-- file automatically created TELDAT-TRAP-FR-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY,OBJECT-TYPE,OBJECT-IDENTITY,NOTIFICATION-TYPE,Integer32,IpAddress FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC telEventTraps FROM TELDAT-MIB; frTrapsMIB MODULE-IDENTITY LAST-UPDATED "201401200930Z" ORGANIZATION "Teldat, S.A." CONTACT-INFO "Teldat, S.A. Customer Service Postal: Parque Tecnologico de Madrid Tres Cantos 28760 Madrid, SPAIN Tel.: +34 918 076 565 http://www.teldat.com" DESCRIPTION "This Module Information Base file is defined for managing received SNMP notifications generated by the FR event subsystem." REVISION "201401200930Z" DESCRIPTION "Initial implementation" ::= { telEventTraps 92 } frEventsGroup OBJECT IDENTIFIER ::= { frTrapsMIB 1 } frNotifications OBJECT IDENTIFIER ::= { frTrapsMIB 2 } frNotificationsPrefix OBJECT IDENTIFIER ::= { frNotifications 0 } frEventObjects1 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.1 A frame had been received on the FR interface." ::= { frEventsGroup 1 } fr1-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.1" ::= { frEventObjects1 1 } fr1-protocol OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'protocol' in event FR.1" ::= { frEventObjects1 2 } fr1-size OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'size' in event FR.1" ::= { frEventObjects1 3 } fr1-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.1" ::= { frEventObjects1 4 } fr1-buffer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'buffer' in event FR.1" ::= { frEventObjects1 5 } frEventObjects2 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.2 A frame had been transmitted on the FR interface." ::= { frEventsGroup 2 } fr2-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.2" ::= { frEventObjects2 1 } fr2-protocol OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'protocol' in event FR.2" ::= { frEventObjects2 2 } fr2-size OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'size' in event FR.2" ::= { frEventObjects2 3 } fr2-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.2" ::= { frEventObjects2 4 } fr2-buffer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'buffer' in event FR.2" ::= { frEventObjects2 5 } frEventObjects3 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.3 A protocol frame had been discarded due to the PVC congested condition." ::= { frEventsGroup 3 } fr3-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.3" ::= { frEventObjects3 1 } fr3-protocol OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'protocol' in event FR.3" ::= { frEventObjects3 2 } fr3-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.3" ::= { frEventObjects3 3 } frEventObjects4 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.4 The circuit is now experiencing congestion in the outbound direction." ::= { frEventsGroup 4 } fr4-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.4" ::= { frEventObjects4 1 } fr4-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.4" ::= { frEventObjects4 2 } frEventObjects5 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.5 The circuit is now not experiencing congestion in the outbound direction." ::= { frEventsGroup 5 } fr5-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.5" ::= { frEventObjects5 1 } fr5-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.5" ::= { frEventObjects5 2 } frEventObjects6 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.6 The circuit enters the active state." ::= { frEventsGroup 6 } fr6-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.6" ::= { frEventObjects6 1 } fr6-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.6" ::= { frEventObjects6 2 } frEventObjects7 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.7 The LMI signalled present and active a circuit which had not been statically configured." ::= { frEventsGroup 7 } fr7-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.7" ::= { frEventObjects7 1 } fr7-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.7" ::= { frEventObjects7 2 } frEventObjects8 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.8 The circuit enters the inactive state." ::= { frEventsGroup 8 } fr8-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.8" ::= { frEventObjects8 1 } fr8-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.8" ::= { frEventObjects8 2 } frEventObjects9 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.9 The circuit is no longer available on the network." ::= { frEventsGroup 9 } fr9-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.9" ::= { frEventObjects9 1 } fr9-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.9" ::= { frEventObjects9 2 } frEventObjects10 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.10 The circuit is now available on the network." ::= { frEventsGroup 10 } fr10-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.10" ::= { frEventObjects10 1 } fr10-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.10" ::= { frEventObjects10 2 } frEventObjects11 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.11 A LMI sequence number exchange has been requested." ::= { frEventsGroup 11 } fr11-rcvseq OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'rcvseq' in event FR.11" ::= { frEventObjects11 1 } fr11-xmtseq OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'xmtseq' in event FR.11" ::= { frEventObjects11 2 } fr11-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.11" ::= { frEventObjects11 3 } frEventObjects12 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.12 A LMI full Status Enquiry has been requested." ::= { frEventsGroup 12 } fr12-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.12" ::= { frEventObjects12 1 } frEventObjects13 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.13 A solicited LMI Status Enquiry response has been received." ::= { frEventsGroup 13 } fr13-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.13" ::= { frEventObjects13 1 } frEventObjects14 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.14 A LMI full Status Enquiry response has been received." ::= { frEventsGroup 14 } fr14-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.14" ::= { frEventObjects14 1 } frEventObjects15 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.15 A modem status change has occurred. The present state is described." ::= { frEventsGroup 15 } fr15-dcd OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'dcd' in event FR.15" ::= { frEventObjects15 1 } fr15-cts OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'cts' in event FR.15" ::= { frEventObjects15 2 } fr15-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.15" ::= { frEventObjects15 3 } frEventObjects16 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.16 A multicast frame had been transmitted on the FR interface." ::= { frEventsGroup 16 } fr16-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.16" ::= { frEventObjects16 1 } fr16-protocol OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'protocol' in event FR.16" ::= { frEventObjects16 2 } fr16-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.16" ::= { frEventObjects16 3 } frEventObjects17 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.17 The circuit is remaining in the outbound congested state toward the network." ::= { frEventsGroup 17 } fr17-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.17" ::= { frEventObjects17 1 } fr17-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.17" ::= { frEventObjects17 2 } frEventObjects18 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.18 A protocol frame had been discarded due to the PVC exceeding the CIR on the circuit." ::= { frEventsGroup 18 } fr18-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.18" ::= { frEventObjects18 1 } fr18-protocol OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'protocol' in event FR.18" ::= { frEventObjects18 2 } fr18-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.18" ::= { frEventObjects18 3 } frEventObjects19 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.19 The LMI signalled present and active a circuit which had not been statically configured or allowed." ::= { frEventsGroup 19 } fr19-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.19" ::= { frEventObjects19 1 } fr19-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.19" ::= { frEventObjects19 2 } frEventObjects20 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.20 The LMI signalled present and active a circuit which cannot join the interface, maximum circuits have been exceeded." ::= { frEventsGroup 20 } fr20-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.20" ::= { frEventObjects20 1 } fr20-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.20" ::= { frEventObjects20 2 } frEventObjects21 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.21 The LMI signalled present and active a circuit which cannot join the interface, memory is unavailable." ::= { frEventsGroup 21 } fr21-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.21" ::= { frEventObjects21 1 } fr21-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.21" ::= { frEventObjects21 2 } frEventObjects22 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.22 An unsupported management information element has been encountered." ::= { frEventsGroup 22 } fr22-type OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'type' in event FR.22" ::= { frEventObjects22 1 } fr22-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.22" ::= { frEventObjects22 2 } frEventObjects23 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.23 An unsupported management message has been encountered." ::= { frEventsGroup 23 } fr23-type OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'type' in event FR.23" ::= { frEventObjects23 1 } fr23-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.23" ::= { frEventObjects23 2 } frEventObjects24 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.24 The LMI signalled present and active a multicast circuit." ::= { frEventsGroup 24 } fr24-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.24" ::= { frEventObjects24 1 } fr24-group OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'group' in event FR.24" ::= { frEventObjects24 2 } fr24-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.24" ::= { frEventObjects24 3 } frEventObjects25 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.25 The LMI signalled present and active a multicast circuit." ::= { frEventsGroup 25 } fr25-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.25" ::= { frEventObjects25 1 } fr25-group OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'group' in event FR.25" ::= { frEventObjects25 2 } fr25-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.25" ::= { frEventObjects25 3 } frEventObjects26 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.26 An unsupported network layer protocol NLPID has been encountered." ::= { frEventsGroup 26 } fr26-type OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'type' in event FR.26" ::= { frEventObjects26 1 } fr26-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.26" ::= { frEventObjects26 2 } fr26-size OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'size' in event FR.26" ::= { frEventObjects26 3 } fr26-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.26" ::= { frEventObjects26 4 } frEventObjects27 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.27 An unsupported Ethernet type has been encountered." ::= { frEventsGroup 27 } fr27-type OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'type' in event FR.27" ::= { frEventObjects27 1 } fr27-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.27" ::= { frEventObjects27 2 } fr27-size OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'size' in event FR.27" ::= { frEventObjects27 3 } fr27-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.27" ::= { frEventObjects27 4 } frEventObjects28 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.28 The LMI signalled present and active a multicast circuit that is not supported on the interface." ::= { frEventsGroup 28 } fr28-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.28" ::= { frEventObjects28 1 } fr28-group OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'group' in event FR.28" ::= { frEventObjects28 2 } fr28-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.28" ::= { frEventObjects28 3 } frEventObjects29 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.29 Data has been received on a circuit not configured or learned dynamically but not yet active on network." ::= { frEventsGroup 29 } fr29-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.29" ::= { frEventObjects29 1 } fr29-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.29" ::= { frEventObjects29 2 } frEventObjects30 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.30 A LMI sequence number exchange has been received." ::= { frEventsGroup 30 } fr30-rcvseq OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'rcvseq' in event FR.30" ::= { frEventObjects30 1 } fr30-xmtseq OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'xmtseq' in event FR.30" ::= { frEventObjects30 2 } fr30-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.30" ::= { frEventObjects30 3 } frEventObjects31 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.31 An LMI unsolicited single status update message has been received." ::= { frEventsGroup 31 } fr31-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.31" ::= { frEventObjects31 1 } frEventObjects32 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.32 A frame containing less than the 2 octet minimum address length had been encountered." ::= { frEventsGroup 32 } fr32-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.32" ::= { frEventObjects32 1 } frEventObjects33 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.33 A frame containing greater than the 2 octet maximum address length supported had been encountered. Currently, only 2 octet addressing is supported." ::= { frEventsGroup 33 } fr33-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.33" ::= { frEventObjects33 1 } frEventObjects34 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.34 The LMI status message contained a reserved management channel address." ::= { frEventsGroup 34 } fr34-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.34" ::= { frEventObjects34 1 } fr34-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.34" ::= { frEventObjects34 2 } frEventObjects35 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.35 An unsupported link layer control frame encountered." ::= { frEventsGroup 35 } fr35-type OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'type' in event FR.35" ::= { frEventObjects35 1 } fr35-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.35" ::= { frEventObjects35 2 } fr35-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.35" ::= { frEventObjects35 3 } frEventObjects36 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.36 An unsupported network layer protocol descriptor has been encountered." ::= { frEventsGroup 36 } fr36-type OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'type' in event FR.36" ::= { frEventObjects36 1 } fr36-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.36" ::= { frEventObjects36 2 } frEventObjects37 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.37 An unsupported network layer call reference field has been encountered." ::= { frEventsGroup 37 } fr37-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.37" ::= { frEventObjects37 1 } frEventObjects38 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.38 The received ANSI management frame did not include required locking shift information element." ::= { frEventsGroup 38 } fr38-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.38" ::= { frEventObjects38 1 } frEventObjects39 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.39 The received management frame information element was incorrectly formated." ::= { frEventsGroup 39 } fr39-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.39" ::= { frEventObjects39 1 } frEventObjects40 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.40 An incorrect LMI receive sequence number has been received." ::= { frEventsGroup 40 } fr40-rcvseq OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'rcvseq' in event FR.40" ::= { frEventObjects40 1 } fr40-xmtseq OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'xmtseq' in event FR.40" ::= { frEventObjects40 2 } fr40-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.40" ::= { frEventObjects40 3 } frEventObjects41 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.41 The LMI failed to signal the mentioned circuit is last network status update message. Circuit assumed removed from network." ::= { frEventsGroup 41 } fr41-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.41" ::= { frEventObjects41 1 } fr41-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.41" ::= { frEventObjects41 2 } frEventObjects42 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.42 The circuit is now experiencing congestion in the inbound direction." ::= { frEventsGroup 42 } fr42-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.42" ::= { frEventObjects42 1 } fr42-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.42" ::= { frEventObjects42 2 } frEventObjects43 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.43 The address header on received management frame had BECN, FECN, DE or CR bits set." ::= { frEventsGroup 43 } fr43-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.43" ::= { frEventObjects43 1 } frEventObjects44 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.44 LMI Link Integrity Verification message was received from the network without the router polling for it." ::= { frEventsGroup 44 } fr44-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.44" ::= { frEventObjects44 1 } frEventObjects45 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.45 LMI Full Status message was received from the network without the router polling for it." ::= { frEventsGroup 45 } fr45-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.45" ::= { frEventObjects45 1 } frEventObjects46 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.46 A frame was received of a bridge type defined in RFC 1490. However, since bridging has not been enabled on this circuit, frame is being discarded." ::= { frEventsGroup 46 } fr46-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.46" ::= { frEventObjects46 1 } fr46-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.46" ::= { frEventObjects46 2 } frEventObjects47 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.47 A bridge frame is being discarded as a bridge port is not in forwarding state." ::= { frEventsGroup 47 } fr47-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.47" ::= { frEventObjects47 1 } fr47-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.47" ::= { frEventObjects47 2 } frEventObjects48 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.48 A bridged frame has been received and is being discarded due to mismatch in the frame type versus the bridge port behavior." ::= { frEventsGroup 48 } fr48-source-mac OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'source-mac' in event FR.48" ::= { frEventObjects48 1 } fr48-dest-mac OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'dest-mac' in event FR.48" ::= { frEventObjects48 2 } fr48-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.48" ::= { frEventObjects48 3 } fr48-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.48" ::= { frEventObjects48 4 } frEventObjects49 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.49 An unsupported bridge frame type has been encountered." ::= { frEventsGroup 49 } fr49-type OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'type' in event FR.49" ::= { frEventObjects49 1 } fr49-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.49" ::= { frEventObjects49 2 } fr49-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.49" ::= { frEventObjects49 3 } frEventObjects50 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.50 An unrecognized outgoing bridge frame type. Bridge has asked the Frame Relay interface to send out a frame whose type cannot be translated into encapsulation defined in RFC 1490." ::= { frEventsGroup 50 } fr50-type OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'type' in event FR.50" ::= { frEventObjects50 1 } fr50-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.50" ::= { frEventObjects50 2 } fr50-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.50" ::= { frEventObjects50 3 } frEventObjects51 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.51 A protocol frame has been discarded because it could not be queued for transmission." ::= { frEventsGroup 51 } fr51-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.51" ::= { frEventObjects51 1 } fr51-protocol OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'protocol' in event FR.51" ::= { frEventObjects51 2 } fr51-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.51" ::= { frEventObjects51 3 } frEventObjects52 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.52 An LMI send sequence number of 0 has been received." ::= { frEventsGroup 52 } fr52-sndseq OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'sndseq' in event FR.52" ::= { frEventObjects52 1 } fr52-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.52" ::= { frEventObjects52 2 } frEventObjects53 OBJECT-IDENTITY STATUS current DESCRIPTION "Event FR.53 A FRF.12 fragment is processed and a event is reported." ::= { frEventsGroup 53 } fr53-message OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'message' in event FR.53" ::= { frEventObjects53 1 } fr53-header OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'header' in event FR.53" ::= { frEventObjects53 2 } fr53-circuit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'circuit' in event FR.53" ::= { frEventObjects53 3 } fr53-size OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'size' in event FR.53" ::= { frEventObjects53 4 } fr53-ifcname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Parameter 'ifcname' in event FR.53" ::= { frEventObjects53 5 } frNotification1 NOTIFICATION-TYPE OBJECTS { fr1-circuit, fr1-protocol, fr1-size, fr1-ifcname, fr1-buffer } STATUS current DESCRIPTION "Notification of Event FR.1 Message: 'Frame received, PVC = $1 protocol type = $2 size $3 bytes, on interface $4HexadecimalData: $5' Parameters list: $1: fr1-circuit $2: fr1-protocol $3: fr1-size $4: fr1-ifcname $5: fr1-buffer A frame had been received on the FR interface." ::= { frNotificationsPrefix 1 } frNotification2 NOTIFICATION-TYPE OBJECTS { fr2-circuit, fr2-protocol, fr2-size, fr2-ifcname, fr2-buffer } STATUS current DESCRIPTION "Notification of Event FR.2 Message: 'Frame transmitted PVC = $1 protocol type = $2 size $3 bytes, on interface $4HexadecimalData: $5' Parameters list: $1: fr2-circuit $2: fr2-protocol $3: fr2-size $4: fr2-ifcname $5: fr2-buffer A frame had been transmitted on the FR interface." ::= { frNotificationsPrefix 2 } frNotification3 NOTIFICATION-TYPE OBJECTS { fr3-circuit, fr3-protocol, fr3-ifcname } STATUS current DESCRIPTION "Notification of Event FR.3 Message: 'Transmit frame discarded PVC = $1 protocol type = $2, on interface $3' Parameters list: $1: fr3-circuit $2: fr3-protocol $3: fr3-ifcname A protocol frame had been discarded due to the PVC congested condition." ::= { frNotificationsPrefix 3 } frNotification4 NOTIFICATION-TYPE OBJECTS { fr4-circuit, fr4-ifcname } STATUS current DESCRIPTION "Notification of Event FR.4 Message: 'Circuit outbound congestion PVC = $1, on interface $2' Parameters list: $1: fr4-circuit $2: fr4-ifcname The circuit is now experiencing congestion in the outbound direction." ::= { frNotificationsPrefix 4 } frNotification5 NOTIFICATION-TYPE OBJECTS { fr5-circuit, fr5-ifcname } STATUS current DESCRIPTION "Notification of Event FR.5 Message: 'Circuit outbound uncongested PVC = $1, on interface $2' Parameters list: $1: fr5-circuit $2: fr5-ifcname The circuit is now not experiencing congestion in the outbound direction." ::= { frNotificationsPrefix 5 } frNotification6 NOTIFICATION-TYPE OBJECTS { fr6-circuit, fr6-ifcname } STATUS current DESCRIPTION "Notification of Event FR.6 Message: 'Circuit enters active state PVC = $1, on interface $2' Parameters list: $1: fr6-circuit $2: fr6-ifcname The circuit enters the active state." ::= { frNotificationsPrefix 6 } frNotification7 NOTIFICATION-TYPE OBJECTS { fr7-circuit, fr7-ifcname } STATUS current DESCRIPTION "Notification of Event FR.7 Message: 'An orphan circuit not statically configured has joined the network PVC = $1, on interface $2' Parameters list: $1: fr7-circuit $2: fr7-ifcname The LMI signalled present and active a circuit which had not been statically configured." ::= { frNotificationsPrefix 7 } frNotification8 NOTIFICATION-TYPE OBJECTS { fr8-circuit, fr8-ifcname } STATUS current DESCRIPTION "Notification of Event FR.8 Message: 'Circuit enters inactive state PVC = $1, on interface $2' Parameters list: $1: fr8-circuit $2: fr8-ifcname The circuit enters the inactive state." ::= { frNotificationsPrefix 8 } frNotification9 NOTIFICATION-TYPE OBJECTS { fr9-circuit, fr9-ifcname } STATUS current DESCRIPTION "Notification of Event FR.9 Message: 'Circuit is unavailable PVC = $1, on interface $2' Parameters list: $1: fr9-circuit $2: fr9-ifcname The circuit is no longer available on the network." ::= { frNotificationsPrefix 9 } frNotification10 NOTIFICATION-TYPE OBJECTS { fr10-circuit, fr10-ifcname } STATUS current DESCRIPTION "Notification of Event FR.10 Message: 'Circuit is available PVC = $1, on interface $2' Parameters list: $1: fr10-circuit $2: fr10-ifcname The circuit is now available on the network." ::= { frNotificationsPrefix 10 } frNotification11 NOTIFICATION-TYPE OBJECTS { fr11-rcvseq, fr11-xmtseq, fr11-ifcname } STATUS current DESCRIPTION "Notification of Event FR.11 Message: 'LMI sequence number exchange requested, last received sequence = $1, current transmit sequence = $2, on interface $3' Parameters list: $1: fr11-rcvseq $2: fr11-xmtseq $3: fr11-ifcname A LMI sequence number exchange has been requested." ::= { frNotificationsPrefix 11 } frNotification12 NOTIFICATION-TYPE OBJECTS { fr12-ifcname } STATUS current DESCRIPTION "Notification of Event FR.12 Message: 'LMI Status Enquiry requested on interface $1' Parameters list: $1: fr12-ifcname A LMI full Status Enquiry has been requested." ::= { frNotificationsPrefix 12 } frNotification13 NOTIFICATION-TYPE OBJECTS { fr13-ifcname } STATUS current DESCRIPTION "Notification of Event FR.13 Message: 'LMI solicited Status Enquiry response had been received on interface $1' Parameters list: $1: fr13-ifcname A solicited LMI Status Enquiry response has been received." ::= { frNotificationsPrefix 13 } frNotification14 NOTIFICATION-TYPE OBJECTS { fr14-ifcname } STATUS current DESCRIPTION "Notification of Event FR.14 Message: 'LMI Full Status Enquiry response had been received on interface $1' Parameters list: $1: fr14-ifcname A LMI full Status Enquiry response has been received." ::= { frNotificationsPrefix 14 } frNotification15 NOTIFICATION-TYPE OBJECTS { fr15-dcd, fr15-cts, fr15-ifcname } STATUS current DESCRIPTION "Notification of Event FR.15 Message: 'Modem status changed DCD = $1 CTS = $2 on interface $3' Parameters list: $1: fr15-dcd $2: fr15-cts $3: fr15-ifcname A modem status change has occurred. The present state is described." ::= { frNotificationsPrefix 15 } frNotification16 NOTIFICATION-TYPE OBJECTS { fr16-circuit, fr16-protocol, fr16-ifcname } STATUS current DESCRIPTION "Notification of Event FR.16 Message: 'Multicast frame transmitted PVC = $1 protocol type = $2, on interface $3' Parameters list: $1: fr16-circuit $2: fr16-protocol $3: fr16-ifcname A multicast frame had been transmitted on the FR interface." ::= { frNotificationsPrefix 16 } frNotification17 NOTIFICATION-TYPE OBJECTS { fr17-circuit, fr17-ifcname } STATUS current DESCRIPTION "Notification of Event FR.17 Message: 'Circuit remains congested in the outbound direction PVC = $1, on interface $2' Parameters list: $1: fr17-circuit $2: fr17-ifcname The circuit is remaining in the outbound congested state toward the network." ::= { frNotificationsPrefix 17 } frNotification18 NOTIFICATION-TYPE OBJECTS { fr18-circuit, fr18-protocol, fr18-ifcname } STATUS current DESCRIPTION "Notification of Event FR.18 Message: 'CIR exceeded, transmit frame discarded PVC = $1 protocol type = $2, on interface $3' Parameters list: $1: fr18-circuit $2: fr18-protocol $3: fr18-ifcname A protocol frame had been discarded due to the PVC exceeding the CIR on the circuit." ::= { frNotificationsPrefix 18 } frNotification19 NOTIFICATION-TYPE OBJECTS { fr19-circuit, fr19-ifcname } STATUS current DESCRIPTION "Notification of Event FR.19 Message: 'A disallowed orphan circuit not statically configured has been ignored PVC = $1, on interface $2' Parameters list: $1: fr19-circuit $2: fr19-ifcname The LMI signalled present and active a circuit which had not been statically configured or allowed." ::= { frNotificationsPrefix 19 } frNotification20 NOTIFICATION-TYPE OBJECTS { fr20-circuit, fr20-ifcname } STATUS current DESCRIPTION "Notification of Event FR.20 Message: 'The total circuits allowed has been exceeded, an orphan circuit has been ignored PVC = $1, on interface $2' Parameters list: $1: fr20-circuit $2: fr20-ifcname The LMI signalled present and active a circuit which cannot join the interface, maximum circuits have been exceeded." ::= { frNotificationsPrefix 20 } frNotification21 NOTIFICATION-TYPE OBJECTS { fr21-circuit, fr21-ifcname } STATUS current DESCRIPTION "Notification of Event FR.21 Message: 'No available memory for orphan circuit, the circuit has been ignored PVC = $1, on interface $2' Parameters list: $1: fr21-circuit $2: fr21-ifcname The LMI signalled present and active a circuit which cannot join the interface, memory is unavailable." ::= { frNotificationsPrefix 21 } frNotification22 NOTIFICATION-TYPE OBJECTS { fr22-type, fr22-ifcname } STATUS current DESCRIPTION "Notification of Event FR.22 Message: 'Unsupported LMI information element, type = $1 on interface $2' Parameters list: $1: fr22-type $2: fr22-ifcname An unsupported management information element has been encountered." ::= { frNotificationsPrefix 22 } frNotification23 NOTIFICATION-TYPE OBJECTS { fr23-type, fr23-ifcname } STATUS current DESCRIPTION "Notification of Event FR.23 Message: 'Unsupported LMI message type, type encountered = $1, on interface $2' Parameters list: $1: fr23-type $2: fr23-ifcname An unsupported management message has been encountered." ::= { frNotificationsPrefix 23 } frNotification24 NOTIFICATION-TYPE OBJECTS { fr24-circuit, fr24-group, fr24-ifcname } STATUS current DESCRIPTION "Notification of Event FR.24 Message: 'A multicast circuit has joined the network PVC = $1, in multicast group = $2 on interface $3' Parameters list: $1: fr24-circuit $2: fr24-group $3: fr24-ifcname The LMI signalled present and active a multicast circuit." ::= { frNotificationsPrefix 24 } frNotification25 NOTIFICATION-TYPE OBJECTS { fr25-circuit, fr25-group, fr25-ifcname } STATUS current DESCRIPTION "Notification of Event FR.25 Message: 'An multicast circuit has left the network PVC = $1, from multicast group = $2 on interface $3' Parameters list: $1: fr25-circuit $2: fr25-group $3: fr25-ifcname The LMI signalled present and active a multicast circuit." ::= { frNotificationsPrefix 25 } frNotification26 NOTIFICATION-TYPE OBJECTS { fr26-type, fr26-circuit, fr26-size, fr26-ifcname } STATUS current DESCRIPTION "Notification of Event FR.26 Message: 'Unsupported Network Layer Protocol ID, type = $1 from PVC = $2 size $3 bytes on interface $4' Parameters list: $1: fr26-type $2: fr26-circuit $3: fr26-size $4: fr26-ifcname An unsupported network layer protocol NLPID has been encountered." ::= { frNotificationsPrefix 26 } frNotification27 NOTIFICATION-TYPE OBJECTS { fr27-type, fr27-circuit, fr27-size, fr27-ifcname } STATUS current DESCRIPTION "Notification of Event FR.27 Message: 'Unsupported ethernet type, type = $1 from PVC = $2 size $3 bytes on interface $4' Parameters list: $1: fr27-type $2: fr27-circuit $3: fr27-size $4: fr27-ifcname An unsupported Ethernet type has been encountered." ::= { frNotificationsPrefix 27 } frNotification28 NOTIFICATION-TYPE OBJECTS { fr28-circuit, fr28-group, fr28-ifcname } STATUS current DESCRIPTION "Notification of Event FR.28 Message: 'An unsupported multicast circuit has been ignored, PVC = $1, in multicast group = $2 on interface $3' Parameters list: $1: fr28-circuit $2: fr28-group $3: fr28-ifcname The LMI signalled present and active a multicast circuit that is not supported on the interface." ::= { frNotificationsPrefix 28 } frNotification29 NOTIFICATION-TYPE OBJECTS { fr29-circuit, fr29-ifcname } STATUS current DESCRIPTION "Notification of Event FR.29 Message: 'Data received on invalid or nonconfigured circuit, PVC = $1 on interface $2' Parameters list: $1: fr29-circuit $2: fr29-ifcname Data has been received on a circuit not configured or learned dynamically but not yet active on network." ::= { frNotificationsPrefix 29 } frNotification30 NOTIFICATION-TYPE OBJECTS { fr30-rcvseq, fr30-xmtseq, fr30-ifcname } STATUS current DESCRIPTION "Notification of Event FR.30 Message: 'LMI sequence number exchange received, last received sequence = $1 current transmit sequence = $2, on interface $3' Parameters list: $1: fr30-rcvseq $2: fr30-xmtseq $3: fr30-ifcname A LMI sequence number exchange has been received." ::= { frNotificationsPrefix 30 } frNotification31 NOTIFICATION-TYPE OBJECTS { fr31-ifcname } STATUS current DESCRIPTION "Notification of Event FR.31 Message: 'LMI unsolicited single Status Update had been received on interface $1' Parameters list: $1: fr31-ifcname An LMI unsolicited single status update message has been received." ::= { frNotificationsPrefix 31 } frNotification32 NOTIFICATION-TYPE OBJECTS { fr32-ifcname } STATUS current DESCRIPTION "Notification of Event FR.32 Message: 'Circuit address length less than the 2 octet minimum received on interface $1' Parameters list: $1: fr32-ifcname A frame containing less than the 2 octet minimum address length had been encountered." ::= { frNotificationsPrefix 32 } frNotification33 NOTIFICATION-TYPE OBJECTS { fr33-ifcname } STATUS current DESCRIPTION "Notification of Event FR.33 Message: 'Circuit address length greater than the 2 octet maximum received on interface $1' Parameters list: $1: fr33-ifcname A frame containing greater than the 2 octet maximum address length supported had been encountered. Currently, only 2 octet addressing is supported." ::= { frNotificationsPrefix 33 } frNotification34 NOTIFICATION-TYPE OBJECTS { fr34-circuit, fr34-ifcname } STATUS current DESCRIPTION "Notification of Event FR.34 Message: 'Circuit status update message contained a reserved management channel address, PVC = $1, on interface $2' Parameters list: $1: fr34-circuit $2: fr34-ifcname The LMI status message contained a reserved management channel address." ::= { frNotificationsPrefix 34 } frNotification35 NOTIFICATION-TYPE OBJECTS { fr35-type, fr35-circuit, fr35-ifcname } STATUS current DESCRIPTION "Notification of Event FR.35 Message: 'Unsupported Link Layer Control frame encountered, type = $1 from PVC = $2 on interface $3' Parameters list: $1: fr35-type $2: fr35-circuit $3: fr35-ifcname An unsupported link layer control frame encountered." ::= { frNotificationsPrefix 35 } frNotification36 NOTIFICATION-TYPE OBJECTS { fr36-type, fr36-ifcname } STATUS current DESCRIPTION "Notification of Event FR.36 Message: 'Unsupported layer management protocol descriptor encountered, type = $1 on interface $2' Parameters list: $1: fr36-type $2: fr36-ifcname An unsupported network layer protocol descriptor has been encountered." ::= { frNotificationsPrefix 36 } frNotification37 NOTIFICATION-TYPE OBJECTS { fr37-ifcname } STATUS current DESCRIPTION "Notification of Event FR.37 Message: 'Unsupported layer management call reference encountered on interface $1' Parameters list: $1: fr37-ifcname An unsupported network layer call reference field has been encountered." ::= { frNotificationsPrefix 37 } frNotification38 NOTIFICATION-TYPE OBJECTS { fr38-ifcname } STATUS current DESCRIPTION "Notification of Event FR.38 Message: 'No lock shift encountered in received ANSI LMI message on interface $1' Parameters list: $1: fr38-ifcname The received ANSI management frame did not include required locking shift information element." ::= { frNotificationsPrefix 38 } frNotification39 NOTIFICATION-TYPE OBJECTS { fr39-ifcname } STATUS current DESCRIPTION "Notification of Event FR.39 Message: 'Incorrect formated information element encountered on interface $1' Parameters list: $1: fr39-ifcname The received management frame information element was incorrectly formated." ::= { frNotificationsPrefix 39 } frNotification40 NOTIFICATION-TYPE OBJECTS { fr40-rcvseq, fr40-xmtseq, fr40-ifcname } STATUS current DESCRIPTION "Notification of Event FR.40 Message: 'LMI receive sequence number in error, receive sequence = $1 expected sequence = $2, on interface $3' Parameters list: $1: fr40-rcvseq $2: fr40-xmtseq $3: fr40-ifcname An incorrect LMI receive sequence number has been received." ::= { frNotificationsPrefix 40 } frNotification41 NOTIFICATION-TYPE OBJECTS { fr41-circuit, fr41-ifcname } STATUS current DESCRIPTION "Notification of Event FR.41 Message: 'An circuit has been removed from the network PVC = $1, on interface $2' Parameters list: $1: fr41-circuit $2: fr41-ifcname The LMI failed to signal the mentioned circuit is last network status update message. Circuit assumed removed from network." ::= { frNotificationsPrefix 41 } frNotification42 NOTIFICATION-TYPE OBJECTS { fr42-circuit, fr42-ifcname } STATUS current DESCRIPTION "Notification of Event FR.42 Message: 'Circuit inbound congestion PVC = $1, on interface $2' Parameters list: $1: fr42-circuit $2: fr42-ifcname The circuit is now experiencing congestion in the inbound direction." ::= { frNotificationsPrefix 42 } frNotification43 NOTIFICATION-TYPE OBJECTS { fr43-ifcname } STATUS current DESCRIPTION "Notification of Event FR.43 Message: 'Incorrect formatted address header for LMI packet encountered on interface $1' Parameters list: $1: fr43-ifcname The address header on received management frame had BECN, FECN, DE or CR bits set." ::= { frNotificationsPrefix 43 } frNotification44 NOTIFICATION-TYPE OBJECTS { fr44-ifcname } STATUS current DESCRIPTION "Notification of Event FR.44 Message: 'Unsolicited LMI Link Integrity Verification received on interface $1' Parameters list: $1: fr44-ifcname LMI Link Integrity Verification message was received from the network without the router polling for it." ::= { frNotificationsPrefix 44 } frNotification45 NOTIFICATION-TYPE OBJECTS { fr45-ifcname } STATUS current DESCRIPTION "Notification of Event FR.45 Message: 'Unsolicited LMI FULL STATUS response received on interface $1' Parameters list: $1: fr45-ifcname LMI Full Status message was received from the network without the router polling for it." ::= { frNotificationsPrefix 45 } frNotification46 NOTIFICATION-TYPE OBJECTS { fr46-circuit, fr46-ifcname } STATUS current DESCRIPTION "Notification of Event FR.46 Message: 'DROP: Bridging not enabled on PVC=$1, on interface $2' Parameters list: $1: fr46-circuit $2: fr46-ifcname A frame was received of a bridge type defined in RFC 1490. However, since bridging has not been enabled on this circuit, frame is being discarded." ::= { frNotificationsPrefix 46 } frNotification47 NOTIFICATION-TYPE OBJECTS { fr47-circuit, fr47-ifcname } STATUS current DESCRIPTION "Notification of Event FR.47 Message: 'DROP: Bridge port not forwarding on PVC=$1, on interface $2' Parameters list: $1: fr47-circuit $2: fr47-ifcname A bridge frame is being discarded as a bridge port is not in forwarding state." ::= { frNotificationsPrefix 47 } frNotification48 NOTIFICATION-TYPE OBJECTS { fr48-source-mac, fr48-dest-mac, fr48-circuit, fr48-ifcname } STATUS current DESCRIPTION "Notification of Event FR.48 Message: 'DROP: $1->$2, Frame to bridge port behavior mismatch on PVC=$3, on interface $4' Parameters list: $1: fr48-source-mac $2: fr48-dest-mac $3: fr48-circuit $4: fr48-ifcname A bridged frame has been received and is being discarded due to mismatch in the frame type versus the bridge port behavior." ::= { frNotificationsPrefix 48 } frNotification49 NOTIFICATION-TYPE OBJECTS { fr49-type, fr49-circuit, fr49-ifcname } STATUS current DESCRIPTION "Notification of Event FR.49 Message: 'Unsupported bridge frame type = $1 from PVC = $2 on interface $3' Parameters list: $1: fr49-type $2: fr49-circuit $3: fr49-ifcname An unsupported bridge frame type has been encountered." ::= { frNotificationsPrefix 49 } frNotification50 NOTIFICATION-TYPE OBJECTS { fr50-type, fr50-circuit, fr50-ifcname } STATUS current DESCRIPTION "Notification of Event FR.50 Message: 'Unrecognized outgoing bridge frame type = $1 on PVC = $2 on interface $3' Parameters list: $1: fr50-type $2: fr50-circuit $3: fr50-ifcname An unrecognized outgoing bridge frame type. Bridge has asked the Frame Relay interface to send out a frame whose type cannot be translated into encapsulation defined in RFC 1490." ::= { frNotificationsPrefix 50 } frNotification51 NOTIFICATION-TYPE OBJECTS { fr51-circuit, fr51-protocol, fr51-ifcname } STATUS current DESCRIPTION "Notification of Event FR.51 Message: 'Transmit frame discarded PVC = $1 protocol type = $2, on interface $3' Parameters list: $1: fr51-circuit $2: fr51-protocol $3: fr51-ifcname A protocol frame has been discarded because it could not be queued for transmission." ::= { frNotificationsPrefix 51 } frNotification52 NOTIFICATION-TYPE OBJECTS { fr52-sndseq, fr52-ifcname } STATUS current DESCRIPTION "Notification of Event FR.52 Message: 'LMI send sequence number in error, sequence = $1, on interface $2' Parameters list: $1: fr52-sndseq $2: fr52-ifcname An LMI send sequence number of 0 has been received." ::= { frNotificationsPrefix 52 } frNotification53 NOTIFICATION-TYPE OBJECTS { fr53-message, fr53-header, fr53-circuit, fr53-size, fr53-ifcname } STATUS current DESCRIPTION "Notification of Event FR.53 Message: 'FRF.12 $1 header $2 on PVC = $3 size $4 bytes, on interface $5' Parameters list: $1: fr53-message $2: fr53-header $3: fr53-circuit $4: fr53-size $5: fr53-ifcname A FRF.12 fragment is processed and a event is reported." ::= { frNotificationsPrefix 53 } END