| OID symbolic | OID numeric | Type | Access | Description |
| telProdNpMonInterfASL | 1.3.6.1.4.1.2007.4.1.2.2.2.16 | | | |
| telProdNpMonIfcASLGlobalTable | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1 | | not-accessible | This table contains general information about asynchronous serial line
interfaces. There will be one entry per each interface of this kind. |
| telProdNpMonIfcASLGlobalEntry | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1.1 | | not-accessible | Each entry contains the interface number that will be the table index
used to go over the table, the line speed, the throughput in bits per
second, the last throughput, the number of bits per character, the
number of stop bits, the parity chosen (if it exists), the number of
parity errors, data errors, overrun errors, the amount of time passed
since the last port reset and variables to indicate if the SCC loopback
mode or echo mode are active, if CD or DSR signal states are ignored and
if CD signal is disconnected from internal hardware. |
| INT telProdNpMonIfcASLGloIndex | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1.1.1 | INTEGER | read-only | Interface number. The interface must be asynchronous serial line.
It is the table index. |
| STR telProdNpMonIfcASLGloDriverType | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1.1.2 | DisplayString | read-only | Type of physical driverP: (1) DCE, (2) DTE. The variable is a string. |
| INT telProdNpMonIfcASLGloSpeed | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1.1.3 | INTEGER | read-only | Speed of the asynchronous serial line. (Clock speed, in bps). |
| INT telProdNpMonIfcASLGloThrou | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1.1.4 | INTEGER | read-only | Throughput in bits per second. It is the mean effective speed. |
| INT telProdNpMonIfcASLGloLastThrou | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1.1.5 | INTEGER | read-only | Last throughput, in bits per second. It is the mean instantaneous
speed. |
| INT telProdNpMonIfcASLGloBitsChar | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1.1.6 | INTEGER | read-only | Number of bits per character. |
| INT telProdNpMonIfcASLGloStopBits | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1.1.7 | INTEGER | read-only | Number of stop bits. |
| INT telProdNpMonIfcASLGloParitySel | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1.1.8 | INTEGER | read-only | Parity chosen (if parity has been chosen). The possible values are:
(0) if no parity has been selected, (1) odd, (2) space, (3) even,
(4) mark. |
| INT telProdNpMonIfcASLGloLastResetWeek | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1.1.9 | INTEGER | read-only | Weeks passed since the last port reset. |
| INT telProdNpMonIfcASLGloLastResetDay | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1.1.10 | INTEGER | read-only | Days passed since the last port reset: the remaining days that we get
after counting the number of weeks that are not enough to form a week,
this implies that the value of the variable must be under 7. |
| INT telProdNpMonIfcASLGloLastResetHour | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1.1.11 | INTEGER | read-only | Hours passed since the last reset of the port. If it has passed more
than a week, this variable indicates the number of hours to be added
to the number of weeks and days, and its value should be under 24 so
as not form a complete day. |
| INT telProdNpMonIfcASLGloLastResetMin | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1.1.12 | INTEGER | read-only | Minutes passed since the last reset of the port. This variable
indicates the number of minutes since the last hour was added to the
hour counter. |
| INT telProdNpMonIfcASLGloLastResetSec | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1.1.13 | INTEGER | read-only | Seconds passed since the last reset of the port. The total time passed
will be calculated by adding weeks, days, hours, minutes and seconds
since the last reset. |
| INT telProdNpMonIfcASLGloLoopback | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1.1.14 | INTEGER | read-only | This variable indicates if SCC loopback mode is active: transmitter is
connected internally to the receiver. |
| INT telProdNpMonIfcASLGloEcho | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1.1.15 | INTEGER | read-only | This variable indicates if SCC echo mode is active: transmitter
resends received data. |
| INT telProdNpMonIfcASLGloIgnoreCD | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1.1.16 | INTEGER | read-only | This variable indicates if CD signal state is ignored. |
| INT telProdNpMonIfcASLGloDisconnectCD | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1.1.17 | INTEGER | read-only | This variable indicates if CD signal is disconnected from internal
hardware. |
| INT telProdNpMonIfcASLGloIgnoreDSR | 1.3.6.1.4.1.2007.4.1.2.2.2.16.1.1.18 | INTEGER | read-only | This variable indicates if DSR signal state is ignored. |
| telProdNpMonIfcASLRS232Table | 1.3.6.1.4.1.2007.4.1.2.2.2.16.2 | | not-accessible | This table contains the signals or circuits RS232. It shows wether the
signals are active or not. The entry number is determined by the
interface number considered. |
| telProdNpMonIfcASLRS232Entry | 1.3.6.1.4.1.2007.4.1.2.2.2.16.2.1 | | not-accessible | Each entry contains the interface number of the node considered, which
will be the first index used to go over the table, the order number of
the circuit inside that interface (second index), which must be between
1 and a maximum value that depends on the conector type (the highest
value will be 7), the circuit number (105, 106, 107, 108, 109, 125,
141), its name (RTS, CTS, DSR, DTR, DCD, RI, LL) and wether it is
active or not. |
| INT telProdNpMonIfcASLRS232IfcIndex | 1.3.6.1.4.1.2007.4.1.2.2.2.16.2.1.1 | INTEGER | read-only | Interface number, which must be synchronous serial line. It is the
first table index. |
| INT telProdNpMonIfcASLRS232CircIndex | 1.3.6.1.4.1.2007.4.1.2.2.2.16.2.1.2 | INTEGER | read-only | Second table index. This value goes between 1 to the number of this
type of circuits, that varies depending on the conector type. |
| INT telProdNpMonIfcASLRS232Circuit | 1.3.6.1.4.1.2007.4.1.2.2.2.16.2.1.3 | INTEGER | read-only | RS232 circuit number. The possible values are 105, 106, 107, 108,
109, 125 y 141. |
| STR telProdNpMonIfcASLRS232Nickname | 1.3.6.1.4.1.2007.4.1.2.2.2.16.2.1.4 | DisplayString | read-only | Circuit name. |
| STR telProdNpMonIfcASLRS232State | 1.3.6.1.4.1.2007.4.1.2.2.2.16.2.1.5 | DisplayString | read-only | Signal state (circuit signals): on, off or unknown. |
| telProdNpMonIfcASLStatsTable | 1.3.6.1.4.1.2007.4.1.2.2.2.16.3 | | not-accessible | This table contains statistics of asynchronous serial line interfaces. |
| telProdNpMonIfcASLStatsEntry | 1.3.6.1.4.1.2007.4.1.2.2.2.16.3.1 | | not-accessible | Each entry contains the interface number that is the table index, the
variable that shows the output from the last table deletion operation
(in get operations) or begins the deletion (in set operations), the
number of parity errors, the number of data errors and the number of
overrun errors. |
| INT telProdNpMonIfcASLStatsIndex | 1.3.6.1.4.1.2007.4.1.2.2.2.16.3.1.1 | INTEGER | read-only | Interface number. The interface must be asynchronous serial line to
appear in the table. It is the table index. |
| INT telProdNpMonIfcASLStatsClear | 1.3.6.1.4.1.2007.4.1.2.2.2.16.3.1.2 | INTEGER | read-write | This variable when is read shows the output from the last table delete
attempt: the value is 2 if the deletion was performed succesfully, 3 if
an error ocurred and 4 for an undefined result, that means that nobody
has tried to delete the table yet. In set operations, the value 1 (it is
the only value that can be assigned by a writing operation) causes a
table deletion: frame counters are set to 0. |
| CTR telProdNpMonIfcASLStatsParityErr | 1.3.6.1.4.1.2007.4.1.2.2.2.16.3.1.3 | Counter | read-only | Number of parity errors. |
| CTR telProdNpMonIfcASLStatsDataErr | 1.3.6.1.4.1.2007.4.1.2.2.2.16.3.1.4 | Counter | read-only | Number of data errors. |
| CTR telProdNpMonIfcASLStatsOverrun | 1.3.6.1.4.1.2007.4.1.2.2.2.16.3.1.5 | Counter | read-only | Number of overrun errors. |