| OID symbolic | OID numeric | Type | Access | Description |
| STR sieStAgentBuild | 1.3.6.1.4.1.231.2.10.2.11.1.4 | DisplayString | read-only | Build time and date of agent program implementation |
| STR sieStAgentCompany | 1.3.6.1.4.1.231.2.10.2.11.1.2 | DisplayString | read-only | Agent company name |
| STR sieStAgentId | 1.3.6.1.4.1.231.2.10.2.11.1.1 | DisplayString | read-only | Agent identification string |
| sieStAgentInfo | 1.3.6.1.4.1.231.2.10.2.11.1 | | | |
| sieStAgentParameters | 1.3.6.1.4.1.231.2.10.2.11.5 | | | |
| STR sieStAgentType | 1.3.6.1.4.1.231.2.10.2.11.5.1 | DisplayString | read-only | Type of agent (i.e. 'Desktop' or 'Server').
This field can be used to launch the correct management front end
application (DeskView or ServerView) in enterprise management systems. |
| STR sieStAgentVersionString | 1.3.6.1.4.1.231.2.10.2.11.1.3 | DisplayString | read-only | Agent version string . (i.e. 1.05) |
| sieStatusAgent | 1.3.6.1.4.1.231.2.10.2.11 | | | |
| INT sieStComponentConfirmFailure | 1.3.6.1.4.1.231.2.10.2.11.4.1.1.6 | INTEGER | read-write | Confirm a failure status of a component that does not automatically
reset its status (e.g. BIOS selftest error). The error condition is
removed after the failure has been confirmed.
GET values: 0 - no failure to confirm; SET not possible
>0 - component failure; SET a zero value to confirm
SET values: 0 - confirm failure and remove error condition
(setting other values than 0 is not possible) |
| STR sieStComponentDisplayName | 1.3.6.1.4.1.231.2.10.2.11.4.1.1.5 | DisplayString | read-only | Component display name string. |
| STR sieStComponentLastErrorMessage | 1.3.6.1.4.1.231.2.10.2.11.4.1.1.4 | DisplayString | read-only | Error message text of the current component. Empty string,
if no error has happened since reboot. This object is not supported by
all components and can therefore be empty although an error happened. |
| STR sieStComponentName | 1.3.6.1.4.1.231.2.10.2.11.4.1.1.2 | DisplayString | read-only | Component name/tag. This name identifies the component and will never
be changed if once defined. This name is a string like 'SvEnvironment',
'SvVoltages', 'OemUpsAPC' etc. |
| INT sieStComponentNumber | 1.3.6.1.4.1.231.2.10.2.11.4.1.1.1 | INTEGER | read-only | Component number (index, 1..n) |
| sieStComponents | 1.3.6.1.4.1.231.2.10.2.11.4.1.1 | | not-accessible | |
| sieStComponentStatus | 1.3.6.1.4.1.231.2.10.2.11.4 | | | |
| INT sieStComponentStatusValue | 1.3.6.1.4.1.231.2.10.2.11.4.1.1.3 | INTEGER | read-only | Component status value:
ok(1): component is working properly
degraded(2): redundant component has failed or signals a warning
error(3): severe problem, system may no longer work properly
failed(4): this value is obsolete - will no longer appear
unknown(5): component had no valid status (initialization, no instances)
notPresent(6): component is not present (e.g. empty socket)
notManageable(7): component is not manageable |
| sieStComponentTable | 1.3.6.1.4.1.231.2.10.2.11.4.1 | | not-accessible | Table containing the monitored components |
| INT sieStNumberComponents | 1.3.6.1.4.1.231.2.10.2.11.4.2 | INTEGER | read-only | Number of available components; this is the number of entries in the component table |
| INT sieStNumberSubsystems | 1.3.6.1.4.1.231.2.10.2.11.3.2 | INTEGER | read-only | Number of available subsystems; this is the number of entries in the subsystem table |
| STR sieStSubsystemComponents | 1.3.6.1.4.1.231.2.10.2.11.3.1.1.5 | DisplayString | read-only | List if components (short names) included in this subsystem, separated
by blank spaces; e.g. 'SvPowerSupply OemUpsAPC' |
| STR sieStSubsystemDisplayName | 1.3.6.1.4.1.231.2.10.2.11.3.1.1.6 | DisplayString | read-only | Subsystem display name string. |
| STR sieStSubsystemLastErrorMessage | 1.3.6.1.4.1.231.2.10.2.11.3.1.1.4 | DisplayString | read-only | Error message text of the component that has failed last. Empty string,
if no error has happened since reboot. This object is not supported by
all components and can therefore be empty although an error happened. |
| STR sieStSubsystemList | 1.3.6.1.4.1.231.2.10.2.11.2.3 | DisplayString | read-only | List if subsystems included in this system, separated
by blank spaces. E.g. 'Environment PowerSupply MassStorage' |
| STR sieStSubsystemName | 1.3.6.1.4.1.231.2.10.2.11.3.1.1.2 | DisplayString | read-only | Subsystem name. This name identifies the subsystem and will never
be changed if once defined. This name is a string like 'Environment',
'PowerSupply', 'MassStorage' etc. |
| INT sieStSubsystemNumber | 1.3.6.1.4.1.231.2.10.2.11.3.1.1.1 | INTEGER | read-only | Subsystem number (index, 1..n) |
| sieStSubsystems | 1.3.6.1.4.1.231.2.10.2.11.3.1.1 | | not-accessible | |
| sieStSubsystemStatus | 1.3.6.1.4.1.231.2.10.2.11.3 | | | |
| INT sieStSubsystemStatusValue | 1.3.6.1.4.1.231.2.10.2.11.3.1.1.3 | INTEGER | read-only | Subsystem status value:
ok(1): all components in this subsystem working properly
degraded(2): redundant components failed or signal a warning
error(3): severe problem, system may no longer work properly
failed(4): this value is obsolete - will no longer appear
unknown(5): none of the components had a valid status (initialization, no components) |
| sieStSubsystemTable | 1.3.6.1.4.1.231.2.10.2.11.3.1 | | not-accessible | Table containing the monitored subsystems |
| INT sieStSystemIdentify | 1.3.6.1.4.1.231.2.10.2.11.2.4 | INTEGER | read-write | Sets the signal IDENTIFY for the system:
off(1): clear the identify signal / signal is off
on(2): set the IDENTIFY signal
not-available(3): identify signal ist not available (this value cannot be set)
blinking(4): IDENTIFY LED blinking, used for different purposes
Setting IDENTIFY by the ServerView application normally sets a LED
to have the possibility to identify a system selected by ServerView. |
| STR sieStSystemLastErrorMessage | 1.3.6.1.4.1.231.2.10.2.11.2.2 | DisplayString | read-only | Error message text of the component that has failed last. Empty string,
if no error has happened since reboot. This object is not supported by
all components and can therefore be empty although an error happened. |
| sieStSystemStatus | 1.3.6.1.4.1.231.2.10.2.11.2 | | | |
| INT sieStSystemStatusValue | 1.3.6.1.4.1.231.2.10.2.11.2.1 | INTEGER | read-only | Overall status of this system:
ok(1): all subsystems and components working properly, no failure
degraded(2): redundant components failed or signal a warning
error(3): severe problem, system may no longer work properly
failed(4): this value is obsolete - will no longer appear
unknown(5): none of the subsystems had a valid status (e.g. during initialization) |
| sieStTrapParameters | 1.3.6.1.4.1.231.2.10.2.11.10 | | | |
| STR sieStTrapParamServerName | 1.3.6.1.4.1.231.2.10.2.11.10.1 | DisplayString | not-accessible | Name of server the trap occured at |
| INT sieStTrapParamTimestamp | 1.3.6.1.4.1.231.2.10.2.11.10.2 | INTEGER | not-accessible | Time the trap occured (in seconds since 01/01/1970 00:00h) |
| NTF sieStTrapStatusChanged | 1.3.6.1.4.1.231.2.10.2.0.1100 | | | System status has changed. |
| sni | 1.3.6.1.4.1.231 | | | |
| sniBios | 1.3.6.1.4.1.231.2.10.2.2.1 | | | |
| sniBus | 1.3.6.1.4.1.231.2.10.2.2.4 | | | |
| sniCommon | 1.3.6.1.4.1.231.2.10.2.2 | | | |
| sniEisa | 1.3.6.1.4.1.231.2.10.2.2.2 | | | |
| sniExtensions | 1.3.6.1.4.1.231.2.10 | | | |
| sniHd | 1.3.6.1.4.1.231.2.10.2.2.3 | | | |
| sniInventory | 1.3.6.1.4.1.231.2.10.2.1 | | | |
| sniMlxDiskArray | 1.3.6.1.4.1.231.2.10.2.6.2.1 | | | |
| sniNetware | 1.3.6.1.4.1.231.2.10.2.5.1 | | | |
| sniOemComponents | 1.3.6.1.4.1.231.2.10.2.6 | | | |
| sniOemDpt | 1.3.6.1.4.1.231.2.10.2.6.1 | | | |
| sniOemMylex | 1.3.6.1.4.1.231.2.10.2.6.2 | | | |
| sniOs2 | 1.3.6.1.4.1.231.2.10.2.5.3 | | | |
| sniOsSpecific | 1.3.6.1.4.1.231.2.10.2.5 | | | |
| sniPcSpecific | 1.3.6.1.4.1.231.2.10.2.3 | | | |
| sniProductMibs | 1.3.6.1.4.1.231.2 | | | |
| sniScb | 1.3.6.1.4.1.231.2.10.2.4 | | | |
| sniSecurity | 1.3.6.1.4.1.231.2.10.2.7 | | | |
| sniServerControl | 1.3.6.1.4.1.231.2.10.2.2.5 | | | |
| sniServerMgmt | 1.3.6.1.4.1.231.2.10.2 | | | |
| sniServerView | 1.3.6.1.4.1.231.2.10.2.8 | | | |
| sniSmSecurity | 1.3.6.1.4.1.231.2.10.2.7.1 | | | |
| sniTrapMib | 1.3.6.1.4.1.231.2.10.5 | | | |
| sniUnix | 1.3.6.1.4.1.231.2.10.2.5.4 | | | |
| sniWinNt | 1.3.6.1.4.1.231.2.10.2.5.2 | | | |