All MIBs › SDX-ROOT-MIB
Organization: Citrix Systems, Inc.
Last Updated: 2013-12-05
Category: Citrix Application Delivery, Enterprise SMI and Registration
Description: Defines the Citrix SDX enterprise root OID tree hierarchy for appliance MIB registration.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is SDX-ROOT-MIB?
SDX-ROOT-MIB is the enterprise root MIB for Citrix's NetScaler SDX (Service Delivery appliance) platform, defining the top-level OID tree and core system identification objects for the SDX management hypervisor layer. It exposes platform and product identity (systemPlatform, systemProduct, systemBuildNumber) as well as networking configuration for the SDX management components, including the SVM (management service VM) and Xen hypervisor IP addressing, netmask, and gateway settings. Its monitoring value centers on software/platform status and management-plane connectivity: confirming the correct build/version is running and that the SVM and Xen management interfaces are correctly addressed and reachable, which is foundational before deeper per-instance NetScaler VPX monitoring can occur. It serves as the root registration point for other SDX-specific MIB branches (such as sdxEventGroup for event/notification data) and depends on the standard SNMPv2-SMI enterprises arc. It is deployed on Citrix (NetScaler) SDX multi-tenant application delivery appliances that host multiple NetScaler VPX instances, and administrators typically perform an SDX-ROOT-MIB download from Citrix to load the module into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in SDX-ROOT-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Citrix (NetScaler) SDX multi-tenant application delivery appliances
Monitoring Examples
An administrator would poll systemProduct and systemBuildNumber to confirm the SDX appliance's software version, then check systemSvmIPAddress and systemXenIPAddress against systemNetmask and systemGateway to verify the management plane's networking is correctly configured. A mismatch or unreachable systemSvmIPAddress would indicate the SDX management service VM has a networking problem, which would block visibility into the hosted NetScaler VPX instances.
What Can Be Monitored
- platform/product identity and build version
- SVM management IP configuration
- Xen hypervisor IP configuration
- netmask and gateway settings
- SDX event/notification registration
This MIB depends on
Related MIBs
Imported Objects
From INET-ADDRESS-MIB
| InetAddress | |
| InetAddressType |
From IPV6-TC
| Ipv6Address |
From SNMPv2-SMI
| Counter32 | |
| Gauge32 | |
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-IDENTITY | |
| OBJECT-TYPE | |
| TimeTicks | |
| enterprises |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF bmcFirmwareVersionError | 1.3.6.1.4.1.5951.6.1.2.15 | BMC firmware is missing or the version is not supported | ||
| NTF bmcFirmwareVersionNormal | 1.3.6.1.4.1.5951.6.1.2.16 | BMC firmware is detected or the version has returned to a supported version | ||
| OCT cbAcceleratorDescription | 1.3.6.1.4.1.5951.6.3.4.1.12 | OCTET STRING | read-only | Description of managed device |
| IP cbAcceleratorGateway | 1.3.6.1.4.1.5951.6.3.4.1.10 | InetAddress | read-only | Default Gateway of managed device |
| IPt cbAcceleratorGatewayType | 1.3.6.1.4.1.5951.6.3.4.1.9 | InetAddressType | read-only | Type of cbAcceleratorGateway |
| IP cbAcceleratorHostIPAddress | 1.3.6.1.4.1.5951.6.3.4.1.4 | InetAddress | read-only | Host IPAddress where VM is provisioned |
| IPt cbAcceleratorHostIPAddressType | 1.3.6.1.4.1.5951.6.3.4.1.3 | InetAddressType | read-only | Type of cbAcceleratorHostIPAddress |
| OCT cbAcceleratorHostname | 1.3.6.1.4.1.5951.6.3.4.1.11 | OCTET STRING | read-only | Assign hostname to managed device, if this is not provided, name will be set as host name |
| OCT cbAcceleratorInstanceState | 1.3.6.1.4.1.5951.6.3.4.1.14 | OCTET STRING | read-only | State of device, UP only if device accessible |
| IP cbAcceleratorIpAddress | 1.3.6.1.4.1.5951.6.3.4.1.2 | InetAddress | read-only | IP Address for this managed device |
| IPt cbAcceleratorIpAddressType | 1.3.6.1.4.1.5951.6.3.4.1.1 | InetAddressType | read-only | Type of cbAcceleratorIpAddress |
| OCT cbAcceleratorIpList | 1.3.6.1.4.1.5951.6.3.4.1.31 | OCTET STRING | read-only | Specify the list of CloudBridge IPs for which this device will act as a CloudBridge Accelerator. |
| IP cbAcceleratorMgmtIPAddress | 1.3.6.1.4.1.5951.6.3.4.1.39 | InetAddress | read-only | Management IP Address for this CloudBridge Accelerator Instance |
| IPt cbAcceleratorMgmtIPAddressType | 1.3.6.1.4.1.5951.6.3.4.1.38 | InetAddressType | read-only | Type of cbAcceleratorMgmtIPAddress |
| OCT cbAcceleratorName | 1.3.6.1.4.1.5951.6.3.4.1.6 | OCTET STRING | read-only | Name of managed device |
| IP cbAcceleratorNetmask | 1.3.6.1.4.1.5951.6.3.4.1.8 | InetAddress | read-only | Netmask of managed device |
| IPt cbAcceleratorNetmaskType | 1.3.6.1.4.1.5951.6.3.4.1.7 | InetAddressType | read-only | Type of cbAcceleratorNetmask |
| I32 cbAcceleratorNumberOfCPU | 1.3.6.1.4.1.5951.6.3.4.1.17 | Integer32 | read-only | Number of CPU that is assigned to VM Instance |
| OCT cbAcceleratorProfileName | 1.3.6.1.4.1.5951.6.3.4.1.5 | OCTET STRING | read-only | Device Profile Name that is attached with this managed device |
| OCT cbAcceleratorUptime | 1.3.6.1.4.1.5951.6.3.4.1.24 | OCTET STRING | read-only | Uptime of VM Instance |
| OCT cbAcceleratorUuid | 1.3.6.1.4.1.5951.6.3.4.1.15 | OCTET STRING | read-only | UUID of VM Instance |
| OCT cbAcceleratorVersion | 1.3.6.1.4.1.5951.6.3.4.1.13 | OCTET STRING | read-only | Device Version |
| OCT cbAcceleratorVmCPUUsage | 1.3.6.1.4.1.5951.6.3.4.1.18 | OCTET STRING | read-only | CPU Usage (%) of VM Instance |
| OCT cbAcceleratorVmMemoryFree | 1.3.6.1.4.1.5951.6.3.4.1.20 | OCTET STRING | read-only | Free Memory (MB) available in VM Instance |
| OCT cbAcceleratorVmMemoryTotal | 1.3.6.1.4.1.5951.6.3.4.1.19 | OCTET STRING | read-only | Total Memory of VM Instance in MB |
| OCT cbAcceleratorVmMemoryUsage | 1.3.6.1.4.1.5951.6.3.4.1.21 | OCTET STRING | read-only | Memory Usage (%) of VM Instance |
| OCT cbAcceleratorVmState | 1.3.6.1.4.1.5951.6.3.4.1.16 | OCTET STRING | read-only | State of Virtual Machine (Running | Halted) |
| IP cbAPAGateway | 1.3.6.1.4.1.5951.6.3.3.1.52 | InetAddress | read-only | aPA Gateway |
| IPt cbAPAGatewayType | 1.3.6.1.4.1.5951.6.3.3.1.51 | InetAddressType | read-only | Type of cbAPAGateway |
| IP cbAPAIPADDRESS | 1.3.6.1.4.1.5951.6.3.3.1.48 | InetAddress | read-only | aPA IP Address |
| IPt cbAPAIPADDRESSType | 1.3.6.1.4.1.5951.6.3.3.1.47 | InetAddressType | read-only | Type of cbAPAIPADDRESS |
| IP cbAPANetMask | 1.3.6.1.4.1.5951.6.3.3.1.50 | InetAddress | read-only | aPA Netmask |
| IPt cbAPANetMaskType | 1.3.6.1.4.1.5951.6.3.3.1.49 | InetAddressType | read-only | Type of cbAPANetMask |
| OCT cbDescription | 1.3.6.1.4.1.5951.6.3.3.1.12 | OCTET STRING | read-only | Description of managed device |
| OCT cbDiskAllocation | 1.3.6.1.4.1.5951.6.3.3.1.30 | OCTET STRING | read-only | Disk allocation for VM Instance |
| IP cbGateway | 1.3.6.1.4.1.5951.6.3.3.1.10 | InetAddress | read-only | Default Gateway of managed device |
| IPt cbGatewayType | 1.3.6.1.4.1.5951.6.3.3.1.9 | InetAddressType | read-only | Type of cbGateway |
| IP cbHostIPAddress | 1.3.6.1.4.1.5951.6.3.3.1.4 | InetAddress | read-only | Host IPAddress where VM is provisioned |
| IPt cbHostIPAddressType | 1.3.6.1.4.1.5951.6.3.3.1.3 | InetAddressType | read-only | Type of cbHostIPAddress |
| OCT cbHostname | 1.3.6.1.4.1.5951.6.3.3.1.11 | OCTET STRING | read-only | Assign hostname to managed device, if this is not provided, name will be set as host name |
| OCT cbInstanceState | 1.3.6.1.4.1.5951.6.3.3.1.14 | OCTET STRING | read-only | State of device, UP only if device accessible |
| IP cbIpAddress | 1.3.6.1.4.1.5951.6.3.3.1.2 | InetAddress | read-only | IP Address for this managed device |
| IPt cbIpAddressType | 1.3.6.1.4.1.5951.6.3.3.1.1 | InetAddressType | read-only | Type of cbIpAddress |
| IP cbMgmtIPAddress | 1.3.6.1.4.1.5951.6.3.3.1.58 | InetAddress | read-only | Management IP Address for this CloudBridge |
| IPt cbMgmtIPAddressType | 1.3.6.1.4.1.5951.6.3.3.1.57 | InetAddressType | read-only | Type of cbMgmtIPAddress |
| OCT cbName | 1.3.6.1.4.1.5951.6.3.3.1.6 | OCTET STRING | read-only | Name of managed device |
| IP cbNetmask | 1.3.6.1.4.1.5951.6.3.3.1.8 | InetAddress | read-only | Netmask of managed device |
| IPt cbNetmaskType | 1.3.6.1.4.1.5951.6.3.3.1.7 | InetAddressType | read-only | Type of cbNetmask |
| I32 cbNumberOfCPU | 1.3.6.1.4.1.5951.6.3.3.1.18 | Integer32 | read-only | Number of CPU that is assigned to VM Instance |
| IP cbPluginIPADDRESS | 1.3.6.1.4.1.5951.6.3.3.1.54 | InetAddress | read-only | Plugin IP Address |
| IPt cbPluginIPADDRESSType | 1.3.6.1.4.1.5951.6.3.3.1.53 | InetAddressType | read-only | Type of cbPluginIPADDRESS |
| OCT cbProfileName | 1.3.6.1.4.1.5951.6.3.3.1.5 | OCTET STRING | read-only | Device Profile Name that is attached with this managed device |
| OCT cbUptime | 1.3.6.1.4.1.5951.6.3.3.1.25 | OCTET STRING | read-only | Uptime of VM Instance |
| OCT cbUuid | 1.3.6.1.4.1.5951.6.3.3.1.15 | OCTET STRING | read-only | UUID of VM Instance |
| OCT cbVersion | 1.3.6.1.4.1.5951.6.3.3.1.13 | OCTET STRING | read-only | Device Version |
| OCT cbVirtualFunctions | 1.3.6.1.4.1.5951.6.3.3.1.16 | OCTET STRING | read-only | Virtual Functions assigned to VM Instance |
| OCT cbVmCPUUsage | 1.3.6.1.4.1.5951.6.3.3.1.19 | OCTET STRING | read-only | CPU Usage (%) of VM Instance |
| OCT cbVmMemoryFree | 1.3.6.1.4.1.5951.6.3.3.1.21 | OCTET STRING | read-only | Free Memory (MB) available in VM Instance |
| OCT cbVmMemoryTotal | 1.3.6.1.4.1.5951.6.3.3.1.20 | OCTET STRING | read-only | Total Memory of VM Instance in MB |
| OCT cbVmMemoryUsage | 1.3.6.1.4.1.5951.6.3.3.1.22 | OCTET STRING | read-only | Memory Usage (%) of VM Instance |
| OCT cbVmState | 1.3.6.1.4.1.5951.6.3.3.1.17 | OCTET STRING | read-only | State of Virtual Machine (Running | Halted) |
| cloudBridgeAcceleratorEntry | 1.3.6.1.4.1.5951.6.3.4.1 | not-accessible | ... | |
| cloudBridgeAcceleratorTable | 1.3.6.1.4.1.5951.6.3.4 | not-accessible | The SDX cloudBridgeAcceleratortable | |
| cloudBridgeInstanceEntry | 1.3.6.1.4.1.5951.6.3.3.1 | not-accessible | ... | |
| cloudBridgeInstanceTable | 1.3.6.1.4.1.5951.6.3.3 | not-accessible | The SDX cloudBridgeInstancetable | |
| NTF cpuAffinityRecoveryFailed | 1.3.6.1.4.1.5951.6.1.2.41 | CPU affinity recovery has failed | ||
| NTF cpuAffinityRecoverySuccess | 1.3.6.1.4.1.5951.6.1.2.42 | CPU affinity recovery is successful | ||
| NTF cpuTempError | 1.3.6.1.4.1.5951.6.1.2.21 | CPU temperature error; entityName and eventMessage show specific failure information | ||
| NTF cpuTempNormal | 1.3.6.1.4.1.5951.6.1.2.22 | CPU temperature has returned to normal | ||
| NTF cpuUsageHigh | 1.3.6.1.4.1.5951.6.1.2.1 | CPU utilization has exceeded the high threshold value | ||
| NTF cpuUsageNormal | 1.3.6.1.4.1.5951.6.1.2.2 | CPU utilization has returned to normal | ||
| OCT currentValue | 1.3.6.1.4.1.5951.6.1.1.6 | OCTET STRING | accessible-for-notify | Current value of the entity when high or normal threshold trap is sent |
| NTF deviceAdded | 1.3.6.1.4.1.5951.6.1.2.50 | A managed device has been added | ||
| NTF deviceBootFailed | 1.3.6.1.4.1.5951.6.1.2.55 | A managed device has failed to start | ||
| deviceGroup | 1.3.6.1.4.1.5951.6.3 | |||
| NTF deviceModified | 1.3.6.1.4.1.5951.6.1.2.52 | An attribute of a managed device has been changed | ||
| NTF devicePowerStateChanged | 1.3.6.1.4.1.5951.6.1.2.53 | Power state of a managed device has changed | ||
| NTF deviceRebootFailed | 1.3.6.1.4.1.5951.6.1.2.56 | A managed device has failed to restart | ||
| NTF deviceRemoved | 1.3.6.1.4.1.5951.6.1.2.51 | A managed device has been removed | ||
| NTF deviceStateChanged | 1.3.6.1.4.1.5951.6.1.2.54 | Instance state of a managed device has changed | ||
| I32 diskBayNumber | 1.3.6.1.4.1.5951.6.2.1000.3.1.11 | Integer32 | read-only | Bay number |
| OCT diskBlockReadRate | 1.3.6.1.4.1.5951.6.2.1000.3.1.5 | OCTET STRING | read-only | Blocks read per second |
| OCT diskBlockWriteRate | 1.3.6.1.4.1.5951.6.2.1000.3.1.6 | OCTET STRING | read-only | Blocks written per second |
| diskEntry | 1.3.6.1.4.1.5951.6.2.1000.3.1 | not-accessible | ... | |
| IP diskHostIPAddress | 1.3.6.1.4.1.5951.6.2.1000.3.1.3 | InetAddress | read-only | Host IP Address |
| IPt diskHostIPAddressType | 1.3.6.1.4.1.5951.6.2.1000.3.1.2 | InetAddressType | read-only | Type of diskHostIPAddress |
| OCT diskName | 1.3.6.1.4.1.5951.6.2.1000.3.1.1 | OCTET STRING | read-only | Name of the Disk |
| OCT diskSize | 1.3.6.1.4.1.5951.6.2.1000.3.1.10 | OCTET STRING | read-only | Size of the disk (bytes) |
| diskTable | 1.3.6.1.4.1.5951.6.2.1000.3 | not-accessible | The SDX disktable | |
| OCT diskTotalBlocksRead | 1.3.6.1.4.1.5951.6.2.1000.3.1.7 | OCTET STRING | read-only | Total blocks read |
| OCT diskTotalBlocksWritten | 1.3.6.1.4.1.5951.6.2.1000.3.1.8 | OCTET STRING | read-only | Total blocks written |
| OCT diskTransactionRate | 1.3.6.1.4.1.5951.6.2.1000.3.1.4 | OCTET STRING | read-only | Transactions per second |
| OCT diskUtilized | 1.3.6.1.4.1.5951.6.2.1000.3.1.9 | OCTET STRING | read-only | Utilization of the disk (bytes) |
| OCT entityName | 1.3.6.1.4.1.5951.6.1.1.2 | OCTET STRING | accessible-for-notify | Name of the entity associated with this alarm |
| OCT entityType | 1.3.6.1.4.1.5951.6.1.1.3 | OCTET STRING | accessible-for-notify | Type of entity associated with this alarm |
| OCT eventMessage | 1.3.6.1.4.1.5951.6.1.1.4 | OCTET STRING | accessible-for-notify | Message associated with this alarm |
| eventVarBindOids | 1.3.6.1.4.1.5951.6.1.1 | |||
| NTF fanSpeedError | 1.3.6.1.4.1.5951.6.1.2.19 | Fan speed is either high or low | ||
| NTF fanSpeedNormal | 1.3.6.1.4.1.5951.6.1.2.20 | Fan speed has returned to normal | ||
| OCT hardwareResourceCurrentValue | 1.3.6.1.4.1.5951.6.2.1000.1.1.4 | OCTET STRING | read-only | Current value of the resource |
| hardwareResourceEntry | 1.3.6.1.4.1.5951.6.2.1000.1.1 | not-accessible | ... | |
| OCT hardwareResourceExpectedValue | 1.3.6.1.4.1.5951.6.2.1000.1.1.5 | OCTET STRING | read-only | Expected value of the resource |
| IP hardwareResourceHostIPAddress | 1.3.6.1.4.1.5951.6.2.1000.1.1.3 | InetAddress | read-only | Host IP Address |
| IPt hardwareResourceHostIPAddressType | 1.3.6.1.4.1.5951.6.2.1000.1.1.2 | InetAddressType | read-only | Type of hardwareResourceHostIPAddress |
| OCT hardwareResourceName | 1.3.6.1.4.1.5951.6.2.1000.1.1.1 | OCTET STRING | read-only | Resource name |
| OCT hardwareResourceStatus | 1.3.6.1.4.1.5951.6.2.1000.1.1.7 | OCTET STRING | read-only | Health status of the resource - OK/ERROR |
| hardwareResourceTable | 1.3.6.1.4.1.5951.6.2.1000.1 | not-accessible | The SDX hardwareResourcetable | |
| OCT hardwareResourceUnit | 1.3.6.1.4.1.5951.6.2.1000.1.1.6 | OCTET STRING | read-only | Measurement unit for the resource |
| NTF healthCounterError | 1.3.6.1.4.1.5951.6.1.2.31 | Health Counter Error; entityName and eventMessage show specific failure information | ||
| NTF healthCounterNormal | 1.3.6.1.4.1.5951.6.1.2.32 | Health Counter Error condition has returned to normal; entityName and eventMessage show details | ||
| NTF healthMonitorPluginError | 1.3.6.1.4.1.5951.6.1.2.73 | This trap is sent when health monitor plugin (xsnsmonitor) is not installed on XenServer | ||
| NTF healthMonitorPluginNormal | 1.3.6.1.4.1.5951.6.1.2.74 | This trap is sent when health monitor plugin (xsnsmonitor) is back to installed state on XenServer | ||
| NTF interfaceDown | 1.3.6.1.4.1.5951.6.1.2.33 | A network interface has gone down; entityName and eventMessage show details | ||
| interfaceEntry | 1.3.6.1.4.1.5951.6.2.1000.5.1 | not-accessible | ... | |
| IP interfaceHostIPAddress | 1.3.6.1.4.1.5951.6.2.1000.5.1.3 | InetAddress | read-only | Host IP Address |
| IPt interfaceHostIPAddressType | 1.3.6.1.4.1.5951.6.2.1000.5.1.2 | InetAddressType | read-only | Type of interfaceHostIPAddress |
| OCT interfaceMappedPort | 1.3.6.1.4.1.5951.6.2.1000.5.1.13 | OCTET STRING | read-only | Mapped Port Name Ex: eth0 |
| OCT interfacePort | 1.3.6.1.4.1.5951.6.2.1000.5.1.1 | OCTET STRING | read-only | Port Name Ex: 10/1 |
| OCT interfaceRxBytes | 1.3.6.1.4.1.5951.6.2.1000.5.1.7 | OCTET STRING | read-only | Received bytes |
| OCT interfaceRxErrors | 1.3.6.1.4.1.5951.6.2.1000.5.1.9 | OCTET STRING | read-only | Receiving errors |
| OCT interfaceRxPackets | 1.3.6.1.4.1.5951.6.2.1000.5.1.5 | OCTET STRING | read-only | Received packets |
| OCT interfaceState | 1.3.6.1.4.1.5951.6.2.1000.5.1.4 | OCTET STRING | read-only | State of the Interface - UP/DOWN |
| interfaceTable | 1.3.6.1.4.1.5951.6.2.1000.5 | not-accessible | The SDX interfacetable | |
| OCT interfaceTxBytes | 1.3.6.1.4.1.5951.6.2.1000.5.1.8 | OCTET STRING | read-only | Transmitted bytes |
| OCT interfaceTxErrors | 1.3.6.1.4.1.5951.6.2.1000.5.1.10 | OCTET STRING | read-only | Transmission errors |
| OCT interfaceTxPackets | 1.3.6.1.4.1.5951.6.2.1000.5.1.6 | OCTET STRING | read-only | Transmitted packets |
| NTF interfaceUp | 1.3.6.1.4.1.5951.6.1.2.34 | The network interface has returned to UP state; entityName and eventMessage show details | ||
| I32 interfaceVfAssigned | 1.3.6.1.4.1.5951.6.2.1000.5.1.12 | Integer32 | read-only | Assigned Virtual Functions |
| I32 interfaceVfTotal | 1.3.6.1.4.1.5951.6.2.1000.5.1.11 | Integer32 | read-only | Total Virtual Functions |
| NTF inventoryFailed | 1.3.6.1.4.1.5951.6.1.2.72 | XenServer inventory collection has failed | ||
| NTF ipmiStateError | 1.3.6.1.4.1.5951.6.1.2.13 | Intelligent Platform Management Interface (IPMI) utility is missing | ||
| NTF ipmiStateNormal | 1.3.6.1.4.1.5951.6.1.2.14 | Intelligent Platform Management Interface (IPMI) utility is detected | ||
| NTF logicalDriveFailed | 1.3.6.1.4.1.5951.6.1.2.76 | Logical Drive Failed | ||
| NTF loginFailure | 1.3.6.1.4.1.5951.6.1.2.71 | This trap is sent when User Authentication fails. 'entityName' and 'eventMessage' will show specific failure information | ||
| NTF memoryUsageHigh | 1.3.6.1.4.1.5951.6.1.2.3 | Memory utilization has exceeded the high threshold value. On SDX platform since memory for an instance is decided by the administrator, this trap is not raised | ||
| NTF memoryUsageNormal | 1.3.6.1.4.1.5951.6.1.2.4 | Memory utilization has returned to normal | ||
| NTF mpsDown | 1.3.6.1.4.1.5951.6.1.2.46 | All subsystems are DOWN | ||
| NTF mpsUp | 1.3.6.1.4.1.5951.6.1.2.47 | All subsystems are UP | ||
| netScaler | 1.3.6.1.4.1.5951 | The enterprise specific MIB for Netscaler NS10.0. | ||
| netscalerEntry | 1.3.6.1.4.1.5951.6.3.2.1 | not-accessible | ... | |
| netscalerTable | 1.3.6.1.4.1.5951.6.3.2 | not-accessible | The SDX netscalertable | |
| OCT nsCpuCoreMgmt | 1.3.6.1.4.1.5951.6.3.2.1.28 | OCTET STRING | read-only | Management CPU cores assigned to VM Instance |
| OCT nsCpuCorePE | 1.3.6.1.4.1.5951.6.3.2.1.29 | OCTET STRING | read-only | Packet Engine cores assigned to VM Instance |
| OCT nsDescription | 1.3.6.1.4.1.5951.6.3.2.1.12 | OCTET STRING | read-only | Description of managed device |
| IP nsGateway | 1.3.6.1.4.1.5951.6.3.2.1.10 | InetAddress | read-only | Default Gateway of managed device |
| IPt nsGatewayType | 1.3.6.1.4.1.5951.6.3.2.1.9 | InetAddressType | read-only | Type of nsGateway |
| IP nsHaIPAddress | 1.3.6.1.4.1.5951.6.3.2.1.43 | InetAddress | read-only | Peer IP Address of NetScaler Instance |
| IPt nsHaIPAddressType | 1.3.6.1.4.1.5951.6.3.2.1.42 | InetAddressType | read-only | Type of nsHaIPAddress |
| OCT nsHaMasterState | 1.3.6.1.4.1.5951.6.3.2.1.41 | OCTET STRING | read-only | Master State (Primary/Secondary) of NetScaler Instance |
| OCT nsHaSync | 1.3.6.1.4.1.5951.6.3.2.1.45 | OCTET STRING | read-only | The state of synchronization of NetScaler Instance |
| IP nsHostIPAddress | 1.3.6.1.4.1.5951.6.3.2.1.4 | InetAddress | read-only | Host IPAddress where VM is provisioned |
| IPt nsHostIPAddressType | 1.3.6.1.4.1.5951.6.3.2.1.3 | InetAddressType | read-only | Type of nsHostIPAddress |
| OCT nsHostname | 1.3.6.1.4.1.5951.6.3.2.1.11 | OCTET STRING | read-only | Assign hostname to managed device, if this is not provided, name will be set as host name |
| OCT nsHttpReq | 1.3.6.1.4.1.5951.6.3.2.1.38 | OCTET STRING | read-only | HTTP Requests/second |
| OCT nsIf0by2 | 1.3.6.1.4.1.5951.6.3.2.1.49 | OCTET STRING | read-only | Network 0/2 on VM Instance |
| OCT nsIfOby1 | 1.3.6.1.4.1.5951.6.3.2.1.48 | OCTET STRING | read-only | Network 0/1 on VM Instance |
| OCT nsInstanceState | 1.3.6.1.4.1.5951.6.3.2.1.15 | OCTET STRING | read-only | State of device, UP only if device accessible |
| IP nsIpAddress | 1.3.6.1.4.1.5951.6.3.2.1.2 | InetAddress | read-only | IP Address for this managed device |
| IPt nsIpAddressType | 1.3.6.1.4.1.5951.6.3.2.1.1 | InetAddressType | read-only | Type of nsIpAddress |
| OCT nsLicense | 1.3.6.1.4.1.5951.6.3.2.1.40 | OCTET STRING | read-only | Feature License for NetScaler Instance, needs to be set while provisioning (standard, enterprise, platinum) |
| OCT nsName | 1.3.6.1.4.1.5951.6.3.2.1.6 | OCTET STRING | read-only | Name of managed device |
| IP nsNetmask | 1.3.6.1.4.1.5951.6.3.2.1.8 | InetAddress | read-only | Netmask of managed device |
| IPt nsNetmaskType | 1.3.6.1.4.1.5951.6.3.2.1.7 | InetAddressType | read-only | Type of nsNetmask |
| OCT nsNodeState | 1.3.6.1.4.1.5951.6.3.2.1.44 | OCTET STRING | read-only | Node State of NetScaler Instance |
| OCT nsNsCPUUsage | 1.3.6.1.4.1.5951.6.3.2.1.33 | OCTET STRING | read-only | CPU Usage (%) of NetScaler Instance |
| OCT nsNsMemoryUsage | 1.3.6.1.4.1.5951.6.3.2.1.35 | OCTET STRING | read-only | Memory Usage (%) |
| OCT nsNsRx | 1.3.6.1.4.1.5951.6.3.2.1.37 | OCTET STRING | read-only | In Throughput of NetScaler Instance in Mbps |
| OCT nsNsTx | 1.3.6.1.4.1.5951.6.3.2.1.36 | OCTET STRING | read-only | Out Throughput of NetScaler Instance in Mbps |
| I32 nsNsVLANId | 1.3.6.1.4.1.5951.6.3.2.1.50 | Integer32 | read-only | VLAN Id |
| OCT nsNsVLANTagged | 1.3.6.1.4.1.5951.6.3.2.1.51 | OCTET STRING | read-only | NSVLAN Tagged |
| I32 nsNumberOfCores | 1.3.6.1.4.1.5951.6.3.2.1.32 | Integer32 | read-only | Number of cores that are assigned to VM Instance |
| I32 nsNumberOfCPU | 1.3.6.1.4.1.5951.6.3.2.1.19 | Integer32 | read-only | Number of CPU that is assigned to VM Instance |
| I32 nsNumberOfSSLCores | 1.3.6.1.4.1.5951.6.3.2.1.27 | Integer32 | read-only | Assign number of ssl virtual functions to VM Instance |
| I32 nsNumberOfSslCoresUp | 1.3.6.1.4.1.5951.6.3.2.1.47 | Integer32 | read-only | Number of SSL Cores Up |
| OCT nsPps | 1.3.6.1.4.1.5951.6.3.2.1.46 | OCTET STRING | read-only | Assign packets per seconds to NetScaler Instance |
| OCT nsProfileName | 1.3.6.1.4.1.5951.6.3.2.1.5 | OCTET STRING | read-only | Device Profile Name that is attached with this managed device |
| OCT nsSslVirtualFunctions | 1.3.6.1.4.1.5951.6.3.2.1.17 | OCTET STRING | read-only | SSL Virtual Functions assigned to VM Instance |
| OCT nsThroughput | 1.3.6.1.4.1.5951.6.3.2.1.31 | OCTET STRING | read-only | Assign throughput in Mbps to VM Instance |
| OCT nsUpsince | 1.3.6.1.4.1.5951.6.3.2.1.39 | OCTET STRING | read-only | Upsince of NetScaler Instance |
| OCT nsUptime | 1.3.6.1.4.1.5951.6.3.2.1.26 | OCTET STRING | read-only | Uptime of VM Instance |
| OCT nsUuid | 1.3.6.1.4.1.5951.6.3.2.1.14 | OCTET STRING | read-only | UUID of VM Instance |
| OCT nsVersion | 1.3.6.1.4.1.5951.6.3.2.1.13 | OCTET STRING | read-only | Device Version |
| OCT nsVirtualFunctions | 1.3.6.1.4.1.5951.6.3.2.1.16 | OCTET STRING | read-only | Virtual Functions assigned to VM Instance |
| I32 nsVlanType | 1.3.6.1.4.1.5951.6.3.2.1.52 | Integer32 | read-only | VLAN Type, NS or L2 VLAN |
| OCT nsVmDescription | 1.3.6.1.4.1.5951.6.3.2.1.30 | OCTET STRING | read-only | Description |
| OCT nsVmMemoryTotal | 1.3.6.1.4.1.5951.6.3.2.1.21 | OCTET STRING | read-only | Total Memory of VM Instance in MB |
| OCT nsVmState | 1.3.6.1.4.1.5951.6.3.2.1.18 | OCTET STRING | read-only | State of Virtual Machine (Running | Halted) |
| NTF passwordRecoveryFailed | 1.3.6.1.4.1.5951.6.1.2.48 | Password recovery has failed | ||
| NTF passwordRecoverySuccess | 1.3.6.1.4.1.5951.6.1.2.49 | Password has been recovered successfully | ||
| NTF physicalDriveFailed | 1.3.6.1.4.1.5951.6.1.2.77 | Physical Drive Failed | ||
| NTF powerSupplyFailed | 1.3.6.1.4.1.5951.6.1.2.27 | Power Supply error; entityName and eventMessage show specific failure information information | ||
| NTF powerSupplyNormal | 1.3.6.1.4.1.5951.6.1.2.28 | Power Supply has returned to normal condition | ||
| NTF resourceStateError | 1.3.6.1.4.1.5951.6.1.2.17 | A hardware or software resource error has occurred; entityName and eventMessage show specific failure information | ||
| NTF resourceStateNormal | 1.3.6.1.4.1.5951.6.1.2.18 | The hardware or software resource error has been fixed and normal state has been restored; entityName and eventMessage show details | ||
| sdxEventGroup | 1.3.6.1.4.1.5951.6.1 | |||
| sdxEvents | 1.3.6.1.4.1.5951.6.1.2 | |||
| sdxRoot | 1.3.6.1.4.1.5951.6 | |||
| OCT severity | 1.3.6.1.4.1.5951.6.1.1.7 | OCTET STRING | accessible-for-notify | Severity associated with this alarm |
| OCT softwareResourceCurrentValue | 1.3.6.1.4.1.5951.6.2.1000.2.1.4 | OCTET STRING | read-only | Current value of the resource |
| softwareResourceEntry | 1.3.6.1.4.1.5951.6.2.1000.2.1 | not-accessible | ... | |
| OCT softwareResourceExpectedValue | 1.3.6.1.4.1.5951.6.2.1000.2.1.5 | OCTET STRING | read-only | Expected value of the resource |
| IP softwareResourceHostIPAddress | 1.3.6.1.4.1.5951.6.2.1000.2.1.3 | InetAddress | read-only | Host IP Address |
| IPt softwareResourceHostIPAddressType | 1.3.6.1.4.1.5951.6.2.1000.2.1.2 | InetAddressType | read-only | Type of softwareResourceHostIPAddress |
| OCT softwareResourceName | 1.3.6.1.4.1.5951.6.2.1000.2.1.1 | OCTET STRING | read-only | Resource name |
| OCT softwareResourceStatus | 1.3.6.1.4.1.5951.6.2.1000.2.1.7 | OCTET STRING | read-only | Health status of the resource - OK/ERROR |
| softwareResourceTable | 1.3.6.1.4.1.5951.6.2.1000.2 | not-accessible | The SDX softwareResourcetable | |
| OCT softwareResourceUnit | 1.3.6.1.4.1.5951.6.2.1000.2.1.6 | OCTET STRING | read-only | Measurement unit for the resource |
| OCT source | 1.3.6.1.4.1.5951.6.1.1.1 | OCTET STRING | accessible-for-notify | IP address of the device generating the event |
| OCT srBayNumber | 1.3.6.1.4.1.5951.6.2.1000.4.1.2 | OCTET STRING | read-only | Bay number |
| srEntry | 1.3.6.1.4.1.5951.6.2.1000.4.1 | not-accessible | ... | |
| IP srHostIPAddress | 1.3.6.1.4.1.5951.6.2.1000.4.1.4 | InetAddress | read-only | Host IP Address |
| IPt srHostIPAddressType | 1.3.6.1.4.1.5951.6.2.1000.4.1.3 | InetAddressType | read-only | Type of srHostIPAddress |
| OCT srName | 1.3.6.1.4.1.5951.6.2.1000.4.1.1 | OCTET STRING | read-only | Name of the storage repository |
| OCT srSize | 1.3.6.1.4.1.5951.6.2.1000.4.1.6 | OCTET STRING | read-only | Physical size of the storage repository |
| OCT srStatus | 1.3.6.1.4.1.5951.6.2.1000.4.1.7 | OCTET STRING | read-only | Status of the storage repository - OK/ERROR |
| srTable | 1.3.6.1.4.1.5951.6.2.1000.4 | not-accessible | The SDX srtable | |
| OCT srUtilized | 1.3.6.1.4.1.5951.6.2.1000.4.1.5 | OCTET STRING | read-only | Physical utilization of the storage repository |
| NTF subSystemDown | 1.3.6.1.4.1.5951.6.1.2.43 | A subsystem has gone DOWN; entityName shows details | ||
| NTF subSystemFailed | 1.3.6.1.4.1.5951.6.1.2.45 | A subsystem has failed; entityName shows details | ||
| NTF subSystemUp | 1.3.6.1.4.1.5951.6.1.2.44 | A subsystem has returned to the UP state; entityName shows details | ||
| sysHealthGroup | 1.3.6.1.4.1.5951.6.2.1000 | |||
| OCT systemAvailableThroughput | 1.3.6.1.4.1.5951.6.2.21 | OCTET STRING | read-only | Available Throughput in Mbps |
| OCT systemBiosVersion | 1.3.6.1.4.1.5951.6.2.19 | OCTET STRING | read-only | BIOS Version |
| OCT systemBuildNumber | 1.3.6.1.4.1.5951.6.2.3 | OCTET STRING | read-only | Build Number |
| I32 systemCurrentTime | 1.3.6.1.4.1.5951.6.2.17 | Integer32 | read-only | Current Time |
| IP systemDns | 1.3.6.1.4.1.5951.6.2.14 | InetAddress | read-only | DNS Server |
| IPt systemDnsType | 1.3.6.1.4.1.5951.6.2.13 | InetAddressType | read-only | Type of systemDns |
| IP systemGateway | 1.3.6.1.4.1.5951.6.2.11 | InetAddress | read-only | Gateway |
| IPt systemGatewayType | 1.3.6.1.4.1.5951.6.2.10 | InetAddressType | read-only | Type of systemGateway |
| systemGroup | 1.3.6.1.4.1.5951.6.2 | |||
| OCT systemHostId | 1.3.6.1.4.1.5951.6.2.22 | OCTET STRING | read-only | Host Id |
| OCT systemMaxThroughput | 1.3.6.1.4.1.5951.6.2.20 | OCTET STRING | read-only | Maximum Throughput in Mbps |
| IP systemNetmask | 1.3.6.1.4.1.5951.6.2.9 | InetAddress | read-only | Netmask |
| IPt systemNetmaskType | 1.3.6.1.4.1.5951.6.2.8 | InetAddressType | read-only | Type of systemNetmask |
| OCT systemNetworkInterface | 1.3.6.1.4.1.5951.6.2.12 | OCTET STRING | read-only | Interface on which management needs to be enabled |
| OCT systemPlatform | 1.3.6.1.4.1.5951.6.2.1 | OCTET STRING | read-only | Platform |
| OCT systemProduct | 1.3.6.1.4.1.5951.6.2.2 | OCTET STRING | read-only | Product Name |
| OCT systemSerial | 1.3.6.1.4.1.5951.6.2.16 | OCTET STRING | read-only | Serial Number |
| IP systemSvmIPAddress | 1.3.6.1.4.1.5951.6.2.5 | InetAddress | read-only | Management Service IP Address |
| IPt systemSvmIPAddressType | 1.3.6.1.4.1.5951.6.2.4 | InetAddressType | read-only | Type of systemSvmIPAddress |
| OCT systemSysId | 1.3.6.1.4.1.5951.6.2.15 | OCTET STRING | read-only | System Id |
| NTF systemTempError | 1.3.6.1.4.1.5951.6.1.2.23 | System temperature error; entityName and eventMessage show specific failure information | ||
| NTF systemTempNormal | 1.3.6.1.4.1.5951.6.1.2.24 | System temperature has returned to normal | ||
| OCT systemUptime | 1.3.6.1.4.1.5951.6.2.18 | OCTET STRING | read-only | Uptime |
| IP systemXenIPAddress | 1.3.6.1.4.1.5951.6.2.7 | InetAddress | read-only | XenServer IP Address |
| IPt systemXenIPAddressType | 1.3.6.1.4.1.5951.6.2.6 | InetAddressType | read-only | Type of systemXenIPAddress |
| OCT thresholdValue | 1.3.6.1.4.1.5951.6.1.1.5 | OCTET STRING | accessible-for-notify | High threshold value configured for this alarm |
| NTF trapConfigFailure | 1.3.6.1.4.1.5951.6.1.2.78 | This trap is sent when failure occurs in adding snmp trap destination | ||
| NTF versionMatrixMisMatch | 1.3.6.1.4.1.5951.6.1.2.75 | This trap is sent when version matrix mismatch is detected | ||
| NTF voltageError | 1.3.6.1.4.1.5951.6.1.2.25 | Voltage error; entityName and eventMessage show specific failure information | ||
| NTF voltageNormal | 1.3.6.1.4.1.5951.6.1.2.26 | Voltage has returned to normal | ||
| NTF xenApiFailed | 1.3.6.1.4.1.5951.6.1.2.9 | XenAPI communication between the Management Service and XenServer has failed | ||
| NTF xenApiNormal | 1.3.6.1.4.1.5951.6.1.2.10 | XenAPI communication between the Management Service and XenServer has returned to normal | ||
| OCT xenBuildDate | 1.3.6.1.4.1.5951.6.3.1.1.24 | OCTET STRING | read-only | XenServer Build Date |
| OCT xenBuildNumber | 1.3.6.1.4.1.5951.6.3.1.1.23 | OCTET STRING | read-only | XenServer Build Number |
| OCT xenCpuUsage | 1.3.6.1.4.1.5951.6.3.1.1.8 | OCTET STRING | read-only | CPU Usage (%) of host |
| OCT xenDescription | 1.3.6.1.4.1.5951.6.3.1.1.4 | OCTET STRING | read-only | Description of managed device |
| OCT xenEdition | 1.3.6.1.4.1.5951.6.3.1.1.17 | OCTET STRING | read-only | XenServer Edition |
| xenEntry | 1.3.6.1.4.1.5951.6.3.1.1 | not-accessible | ... | |
| OCT xenExpiry | 1.3.6.1.4.1.5951.6.3.1.1.18 | OCTET STRING | read-only | XenServer Expiry |
| OCT xenHostname | 1.3.6.1.4.1.5951.6.3.1.1.3 | OCTET STRING | read-only | Assign hostname to managed device, if this is not provided, name will be set as host name |
| NTF xenHttpFailed | 1.3.6.1.4.1.5951.6.1.2.5 | HTTP communication between the Management Service and XenServer has failed | ||
| NTF xenHttpNormal | 1.3.6.1.4.1.5951.6.1.2.6 | HTTP communication between the Management Service and XenServer has returned to normal | ||
| IP xenIpAddress | 1.3.6.1.4.1.5951.6.3.1.1.2 | InetAddress | read-only | IP Address for this managed device |
| IPt xenIpAddressType | 1.3.6.1.4.1.5951.6.3.1.1.1 | InetAddressType | read-only | Type of xenIpAddress |
| OCT xenIscsiIQN | 1.3.6.1.4.1.5951.6.3.1.1.16 | OCTET STRING | read-only | iSCSI IQN |
| OCT xenMemoryFree | 1.3.6.1.4.1.5951.6.3.1.1.10 | OCTET STRING | read-only | Free memory available (MB) in host |
| OCT xenMemoryTotal | 1.3.6.1.4.1.5951.6.3.1.1.9 | OCTET STRING | read-only | Total memory of host in MB |
| OCT xenMemoryUsage | 1.3.6.1.4.1.5951.6.3.1.1.11 | OCTET STRING | read-only | Memory Usage (%) of host |
| I32 xenNumberOfCPU | 1.3.6.1.4.1.5951.6.3.1.1.7 | Integer32 | read-only | Number of total CPU of host |
| NTF xenPingFailed | 1.3.6.1.4.1.5951.6.1.2.11 | ICMP Ping between the Management Service and XenServer has failed | ||
| NTF xenPingNormal | 1.3.6.1.4.1.5951.6.1.2.12 | ICMP Ping between the Management Service and XenServer has returned to normal | ||
| OCT xenProductCode | 1.3.6.1.4.1.5951.6.3.1.1.19 | OCTET STRING | read-only | XenServer Product Code |
| OCT xenRx | 1.3.6.1.4.1.5951.6.3.1.1.13 | OCTET STRING | read-only | In Throughput (Mbps) of host |
| OCT xenSerialNumber | 1.3.6.1.4.1.5951.6.3.1.1.20 | OCTET STRING | read-only | Device Serial Number |
| NTF xenSshFailed | 1.3.6.1.4.1.5951.6.1.2.7 | SSH communication between the Management Service and XenServer has failed | ||
| NTF xenSshNormal | 1.3.6.1.4.1.5951.6.1.2.8 | SSH communication between the Management Service and XenServer has returned to normal | ||
| I32 xenSslCoresTotal | 1.3.6.1.4.1.5951.6.3.1.1.15 | Integer32 | read-only | Total SSL Cores available in host |
| xenTable | 1.3.6.1.4.1.5951.6.3.1 | not-accessible | The SDX xentable | |
| OCT xenTx | 1.3.6.1.4.1.5951.6.3.1.1.12 | OCTET STRING | read-only | Out Throughput (Mbps) of host |
| OCT xenUptime | 1.3.6.1.4.1.5951.6.3.1.1.14 | OCTET STRING | read-only | Uptime of host |
| OCT xenUuid | 1.3.6.1.4.1.5951.6.3.1.1.6 | OCTET STRING | read-only | UUID of host |
| OCT xenVersion | 1.3.6.1.4.1.5951.6.3.1.1.5 | OCTET STRING | read-only | Device Version |
| OCT xenVersionLong | 1.3.6.1.4.1.5951.6.3.1.1.21 | OCTET STRING | read-only | XenServer Version (full text) |
| OCT xenVersionShort | 1.3.6.1.4.1.5951.6.3.1.1.22 | OCTET STRING | read-only | XenServer Version |
RFC description
Citrix Netscaler root MIB defining system, event groups, and platform information.
Start monitoring Citrix application delivery appliances with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.