All MIBs › TELDAT-TRAP-FR-MIB
Organization: Teldat, S.A.
Last Updated: 2014-01-20
Category: Remote Access and Serial WAN, Teldat Router Management, Teldat Trap Notifications
Description: Defines Teldat router FR (Frame Relay) interface event trap notifications.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is TELDAT-TRAP-FR-MIB?
TELDAT-TRAP-FR-MIB is a Teldat, S.A. enterprise MIB that defines SNMP notification objects for Frame Relay interface events on Teldat routers, registered under the shared telEventTraps subtree of TELDAT-MIB. It enumerates dozens of discrete FR events (frEventObjects1 through frEventObjects53), each an OBJECT-IDENTITY describing a specific occurrence — such as frame receipt/transmission, DLCI status changes, or LMI/signaling problems — paired with accessible-for-notify parameter objects (e.g. fr1-circuit, fr1-protocol, fr1-size, fr1-ifcname, fr1-buffer) that carry contextual detail like circuit number, protocol, frame size, and interface name inside the trap payload. Because these are notification-only objects rather than a polled table, the MIB is useful for event-driven monitoring: an NMS receiving these traps can log Frame Relay circuit-level anomalies in near real time rather than relying on periodic polling. It depends on TELDAT-MIB for its OID registration point and enterprise structure, and is deployed on Teldat router platforms carrying Frame Relay WAN circuits. Network teams managing Teldat FR links frequently need a TELDAT-TRAP-FR-MIB MIB Browser to decode the numbered event identities into meaningful circuit-level alerts.
IPNetwork Monitor allows you to monitor SNMP objects defined in TELDAT-TRAP-FR-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Teldat router platforms with Frame Relay WAN interfaces
Monitoring Examples
An operator configures an NMS trap receiver to capture notifications tied to frEventObjects1 (frame received) and later events in the series, inspecting the accompanying fr1-circuit and fr1-ifcname values to identify which Frame Relay circuit and interface triggered the event; a burst of error-type FR trap events referencing the same circuit number would indicate a failing or misconfigured Frame Relay PVC.
What Can Be Monitored
- Frame Relay interface event notifications
- per-event circuit/protocol/frame-size parameters
- interface name associated with FR events
- buffer-related event details
This MIB depends on
Related MIBs
Imported Objects
From SNMPv2-SMI
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-IDENTITY | |
| OBJECT-TYPE |
From SNMPv2-TC
| DisplayString |
From TELDAT-MIB
| telEventTraps | OBJECT-IDENTITY |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| frTrapsMIB | 1.3.6.1.4.1.2007.1.4.92 | This Module Information Base file is defined for managing received SNMP notifications generated by the FR event subsystem. | ||
| frEventsGroup | 1.3.6.1.4.1.2007.1.4.92.1 | |||
| frEventObjects1 | 1.3.6.1.4.1.2007.1.4.92.1.1 | Event FR.1 A frame had been received on the FR interface. | ||
| I32 fr1_circuit | 1.3.6.1.4.1.2007.1.4.92.1.1.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.1 |
| STR fr1_protocol | 1.3.6.1.4.1.2007.1.4.92.1.1.2 | DisplayString | accessible-for-notify | Parameter 'protocol' in event FR.1 |
| I32 fr1_size | 1.3.6.1.4.1.2007.1.4.92.1.1.3 | Integer32 | accessible-for-notify | Parameter 'size' in event FR.1 |
| STR fr1_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.1.4 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.1 |
| STR fr1_buffer | 1.3.6.1.4.1.2007.1.4.92.1.1.5 | DisplayString | accessible-for-notify | Parameter 'buffer' in event FR.1 |
| frEventObjects2 | 1.3.6.1.4.1.2007.1.4.92.1.2 | Event FR.2 A frame had been transmitted on the FR interface. | ||
| I32 fr2_circuit | 1.3.6.1.4.1.2007.1.4.92.1.2.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.2 |
| STR fr2_protocol | 1.3.6.1.4.1.2007.1.4.92.1.2.2 | DisplayString | accessible-for-notify | Parameter 'protocol' in event FR.2 |
| I32 fr2_size | 1.3.6.1.4.1.2007.1.4.92.1.2.3 | Integer32 | accessible-for-notify | Parameter 'size' in event FR.2 |
| STR fr2_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.2.4 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.2 |
| STR fr2_buffer | 1.3.6.1.4.1.2007.1.4.92.1.2.5 | DisplayString | accessible-for-notify | Parameter 'buffer' in event FR.2 |
| frEventObjects3 | 1.3.6.1.4.1.2007.1.4.92.1.3 | Event FR.3 A protocol frame had been discarded due to the PVC congested condition. | ||
| I32 fr3_circuit | 1.3.6.1.4.1.2007.1.4.92.1.3.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.3 |
| STR fr3_protocol | 1.3.6.1.4.1.2007.1.4.92.1.3.2 | DisplayString | accessible-for-notify | Parameter 'protocol' in event FR.3 |
| STR fr3_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.3.3 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.3 |
| frEventObjects4 | 1.3.6.1.4.1.2007.1.4.92.1.4 | Event FR.4 The circuit is now experiencing congestion in the outbound direction. | ||
| I32 fr4_circuit | 1.3.6.1.4.1.2007.1.4.92.1.4.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.4 |
| STR fr4_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.4.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.4 |
| frEventObjects5 | 1.3.6.1.4.1.2007.1.4.92.1.5 | Event FR.5 The circuit is now not experiencing congestion in the outbound direction. | ||
| I32 fr5_circuit | 1.3.6.1.4.1.2007.1.4.92.1.5.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.5 |
| STR fr5_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.5.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.5 |
| frEventObjects6 | 1.3.6.1.4.1.2007.1.4.92.1.6 | Event FR.6 The circuit enters the active state. | ||
| I32 fr6_circuit | 1.3.6.1.4.1.2007.1.4.92.1.6.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.6 |
| STR fr6_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.6.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.6 |
| frEventObjects7 | 1.3.6.1.4.1.2007.1.4.92.1.7 | Event FR.7 The LMI signalled present and active a circuit which had not been statically configured. | ||
| I32 fr7_circuit | 1.3.6.1.4.1.2007.1.4.92.1.7.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.7 |
| STR fr7_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.7.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.7 |
| frEventObjects8 | 1.3.6.1.4.1.2007.1.4.92.1.8 | Event FR.8 The circuit enters the inactive state. | ||
| I32 fr8_circuit | 1.3.6.1.4.1.2007.1.4.92.1.8.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.8 |
| STR fr8_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.8.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.8 |
| frEventObjects9 | 1.3.6.1.4.1.2007.1.4.92.1.9 | Event FR.9 The circuit is no longer available on the network. | ||
| I32 fr9_circuit | 1.3.6.1.4.1.2007.1.4.92.1.9.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.9 |
| STR fr9_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.9.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.9 |
| frEventObjects10 | 1.3.6.1.4.1.2007.1.4.92.1.10 | Event FR.10 The circuit is now available on the network. | ||
| I32 fr10_circuit | 1.3.6.1.4.1.2007.1.4.92.1.10.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.10 |
| STR fr10_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.10.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.10 |
| frEventObjects11 | 1.3.6.1.4.1.2007.1.4.92.1.11 | Event FR.11 A LMI sequence number exchange has been requested. | ||
| I32 fr11_rcvseq | 1.3.6.1.4.1.2007.1.4.92.1.11.1 | Integer32 | accessible-for-notify | Parameter 'rcvseq' in event FR.11 |
| I32 fr11_xmtseq | 1.3.6.1.4.1.2007.1.4.92.1.11.2 | Integer32 | accessible-for-notify | Parameter 'xmtseq' in event FR.11 |
| STR fr11_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.11.3 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.11 |
| frEventObjects12 | 1.3.6.1.4.1.2007.1.4.92.1.12 | Event FR.12 A LMI full Status Enquiry has been requested. | ||
| STR fr12_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.12.1 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.12 |
| frEventObjects13 | 1.3.6.1.4.1.2007.1.4.92.1.13 | Event FR.13 A solicited LMI Status Enquiry response has been received. | ||
| STR fr13_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.13.1 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.13 |
| frEventObjects14 | 1.3.6.1.4.1.2007.1.4.92.1.14 | Event FR.14 A LMI full Status Enquiry response has been received. | ||
| STR fr14_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.14.1 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.14 |
| frEventObjects15 | 1.3.6.1.4.1.2007.1.4.92.1.15 | Event FR.15 A modem status change has occurred. The present state is described. | ||
| STR fr15_dcd | 1.3.6.1.4.1.2007.1.4.92.1.15.1 | DisplayString | accessible-for-notify | Parameter 'dcd' in event FR.15 |
| STR fr15_cts | 1.3.6.1.4.1.2007.1.4.92.1.15.2 | DisplayString | accessible-for-notify | Parameter 'cts' in event FR.15 |
| STR fr15_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.15.3 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.15 |
| frEventObjects16 | 1.3.6.1.4.1.2007.1.4.92.1.16 | Event FR.16 A multicast frame had been transmitted on the FR interface. | ||
| I32 fr16_circuit | 1.3.6.1.4.1.2007.1.4.92.1.16.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.16 |
| STR fr16_protocol | 1.3.6.1.4.1.2007.1.4.92.1.16.2 | DisplayString | accessible-for-notify | Parameter 'protocol' in event FR.16 |
| STR fr16_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.16.3 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.16 |
| frEventObjects17 | 1.3.6.1.4.1.2007.1.4.92.1.17 | Event FR.17 The circuit is remaining in the outbound congested state toward the network. | ||
| I32 fr17_circuit | 1.3.6.1.4.1.2007.1.4.92.1.17.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.17 |
| STR fr17_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.17.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.17 |
| frEventObjects18 | 1.3.6.1.4.1.2007.1.4.92.1.18 | Event FR.18 A protocol frame had been discarded due to the PVC exceeding the CIR on the circuit. | ||
| I32 fr18_circuit | 1.3.6.1.4.1.2007.1.4.92.1.18.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.18 |
| STR fr18_protocol | 1.3.6.1.4.1.2007.1.4.92.1.18.2 | DisplayString | accessible-for-notify | Parameter 'protocol' in event FR.18 |
| STR fr18_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.18.3 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.18 |
| frEventObjects19 | 1.3.6.1.4.1.2007.1.4.92.1.19 | Event FR.19 The LMI signalled present and active a circuit which had not been statically configured or allowed. | ||
| I32 fr19_circuit | 1.3.6.1.4.1.2007.1.4.92.1.19.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.19 |
| STR fr19_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.19.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.19 |
| frEventObjects20 | 1.3.6.1.4.1.2007.1.4.92.1.20 | Event FR.20 The LMI signalled present and active a circuit which cannot join the interface, maximum circuits have been exceeded. | ||
| I32 fr20_circuit | 1.3.6.1.4.1.2007.1.4.92.1.20.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.20 |
| STR fr20_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.20.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.20 |
| frEventObjects21 | 1.3.6.1.4.1.2007.1.4.92.1.21 | Event FR.21 The LMI signalled present and active a circuit which cannot join the interface, memory is unavailable. | ||
| I32 fr21_circuit | 1.3.6.1.4.1.2007.1.4.92.1.21.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.21 |
| STR fr21_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.21.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.21 |
| frEventObjects22 | 1.3.6.1.4.1.2007.1.4.92.1.22 | Event FR.22 An unsupported management information element has been encountered. | ||
| I32 fr22_type | 1.3.6.1.4.1.2007.1.4.92.1.22.1 | Integer32 | accessible-for-notify | Parameter 'type' in event FR.22 |
| STR fr22_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.22.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.22 |
| frEventObjects23 | 1.3.6.1.4.1.2007.1.4.92.1.23 | Event FR.23 An unsupported management message has been encountered. | ||
| I32 fr23_type | 1.3.6.1.4.1.2007.1.4.92.1.23.1 | Integer32 | accessible-for-notify | Parameter 'type' in event FR.23 |
| STR fr23_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.23.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.23 |
| frEventObjects24 | 1.3.6.1.4.1.2007.1.4.92.1.24 | Event FR.24 The LMI signalled present and active a multicast circuit. | ||
| I32 fr24_circuit | 1.3.6.1.4.1.2007.1.4.92.1.24.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.24 |
| I32 fr24_group | 1.3.6.1.4.1.2007.1.4.92.1.24.2 | Integer32 | accessible-for-notify | Parameter 'group' in event FR.24 |
| STR fr24_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.24.3 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.24 |
| frEventObjects25 | 1.3.6.1.4.1.2007.1.4.92.1.25 | Event FR.25 The LMI signalled present and active a multicast circuit. | ||
| I32 fr25_circuit | 1.3.6.1.4.1.2007.1.4.92.1.25.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.25 |
| I32 fr25_group | 1.3.6.1.4.1.2007.1.4.92.1.25.2 | Integer32 | accessible-for-notify | Parameter 'group' in event FR.25 |
| STR fr25_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.25.3 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.25 |
| frEventObjects26 | 1.3.6.1.4.1.2007.1.4.92.1.26 | Event FR.26 An unsupported network layer protocol NLPID has been encountered. | ||
| I32 fr26_type | 1.3.6.1.4.1.2007.1.4.92.1.26.1 | Integer32 | accessible-for-notify | Parameter 'type' in event FR.26 |
| I32 fr26_circuit | 1.3.6.1.4.1.2007.1.4.92.1.26.2 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.26 |
| I32 fr26_size | 1.3.6.1.4.1.2007.1.4.92.1.26.3 | Integer32 | accessible-for-notify | Parameter 'size' in event FR.26 |
| STR fr26_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.26.4 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.26 |
| frEventObjects27 | 1.3.6.1.4.1.2007.1.4.92.1.27 | Event FR.27 An unsupported Ethernet type has been encountered. | ||
| I32 fr27_type | 1.3.6.1.4.1.2007.1.4.92.1.27.1 | Integer32 | accessible-for-notify | Parameter 'type' in event FR.27 |
| I32 fr27_circuit | 1.3.6.1.4.1.2007.1.4.92.1.27.2 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.27 |
| I32 fr27_size | 1.3.6.1.4.1.2007.1.4.92.1.27.3 | Integer32 | accessible-for-notify | Parameter 'size' in event FR.27 |
| STR fr27_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.27.4 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.27 |
| frEventObjects28 | 1.3.6.1.4.1.2007.1.4.92.1.28 | Event FR.28 The LMI signalled present and active a multicast circuit that is not supported on the interface. | ||
| I32 fr28_circuit | 1.3.6.1.4.1.2007.1.4.92.1.28.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.28 |
| I32 fr28_group | 1.3.6.1.4.1.2007.1.4.92.1.28.2 | Integer32 | accessible-for-notify | Parameter 'group' in event FR.28 |
| STR fr28_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.28.3 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.28 |
| frEventObjects29 | 1.3.6.1.4.1.2007.1.4.92.1.29 | Event FR.29 Data has been received on a circuit not configured or learned dynamically but not yet active on network. | ||
| I32 fr29_circuit | 1.3.6.1.4.1.2007.1.4.92.1.29.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.29 |
| STR fr29_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.29.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.29 |
| frEventObjects30 | 1.3.6.1.4.1.2007.1.4.92.1.30 | Event FR.30 A LMI sequence number exchange has been received. | ||
| I32 fr30_rcvseq | 1.3.6.1.4.1.2007.1.4.92.1.30.1 | Integer32 | accessible-for-notify | Parameter 'rcvseq' in event FR.30 |
| I32 fr30_xmtseq | 1.3.6.1.4.1.2007.1.4.92.1.30.2 | Integer32 | accessible-for-notify | Parameter 'xmtseq' in event FR.30 |
| STR fr30_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.30.3 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.30 |
| frEventObjects31 | 1.3.6.1.4.1.2007.1.4.92.1.31 | Event FR.31 An LMI unsolicited single status update message has been received. | ||
| STR fr31_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.31.1 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.31 |
| frEventObjects32 | 1.3.6.1.4.1.2007.1.4.92.1.32 | Event FR.32 A frame containing less than the 2 octet minimum address length had been encountered. | ||
| STR fr32_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.32.1 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.32 |
| frEventObjects33 | 1.3.6.1.4.1.2007.1.4.92.1.33 | Event FR.33 A frame containing greater than the 2 octet maximum address length supported had been encountered. Currently, only 2 octet addressing is supported. | ||
| STR fr33_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.33.1 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.33 |
| frEventObjects34 | 1.3.6.1.4.1.2007.1.4.92.1.34 | Event FR.34 The LMI status message contained a reserved management channel address. | ||
| I32 fr34_circuit | 1.3.6.1.4.1.2007.1.4.92.1.34.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.34 |
| STR fr34_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.34.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.34 |
| frEventObjects35 | 1.3.6.1.4.1.2007.1.4.92.1.35 | Event FR.35 An unsupported link layer control frame encountered. | ||
| I32 fr35_type | 1.3.6.1.4.1.2007.1.4.92.1.35.1 | Integer32 | accessible-for-notify | Parameter 'type' in event FR.35 |
| I32 fr35_circuit | 1.3.6.1.4.1.2007.1.4.92.1.35.2 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.35 |
| STR fr35_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.35.3 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.35 |
| frEventObjects36 | 1.3.6.1.4.1.2007.1.4.92.1.36 | Event FR.36 An unsupported network layer protocol descriptor has been encountered. | ||
| I32 fr36_type | 1.3.6.1.4.1.2007.1.4.92.1.36.1 | Integer32 | accessible-for-notify | Parameter 'type' in event FR.36 |
| STR fr36_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.36.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.36 |
| frEventObjects37 | 1.3.6.1.4.1.2007.1.4.92.1.37 | Event FR.37 An unsupported network layer call reference field has been encountered. | ||
| STR fr37_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.37.1 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.37 |
| frEventObjects38 | 1.3.6.1.4.1.2007.1.4.92.1.38 | Event FR.38 The received ANSI management frame did not include required locking shift information element. | ||
| STR fr38_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.38.1 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.38 |
| frEventObjects39 | 1.3.6.1.4.1.2007.1.4.92.1.39 | Event FR.39 The received management frame information element was incorrectly formated. | ||
| STR fr39_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.39.1 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.39 |
| frEventObjects40 | 1.3.6.1.4.1.2007.1.4.92.1.40 | Event FR.40 An incorrect LMI receive sequence number has been received. | ||
| I32 fr40_rcvseq | 1.3.6.1.4.1.2007.1.4.92.1.40.1 | Integer32 | accessible-for-notify | Parameter 'rcvseq' in event FR.40 |
| I32 fr40_xmtseq | 1.3.6.1.4.1.2007.1.4.92.1.40.2 | Integer32 | accessible-for-notify | Parameter 'xmtseq' in event FR.40 |
| STR fr40_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.40.3 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.40 |
| frEventObjects41 | 1.3.6.1.4.1.2007.1.4.92.1.41 | Event FR.41 The LMI failed to signal the mentioned circuit is last network status update message. Circuit assumed removed from network. | ||
| I32 fr41_circuit | 1.3.6.1.4.1.2007.1.4.92.1.41.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.41 |
| STR fr41_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.41.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.41 |
| frEventObjects42 | 1.3.6.1.4.1.2007.1.4.92.1.42 | Event FR.42 The circuit is now experiencing congestion in the inbound direction. | ||
| I32 fr42_circuit | 1.3.6.1.4.1.2007.1.4.92.1.42.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.42 |
| STR fr42_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.42.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.42 |
| frEventObjects43 | 1.3.6.1.4.1.2007.1.4.92.1.43 | Event FR.43 The address header on received management frame had BECN, FECN, DE or CR bits set. | ||
| STR fr43_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.43.1 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.43 |
| frEventObjects44 | 1.3.6.1.4.1.2007.1.4.92.1.44 | Event FR.44 LMI Link Integrity Verification message was received from the network without the router polling for it. | ||
| STR fr44_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.44.1 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.44 |
| frEventObjects45 | 1.3.6.1.4.1.2007.1.4.92.1.45 | Event FR.45 LMI Full Status message was received from the network without the router polling for it. | ||
| STR fr45_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.45.1 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.45 |
| frEventObjects46 | 1.3.6.1.4.1.2007.1.4.92.1.46 | Event FR.46 A frame was received of a bridge type defined in RFC 1490. However, since bridging has not been enabled on this circuit, frame is being discarded. | ||
| I32 fr46_circuit | 1.3.6.1.4.1.2007.1.4.92.1.46.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.46 |
| STR fr46_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.46.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.46 |
| frEventObjects47 | 1.3.6.1.4.1.2007.1.4.92.1.47 | Event FR.47 A bridge frame is being discarded as a bridge port is not in forwarding state. | ||
| I32 fr47_circuit | 1.3.6.1.4.1.2007.1.4.92.1.47.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.47 |
| STR fr47_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.47.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.47 |
| frEventObjects48 | 1.3.6.1.4.1.2007.1.4.92.1.48 | Event FR.48 A bridged frame has been received and is being discarded due to mismatch in the frame type versus the bridge port behavior. | ||
| STR fr48_source_mac | 1.3.6.1.4.1.2007.1.4.92.1.48.1 | DisplayString | accessible-for-notify | Parameter 'source-mac' in event FR.48 |
| STR fr48_dest_mac | 1.3.6.1.4.1.2007.1.4.92.1.48.2 | DisplayString | accessible-for-notify | Parameter 'dest-mac' in event FR.48 |
| I32 fr48_circuit | 1.3.6.1.4.1.2007.1.4.92.1.48.3 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.48 |
| STR fr48_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.48.4 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.48 |
| frEventObjects49 | 1.3.6.1.4.1.2007.1.4.92.1.49 | Event FR.49 An unsupported bridge frame type has been encountered. | ||
| I32 fr49_type | 1.3.6.1.4.1.2007.1.4.92.1.49.1 | Integer32 | accessible-for-notify | Parameter 'type' in event FR.49 |
| I32 fr49_circuit | 1.3.6.1.4.1.2007.1.4.92.1.49.2 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.49 |
| STR fr49_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.49.3 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.49 |
| frEventObjects50 | 1.3.6.1.4.1.2007.1.4.92.1.50 | Event FR.50 An unrecognized outgoing bridge frame type. Bridge has asked the Frame Relay interface to send out a frame whose type cannot be translated into encapsulation defined in RFC 1490. | ||
| I32 fr50_type | 1.3.6.1.4.1.2007.1.4.92.1.50.1 | Integer32 | accessible-for-notify | Parameter 'type' in event FR.50 |
| I32 fr50_circuit | 1.3.6.1.4.1.2007.1.4.92.1.50.2 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.50 |
| STR fr50_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.50.3 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.50 |
| frEventObjects51 | 1.3.6.1.4.1.2007.1.4.92.1.51 | Event FR.51 A protocol frame has been discarded because it could not be queued for transmission. | ||
| I32 fr51_circuit | 1.3.6.1.4.1.2007.1.4.92.1.51.1 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.51 |
| STR fr51_protocol | 1.3.6.1.4.1.2007.1.4.92.1.51.2 | DisplayString | accessible-for-notify | Parameter 'protocol' in event FR.51 |
| STR fr51_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.51.3 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.51 |
| frEventObjects52 | 1.3.6.1.4.1.2007.1.4.92.1.52 | Event FR.52 An LMI send sequence number of 0 has been received. | ||
| I32 fr52_sndseq | 1.3.6.1.4.1.2007.1.4.92.1.52.1 | Integer32 | accessible-for-notify | Parameter 'sndseq' in event FR.52 |
| STR fr52_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.52.2 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.52 |
| frEventObjects53 | 1.3.6.1.4.1.2007.1.4.92.1.53 | Event FR.53 A FRF.12 fragment is processed and a event is reported. | ||
| STR fr53_message | 1.3.6.1.4.1.2007.1.4.92.1.53.1 | DisplayString | accessible-for-notify | Parameter 'message' in event FR.53 |
| I32 fr53_header | 1.3.6.1.4.1.2007.1.4.92.1.53.2 | Integer32 | accessible-for-notify | Parameter 'header' in event FR.53 |
| I32 fr53_circuit | 1.3.6.1.4.1.2007.1.4.92.1.53.3 | Integer32 | accessible-for-notify | Parameter 'circuit' in event FR.53 |
| I32 fr53_size | 1.3.6.1.4.1.2007.1.4.92.1.53.4 | Integer32 | accessible-for-notify | Parameter 'size' in event FR.53 |
| STR fr53_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.53.5 | DisplayString | accessible-for-notify | Parameter 'ifcname' in event FR.53 |
| frNotifications | 1.3.6.1.4.1.2007.1.4.92.2 | |||
| frNotificationsPrefix | 1.3.6.1.4.1.2007.1.4.92.2.0 | |||
| NTF frNotification1 | 1.3.6.1.4.1.2007.1.4.92.2.0.1 | Notification of Event FR.1 Message: 'Frame received, PVC = $1 protocol type = $2 size $3 bytes, on interface $4HexadecimalData: $5' Parameters list: $1: fr1-circuit $2: fr1-protocol $3: fr1-size $4: fr1-ifcname $5: fr1-buffer A frame had been received on the FR interface. | ||
| NTF frNotification2 | 1.3.6.1.4.1.2007.1.4.92.2.0.2 | Notification of Event FR.2 Message: 'Frame transmitted PVC = $1 protocol type = $2 size $3 bytes, on interface $4HexadecimalData: $5' Parameters list: $1: fr2-circuit $2: fr2-protocol $3: fr2-size $4: fr2-ifcname $5: fr2-buffer A frame had been transmitted on the FR interface. | ||
| NTF frNotification3 | 1.3.6.1.4.1.2007.1.4.92.2.0.3 | Notification of Event FR.3 Message: 'Transmit frame discarded PVC = $1 protocol type = $2, on interface $3' Parameters list: $1: fr3-circuit $2: fr3-protocol $3: fr3-ifcname A protocol frame had been discarded due to the PVC congested condition. | ||
| NTF frNotification4 | 1.3.6.1.4.1.2007.1.4.92.2.0.4 | Notification of Event FR.4 Message: 'Circuit outbound congestion PVC = $1, on interface $2' Parameters list: $1: fr4-circuit $2: fr4-ifcname The circuit is now experiencing congestion in the outbound direction. | ||
| NTF frNotification5 | 1.3.6.1.4.1.2007.1.4.92.2.0.5 | Notification of Event FR.5 Message: 'Circuit outbound uncongested PVC = $1, on interface $2' Parameters list: $1: fr5-circuit $2: fr5-ifcname The circuit is now not experiencing congestion in the outbound direction. | ||
| NTF frNotification6 | 1.3.6.1.4.1.2007.1.4.92.2.0.6 | Notification of Event FR.6 Message: 'Circuit enters active state PVC = $1, on interface $2' Parameters list: $1: fr6-circuit $2: fr6-ifcname The circuit enters the active state. | ||
| NTF frNotification7 | 1.3.6.1.4.1.2007.1.4.92.2.0.7 | Notification of Event FR.7 Message: 'An orphan circuit not statically configured has joined the network PVC = $1, on interface $2' Parameters list: $1: fr7-circuit $2: fr7-ifcname The LMI signalled present and active a circuit which had not been statically configured. | ||
| NTF frNotification8 | 1.3.6.1.4.1.2007.1.4.92.2.0.8 | Notification of Event FR.8 Message: 'Circuit enters inactive state PVC = $1, on interface $2' Parameters list: $1: fr8-circuit $2: fr8-ifcname The circuit enters the inactive state. | ||
| NTF frNotification9 | 1.3.6.1.4.1.2007.1.4.92.2.0.9 | Notification of Event FR.9 Message: 'Circuit is unavailable PVC = $1, on interface $2' Parameters list: $1: fr9-circuit $2: fr9-ifcname The circuit is no longer available on the network. | ||
| NTF frNotification10 | 1.3.6.1.4.1.2007.1.4.92.2.0.10 | Notification of Event FR.10 Message: 'Circuit is available PVC = $1, on interface $2' Parameters list: $1: fr10-circuit $2: fr10-ifcname The circuit is now available on the network. | ||
| NTF frNotification11 | 1.3.6.1.4.1.2007.1.4.92.2.0.11 | Notification of Event FR.11 Message: 'LMI sequence number exchange requested, last received sequence = $1, current transmit sequence = $2, on interface $3' Parameters list: $1: fr11-rcvseq $2: fr11-xmtseq $3: fr11-ifcname A LMI sequence number exchange has been requested. | ||
| NTF frNotification12 | 1.3.6.1.4.1.2007.1.4.92.2.0.12 | Notification of Event FR.12 Message: 'LMI Status Enquiry requested on interface $1' Parameters list: $1: fr12-ifcname A LMI full Status Enquiry has been requested. | ||
| NTF frNotification13 | 1.3.6.1.4.1.2007.1.4.92.2.0.13 | Notification of Event FR.13 Message: 'LMI solicited Status Enquiry response had been received on interface $1' Parameters list: $1: fr13-ifcname A solicited LMI Status Enquiry response has been received. | ||
| NTF frNotification14 | 1.3.6.1.4.1.2007.1.4.92.2.0.14 | Notification of Event FR.14 Message: 'LMI Full Status Enquiry response had been received on interface $1' Parameters list: $1: fr14-ifcname A LMI full Status Enquiry response has been received. | ||
| NTF frNotification15 | 1.3.6.1.4.1.2007.1.4.92.2.0.15 | Notification of Event FR.15 Message: 'Modem status changed DCD = $1 CTS = $2 on interface $3' Parameters list: $1: fr15-dcd $2: fr15-cts $3: fr15-ifcname A modem status change has occurred. The present state is described. | ||
| NTF frNotification16 | 1.3.6.1.4.1.2007.1.4.92.2.0.16 | Notification of Event FR.16 Message: 'Multicast frame transmitted PVC = $1 protocol type = $2, on interface $3' Parameters list: $1: fr16-circuit $2: fr16-protocol $3: fr16-ifcname A multicast frame had been transmitted on the FR interface. | ||
| NTF frNotification17 | 1.3.6.1.4.1.2007.1.4.92.2.0.17 | Notification of Event FR.17 Message: 'Circuit remains congested in the outbound direction PVC = $1, on interface $2' Parameters list: $1: fr17-circuit $2: fr17-ifcname The circuit is remaining in the outbound congested state toward the network. | ||
| NTF frNotification18 | 1.3.6.1.4.1.2007.1.4.92.2.0.18 | Notification of Event FR.18 Message: 'CIR exceeded, transmit frame discarded PVC = $1 protocol type = $2, on interface $3' Parameters list: $1: fr18-circuit $2: fr18-protocol $3: fr18-ifcname A protocol frame had been discarded due to the PVC exceeding the CIR on the circuit. | ||
| NTF frNotification19 | 1.3.6.1.4.1.2007.1.4.92.2.0.19 | Notification of Event FR.19 Message: 'A disallowed orphan circuit not statically configured has been ignored PVC = $1, on interface $2' Parameters list: $1: fr19-circuit $2: fr19-ifcname The LMI signalled present and active a circuit which had not been statically configured or allowed. | ||
| NTF frNotification20 | 1.3.6.1.4.1.2007.1.4.92.2.0.20 | Notification of Event FR.20 Message: 'The total circuits allowed has been exceeded, an orphan circuit has been ignored PVC = $1, on interface $2' Parameters list: $1: fr20-circuit $2: fr20-ifcname The LMI signalled present and active a circuit which cannot join the interface, maximum circuits have been exceeded. | ||
| NTF frNotification21 | 1.3.6.1.4.1.2007.1.4.92.2.0.21 | Notification of Event FR.21 Message: 'No available memory for orphan circuit, the circuit has been ignored PVC = $1, on interface $2' Parameters list: $1: fr21-circuit $2: fr21-ifcname The LMI signalled present and active a circuit which cannot join the interface, memory is unavailable. | ||
| NTF frNotification22 | 1.3.6.1.4.1.2007.1.4.92.2.0.22 | Notification of Event FR.22 Message: 'Unsupported LMI information element, type = $1 on interface $2' Parameters list: $1: fr22-type $2: fr22-ifcname An unsupported management information element has been encountered. | ||
| NTF frNotification23 | 1.3.6.1.4.1.2007.1.4.92.2.0.23 | Notification of Event FR.23 Message: 'Unsupported LMI message type, type encountered = $1, on interface $2' Parameters list: $1: fr23-type $2: fr23-ifcname An unsupported management message has been encountered. | ||
| NTF frNotification24 | 1.3.6.1.4.1.2007.1.4.92.2.0.24 | Notification of Event FR.24 Message: 'A multicast circuit has joined the network PVC = $1, in multicast group = $2 on interface $3' Parameters list: $1: fr24-circuit $2: fr24-group $3: fr24-ifcname The LMI signalled present and active a multicast circuit. | ||
| NTF frNotification25 | 1.3.6.1.4.1.2007.1.4.92.2.0.25 | Notification of Event FR.25 Message: 'An multicast circuit has left the network PVC = $1, from multicast group = $2 on interface $3' Parameters list: $1: fr25-circuit $2: fr25-group $3: fr25-ifcname The LMI signalled present and active a multicast circuit. | ||
| NTF frNotification26 | 1.3.6.1.4.1.2007.1.4.92.2.0.26 | Notification of Event FR.26 Message: 'Unsupported Network Layer Protocol ID, type = $1 from PVC = $2 size $3 bytes on interface $4' Parameters list: $1: fr26-type $2: fr26-circuit $3: fr26-size $4: fr26-ifcname An unsupported network layer protocol NLPID has been encountered. | ||
| NTF frNotification27 | 1.3.6.1.4.1.2007.1.4.92.2.0.27 | Notification of Event FR.27 Message: 'Unsupported ethernet type, type = $1 from PVC = $2 size $3 bytes on interface $4' Parameters list: $1: fr27-type $2: fr27-circuit $3: fr27-size $4: fr27-ifcname An unsupported Ethernet type has been encountered. | ||
| NTF frNotification28 | 1.3.6.1.4.1.2007.1.4.92.2.0.28 | Notification of Event FR.28 Message: 'An unsupported multicast circuit has been ignored, PVC = $1, in multicast group = $2 on interface $3' Parameters list: $1: fr28-circuit $2: fr28-group $3: fr28-ifcname The LMI signalled present and active a multicast circuit that is not supported on the interface. | ||
| NTF frNotification29 | 1.3.6.1.4.1.2007.1.4.92.2.0.29 | Notification of Event FR.29 Message: 'Data received on invalid or nonconfigured circuit, PVC = $1 on interface $2' Parameters list: $1: fr29-circuit $2: fr29-ifcname Data has been received on a circuit not configured or learned dynamically but not yet active on network. | ||
| NTF frNotification30 | 1.3.6.1.4.1.2007.1.4.92.2.0.30 | Notification of Event FR.30 Message: 'LMI sequence number exchange received, last received sequence = $1 current transmit sequence = $2, on interface $3' Parameters list: $1: fr30-rcvseq $2: fr30-xmtseq $3: fr30-ifcname A LMI sequence number exchange has been received. | ||
| NTF frNotification31 | 1.3.6.1.4.1.2007.1.4.92.2.0.31 | Notification of Event FR.31 Message: 'LMI unsolicited single Status Update had been received on interface $1' Parameters list: $1: fr31-ifcname An LMI unsolicited single status update message has been received. | ||
| NTF frNotification32 | 1.3.6.1.4.1.2007.1.4.92.2.0.32 | Notification of Event FR.32 Message: 'Circuit address length less than the 2 octet minimum received on interface $1' Parameters list: $1: fr32-ifcname A frame containing less than the 2 octet minimum address length had been encountered. | ||
| NTF frNotification33 | 1.3.6.1.4.1.2007.1.4.92.2.0.33 | Notification of Event FR.33 Message: 'Circuit address length greater than the 2 octet maximum received on interface $1' Parameters list: $1: fr33-ifcname A frame containing greater than the 2 octet maximum address length supported had been encountered. Currently, only 2 octet addressing is supported. | ||
| NTF frNotification34 | 1.3.6.1.4.1.2007.1.4.92.2.0.34 | Notification of Event FR.34 Message: 'Circuit status update message contained a reserved management channel address, PVC = $1, on interface $2' Parameters list: $1: fr34-circuit $2: fr34-ifcname The LMI status message contained a reserved management channel address. | ||
| NTF frNotification35 | 1.3.6.1.4.1.2007.1.4.92.2.0.35 | Notification of Event FR.35 Message: 'Unsupported Link Layer Control frame encountered, type = $1 from PVC = $2 on interface $3' Parameters list: $1: fr35-type $2: fr35-circuit $3: fr35-ifcname An unsupported link layer control frame encountered. | ||
| NTF frNotification36 | 1.3.6.1.4.1.2007.1.4.92.2.0.36 | Notification of Event FR.36 Message: 'Unsupported layer management protocol descriptor encountered, type = $1 on interface $2' Parameters list: $1: fr36-type $2: fr36-ifcname An unsupported network layer protocol descriptor has been encountered. | ||
| NTF frNotification37 | 1.3.6.1.4.1.2007.1.4.92.2.0.37 | Notification of Event FR.37 Message: 'Unsupported layer management call reference encountered on interface $1' Parameters list: $1: fr37-ifcname An unsupported network layer call reference field has been encountered. | ||
| NTF frNotification38 | 1.3.6.1.4.1.2007.1.4.92.2.0.38 | Notification of Event FR.38 Message: 'No lock shift encountered in received ANSI LMI message on interface $1' Parameters list: $1: fr38-ifcname The received ANSI management frame did not include required locking shift information element. | ||
| NTF frNotification39 | 1.3.6.1.4.1.2007.1.4.92.2.0.39 | Notification of Event FR.39 Message: 'Incorrect formated information element encountered on interface $1' Parameters list: $1: fr39-ifcname The received management frame information element was incorrectly formated. | ||
| NTF frNotification40 | 1.3.6.1.4.1.2007.1.4.92.2.0.40 | Notification of Event FR.40 Message: 'LMI receive sequence number in error, receive sequence = $1 expected sequence = $2, on interface $3' Parameters list: $1: fr40-rcvseq $2: fr40-xmtseq $3: fr40-ifcname An incorrect LMI receive sequence number has been received. | ||
| NTF frNotification41 | 1.3.6.1.4.1.2007.1.4.92.2.0.41 | Notification of Event FR.41 Message: 'An circuit has been removed from the network PVC = $1, on interface $2' Parameters list: $1: fr41-circuit $2: fr41-ifcname The LMI failed to signal the mentioned circuit is last network status update message. Circuit assumed removed from network. | ||
| NTF frNotification42 | 1.3.6.1.4.1.2007.1.4.92.2.0.42 | Notification of Event FR.42 Message: 'Circuit inbound congestion PVC = $1, on interface $2' Parameters list: $1: fr42-circuit $2: fr42-ifcname The circuit is now experiencing congestion in the inbound direction. | ||
| NTF frNotification43 | 1.3.6.1.4.1.2007.1.4.92.2.0.43 | Notification of Event FR.43 Message: 'Incorrect formatted address header for LMI packet encountered on interface $1' Parameters list: $1: fr43-ifcname The address header on received management frame had BECN, FECN, DE or CR bits set. | ||
| NTF frNotification44 | 1.3.6.1.4.1.2007.1.4.92.2.0.44 | Notification of Event FR.44 Message: 'Unsolicited LMI Link Integrity Verification received on interface $1' Parameters list: $1: fr44-ifcname LMI Link Integrity Verification message was received from the network without the router polling for it. | ||
| NTF frNotification45 | 1.3.6.1.4.1.2007.1.4.92.2.0.45 | Notification of Event FR.45 Message: 'Unsolicited LMI FULL STATUS response received on interface $1' Parameters list: $1: fr45-ifcname LMI Full Status message was received from the network without the router polling for it. | ||
| NTF frNotification46 | 1.3.6.1.4.1.2007.1.4.92.2.0.46 | Notification of Event FR.46 Message: 'DROP: Bridging not enabled on PVC=$1, on interface $2' Parameters list: $1: fr46-circuit $2: fr46-ifcname A frame was received of a bridge type defined in RFC 1490. However, since bridging has not been enabled on this circuit, frame is being discarded. | ||
| NTF frNotification47 | 1.3.6.1.4.1.2007.1.4.92.2.0.47 | Notification of Event FR.47 Message: 'DROP: Bridge port not forwarding on PVC=$1, on interface $2' Parameters list: $1: fr47-circuit $2: fr47-ifcname A bridge frame is being discarded as a bridge port is not in forwarding state. | ||
| NTF frNotification48 | 1.3.6.1.4.1.2007.1.4.92.2.0.48 | Notification of Event FR.48 Message: 'DROP: $1->$2, Frame to bridge port behavior mismatch on PVC=$3, on interface $4' Parameters list: $1: fr48-source-mac $2: fr48-dest-mac $3: fr48-circuit $4: fr48-ifcname A bridged frame has been received and is being discarded due to mismatch in the frame type versus the bridge port behavior. | ||
| NTF frNotification49 | 1.3.6.1.4.1.2007.1.4.92.2.0.49 | Notification of Event FR.49 Message: 'Unsupported bridge frame type = $1 from PVC = $2 on interface $3' Parameters list: $1: fr49-type $2: fr49-circuit $3: fr49-ifcname An unsupported bridge frame type has been encountered. | ||
| NTF frNotification50 | 1.3.6.1.4.1.2007.1.4.92.2.0.50 | Notification of Event FR.50 Message: 'Unrecognized outgoing bridge frame type = $1 on PVC = $2 on interface $3' Parameters list: $1: fr50-type $2: fr50-circuit $3: fr50-ifcname An unrecognized outgoing bridge frame type. Bridge has asked the Frame Relay interface to send out a frame whose type cannot be translated into encapsulation defined in RFC 1490. | ||
| NTF frNotification51 | 1.3.6.1.4.1.2007.1.4.92.2.0.51 | Notification of Event FR.51 Message: 'Transmit frame discarded PVC = $1 protocol type = $2, on interface $3' Parameters list: $1: fr51-circuit $2: fr51-protocol $3: fr51-ifcname A protocol frame has been discarded because it could not be queued for transmission. | ||
| NTF frNotification52 | 1.3.6.1.4.1.2007.1.4.92.2.0.52 | Notification of Event FR.52 Message: 'LMI send sequence number in error, sequence = $1, on interface $2' Parameters list: $1: fr52-sndseq $2: fr52-ifcname An LMI send sequence number of 0 has been received. | ||
| NTF frNotification53 | 1.3.6.1.4.1.2007.1.4.92.2.0.53 | Notification of Event FR.53 Message: 'FRF.12 $1 header $2 on PVC = $3 size $4 bytes, on interface $5' Parameters list: $1: fr53-message $2: fr53-header $3: fr53-circuit $4: fr53-size $5: fr53-ifcname A FRF.12 fragment is processed and a event is reported. |
RFC description
Defines SNMP notifications generated by the Frame Relay event subsystem on Teldat devices.
Start monitoring Teldat router platforms with Frame Relay WAN interfaces (DLCI/LMI signaling event traps) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.