| OID symbolic | OID numeric | Type | Access | Description |
| slEdfa | 1.3.6.1.4.1.4515.1.9 | | | This MIB module describes the EDFA Cards |
| edfaConfig | 1.3.6.1.4.1.4515.1.9.1 | | | |
| edfaConfigTable | 1.3.6.1.4.1.4515.1.9.1.1 | | not-accessible | The EDFA configuration table. |
| edfaConfigEntry | 1.3.6.1.4.1.4515.1.9.1.1.1 | | not-accessible | An entry in the EDFA interface configuration table.
The index to this table is the same as the
an ifIndex. |
| NUM edfaIfIndex | 1.3.6.1.4.1.4515.1.9.1.1.1.1 | InterfaceIndex | read-only | The amplifier interface index. |
| I32 edfaPumpTempEx | 1.3.6.1.4.1.4515.1.9.1.1.1.2 | Integer32 | read-only | The pump temperture (in Kelvin). |
| INT edfaRxPower | 1.3.6.1.4.1.4515.1.9.1.1.1.3 | INTEGER | read-only | The measured Rx Power.
The value is specified in ten'th of Dbm units increments, starting
from -30.0 dbm (e.g. value 0 means -30.0 dbm). |
| INT edfaPumpAdminStatus | 1.3.6.1.4.1.4515.1.9.1.1.1.4 | INTEGER | read-write | The desired state of the laser. The restart(3)
state indicates that the edfa pump should be restarted.
The restart(3) is not a state, thus it is not kept
in the configuration file. |
| INT edfaPumpOperStatus | 1.3.6.1.4.1.4515.1.9.1.1.1.5 | INTEGER | read-only | The current operational state of the laser.
If edfaPumpAdminStatus is down(2) then
edfaPumpOperStatus should be down(2).
If edfaPumpAdminStatus is changed to up(1) then
edfaPumpOperStatus should change to
up(1) if the interface is ready to transmit and
receive network traffic; it should remain in the down(2) state if
and only if there is a fault that prevents it from
going to the up(1) state.
The operational status is equal to restart(3) if the edfa pump
is still in restart process. |
| INT edfaStatus | 1.3.6.1.4.1.4515.1.9.1.1.1.6 | INTEGER | read-only | This variable indicates the Line Status of the
Edfa module.
The edfaStatus is a bit map represented as a
sum, therefore, it can represent multiple failures (alarms)
simultaneously.
edfaNoAlarm must be set if and only if no other
flag is set.
The various bit positions are:
1 edfaNoAlarm No alarm present
2 edfaPumpTemperuture Pump temperatur is out-of-bound
4 edfaPumpWavelength Pump wavelength is out-of-bound
8 edfaHwFail Pump HW failure
16 edfaRvcSignalDetect Loss of input signal
32 edfaPumpPower Pump power is out-of-bound
64 edfaRcvPower Rx Power is out-of-bound
128 edfaTemprature Edfa temperature is out-of-bound
256 edfaEyeSafty Eye safety alarm (available only in eye-safety mode)
512 edafGainFlatness Gain flatness alarm
1024 edfaXmtPower Tx Power is out-of-bound
2048 edfaGain Edfa Gain is out-of-bound
4096 edfaEol Pump End Of Life |
| INT edfaVoa | 1.3.6.1.4.1.4515.1.9.1.1.1.7 | INTEGER | read-only | The computed VOA output attenuation specified in
0.1 dB units. From 0.0 to +15.0 dB. |
| T/F edfaAutomaticMode | 1.3.6.1.4.1.4515.1.9.1.1.1.8 | TruthValue | read-write | Defines the Edfa automatic mode. If equals TRUE,
the Edfa control mode should selected automaticaly.
Otherwise it should be selected manualy. |
| INT edfaAdminControlMode | 1.3.6.1.4.1.4515.1.9.1.1.1.9 | INTEGER | read-write | Configure the Edfa control mode. This object
may be set only when edfaAtomaticMode is FALSE. |
| INT edfaOperControlMode | 1.3.6.1.4.1.4515.1.9.1.1.1.10 | INTEGER | read-only | The current Edfa control mode. Initialy the Edfa
starts in APC mode. The AGC mode is used only when
selected manualy or after transient input power change. |
| INT edfaAdminGain | 1.3.6.1.4.1.4515.1.9.1.1.1.11 | INTEGER | read-write | The required Edfa Gain value given in 0.1 dB units. This value
may be configured only when the edfa automatic mode is FALSE
and the edfa control mode is Agc. |
| INT edfaOperGain | 1.3.6.1.4.1.4515.1.9.1.1.1.12 | INTEGER | read-only | The actual Edfa Gain value given in 0.1 dB units.
Value range starts with 0.0 dbm |
| INT edfaAdminOutputPower | 1.3.6.1.4.1.4515.1.9.1.1.1.13 | INTEGER | read-write | The required Edfa output power value given in 0.1 dBm units.
The range starts with -30.0 dBm. This value
may be configured only when the edfa control mode is Apc. |
| INT edfaOperOutputPower | 1.3.6.1.4.1.4515.1.9.1.1.1.14 | INTEGER | read-only | The actual Edfa total output power value specified in 0.1 dBm units.
Valid valuse are in the range of 0.0 dBm upto +15.0 dBm. |
| INT edfaChannelsNumber | 1.3.6.1.4.1.4515.1.9.1.1.1.15 | INTEGER | read-only | The number of optical channels on this signal. |
| INT edfaTotalChannelsNumber | 1.3.6.1.4.1.4515.1.9.1.1.1.16 | INTEGER | read-only | The total number of optical channels on this fiber. |
| T/F edfaEyeSafetyMode | 1.3.6.1.4.1.4515.1.9.1.1.1.17 | TruthValue | read-write | When in Eye-Safety mode the edfa reduces the laser
power budget down to safe level upon detection of an
output fiber cut. |
| T/F edfaShutDownLipEnable | 1.3.6.1.4.1.4515.1.9.1.1.1.18 | TruthValue | read-write | EDFA shout-down on LIP (Loss of signal) -
enable/disable. |
| T/F edfaAutoPowerUpLipEnable | 1.3.6.1.4.1.4515.1.9.1.1.1.19 | TruthValue | read-write | EDFA automatic power up (after signal returns) -
enable/disable. |
| INT edfaMaxGain | 1.3.6.1.4.1.4515.1.9.1.1.1.20 | INTEGER | read-only | The EDFA max gain is determined by the result of the VER command.
Legal values:
gainUnknown(1)
gain14dbm(2) - Booster/Inline, (-2)-14dBm output power, gain (-5)-22dB
gain17dbm(3) - Booster/Inline, (-2)-17dBm output power, gain (-5)-22dB
gain20dbm(4) - Booster/Inline, (-2)-20dBm output power, gain (-5)-22dB
gain23dbm(5) - Booster/Inline, 5-23dBm output power, gain (-5)-22dB, 16 channels
gain18dbmPreAmp8Ch(6) - Preamp (-18)-5dBm output power, fixed gain 18dB
gain18dbmPreAmp16ChRed(7) - Preamp (-18)-5dBm output power, fixed gain 18dB
gain18dbmPreAmp16ChBlue(8)- Preamp (-18)-0dBm output power, fixed gain 18dB
gain23dbmGain10(9) - Booster/Inline, 23dBm output power with fixed gain of 10dB, 32 channels |
| INT edfaGainInFrom | 1.3.6.1.4.1.4515.1.9.1.1.1.21 | INTEGER | read-only | Lower input gain range of the edfa in units of 0.1 db. |
| INT edfaGainInTo | 1.3.6.1.4.1.4515.1.9.1.1.1.22 | INTEGER | read-only | Upper input gain range of the edfa in units of 0.1 db. |
| INT edfaGainOutFrom | 1.3.6.1.4.1.4515.1.9.1.1.1.23 | INTEGER | read-only | Lower output gain range of the edfa in units of 0.1 db. |
| INT edfaGainOutTo | 1.3.6.1.4.1.4515.1.9.1.1.1.24 | INTEGER | read-only | Upper output gain range of the edfa in units of 0.1 db. |
| INT edfaPowerInFrom | 1.3.6.1.4.1.4515.1.9.1.1.1.25 | INTEGER | read-only | Lower input power range of the edfa in units of 0.1 dbm. |
| INT edfaPowerInTo | 1.3.6.1.4.1.4515.1.9.1.1.1.26 | INTEGER | read-only | Upper input power range of the edfa in units of 0.1 dbm. |
| INT edfaPowerOutFrom | 1.3.6.1.4.1.4515.1.9.1.1.1.27 | INTEGER | read-only | Lower output power range of the edfa in units of 0.1 dbm. |
| INT edfaPowerOutTo | 1.3.6.1.4.1.4515.1.9.1.1.1.28 | INTEGER | read-only | Upper output power range of the edfa in units of 0.1 dbm. |
| INT edfaFromChannel | 1.3.6.1.4.1.4515.1.9.1.1.1.29 | INTEGER | read-only | The first channel number supported by the edfa; 0 to ignore. |
| INT edfaToChannel | 1.3.6.1.4.1.4515.1.9.1.1.1.30 | INTEGER | read-only | The last channel number supported by the edfa; 0 to ignore. |
| INT edfaOscChannel | 1.3.6.1.4.1.4515.1.9.1.1.1.31 | INTEGER | read-only | The wavelenght of the optical supervisory channel e.g. 1510, 1490. |
| INT edfaRedBlueType | 1.3.6.1.4.1.4515.1.9.1.1.1.32 | INTEGER | read-only | The type of the edaf. |
| INT edfaRole | 1.3.6.1.4.1.4515.1.9.1.1.1.33 | INTEGER | read-only | The role of the edaf. |
| STR edfaFreeDescription | 1.3.6.1.4.1.4515.1.9.1.1.1.34 | DisplayString | read-only | A free text with additional edfa information. |
| INT edfaConfigSafetyThreshold | 1.3.6.1.4.1.4515.1.9.1.1.1.35 | INTEGER | read-write | The Eye Safety threshold level specified in dBm units.
The value given in 0.1 dBm units. The range starts with -50.0 dBm. |
| INT edfaSigOutputPower | 1.3.6.1.4.1.4515.1.9.1.1.1.36 | INTEGER | read-only | The measured Signal output Power.
The value is specified in ten'th of Dbm units increments, starting
from -30.0 dbm (e.g. value 0 means -30.0 dbm). |
| edfaTraps | 1.3.6.1.4.1.4515.1.9.2 | | | |
| edfaTraps0 | 1.3.6.1.4.1.4515.1.9.2.0 | | | |
| NTF edfaStatusChange0 | 1.3.6.1.4.1.4515.1.9.2.0.1 | | | A edfaStatusChange trap is sent when the
value of an instance edfaStatus changes. It
can be utilized by an NMS to trigger polls.
It is defined to support browsers that don't recognize RFC 2576. |
| NTF edfaControlModeChange0 | 1.3.6.1.4.1.4515.1.9.2.0.2 | | | A edfaControlModeChange trap is sent when the
value of an instance edfaOperControlMode when going
from APC to AGC (both directions) in automatic mode.
It is defined to support browsers that don't recognize RFC 2576. |
| NTF edfaStatusChange | 1.3.6.1.4.1.4515.1.9.2.1 | | | A edfaStatusChange trap is sent when the
value of an instance edfaStatus changes. It
can be utilized by an NMS to trigger polls. |
| NTF edfaControlModeChange | 1.3.6.1.4.1.4515.1.9.2.2 | | | A edfaControlModeChange trap is sent when the
value of an instance edfaOperControlMode when going
from APC to AGC (both directions) in automatic mode. |