All MIBs › SL-EDFA-MIB › edfaRxPower
edfaRxPower
Module: SL-EDFA-MIB
OID (symbolic): SL-EDFA-MIB::edfaRxPower
OID (numeric): 1.3.6.1.4.1.4515.1.9.1.1.1.3
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The measured Rx Power. The value is specified in ten'th of Dbm units increments, starting from -30.0 dbm (e.g. value 0 means -30.0 dbm).
What is edfaRxPower?
The measured optical receive power, in tenths of a dBm starting at -30.0 dBm (so a raw value of 0 means -30.0 dBm), used to confirm enough light is arriving at the amplifier input.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4515.1.9.1.1.1.3 snmpwalk -v2c -c public <target> SL-EDFA-MIB::edfaRxPower
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.4515.1.9.1.1.1.3.1 snmpget -v2c -c public <target> SL-EDFA-MIB::edfaRxPower.1
Start monitoring Smartoptics SiteLight optical transport platform, EDFA card (pump temperature/power/status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SL-EDFA-MIB::edfaRxPower OID value, configure state conditions and alerts, and monitor any Smartoptics SiteLight optical transport platform, EDFA card (pump temperature/power/status) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.4515 | smartoptics | SL-NE-MIB |
| 1.3.6.1.4.1.4515.1 | sitelight | SL-NE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.4515.1.9 | slEdfa | SL-EDFA-MIB |
| 1.3.6.1.4.1.4515.1.9.1 | edfaConfig | SL-EDFA-MIB |
| 1.3.6.1.4.1.4515.1.9.1.1 | edfaConfigTable | SL-EDFA-MIB |
| 1.3.6.1.4.1.4515.1.9.1.1.1 | edfaConfigEntry | SL-EDFA-MIB |
| 1.3.6.1.4.1.4515.1.9.1.1.1.3 | edfaRxPower | SL-EDFA-MIB |