrapTxDisabledClient2 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the optical output power for the client 2 interface have been disabled." ::= { trm53005500Traps 24 } trm53005500TrapRxLinkDownClient3 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Client 3 Rx signal is out of sync or has been lost." ::= { trm53005500Traps 25 } trm53005500TrapTxOutOfSyncClient3 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Client 3 tx output signal is outside the selected frequencey range." ::= { trm53005500Traps 26 } trm53005500TrapSfpMissingClient3 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Client 3 SFP transiever not is mounted." ::= { trm53005500Traps 27 } trm53005500TrapSfpBadTypeClient3 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unsupported Client 3 SFP is used." ::= { trm53005500Traps 28 } trm53005500TrapSfpFaultyClient3 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Client 3 SFP is faulty." ::= { trm53005500Traps 29 } trm53005500TrapTxGlitchClient3 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit experiences a split second optical transmission glitch at the Client 3 interface." ::= { trm53005500Traps 30 } trm53005500TrapRxGlitchClient3 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit experiences a split second optical input power glitch at the Client 3 interface." ::= { trm53005500Traps 31 } trm53005500TrapTxDisabledClient3 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the optical output power for the client 3 interface have been disabled." ::= { trm53005500Traps 32 } trm53005500TrapRxLinkDownClient4 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Client 4 Rx signal is out of sync or has been lost." ::= { trm53005500Traps 33 } trm53005500TrapTxOutOfSyncClient4 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Client 4 tx output signal is outside the selected frequencey range." ::= { trm53005500Traps 34 } trm53005500TrapSfpMissingClient4 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Client 4 SFP transiever not is mounted." ::= { trm53005500Traps 35 } trm53005500TrapSfpBadTypeClient4 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unsupported Client 4 SFP is used." ::= { trm53005500Traps 36 } trm53005500TrapSfpFaultyClient4 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the Client 4 SFP is faulty." ::= { trm53005500Traps 37 } trm53005500TrapTxGlitchClient4 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit experiences a split second optical transmission glitch at the Client 4 interface." ::= { trm53005500Traps 38 } trm53005500TrapRxGlitchClient4 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a unit experiences a split second optical input power glitch at the Client 4 interface." ::= { trm53005500Traps 39 } trm53005500TrapTxDisabledClient4 NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the optical output power for the client 4 interface have been disabled." ::= { trm53005500Traps 40 } trm53005500TrapHwFailure NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when the unit got a hardware failure." ::= { trm53005500Traps 41 } --***************************************************************************************** --***************************************************************************************** -- General Subrack fault management --***************************************************************************************** --***************************************************************************************** trmSubrackFM OBJECT IDENTIFIER ::= {trmSubrack 3 } trmSubrackTraps OBJECT IDENTIFIER ::= { trmSubrackFM 0 } trmTrapBmiLost NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when communication with a unit is lost." ::= { trmSubrackTraps 1 } trmTrapBmiError NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a internal BMI error occur." ::= { trmSubrackTraps 2 } trmTrapHighTemp NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a high temperature alarm occurs on the NMB 6001 unit or a unit with temperature measurement." ::= { trmSubrackTraps 3 } trmTrapLowTemp NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a low temperature alarm occurs on the NMB 6001 unit or a unit with temperature measurement." ::= { trmSubrackTraps 4 } trmTrapVeryHighTemp NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent when a very high temperature alarm occurs on the NMB 6001 unit or a unit with temperature measurement." ::= { trmSubrackTraps 5 } trmTrapSpeedLimitExceeded NOTIFICATION-TYPE OBJECTS { trmAlarmActiveName, trmAlarmActiveSeverity, trmAlarmActiveActTime, trmAlarmActiveUnit, trmAlarmActiveRackNumber, trmAlarmActiveSlotNumber, trmAlarmActiveSerialNumber } STATUS current DESCRIPTION "This trap is sent if the Client bitrate is higher than a predefined protocol. When the alarm is activated Line and Client Tx is disabled. The alarm is ceased and Tx is enabled again at a lower value (hysteresis). Speed Limit is deactivated if Tx mode for the unit is disabled(2) or forcedon(3)" ::= { trmSubrackTraps 6 } --***************************************************************************************** --***************************************************************************************** -- trmSubracks --***************************************************************************************** --***************************************************************************************** END