TIMETRA-PTP-MIB :: tmnxPtpClockRecoveryState

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › TIMETRA-PTP-MIB › tmnxPtpClockRecoveryState

tmnxPtpClockRecoveryState

Module: TIMETRA-PTP-MIB

OID (symbolic): TIMETRA-PTP-MIB::tmnxPtpClockRecoveryState

OID (numeric): 1.3.6.1.4.1.6527.3.1.2.74.3.1.1.9

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The value of tmnxPtpClockRecoveryState indicates the state of the clock recovery process on a PTP system. The various states are: notApplicable (0) - The system is not attempting to recover a clock initial (1) - The system is configured to recover a clock, but not enough information has yet been received to adjust the local clock to match a master clock acquiring (2) - The system has enough information to attempt clock recovery, and has started the process of adjusting its local clock frequency to match the master clock phaseTracking (3) - The system has adjusted its local clock to the approximate frequency of the master clock, and is adjusting the local clock to minimize the phase difference between the two clocks locked (4) - The system is locked to the chosen master clock and the phase error between the master clock and the local clock is relatively small holdover (5) - The system has stopped receiving useful information from the chosen master clock, and is maintaining the last estimated frequency for its local clock

What is tmnxPtpClockRecoveryState?

Shows where the clock-recovery state machine currently is -- initial, acquiring, phaseTracking, locked, or holdover -- which is the quickest way for an admin to judge whether PTP timing has actually converged.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6527.3.1.2.74.3.1.1.9
snmpwalk -v2c -c public <target> TIMETRA-PTP-MIB::tmnxPtpClockRecoveryState

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6527.3.1.2.74.3.1.1.9.1
snmpget -v2c -c public <target> TIMETRA-PTP-MIB::tmnxPtpClockRecoveryState.1

Start monitoring Alcatel-Lucent/Nokia SR OS service routers (7750/7450/7710 series) (PTP clock instance admin/oper status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-PTP-MIB::tmnxPtpClockRecoveryState OID value, configure state conditions and alerts, and monitor any Alcatel-Lucent/Nokia SR OS service routers (7750/7450/7710 series) (PTP clock instance admin/oper status) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6527timetraALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3timetraProductsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1tmnxSRMIBALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.2tmnxSRObjsALCATEL-IND1-TIMETRA-GLOBAL-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6527.3.1.2.74tmnxPtp1588ObjsTIMETRA-PTP-MIB
1.3.6.1.4.1.6527.3.1.2.74.3tmnxPtp1588StatusTIMETRA-PTP-MIB
1.3.6.1.4.1.6527.3.1.2.74.3.1tmnxPtpClockOperTableTIMETRA-PTP-MIB
1.3.6.1.4.1.6527.3.1.2.74.3.1.1tmnxPtpClockOperEntryTIMETRA-PTP-MIB
1.3.6.1.4.1.6527.3.1.2.74.3.1.1.9tmnxPtpClockRecoveryStateTIMETRA-PTP-MIB