| OID symbolic | OID numeric | Type | Access | Description |
| telProdNpMonInterfSSL | 1.3.6.1.4.1.2007.4.1.2.2.2.15 | | | |
| telProdNpMonIfcSSLGlobalTable | 1.3.6.1.4.1.2007.4.1.2.2.2.15.1 | | not-accessible | This table contains general information about synchronous serial line
interfaces. The interface number determines the entry number. |
| telProdNpMonIfcSSLGlobalEntry | 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1 | | not-accessible | Each table entry contains the interface number of the related node,
which is the index used to go over the table, the type of physical
driver (DTE or DCE), the line speed, the time when the last port
reset ocurred and variables to indicate if the SCC loopback mode or
echo mode are active and if the DTE driver uses internal clocks. |
| INT telProdNpMonIfcSSLGloIndex | 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.1 | INTEGER | read-only | The node interface number, which indicates the corresponding table
entry (it is the table index). |
| STR telProdNpMonIfcSSLGloDriverType | 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.2 | DisplayString | read-only | Type of physical driver: (1) DCE, (2) DTE. This variable is a string
that indicates the driver. |
| INT telProdNpMonIfcSSLGloLineSpeed | 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.3 | INTEGER | read-only | Line speed, in bits per second. The value 0 indicates speed unknown. |
| INT telProdNpMonIfcSSLGloLastResetWeek | 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.4 | INTEGER | read-only | Weeks passed since the last reset of the port. |
| INT telProdNpMonIfcSSLGloLastResetDay | 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.5 | INTEGER | read-only | Days passed since the last reset of the port: the remaining days that
we get after counting the number of weeks that are not enough to form
a week, this implies that the value of the variable must be under 7. |
| INT telProdNpMonIfcSSLGloLastResetHour | 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.6 | INTEGER | read-only | Hours passed since the last reset of the port. If it has passed more
than a week, this variable indicates the number of hours to be added to
the number of weeks and days, and its value should be under 24 so as not
form a complete day. |
| INT telProdNpMonIfcSSLGloLastResetMin | 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.7 | INTEGER | read-only | Minutes passed since the last reset of the port. This variable
indicates the number of minutes since the last hour added to the hour
counter. |
| INT telProdNpMonIfcSSLGloLastResetSec | 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.8 | INTEGER | read-only | Seconds passed since the last reset of the port. The total time passed
will be calculated by adding weeks, days, hours, minutes and seconds
since the last reset. |
| INT telProdNpMonIfcSSLGloLoopback | 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.9 | INTEGER | read-only | This variable indicates if SCC loopback mode is active: transmitter is
connected internally to the receiver. |
| INT telProdNpMonIfcSSLGloEcho | 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.10 | INTEGER | read-only | This variable indicates if SCC echo mode is active: transmitter
resends received data. |
| INT telProdNpMonIfcSSLGloDTEIntClocks | 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.11 | INTEGER | read-only | This variable indicates if DTE driver uses internal clocks. |
| INT telProdNpMonIfcSSLGloIgnoreCD | 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.12 | INTEGER | read-only | This variable indicates if CD signal state is ignored. |
| INT telProdNpMonIfcSSLGloDisconnectCD | 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.13 | INTEGER | read-only | This variable indicates if CD signal is disconnected from internal
hardware. |
| INT telProdNpMonIfcSSLGloIgnoreCTS | 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.14 | INTEGER | read-only | This variable indicates if CTS signal state is ignored. |
| INT telProdNpMonIfcSSLGloIgnoreDSR | 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.15 | INTEGER | read-only | This variable indicates if DSR signal state is ignored. |
| telProdNpMonIfcSSLRS232Table | 1.3.6.1.4.1.2007.4.1.2.2.2.15.2 | | not-accessible | This table contains the signals or circuits RS232. It shows wether the
signals are active or not. The entry number is determined by the
interface number considered. |
| telProdNpMonIfcSSLRS232Entry | 1.3.6.1.4.1.2007.4.1.2.2.2.15.2.1 | | not-accessible | Each entry contains the interface number of the node considered, which
will be the first index used to go over the table, the order number of
the circuit inside that interface (second index), which must be between
1 and a maximum value that depends on the conector type (the highest
value will be 7), the circuit number (105, 106, 107, 108, 109, 125,
141), its name (RTS, CTS, DSR, DTR, DCD, RI, LL) and wether it is active
or not. |
| INT telProdNpMonIfcSSLRS232IfcIndex | 1.3.6.1.4.1.2007.4.1.2.2.2.15.2.1.1 | INTEGER | read-only | Synchronous serial line interface number of the node. It is the first
table index. |
| INT telProdNpMonIfcSSLRS232CircIndex | 1.3.6.1.4.1.2007.4.1.2.2.2.15.2.1.2 | INTEGER | read-only | Second table index. This number goes from 1 to the number of circuits
of this type allowed, which varies with the conector type. |
| INT telProdNpMonIfcSSLRS232Circuit | 1.3.6.1.4.1.2007.4.1.2.2.2.15.2.1.3 | INTEGER | read-only | RS232 circuit number. Values accepted are 105, 106, 107, 108, 109,
125 y 141. |
| STR telProdNpMonIfcSSLRS232Nickname | 1.3.6.1.4.1.2007.4.1.2.2.2.15.2.1.4 | DisplayString | read-only | Circuit name. |
| STR telProdNpMonIfcSSLRS232State | 1.3.6.1.4.1.2007.4.1.2.2.2.15.2.1.5 | DisplayString | read-only | State of (circuit) signals: on, off or unknown. |
| telProdNpMonIfcSSLFramesTable | 1.3.6.1.4.1.2007.4.1.2.2.2.15.3 | | not-accessible | This table contains a counter of outgoing frames and a counter of bugs
in ingoing frames. The entry number is determined by the interface
number (table index). |
| telProdNpMonIfcSSLFramesEntry | 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1 | | not-accessible | Each entry contains the node interface number, which is the index used
to go over the table, a variable that shows the last output obtained
when the user tried to delete the table (get operations) or performs
the deletion (set operations), CRC errors in incoming frames, alignment
errors, lost incoming frames due to overrun, too long frames, aborted
frames, number of errors due to DMA/FIFO overrun, number of DMA/FIFO
underrun in outgoing frames and aborted outputs sent. |
| INT telProdNpMonIfcSSLFramesIndex | 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.1 | INTEGER | read-only | Interface number of the node, that shows the corresponding table entry
(it is the index). |
| INT telProdNpMonIfcSSLFramesClear | 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.2 | INTEGER | read-write | This variable when is read shows the output from the last table delete
attempt: the value is 2 if the deletion was performed succesfully, 3 if
an error ocurred and 4 for an undefined result, that means that nobody
has tried to delete the table yet. In set operations, the value 1 (it is
the only value that can be assigned by a writing operation) causes a
table deletion: frame counters are set to 0. |
| CTR telProdNpMonIfcSSLFramesCRCError | 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.3 | Counter | read-only | Number of frames with CRC errors. |
| CTR telProdNpMonIfcSSLFramesAlignment | 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.4 | Counter | read-only | Number of incoming frames with alignment errors. |
| CTR telProdNpMonIfcSSLFramesMissed | 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.5 | Counter | read-only | Number of incoming frames lost due to overrun. |
| CTR telProdNpMonIfcSSLFramesTooLong | 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.6 | Counter | read-only | Number of incoming frames too long. |
| CTR telProdNpMonIfcSSLFramesAborted | 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.7 | Counter | read-only | Number of incoming frames aborted. |
| CTR telProdNpMonIfcSSLFramesOverrun | 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.8 | Counter | read-only | Number of DMA/FIFO overrun. |
| CTR telProdNpMonIfcSSLFramesUnderrun | 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.9 | Counter | read-only | Number of DMA/FIFO underrun. |
| CTR telProdNpMonIfcSSLFramesTxAbort | 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.10 | Counter | read-only | Number of aborted outputs sent. |