All MIBs › SDX-ROOT-MIB
Organization: Citrix Systems, Inc.
Last Updated: 2013-12-05
Category: Citrix Application Delivery, Enterprise SMI and Registration
Description:
Defines the Citrix SDX enterprise root OID tree hierarchy for appliance MIB registration.
Imported Objects
From INET-ADDRESS-MIB
| InetAddress | |
| InetAddressType |
From IPV6-TC
| Ipv6Address |
From SNMPv2-SMI
| Counter32 | |
| Gauge32 | |
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-IDENTITY | |
| OBJECT-TYPE | |
| TimeTicks | |
| enterprises |
What Is SDX-ROOT-MIB?
SDX-ROOT-MIB is the enterprise root MIB for Citrix's NetScaler SDX (Service Delivery appliance) platform, defining the top-level OID tree and core system identification objects for the SDX management hypervisor layer. It exposes platform and product identity (systemPlatform, systemProduct, systemBuildNumber) as well as networking configuration for the SDX management components, including the SVM (management service VM) and Xen hypervisor IP addressing, netmask, and gateway settings. Its monitoring value centers on software/platform status and management-plane connectivity: confirming the correct build/version is running and that the SVM and Xen management interfaces are correctly addressed and reachable, which is foundational before deeper per-instance NetScaler VPX monitoring can occur. It serves as the root registration point for other SDX-specific MIB branches (such as sdxEventGroup for event/notification data) and depends on the standard SNMPv2-SMI enterprises arc. It is deployed on Citrix (NetScaler) SDX multi-tenant application delivery appliances that host multiple NetScaler VPX instances, and administrators typically perform an SDX-ROOT-MIB download from Citrix to load the module into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in SDX-ROOT-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
What Can Be Monitored
- platform/product identity and build version
- SVM management IP configuration
- Xen hypervisor IP configuration
- netmask and gateway settings
- SDX event/notification registration
Supported Devices
- Citrix (NetScaler) SDX multi-tenant application delivery appliances
Monitoring Examples
An administrator would poll systemProduct and systemBuildNumber to confirm the SDX appliance's software version, then check systemSvmIPAddress and systemXenIPAddress against systemNetmask and systemGateway to verify the management plane's networking is correctly configured. A mismatch or unreachable systemSvmIPAddress would indicate the SDX management service VM has a networking problem, which would block visibility into the hosted NetScaler VPX instances.
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| netScaler | 1.3.6.1.4.1.5951 | The enterprise specific MIB for Netscaler NS10.0. | ||
| sdxRoot | 1.3.6.1.4.1.5951.6 | |||
| sdxEventGroup | 1.3.6.1.4.1.5951.6.1 | |||
| eventVarBindOids | 1.3.6.1.4.1.5951.6.1.1 | |||
| OCT source | 1.3.6.1.4.1.5951.6.1.1.1 | OCTET STRING | accessible-for-notify | IP address of the device generating the event |
| OCT entityName | 1.3.6.1.4.1.5951.6.1.1.2 | OCTET STRING | accessible-for-notify | Name of the entity associated with this alarm |
| OCT entityType | 1.3.6.1.4.1.5951.6.1.1.3 | OCTET STRING | accessible-for-notify | Type of entity associated with this alarm |
| OCT eventMessage | 1.3.6.1.4.1.5951.6.1.1.4 | OCTET STRING | accessible-for-notify | Message associated with this alarm |
| OCT thresholdValue | 1.3.6.1.4.1.5951.6.1.1.5 | OCTET STRING | accessible-for-notify | High threshold value configured for this alarm |
| OCT currentValue | 1.3.6.1.4.1.5951.6.1.1.6 | OCTET STRING | accessible-for-notify | Current value of the entity when high or normal threshold trap is sent |
| OCT severity | 1.3.6.1.4.1.5951.6.1.1.7 | OCTET STRING | accessible-for-notify | Severity associated with this alarm |
| sdxEvents | 1.3.6.1.4.1.5951.6.1.2 | |||
| NTF cpuUsageHigh | 1.3.6.1.4.1.5951.6.1.2.1 | CPU utilization has exceeded the high threshold value | ||
| NTF cpuUsageNormal | 1.3.6.1.4.1.5951.6.1.2.2 | CPU utilization has returned to normal | ||
| NTF memoryUsageHigh | 1.3.6.1.4.1.5951.6.1.2.3 | Memory utilization has exceeded the high threshold value. On SDX platform since memory for an instance is decided by the administrator, this trap is not raised | ||
| NTF memoryUsageNormal | 1.3.6.1.4.1.5951.6.1.2.4 | Memory utilization has returned to normal | ||
| NTF xenHttpFailed | 1.3.6.1.4.1.5951.6.1.2.5 | HTTP communication between the Management Service and XenServer has failed | ||
| NTF xenHttpNormal | 1.3.6.1.4.1.5951.6.1.2.6 | HTTP communication between the Management Service and XenServer has returned to normal | ||
| NTF xenSshFailed | 1.3.6.1.4.1.5951.6.1.2.7 | SSH communication between the Management Service and XenServer has failed | ||
| NTF xenSshNormal | 1.3.6.1.4.1.5951.6.1.2.8 | SSH communication between the Management Service and XenServer has returned to normal | ||
| NTF xenApiFailed | 1.3.6.1.4.1.5951.6.1.2.9 | XenAPI communication between the Management Service and XenServer has failed | ||
| NTF xenApiNormal | 1.3.6.1.4.1.5951.6.1.2.10 | XenAPI communication between the Management Service and XenServer has returned to normal | ||
| NTF xenPingFailed | 1.3.6.1.4.1.5951.6.1.2.11 | ICMP Ping between the Management Service and XenServer has failed | ||
| NTF xenPingNormal | 1.3.6.1.4.1.5951.6.1.2.12 | ICMP Ping between the Management Service and XenServer has returned to normal | ||
| NTF ipmiStateError | 1.3.6.1.4.1.5951.6.1.2.13 | Intelligent Platform Management Interface (IPMI) utility is missing | ||
| NTF ipmiStateNormal | 1.3.6.1.4.1.5951.6.1.2.14 | Intelligent Platform Management Interface (IPMI) utility is detected | ||
| NTF bmcFirmwareVersionError | 1.3.6.1.4.1.5951.6.1.2.15 | BMC firmware is missing or the version is not supported | ||
| NTF bmcFirmwareVersionNormal | 1.3.6.1.4.1.5951.6.1.2.16 | BMC firmware is detected or the version has returned to a supported version | ||
| NTF resourceStateError | 1.3.6.1.4.1.5951.6.1.2.17 | A hardware or software resource error has occurred; entityName and eventMessage show specific failure information | ||
| NTF resourceStateNormal | 1.3.6.1.4.1.5951.6.1.2.18 | The hardware or software resource error has been fixed and normal state has been restored; entityName and eventMessage show details | ||
| NTF fanSpeedError | 1.3.6.1.4.1.5951.6.1.2.19 | Fan speed is either high or low | ||
| NTF fanSpeedNormal | 1.3.6.1.4.1.5951.6.1.2.20 | Fan speed has returned to normal | ||
| NTF cpuTempError | 1.3.6.1.4.1.5951.6.1.2.21 | CPU temperature error; entityName and eventMessage show specific failure information | ||
| NTF cpuTempNormal | 1.3.6.1.4.1.5951.6.1.2.22 | CPU temperature has returned to normal | ||
| NTF systemTempError | 1.3.6.1.4.1.5951.6.1.2.23 | System temperature error; entityName and eventMessage show specific failure information | ||
| NTF systemTempNormal | 1.3.6.1.4.1.5951.6.1.2.24 | System temperature has returned to normal | ||
| NTF voltageError | 1.3.6.1.4.1.5951.6.1.2.25 | Voltage error; entityName and eventMessage show specific failure information | ||
| NTF voltageNormal | 1.3.6.1.4.1.5951.6.1.2.26 | Voltage has returned to normal | ||
| NTF powerSupplyFailed | 1.3.6.1.4.1.5951.6.1.2.27 | Power Supply error; entityName and eventMessage show specific failure information information | ||
| NTF powerSupplyNormal | 1.3.6.1.4.1.5951.6.1.2.28 | Power Supply has returned to normal condition | ||
| NTF healthCounterError | 1.3.6.1.4.1.5951.6.1.2.31 | Health Counter Error; entityName and eventMessage show specific failure information | ||
| NTF healthCounterNormal | 1.3.6.1.4.1.5951.6.1.2.32 | Health Counter Error condition has returned to normal; entityName and eventMessage show details | ||
| NTF interfaceDown | 1.3.6.1.4.1.5951.6.1.2.33 | A network interface has gone down; entityName and eventMessage show details | ||
| NTF interfaceUp | 1.3.6.1.4.1.5951.6.1.2.34 | The network interface has returned to UP state; entityName and eventMessage show details | ||
| NTF cpuAffinityRecoveryFailed | 1.3.6.1.4.1.5951.6.1.2.41 | CPU affinity recovery has failed | ||
| NTF cpuAffinityRecoverySuccess | 1.3.6.1.4.1.5951.6.1.2.42 | CPU affinity recovery is successful | ||
| NTF subSystemDown | 1.3.6.1.4.1.5951.6.1.2.43 | A subsystem has gone DOWN; entityName shows details | ||
| NTF subSystemUp | 1.3.6.1.4.1.5951.6.1.2.44 | A subsystem has returned to the UP state; entityName shows details | ||
| NTF subSystemFailed | 1.3.6.1.4.1.5951.6.1.2.45 | A subsystem has failed; entityName shows details | ||
| NTF mpsDown | 1.3.6.1.4.1.5951.6.1.2.46 | All subsystems are DOWN | ||
| NTF mpsUp | 1.3.6.1.4.1.5951.6.1.2.47 | All subsystems are UP | ||
| NTF passwordRecoveryFailed | 1.3.6.1.4.1.5951.6.1.2.48 | Password recovery has failed | ||
| NTF passwordRecoverySuccess | 1.3.6.1.4.1.5951.6.1.2.49 | Password has been recovered successfully | ||
| NTF deviceAdded | 1.3.6.1.4.1.5951.6.1.2.50 | A managed device has been added | ||
| NTF deviceRemoved | 1.3.6.1.4.1.5951.6.1.2.51 | A managed device has been removed | ||
| NTF deviceModified | 1.3.6.1.4.1.5951.6.1.2.52 | An attribute of a managed device has been changed | ||
| NTF devicePowerStateChanged | 1.3.6.1.4.1.5951.6.1.2.53 | Power state of a managed device has changed | ||
| NTF deviceStateChanged | 1.3.6.1.4.1.5951.6.1.2.54 | Instance state of a managed device has changed | ||
| NTF deviceBootFailed | 1.3.6.1.4.1.5951.6.1.2.55 | A managed device has failed to start | ||
| NTF deviceRebootFailed | 1.3.6.1.4.1.5951.6.1.2.56 | A managed device has failed to restart | ||
| NTF loginFailure | 1.3.6.1.4.1.5951.6.1.2.71 | This trap is sent when User Authentication fails. 'entityName' and 'eventMessage' will show specific failure information | ||
| NTF inventoryFailed | 1.3.6.1.4.1.5951.6.1.2.72 | XenServer inventory collection has failed | ||
| NTF healthMonitorPluginError | 1.3.6.1.4.1.5951.6.1.2.73 | This trap is sent when health monitor plugin (xsnsmonitor) is not installed on XenServer | ||
| NTF healthMonitorPluginNormal | 1.3.6.1.4.1.5951.6.1.2.74 | This trap is sent when health monitor plugin (xsnsmonitor) is back to installed state on XenServer | ||
| NTF versionMatrixMisMatch | 1.3.6.1.4.1.5951.6.1.2.75 | This trap is sent when version matrix mismatch is detected | ||
| NTF logicalDriveFailed | 1.3.6.1.4.1.5951.6.1.2.76 | Logical Drive Failed | ||
| NTF physicalDriveFailed | 1.3.6.1.4.1.5951.6.1.2.77 | Physical Drive Failed | ||
| NTF trapConfigFailure | 1.3.6.1.4.1.5951.6.1.2.78 | This trap is sent when failure occurs in adding snmp trap destination | ||
| systemGroup | 1.3.6.1.4.1.5951.6.2 | |||
| OCT systemPlatform | 1.3.6.1.4.1.5951.6.2.1 | OCTET STRING | read-only | Platform |
| OCT systemProduct | 1.3.6.1.4.1.5951.6.2.2 | OCTET STRING | read-only | Product Name |
| OCT systemBuildNumber | 1.3.6.1.4.1.5951.6.2.3 | OCTET STRING | read-only | Build Number |
| IPt systemSvmIPAddressType | 1.3.6.1.4.1.5951.6.2.4 | InetAddressType | read-only | Type of systemSvmIPAddress |
| IP systemSvmIPAddress | 1.3.6.1.4.1.5951.6.2.5 | InetAddress | read-only | Management Service IP Address |
| IPt systemXenIPAddressType | 1.3.6.1.4.1.5951.6.2.6 | InetAddressType | read-only | Type of systemXenIPAddress |
| IP systemXenIPAddress | 1.3.6.1.4.1.5951.6.2.7 | InetAddress | read-only | XenServer IP Address |
| IPt systemNetmaskType | 1.3.6.1.4.1.5951.6.2.8 | InetAddressType | read-only | Type of systemNetmask |
| IP systemNetmask | 1.3.6.1.4.1.5951.6.2.9 | InetAddress | read-only | Netmask |
| IPt systemGatewayType | 1.3.6.1.4.1.5951.6.2.10 | InetAddressType | read-only | Type of systemGateway |
| IP systemGateway | 1.3.6.1.4.1.5951.6.2.11 | InetAddress | read-only | Gateway |
| OCT systemNetworkInterface | 1.3.6.1.4.1.5951.6.2.12 | OCTET STRING | read-only | Interface on which management needs to be enabled |
| IPt systemDnsType | 1.3.6.1.4.1.5951.6.2.13 | InetAddressType | read-only | Type of systemDns |
| IP systemDns | 1.3.6.1.4.1.5951.6.2.14 | InetAddress | read-only | DNS Server |
| OCT systemSysId | 1.3.6.1.4.1.5951.6.2.15 | OCTET STRING | read-only | System Id |
| OCT systemSerial | 1.3.6.1.4.1.5951.6.2.16 | OCTET STRING | read-only | Serial Number |
| I32 systemCurrentTime | 1.3.6.1.4.1.5951.6.2.17 | Integer32 | read-only | Current Time |
| OCT systemUptime | 1.3.6.1.4.1.5951.6.2.18 | OCTET STRING | read-only | Uptime |
| OCT systemBiosVersion | 1.3.6.1.4.1.5951.6.2.19 | OCTET STRING | read-only | BIOS Version |
| OCT systemMaxThroughput | 1.3.6.1.4.1.5951.6.2.20 | OCTET STRING | read-only | Maximum Throughput in Mbps |
| OCT systemAvailableThroughput | 1.3.6.1.4.1.5951.6.2.21 | OCTET STRING | read-only | Available Throughput in Mbps |
| OCT systemHostId | 1.3.6.1.4.1.5951.6.2.22 | OCTET STRING | read-only | Host Id |
| sysHealthGroup | 1.3.6.1.4.1.5951.6.2.1000 | |||
| hardwareResourceTable | 1.3.6.1.4.1.5951.6.2.1000.1 | not-accessible | The SDX hardwareResourcetable | |
| hardwareResourceEntry | 1.3.6.1.4.1.5951.6.2.1000.1.1 | not-accessible | ... | |
| OCT hardwareResourceName | 1.3.6.1.4.1.5951.6.2.1000.1.1.1 | OCTET STRING | read-only | Resource name |
| IPt hardwareResourceHostIPAddressType | 1.3.6.1.4.1.5951.6.2.1000.1.1.2 | InetAddressType | read-only | Type of hardwareResourceHostIPAddress |
| IP hardwareResourceHostIPAddress | 1.3.6.1.4.1.5951.6.2.1000.1.1.3 | InetAddress | read-only | Host IP Address |
| OCT hardwareResourceCurrentValue | 1.3.6.1.4.1.5951.6.2.1000.1.1.4 | OCTET STRING | read-only | Current value of the resource |
| OCT hardwareResourceExpectedValue | 1.3.6.1.4.1.5951.6.2.1000.1.1.5 | OCTET STRING | read-only | Expected value of the resource |
| OCT hardwareResourceUnit | 1.3.6.1.4.1.5951.6.2.1000.1.1.6 | OCTET STRING | read-only | Measurement unit for the resource |
| OCT hardwareResourceStatus | 1.3.6.1.4.1.5951.6.2.1000.1.1.7 | OCTET STRING | read-only | Health status of the resource - OK/ERROR |
| softwareResourceTable | 1.3.6.1.4.1.5951.6.2.1000.2 | not-accessible | The SDX softwareResourcetable | |
| softwareResourceEntry | 1.3.6.1.4.1.5951.6.2.1000.2.1 | not-accessible | ... | |
| OCT softwareResourceName | 1.3.6.1.4.1.5951.6.2.1000.2.1.1 | OCTET STRING | read-only | Resource name |
| IPt softwareResourceHostIPAddressType | 1.3.6.1.4.1.5951.6.2.1000.2.1.2 | InetAddressType | read-only | Type of softwareResourceHostIPAddress |
| IP softwareResourceHostIPAddress | 1.3.6.1.4.1.5951.6.2.1000.2.1.3 | InetAddress | read-only | Host IP Address |
| OCT softwareResourceCurrentValue | 1.3.6.1.4.1.5951.6.2.1000.2.1.4 | OCTET STRING | read-only | Current value of the resource |
| OCT softwareResourceExpectedValue | 1.3.6.1.4.1.5951.6.2.1000.2.1.5 | OCTET STRING | read-only | Expected value of the resource |
| OCT softwareResourceUnit | 1.3.6.1.4.1.5951.6.2.1000.2.1.6 | OCTET STRING | read-only | Measurement unit for the resource |
| OCT softwareResourceStatus | 1.3.6.1.4.1.5951.6.2.1000.2.1.7 | OCTET STRING | read-only | Health status of the resource - OK/ERROR |
| diskTable | 1.3.6.1.4.1.5951.6.2.1000.3 | not-accessible | The SDX disktable | |
| diskEntry | 1.3.6.1.4.1.5951.6.2.1000.3.1 | not-accessible | ... | |
| OCT diskName | 1.3.6.1.4.1.5951.6.2.1000.3.1.1 | OCTET STRING | read-only | Name of the Disk |
| IPt diskHostIPAddressType | 1.3.6.1.4.1.5951.6.2.1000.3.1.2 | InetAddressType | read-only | Type of diskHostIPAddress |
| IP diskHostIPAddress | 1.3.6.1.4.1.5951.6.2.1000.3.1.3 | InetAddress | read-only | Host IP Address |
| OCT diskTransactionRate | 1.3.6.1.4.1.5951.6.2.1000.3.1.4 | OCTET STRING | read-only | Transactions per second |
| OCT diskBlockReadRate | 1.3.6.1.4.1.5951.6.2.1000.3.1.5 | OCTET STRING | read-only | Blocks read per second |
| OCT diskBlockWriteRate | 1.3.6.1.4.1.5951.6.2.1000.3.1.6 | OCTET STRING | read-only | Blocks written per second |
| OCT diskTotalBlocksRead | 1.3.6.1.4.1.5951.6.2.1000.3.1.7 | OCTET STRING | read-only | Total blocks read |
| OCT diskTotalBlocksWritten | 1.3.6.1.4.1.5951.6.2.1000.3.1.8 | OCTET STRING | read-only | Total blocks written |
| OCT diskUtilized | 1.3.6.1.4.1.5951.6.2.1000.3.1.9 | OCTET STRING | read-only | Utilization of the disk (bytes) |
| OCT diskSize | 1.3.6.1.4.1.5951.6.2.1000.3.1.10 | OCTET STRING | read-only | Size of the disk (bytes) |
| I32 diskBayNumber | 1.3.6.1.4.1.5951.6.2.1000.3.1.11 | Integer32 | read-only | Bay number |
| srTable | 1.3.6.1.4.1.5951.6.2.1000.4 | not-accessible | The SDX srtable | |
| srEntry | 1.3.6.1.4.1.5951.6.2.1000.4.1 | not-accessible | ... | |
| OCT srName | 1.3.6.1.4.1.5951.6.2.1000.4.1.1 | OCTET STRING | read-only | Name of the storage repository |
| OCT srBayNumber | 1.3.6.1.4.1.5951.6.2.1000.4.1.2 | OCTET STRING | read-only | Bay number |
| IPt srHostIPAddressType | 1.3.6.1.4.1.5951.6.2.1000.4.1.3 | InetAddressType | read-only | Type of srHostIPAddress |
| IP srHostIPAddress | 1.3.6.1.4.1.5951.6.2.1000.4.1.4 | InetAddress | read-only | Host IP Address |
| OCT srUtilized | 1.3.6.1.4.1.5951.6.2.1000.4.1.5 | OCTET STRING | read-only | Physical utilization of the storage repository |
| OCT srSize | 1.3.6.1.4.1.5951.6.2.1000.4.1.6 | OCTET STRING | read-only | Physical size of the storage repository |
| OCT srStatus | 1.3.6.1.4.1.5951.6.2.1000.4.1.7 | OCTET STRING | read-only | Status of the storage repository - OK/ERROR |
| interfaceTable | 1.3.6.1.4.1.5951.6.2.1000.5 | not-accessible | The SDX interfacetable | |
| interfaceEntry | 1.3.6.1.4.1.5951.6.2.1000.5.1 | not-accessible | ... | |
| OCT interfacePort | 1.3.6.1.4.1.5951.6.2.1000.5.1.1 | OCTET STRING | read-only | Port Name Ex: 10/1 |
| IPt interfaceHostIPAddressType | 1.3.6.1.4.1.5951.6.2.1000.5.1.2 | InetAddressType | read-only | Type of interfaceHostIPAddress |
| IP interfaceHostIPAddress | 1.3.6.1.4.1.5951.6.2.1000.5.1.3 | InetAddress | read-only | Host IP Address |
| OCT interfaceState | 1.3.6.1.4.1.5951.6.2.1000.5.1.4 | OCTET STRING | read-only | State of the Interface - UP/DOWN |
| OCT interfaceRxPackets | 1.3.6.1.4.1.5951.6.2.1000.5.1.5 | OCTET STRING | read-only | Received packets |
| OCT interfaceTxPackets | 1.3.6.1.4.1.5951.6.2.1000.5.1.6 | OCTET STRING | read-only | Transmitted packets |
| OCT interfaceRxBytes | 1.3.6.1.4.1.5951.6.2.1000.5.1.7 | OCTET STRING | read-only | Received bytes |
| OCT interfaceTxBytes | 1.3.6.1.4.1.5951.6.2.1000.5.1.8 | OCTET STRING | read-only | Transmitted bytes |
| OCT interfaceRxErrors | 1.3.6.1.4.1.5951.6.2.1000.5.1.9 | OCTET STRING | read-only | Receiving errors |
| OCT interfaceTxErrors | 1.3.6.1.4.1.5951.6.2.1000.5.1.10 | OCTET STRING | read-only | Transmission errors |
| I32 interfaceVfTotal | 1.3.6.1.4.1.5951.6.2.1000.5.1.11 | Integer32 | read-only | Total Virtual Functions |
| I32 interfaceVfAssigned | 1.3.6.1.4.1.5951.6.2.1000.5.1.12 | Integer32 | read-only | Assigned Virtual Functions |
| OCT interfaceMappedPort | 1.3.6.1.4.1.5951.6.2.1000.5.1.13 | OCTET STRING | read-only | Mapped Port Name Ex: eth0 |
| deviceGroup | 1.3.6.1.4.1.5951.6.3 | |||
| xenTable | 1.3.6.1.4.1.5951.6.3.1 | not-accessible | The SDX xentable | |
| xenEntry | 1.3.6.1.4.1.5951.6.3.1.1 | not-accessible | ... | |
| IPt xenIpAddressType | 1.3.6.1.4.1.5951.6.3.1.1.1 | InetAddressType | read-only | Type of xenIpAddress |
| IP xenIpAddress | 1.3.6.1.4.1.5951.6.3.1.1.2 | InetAddress | read-only | IP Address for this managed device |
| OCT xenHostname | 1.3.6.1.4.1.5951.6.3.1.1.3 | OCTET STRING | read-only | Assign hostname to managed device, if this is not provided, name will be set as host name |
| OCT xenDescription | 1.3.6.1.4.1.5951.6.3.1.1.4 | OCTET STRING | read-only | Description of managed device |
| OCT xenVersion | 1.3.6.1.4.1.5951.6.3.1.1.5 | OCTET STRING | read-only | Device Version |
| OCT xenUuid | 1.3.6.1.4.1.5951.6.3.1.1.6 | OCTET STRING | read-only | UUID of host |
| I32 xenNumberOfCPU | 1.3.6.1.4.1.5951.6.3.1.1.7 | Integer32 | read-only | Number of total CPU of host |
| OCT xenCpuUsage | 1.3.6.1.4.1.5951.6.3.1.1.8 | OCTET STRING | read-only | CPU Usage (%) of host |
| OCT xenMemoryTotal | 1.3.6.1.4.1.5951.6.3.1.1.9 | OCTET STRING | read-only | Total memory of host in MB |
| OCT xenMemoryFree | 1.3.6.1.4.1.5951.6.3.1.1.10 | OCTET STRING | read-only | Free memory available (MB) in host |
| OCT xenMemoryUsage | 1.3.6.1.4.1.5951.6.3.1.1.11 | OCTET STRING | read-only | Memory Usage (%) of host |
| OCT xenTx | 1.3.6.1.4.1.5951.6.3.1.1.12 | OCTET STRING | read-only | Out Throughput (Mbps) of host |
| OCT xenRx | 1.3.6.1.4.1.5951.6.3.1.1.13 | OCTET STRING | read-only | In Throughput (Mbps) of host |
| OCT xenUptime | 1.3.6.1.4.1.5951.6.3.1.1.14 | OCTET STRING | read-only | Uptime of host |
| I32 xenSslCoresTotal | 1.3.6.1.4.1.5951.6.3.1.1.15 | Integer32 | read-only | Total SSL Cores available in host |
| OCT xenIscsiIQN | 1.3.6.1.4.1.5951.6.3.1.1.16 | OCTET STRING | read-only | iSCSI IQN |
| OCT xenEdition | 1.3.6.1.4.1.5951.6.3.1.1.17 | OCTET STRING | read-only | XenServer Edition |
| OCT xenExpiry | 1.3.6.1.4.1.5951.6.3.1.1.18 | OCTET STRING | read-only | XenServer Expiry |
| OCT xenProductCode | 1.3.6.1.4.1.5951.6.3.1.1.19 | OCTET STRING | read-only | XenServer Product Code |
| OCT xenSerialNumber | 1.3.6.1.4.1.5951.6.3.1.1.20 | OCTET STRING | read-only | Device Serial Number |
| OCT xenVersionLong | 1.3.6.1.4.1.5951.6.3.1.1.21 | OCTET STRING | read-only | XenServer Version (full text) |
| OCT xenVersionShort | 1.3.6.1.4.1.5951.6.3.1.1.22 | OCTET STRING | read-only | XenServer Version |
| OCT xenBuildNumber | 1.3.6.1.4.1.5951.6.3.1.1.23 | OCTET STRING | read-only | XenServer Build Number |
| OCT xenBuildDate | 1.3.6.1.4.1.5951.6.3.1.1.24 | OCTET STRING | read-only | XenServer Build Date |
| netscalerTable | 1.3.6.1.4.1.5951.6.3.2 | not-accessible | The SDX netscalertable | |
| netscalerEntry | 1.3.6.1.4.1.5951.6.3.2.1 | not-accessible | ... | |
| IPt nsIpAddressType | 1.3.6.1.4.1.5951.6.3.2.1.1 | InetAddressType | read-only | Type of nsIpAddress |
| IP nsIpAddress | 1.3.6.1.4.1.5951.6.3.2.1.2 | InetAddress | read-only | IP Address for this managed device |
| IPt nsHostIPAddressType | 1.3.6.1.4.1.5951.6.3.2.1.3 | InetAddressType | read-only | Type of nsHostIPAddress |
| IP nsHostIPAddress | 1.3.6.1.4.1.5951.6.3.2.1.4 | InetAddress | read-only | Host IPAddress where VM is provisioned |
| OCT nsProfileName | 1.3.6.1.4.1.5951.6.3.2.1.5 | OCTET STRING | read-only | Device Profile Name that is attached with this managed device |
| OCT nsName | 1.3.6.1.4.1.5951.6.3.2.1.6 | OCTET STRING | read-only | Name of managed device |
| IPt nsNetmaskType | 1.3.6.1.4.1.5951.6.3.2.1.7 | InetAddressType | read-only | Type of nsNetmask |
| IP nsNetmask | 1.3.6.1.4.1.5951.6.3.2.1.8 | InetAddress | read-only | Netmask of managed device |
| IPt nsGatewayType | 1.3.6.1.4.1.5951.6.3.2.1.9 | InetAddressType | read-only | Type of nsGateway |
| IP nsGateway | 1.3.6.1.4.1.5951.6.3.2.1.10 | InetAddress | read-only | Default Gateway of managed device |
| OCT nsHostname | 1.3.6.1.4.1.5951.6.3.2.1.11 | OCTET STRING | read-only | Assign hostname to managed device, if this is not provided, name will be set as host name |
| OCT nsDescription | 1.3.6.1.4.1.5951.6.3.2.1.12 | OCTET STRING | read-only | Description of managed device |
| OCT nsVersion | 1.3.6.1.4.1.5951.6.3.2.1.13 | OCTET STRING | read-only | Device Version |
| OCT nsUuid | 1.3.6.1.4.1.5951.6.3.2.1.14 | OCTET STRING | read-only | UUID of VM Instance |
| OCT nsInstanceState | 1.3.6.1.4.1.5951.6.3.2.1.15 | OCTET STRING | read-only | State of device, UP only if device accessible |
| OCT nsVirtualFunctions | 1.3.6.1.4.1.5951.6.3.2.1.16 | OCTET STRING | read-only | Virtual Functions assigned to VM Instance |
| OCT nsSslVirtualFunctions | 1.3.6.1.4.1.5951.6.3.2.1.17 | OCTET STRING | read-only | SSL Virtual Functions assigned to VM Instance |
| OCT nsVmState | 1.3.6.1.4.1.5951.6.3.2.1.18 | OCTET STRING | read-only | State of Virtual Machine (Running | Halted) |
| I32 nsNumberOfCPU | 1.3.6.1.4.1.5951.6.3.2.1.19 | Integer32 | read-only | Number of CPU that is assigned to VM Instance |
| OCT nsVmMemoryTotal | 1.3.6.1.4.1.5951.6.3.2.1.21 | OCTET STRING | read-only | Total Memory of VM Instance in MB |
| OCT nsUptime | 1.3.6.1.4.1.5951.6.3.2.1.26 | OCTET STRING | read-only | Uptime of VM Instance |
| I32 nsNumberOfSSLCores | 1.3.6.1.4.1.5951.6.3.2.1.27 | Integer32 | read-only | Assign number of ssl virtual functions to VM Instance |
| OCT nsCpuCoreMgmt | 1.3.6.1.4.1.5951.6.3.2.1.28 | OCTET STRING | read-only | Management CPU cores assigned to VM Instance |
| OCT nsCpuCorePE | 1.3.6.1.4.1.5951.6.3.2.1.29 | OCTET STRING | read-only | Packet Engine cores assigned to VM Instance |
| OCT nsVmDescription | 1.3.6.1.4.1.5951.6.3.2.1.30 | OCTET STRING | read-only | Description |
| OCT nsThroughput | 1.3.6.1.4.1.5951.6.3.2.1.31 | OCTET STRING | read-only | Assign throughput in Mbps to VM Instance |
| I32 nsNumberOfCores | 1.3.6.1.4.1.5951.6.3.2.1.32 | Integer32 | read-only | Number of cores that are assigned to VM Instance |
| OCT nsNsCPUUsage | 1.3.6.1.4.1.5951.6.3.2.1.33 | OCTET STRING | read-only | CPU Usage (%) of NetScaler Instance |
| OCT nsNsMemoryUsage | 1.3.6.1.4.1.5951.6.3.2.1.35 | OCTET STRING | read-only | Memory Usage (%) |
| OCT nsNsTx | 1.3.6.1.4.1.5951.6.3.2.1.36 | OCTET STRING | read-only | Out Throughput of NetScaler Instance in Mbps |
| OCT nsNsRx | 1.3.6.1.4.1.5951.6.3.2.1.37 | OCTET STRING | read-only | In Throughput of NetScaler Instance in Mbps |
| OCT nsHttpReq | 1.3.6.1.4.1.5951.6.3.2.1.38 | OCTET STRING | read-only | HTTP Requests/second |
| OCT nsUpsince | 1.3.6.1.4.1.5951.6.3.2.1.39 | OCTET STRING | read-only | Upsince of NetScaler Instance |
| OCT nsLicense | 1.3.6.1.4.1.5951.6.3.2.1.40 | OCTET STRING | read-only | Feature License for NetScaler Instance, needs to be set while provisioning (standard, enterprise, platinum) |
| OCT nsHaMasterState | 1.3.6.1.4.1.5951.6.3.2.1.41 | OCTET STRING | read-only | Master State (Primary/Secondary) of NetScaler Instance |
| IPt nsHaIPAddressType | 1.3.6.1.4.1.5951.6.3.2.1.42 | InetAddressType | read-only | Type of nsHaIPAddress |
| IP nsHaIPAddress | 1.3.6.1.4.1.5951.6.3.2.1.43 | InetAddress | read-only | Peer IP Address of NetScaler Instance |
| OCT nsNodeState | 1.3.6.1.4.1.5951.6.3.2.1.44 | OCTET STRING | read-only | Node State of NetScaler Instance |
| OCT nsHaSync | 1.3.6.1.4.1.5951.6.3.2.1.45 | OCTET STRING | read-only | The state of synchronization of NetScaler Instance |
| OCT nsPps | 1.3.6.1.4.1.5951.6.3.2.1.46 | OCTET STRING | read-only | Assign packets per seconds to NetScaler Instance |
| I32 nsNumberOfSslCoresUp | 1.3.6.1.4.1.5951.6.3.2.1.47 | Integer32 | read-only | Number of SSL Cores Up |
| OCT nsIfOby1 | 1.3.6.1.4.1.5951.6.3.2.1.48 | OCTET STRING | read-only | Network 0/1 on VM Instance |
| OCT nsIf0by2 | 1.3.6.1.4.1.5951.6.3.2.1.49 | OCTET STRING | read-only | Network 0/2 on VM Instance |
| I32 nsNsVLANId | 1.3.6.1.4.1.5951.6.3.2.1.50 | Integer32 | read-only | VLAN Id |
| OCT nsNsVLANTagged | 1.3.6.1.4.1.5951.6.3.2.1.51 | OCTET STRING | read-only | NSVLAN Tagged |
| I32 nsVlanType | 1.3.6.1.4.1.5951.6.3.2.1.52 | Integer32 | read-only | VLAN Type, NS or L2 VLAN |
| cloudBridgeInstanceTable | 1.3.6.1.4.1.5951.6.3.3 | not-accessible | The SDX cloudBridgeInstancetable | |
| cloudBridgeInstanceEntry | 1.3.6.1.4.1.5951.6.3.3.1 | not-accessible | ... | |
| IPt cbIpAddressType | 1.3.6.1.4.1.5951.6.3.3.1.1 | InetAddressType | read-only | Type of cbIpAddress |
| IP cbIpAddress | 1.3.6.1.4.1.5951.6.3.3.1.2 | InetAddress | read-only | IP Address for this managed device |
| IPt cbHostIPAddressType | 1.3.6.1.4.1.5951.6.3.3.1.3 | InetAddressType | read-only | Type of cbHostIPAddress |
| IP cbHostIPAddress | 1.3.6.1.4.1.5951.6.3.3.1.4 | InetAddress | read-only | Host IPAddress where VM is provisioned |
| OCT cbProfileName | 1.3.6.1.4.1.5951.6.3.3.1.5 | OCTET STRING | read-only | Device Profile Name that is attached with this managed device |
| OCT cbName | 1.3.6.1.4.1.5951.6.3.3.1.6 | OCTET STRING | read-only | Name of managed device |
| IPt cbNetmaskType | 1.3.6.1.4.1.5951.6.3.3.1.7 | InetAddressType | read-only | Type of cbNetmask |
| IP cbNetmask | 1.3.6.1.4.1.5951.6.3.3.1.8 | InetAddress | read-only | Netmask of managed device |
| IPt cbGatewayType | 1.3.6.1.4.1.5951.6.3.3.1.9 | InetAddressType | read-only | Type of cbGateway |
| IP cbGateway | 1.3.6.1.4.1.5951.6.3.3.1.10 | InetAddress | read-only | Default Gateway of managed device |
| OCT cbHostname | 1.3.6.1.4.1.5951.6.3.3.1.11 | OCTET STRING | read-only | Assign hostname to managed device, if this is not provided, name will be set as host name |
| OCT cbDescription | 1.3.6.1.4.1.5951.6.3.3.1.12 | OCTET STRING | read-only | Description of managed device |
| OCT cbVersion | 1.3.6.1.4.1.5951.6.3.3.1.13 | OCTET STRING | read-only | Device Version |
| OCT cbInstanceState | 1.3.6.1.4.1.5951.6.3.3.1.14 | OCTET STRING | read-only | State of device, UP only if device accessible |
| OCT cbUuid | 1.3.6.1.4.1.5951.6.3.3.1.15 | OCTET STRING | read-only | UUID of VM Instance |
| OCT cbVirtualFunctions | 1.3.6.1.4.1.5951.6.3.3.1.16 | OCTET STRING | read-only | Virtual Functions assigned to VM Instance |
| OCT cbVmState | 1.3.6.1.4.1.5951.6.3.3.1.17 | OCTET STRING | read-only | State of Virtual Machine (Running | Halted) |
| I32 cbNumberOfCPU | 1.3.6.1.4.1.5951.6.3.3.1.18 | Integer32 | read-only | Number of CPU that is assigned to VM Instance |
| OCT cbVmCPUUsage | 1.3.6.1.4.1.5951.6.3.3.1.19 | OCTET STRING | read-only | CPU Usage (%) of VM Instance |
| OCT cbVmMemoryTotal | 1.3.6.1.4.1.5951.6.3.3.1.20 | OCTET STRING | read-only | Total Memory of VM Instance in MB |
| OCT cbVmMemoryFree | 1.3.6.1.4.1.5951.6.3.3.1.21 | OCTET STRING | read-only | Free Memory (MB) available in VM Instance |
| OCT cbVmMemoryUsage | 1.3.6.1.4.1.5951.6.3.3.1.22 | OCTET STRING | read-only | Memory Usage (%) of VM Instance |
| OCT cbUptime | 1.3.6.1.4.1.5951.6.3.3.1.25 | OCTET STRING | read-only | Uptime of VM Instance |
| OCT cbDiskAllocation | 1.3.6.1.4.1.5951.6.3.3.1.30 | OCTET STRING | read-only | Disk allocation for VM Instance |
| IPt cbAPAIPADDRESSType | 1.3.6.1.4.1.5951.6.3.3.1.47 | InetAddressType | read-only | Type of cbAPAIPADDRESS |
| IP cbAPAIPADDRESS | 1.3.6.1.4.1.5951.6.3.3.1.48 | InetAddress | read-only | aPA IP Address |
| IPt cbAPANetMaskType | 1.3.6.1.4.1.5951.6.3.3.1.49 | InetAddressType | read-only | Type of cbAPANetMask |
| IP cbAPANetMask | 1.3.6.1.4.1.5951.6.3.3.1.50 | InetAddress | read-only | aPA Netmask |
| IPt cbAPAGatewayType | 1.3.6.1.4.1.5951.6.3.3.1.51 | InetAddressType | read-only | Type of cbAPAGateway |
| IP cbAPAGateway | 1.3.6.1.4.1.5951.6.3.3.1.52 | InetAddress | read-only | aPA Gateway |
| IPt cbPluginIPADDRESSType | 1.3.6.1.4.1.5951.6.3.3.1.53 | InetAddressType | read-only | Type of cbPluginIPADDRESS |
| IP cbPluginIPADDRESS | 1.3.6.1.4.1.5951.6.3.3.1.54 | InetAddress | read-only | Plugin IP Address |
| IPt cbMgmtIPAddressType | 1.3.6.1.4.1.5951.6.3.3.1.57 | InetAddressType | read-only | Type of cbMgmtIPAddress |
| IP cbMgmtIPAddress | 1.3.6.1.4.1.5951.6.3.3.1.58 | InetAddress | read-only | Management IP Address for this CloudBridge |
| cloudBridgeAcceleratorTable | 1.3.6.1.4.1.5951.6.3.4 | not-accessible | The SDX cloudBridgeAcceleratortable | |
| cloudBridgeAcceleratorEntry | 1.3.6.1.4.1.5951.6.3.4.1 | not-accessible | ... | |
| IPt cbAcceleratorIpAddressType | 1.3.6.1.4.1.5951.6.3.4.1.1 | InetAddressType | read-only | Type of cbAcceleratorIpAddress |
| IP cbAcceleratorIpAddress | 1.3.6.1.4.1.5951.6.3.4.1.2 | InetAddress | read-only | IP Address for this managed device |
| IPt cbAcceleratorHostIPAddressType | 1.3.6.1.4.1.5951.6.3.4.1.3 | InetAddressType | read-only | Type of cbAcceleratorHostIPAddress |
| IP cbAcceleratorHostIPAddress | 1.3.6.1.4.1.5951.6.3.4.1.4 | InetAddress | read-only | Host IPAddress where VM is provisioned |
| OCT cbAcceleratorProfileName | 1.3.6.1.4.1.5951.6.3.4.1.5 | OCTET STRING | read-only | Device Profile Name that is attached with this managed device |
| OCT cbAcceleratorName | 1.3.6.1.4.1.5951.6.3.4.1.6 | OCTET STRING | read-only | Name of managed device |
| IPt cbAcceleratorNetmaskType | 1.3.6.1.4.1.5951.6.3.4.1.7 | InetAddressType | read-only | Type of cbAcceleratorNetmask |
| IP cbAcceleratorNetmask | 1.3.6.1.4.1.5951.6.3.4.1.8 | InetAddress | read-only | Netmask of managed device |
| IPt cbAcceleratorGatewayType | 1.3.6.1.4.1.5951.6.3.4.1.9 | InetAddressType | read-only | Type of cbAcceleratorGateway |
| IP cbAcceleratorGateway | 1.3.6.1.4.1.5951.6.3.4.1.10 | InetAddress | read-only | Default Gateway of managed device |
| OCT cbAcceleratorHostname | 1.3.6.1.4.1.5951.6.3.4.1.11 | OCTET STRING | read-only | Assign hostname to managed device, if this is not provided, name will be set as host name |
| OCT cbAcceleratorDescription | 1.3.6.1.4.1.5951.6.3.4.1.12 | OCTET STRING | read-only | Description of managed device |
| OCT cbAcceleratorVersion | 1.3.6.1.4.1.5951.6.3.4.1.13 | OCTET STRING | read-only | Device Version |
| OCT cbAcceleratorInstanceState | 1.3.6.1.4.1.5951.6.3.4.1.14 | OCTET STRING | read-only | State of device, UP only if device accessible |
| OCT cbAcceleratorUuid | 1.3.6.1.4.1.5951.6.3.4.1.15 | OCTET STRING | read-only | UUID of VM Instance |
| OCT cbAcceleratorVmState | 1.3.6.1.4.1.5951.6.3.4.1.16 | OCTET STRING | read-only | State of Virtual Machine (Running | Halted) |
| I32 cbAcceleratorNumberOfCPU | 1.3.6.1.4.1.5951.6.3.4.1.17 | Integer32 | read-only | Number of CPU that is assigned to VM Instance |
| OCT cbAcceleratorVmCPUUsage | 1.3.6.1.4.1.5951.6.3.4.1.18 | OCTET STRING | read-only | CPU Usage (%) of VM Instance |
| OCT cbAcceleratorVmMemoryTotal | 1.3.6.1.4.1.5951.6.3.4.1.19 | OCTET STRING | read-only | Total Memory of VM Instance in MB |
| OCT cbAcceleratorVmMemoryFree | 1.3.6.1.4.1.5951.6.3.4.1.20 | OCTET STRING | read-only | Free Memory (MB) available in VM Instance |
| OCT cbAcceleratorVmMemoryUsage | 1.3.6.1.4.1.5951.6.3.4.1.21 | OCTET STRING | read-only | Memory Usage (%) of VM Instance |
| OCT cbAcceleratorUptime | 1.3.6.1.4.1.5951.6.3.4.1.24 | OCTET STRING | read-only | Uptime of VM Instance |
| OCT cbAcceleratorIpList | 1.3.6.1.4.1.5951.6.3.4.1.31 | OCTET STRING | read-only | Specify the list of CloudBridge IPs for which this device will act as a CloudBridge Accelerator. |
| IPt cbAcceleratorMgmtIPAddressType | 1.3.6.1.4.1.5951.6.3.4.1.38 | InetAddressType | read-only | Type of cbAcceleratorMgmtIPAddress |
| IP cbAcceleratorMgmtIPAddress | 1.3.6.1.4.1.5951.6.3.4.1.39 | InetAddress | read-only | Management IP Address for this CloudBridge Accelerator Instance |
RFC description
Citrix Netscaler root MIB defining system, event groups, and platform information.
Start monitoring Citrix application delivery appliances with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.