SDX-ROOT-MIB

MIB Reference — IPNetwork Monitor

All MIBsSDX-ROOT-MIB

Organization: Citrix Systems, Inc.

Last Updated: 2013-12-05

Category: Citrix Application Delivery, Enterprise SMI and Registration

Description:

Defines the Citrix SDX enterprise root OID tree hierarchy for appliance MIB registration.

Imported Objects

From INET-ADDRESS-MIB

InetAddress
InetAddressType

From IPV6-TC

Ipv6Address

From SNMPv2-SMI

Counter32
Gauge32
Integer32
IpAddress
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-IDENTITY
OBJECT-TYPE
TimeTicks
enterprises

What Is SDX-ROOT-MIB?

SDX-ROOT-MIB is the enterprise root MIB for Citrix's NetScaler SDX (Service Delivery appliance) platform, defining the top-level OID tree and core system identification objects for the SDX management hypervisor layer. It exposes platform and product identity (systemPlatform, systemProduct, systemBuildNumber) as well as networking configuration for the SDX management components, including the SVM (management service VM) and Xen hypervisor IP addressing, netmask, and gateway settings. Its monitoring value centers on software/platform status and management-plane connectivity: confirming the correct build/version is running and that the SVM and Xen management interfaces are correctly addressed and reachable, which is foundational before deeper per-instance NetScaler VPX monitoring can occur. It serves as the root registration point for other SDX-specific MIB branches (such as sdxEventGroup for event/notification data) and depends on the standard SNMPv2-SMI enterprises arc. It is deployed on Citrix (NetScaler) SDX multi-tenant application delivery appliances that host multiple NetScaler VPX instances, and administrators typically perform an SDX-ROOT-MIB download from Citrix to load the module into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in SDX-ROOT-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

What Can Be Monitored

  • platform/product identity and build version
  • SVM management IP configuration
  • Xen hypervisor IP configuration
  • netmask and gateway settings
  • SDX event/notification registration

Supported Devices

  • Citrix (NetScaler) SDX multi-tenant application delivery appliances

Monitoring Examples

An administrator would poll systemProduct and systemBuildNumber to confirm the SDX appliance's software version, then check systemSvmIPAddress and systemXenIPAddress against systemNetmask and systemGateway to verify the management plane's networking is correctly configured. A mismatch or unreachable systemSvmIPAddress would indicate the SDX management service VM has a networking problem, which would block visibility into the hosted NetScaler VPX instances.

OIDs
OID symbolicOID numericTypeAccessDescription
netScaler1.3.6.1.4.1.5951The enterprise specific MIB for Netscaler NS10.0.
sdxRoot1.3.6.1.4.1.5951.6
sdxEventGroup1.3.6.1.4.1.5951.6.1
eventVarBindOids1.3.6.1.4.1.5951.6.1.1
OCT source1.3.6.1.4.1.5951.6.1.1.1OCTET STRINGaccessible-for-notifyIP address of the device generating the event
OCT entityName1.3.6.1.4.1.5951.6.1.1.2OCTET STRINGaccessible-for-notifyName of the entity associated with this alarm
OCT entityType1.3.6.1.4.1.5951.6.1.1.3OCTET STRINGaccessible-for-notifyType of entity associated with this alarm
OCT eventMessage1.3.6.1.4.1.5951.6.1.1.4OCTET STRINGaccessible-for-notifyMessage associated with this alarm
OCT thresholdValue1.3.6.1.4.1.5951.6.1.1.5OCTET STRINGaccessible-for-notifyHigh threshold value configured for this alarm
OCT currentValue1.3.6.1.4.1.5951.6.1.1.6OCTET STRINGaccessible-for-notifyCurrent value of the entity when high or normal threshold trap is sent
OCT severity1.3.6.1.4.1.5951.6.1.1.7OCTET STRINGaccessible-for-notifySeverity associated with this alarm
sdxEvents1.3.6.1.4.1.5951.6.1.2
NTF cpuUsageHigh1.3.6.1.4.1.5951.6.1.2.1CPU utilization has exceeded the high threshold value
NTF cpuUsageNormal1.3.6.1.4.1.5951.6.1.2.2CPU utilization has returned to normal
NTF memoryUsageHigh1.3.6.1.4.1.5951.6.1.2.3Memory utilization has exceeded the high threshold value. On SDX platform since memory for an instance is decided by the administrator, this trap is not raised
NTF memoryUsageNormal1.3.6.1.4.1.5951.6.1.2.4Memory utilization has returned to normal
NTF xenHttpFailed1.3.6.1.4.1.5951.6.1.2.5HTTP communication between the Management Service and XenServer has failed
NTF xenHttpNormal1.3.6.1.4.1.5951.6.1.2.6HTTP communication between the Management Service and XenServer has returned to normal
NTF xenSshFailed1.3.6.1.4.1.5951.6.1.2.7SSH communication between the Management Service and XenServer has failed
NTF xenSshNormal1.3.6.1.4.1.5951.6.1.2.8SSH communication between the Management Service and XenServer has returned to normal
NTF xenApiFailed1.3.6.1.4.1.5951.6.1.2.9XenAPI communication between the Management Service and XenServer has failed
NTF xenApiNormal1.3.6.1.4.1.5951.6.1.2.10XenAPI communication between the Management Service and XenServer has returned to normal
NTF xenPingFailed1.3.6.1.4.1.5951.6.1.2.11ICMP Ping between the Management Service and XenServer has failed
NTF xenPingNormal1.3.6.1.4.1.5951.6.1.2.12ICMP Ping between the Management Service and XenServer has returned to normal
NTF ipmiStateError1.3.6.1.4.1.5951.6.1.2.13Intelligent Platform Management Interface (IPMI) utility is missing
NTF ipmiStateNormal1.3.6.1.4.1.5951.6.1.2.14Intelligent Platform Management Interface (IPMI) utility is detected
NTF bmcFirmwareVersionError1.3.6.1.4.1.5951.6.1.2.15BMC firmware is missing or the version is not supported
NTF bmcFirmwareVersionNormal1.3.6.1.4.1.5951.6.1.2.16BMC firmware is detected or the version has returned to a supported version
NTF resourceStateError1.3.6.1.4.1.5951.6.1.2.17A hardware or software resource error has occurred; entityName and eventMessage show specific failure information
NTF resourceStateNormal1.3.6.1.4.1.5951.6.1.2.18The hardware or software resource error has been fixed and normal state has been restored; entityName and eventMessage show details
NTF fanSpeedError1.3.6.1.4.1.5951.6.1.2.19Fan speed is either high or low
NTF fanSpeedNormal1.3.6.1.4.1.5951.6.1.2.20Fan speed has returned to normal
NTF cpuTempError1.3.6.1.4.1.5951.6.1.2.21CPU temperature error; entityName and eventMessage show specific failure information
NTF cpuTempNormal1.3.6.1.4.1.5951.6.1.2.22CPU temperature has returned to normal
NTF systemTempError1.3.6.1.4.1.5951.6.1.2.23System temperature error; entityName and eventMessage show specific failure information
NTF systemTempNormal1.3.6.1.4.1.5951.6.1.2.24System temperature has returned to normal
NTF voltageError1.3.6.1.4.1.5951.6.1.2.25Voltage error; entityName and eventMessage show specific failure information
NTF voltageNormal1.3.6.1.4.1.5951.6.1.2.26Voltage has returned to normal
NTF powerSupplyFailed1.3.6.1.4.1.5951.6.1.2.27Power Supply error; entityName and eventMessage show specific failure information information
NTF powerSupplyNormal1.3.6.1.4.1.5951.6.1.2.28Power Supply has returned to normal condition
NTF healthCounterError1.3.6.1.4.1.5951.6.1.2.31Health Counter Error; entityName and eventMessage show specific failure information
NTF healthCounterNormal1.3.6.1.4.1.5951.6.1.2.32Health Counter Error condition has returned to normal; entityName and eventMessage show details
NTF interfaceDown1.3.6.1.4.1.5951.6.1.2.33A network interface has gone down; entityName and eventMessage show details
NTF interfaceUp1.3.6.1.4.1.5951.6.1.2.34The network interface has returned to UP state; entityName and eventMessage show details
NTF cpuAffinityRecoveryFailed1.3.6.1.4.1.5951.6.1.2.41CPU affinity recovery has failed
NTF cpuAffinityRecoverySuccess1.3.6.1.4.1.5951.6.1.2.42CPU affinity recovery is successful
NTF subSystemDown1.3.6.1.4.1.5951.6.1.2.43A subsystem has gone DOWN; entityName shows details
NTF subSystemUp1.3.6.1.4.1.5951.6.1.2.44A subsystem has returned to the UP state; entityName shows details
NTF subSystemFailed1.3.6.1.4.1.5951.6.1.2.45A subsystem has failed; entityName shows details
NTF mpsDown1.3.6.1.4.1.5951.6.1.2.46All subsystems are DOWN
NTF mpsUp1.3.6.1.4.1.5951.6.1.2.47All subsystems are UP
NTF passwordRecoveryFailed1.3.6.1.4.1.5951.6.1.2.48Password recovery has failed
NTF passwordRecoverySuccess1.3.6.1.4.1.5951.6.1.2.49Password has been recovered successfully
NTF deviceAdded1.3.6.1.4.1.5951.6.1.2.50A managed device has been added
NTF deviceRemoved1.3.6.1.4.1.5951.6.1.2.51A managed device has been removed
NTF deviceModified1.3.6.1.4.1.5951.6.1.2.52An attribute of a managed device has been changed
NTF devicePowerStateChanged1.3.6.1.4.1.5951.6.1.2.53Power state of a managed device has changed
NTF deviceStateChanged1.3.6.1.4.1.5951.6.1.2.54Instance state of a managed device has changed
NTF deviceBootFailed1.3.6.1.4.1.5951.6.1.2.55A managed device has failed to start
NTF deviceRebootFailed1.3.6.1.4.1.5951.6.1.2.56A managed device has failed to restart
NTF loginFailure1.3.6.1.4.1.5951.6.1.2.71This trap is sent when User Authentication fails. 'entityName' and 'eventMessage' will show specific failure information
NTF inventoryFailed1.3.6.1.4.1.5951.6.1.2.72XenServer inventory collection has failed
NTF healthMonitorPluginError1.3.6.1.4.1.5951.6.1.2.73This trap is sent when health monitor plugin (xsnsmonitor) is not installed on XenServer
NTF healthMonitorPluginNormal1.3.6.1.4.1.5951.6.1.2.74This trap is sent when health monitor plugin (xsnsmonitor) is back to installed state on XenServer
NTF versionMatrixMisMatch1.3.6.1.4.1.5951.6.1.2.75This trap is sent when version matrix mismatch is detected
NTF logicalDriveFailed1.3.6.1.4.1.5951.6.1.2.76Logical Drive Failed
NTF physicalDriveFailed1.3.6.1.4.1.5951.6.1.2.77Physical Drive Failed
NTF trapConfigFailure1.3.6.1.4.1.5951.6.1.2.78This trap is sent when failure occurs in adding snmp trap destination
systemGroup1.3.6.1.4.1.5951.6.2
OCT systemPlatform1.3.6.1.4.1.5951.6.2.1OCTET STRINGread-onlyPlatform
OCT systemProduct1.3.6.1.4.1.5951.6.2.2OCTET STRINGread-onlyProduct Name
OCT systemBuildNumber1.3.6.1.4.1.5951.6.2.3OCTET STRINGread-onlyBuild Number
IPt systemSvmIPAddressType1.3.6.1.4.1.5951.6.2.4InetAddressTyperead-onlyType of systemSvmIPAddress
IP systemSvmIPAddress1.3.6.1.4.1.5951.6.2.5InetAddressread-onlyManagement Service IP Address
IPt systemXenIPAddressType1.3.6.1.4.1.5951.6.2.6InetAddressTyperead-onlyType of systemXenIPAddress
IP systemXenIPAddress1.3.6.1.4.1.5951.6.2.7InetAddressread-onlyXenServer IP Address
IPt systemNetmaskType1.3.6.1.4.1.5951.6.2.8InetAddressTyperead-onlyType of systemNetmask
IP systemNetmask1.3.6.1.4.1.5951.6.2.9InetAddressread-onlyNetmask
IPt systemGatewayType1.3.6.1.4.1.5951.6.2.10InetAddressTyperead-onlyType of systemGateway
IP systemGateway1.3.6.1.4.1.5951.6.2.11InetAddressread-onlyGateway
OCT systemNetworkInterface1.3.6.1.4.1.5951.6.2.12OCTET STRINGread-onlyInterface on which management needs to be enabled
IPt systemDnsType1.3.6.1.4.1.5951.6.2.13InetAddressTyperead-onlyType of systemDns
IP systemDns1.3.6.1.4.1.5951.6.2.14InetAddressread-onlyDNS Server
OCT systemSysId1.3.6.1.4.1.5951.6.2.15OCTET STRINGread-onlySystem Id
OCT systemSerial1.3.6.1.4.1.5951.6.2.16OCTET STRINGread-onlySerial Number
I32 systemCurrentTime1.3.6.1.4.1.5951.6.2.17Integer32read-onlyCurrent Time
OCT systemUptime1.3.6.1.4.1.5951.6.2.18OCTET STRINGread-onlyUptime
OCT systemBiosVersion1.3.6.1.4.1.5951.6.2.19OCTET STRINGread-onlyBIOS Version
OCT systemMaxThroughput1.3.6.1.4.1.5951.6.2.20OCTET STRINGread-onlyMaximum Throughput in Mbps
OCT systemAvailableThroughput1.3.6.1.4.1.5951.6.2.21OCTET STRINGread-onlyAvailable Throughput in Mbps
OCT systemHostId1.3.6.1.4.1.5951.6.2.22OCTET STRINGread-onlyHost Id
sysHealthGroup1.3.6.1.4.1.5951.6.2.1000
hardwareResourceTable1.3.6.1.4.1.5951.6.2.1000.1not-accessibleThe SDX hardwareResourcetable
hardwareResourceEntry1.3.6.1.4.1.5951.6.2.1000.1.1not-accessible...
OCT hardwareResourceName1.3.6.1.4.1.5951.6.2.1000.1.1.1OCTET STRINGread-onlyResource name
IPt hardwareResourceHostIPAddressType1.3.6.1.4.1.5951.6.2.1000.1.1.2InetAddressTyperead-onlyType of hardwareResourceHostIPAddress
IP hardwareResourceHostIPAddress1.3.6.1.4.1.5951.6.2.1000.1.1.3InetAddressread-onlyHost IP Address
OCT hardwareResourceCurrentValue1.3.6.1.4.1.5951.6.2.1000.1.1.4OCTET STRINGread-onlyCurrent value of the resource
OCT hardwareResourceExpectedValue1.3.6.1.4.1.5951.6.2.1000.1.1.5OCTET STRINGread-onlyExpected value of the resource
OCT hardwareResourceUnit1.3.6.1.4.1.5951.6.2.1000.1.1.6OCTET STRINGread-onlyMeasurement unit for the resource
OCT hardwareResourceStatus1.3.6.1.4.1.5951.6.2.1000.1.1.7OCTET STRINGread-onlyHealth status of the resource - OK/ERROR
softwareResourceTable1.3.6.1.4.1.5951.6.2.1000.2not-accessibleThe SDX softwareResourcetable
softwareResourceEntry1.3.6.1.4.1.5951.6.2.1000.2.1not-accessible...
OCT softwareResourceName1.3.6.1.4.1.5951.6.2.1000.2.1.1OCTET STRINGread-onlyResource name
IPt softwareResourceHostIPAddressType1.3.6.1.4.1.5951.6.2.1000.2.1.2InetAddressTyperead-onlyType of softwareResourceHostIPAddress
IP softwareResourceHostIPAddress1.3.6.1.4.1.5951.6.2.1000.2.1.3InetAddressread-onlyHost IP Address
OCT softwareResourceCurrentValue1.3.6.1.4.1.5951.6.2.1000.2.1.4OCTET STRINGread-onlyCurrent value of the resource
OCT softwareResourceExpectedValue1.3.6.1.4.1.5951.6.2.1000.2.1.5OCTET STRINGread-onlyExpected value of the resource
OCT softwareResourceUnit1.3.6.1.4.1.5951.6.2.1000.2.1.6OCTET STRINGread-onlyMeasurement unit for the resource
OCT softwareResourceStatus1.3.6.1.4.1.5951.6.2.1000.2.1.7OCTET STRINGread-onlyHealth status of the resource - OK/ERROR
diskTable1.3.6.1.4.1.5951.6.2.1000.3not-accessibleThe SDX disktable
diskEntry1.3.6.1.4.1.5951.6.2.1000.3.1not-accessible...
OCT diskName1.3.6.1.4.1.5951.6.2.1000.3.1.1OCTET STRINGread-onlyName of the Disk
IPt diskHostIPAddressType1.3.6.1.4.1.5951.6.2.1000.3.1.2InetAddressTyperead-onlyType of diskHostIPAddress
IP diskHostIPAddress1.3.6.1.4.1.5951.6.2.1000.3.1.3InetAddressread-onlyHost IP Address
OCT diskTransactionRate1.3.6.1.4.1.5951.6.2.1000.3.1.4OCTET STRINGread-onlyTransactions per second
OCT diskBlockReadRate1.3.6.1.4.1.5951.6.2.1000.3.1.5OCTET STRINGread-onlyBlocks read per second
OCT diskBlockWriteRate1.3.6.1.4.1.5951.6.2.1000.3.1.6OCTET STRINGread-onlyBlocks written per second
OCT diskTotalBlocksRead1.3.6.1.4.1.5951.6.2.1000.3.1.7OCTET STRINGread-onlyTotal blocks read
OCT diskTotalBlocksWritten1.3.6.1.4.1.5951.6.2.1000.3.1.8OCTET STRINGread-onlyTotal blocks written
OCT diskUtilized1.3.6.1.4.1.5951.6.2.1000.3.1.9OCTET STRINGread-onlyUtilization of the disk (bytes)
OCT diskSize1.3.6.1.4.1.5951.6.2.1000.3.1.10OCTET STRINGread-onlySize of the disk (bytes)
I32 diskBayNumber1.3.6.1.4.1.5951.6.2.1000.3.1.11Integer32read-onlyBay number
srTable1.3.6.1.4.1.5951.6.2.1000.4not-accessibleThe SDX srtable
srEntry1.3.6.1.4.1.5951.6.2.1000.4.1not-accessible...
OCT srName1.3.6.1.4.1.5951.6.2.1000.4.1.1OCTET STRINGread-onlyName of the storage repository
OCT srBayNumber1.3.6.1.4.1.5951.6.2.1000.4.1.2OCTET STRINGread-onlyBay number
IPt srHostIPAddressType1.3.6.1.4.1.5951.6.2.1000.4.1.3InetAddressTyperead-onlyType of srHostIPAddress
IP srHostIPAddress1.3.6.1.4.1.5951.6.2.1000.4.1.4InetAddressread-onlyHost IP Address
OCT srUtilized1.3.6.1.4.1.5951.6.2.1000.4.1.5OCTET STRINGread-onlyPhysical utilization of the storage repository
OCT srSize1.3.6.1.4.1.5951.6.2.1000.4.1.6OCTET STRINGread-onlyPhysical size of the storage repository
OCT srStatus1.3.6.1.4.1.5951.6.2.1000.4.1.7OCTET STRINGread-onlyStatus of the storage repository - OK/ERROR
interfaceTable1.3.6.1.4.1.5951.6.2.1000.5not-accessibleThe SDX interfacetable
interfaceEntry1.3.6.1.4.1.5951.6.2.1000.5.1not-accessible...
OCT interfacePort1.3.6.1.4.1.5951.6.2.1000.5.1.1OCTET STRINGread-onlyPort Name Ex: 10/1
IPt interfaceHostIPAddressType1.3.6.1.4.1.5951.6.2.1000.5.1.2InetAddressTyperead-onlyType of interfaceHostIPAddress
IP interfaceHostIPAddress1.3.6.1.4.1.5951.6.2.1000.5.1.3InetAddressread-onlyHost IP Address
OCT interfaceState1.3.6.1.4.1.5951.6.2.1000.5.1.4OCTET STRINGread-onlyState of the Interface - UP/DOWN
OCT interfaceRxPackets1.3.6.1.4.1.5951.6.2.1000.5.1.5OCTET STRINGread-onlyReceived packets
OCT interfaceTxPackets1.3.6.1.4.1.5951.6.2.1000.5.1.6OCTET STRINGread-onlyTransmitted packets
OCT interfaceRxBytes1.3.6.1.4.1.5951.6.2.1000.5.1.7OCTET STRINGread-onlyReceived bytes
OCT interfaceTxBytes1.3.6.1.4.1.5951.6.2.1000.5.1.8OCTET STRINGread-onlyTransmitted bytes
OCT interfaceRxErrors1.3.6.1.4.1.5951.6.2.1000.5.1.9OCTET STRINGread-onlyReceiving errors
OCT interfaceTxErrors1.3.6.1.4.1.5951.6.2.1000.5.1.10OCTET STRINGread-onlyTransmission errors
I32 interfaceVfTotal1.3.6.1.4.1.5951.6.2.1000.5.1.11Integer32read-onlyTotal Virtual Functions
I32 interfaceVfAssigned1.3.6.1.4.1.5951.6.2.1000.5.1.12Integer32read-onlyAssigned Virtual Functions
OCT interfaceMappedPort1.3.6.1.4.1.5951.6.2.1000.5.1.13OCTET STRINGread-onlyMapped Port Name Ex: eth0
deviceGroup1.3.6.1.4.1.5951.6.3
xenTable1.3.6.1.4.1.5951.6.3.1not-accessibleThe SDX xentable
xenEntry1.3.6.1.4.1.5951.6.3.1.1not-accessible...
IPt xenIpAddressType1.3.6.1.4.1.5951.6.3.1.1.1InetAddressTyperead-onlyType of xenIpAddress
IP xenIpAddress1.3.6.1.4.1.5951.6.3.1.1.2InetAddressread-onlyIP Address for this managed device
OCT xenHostname1.3.6.1.4.1.5951.6.3.1.1.3OCTET STRINGread-onlyAssign hostname to managed device, if this is not provided, name will be set as host name
OCT xenDescription1.3.6.1.4.1.5951.6.3.1.1.4OCTET STRINGread-onlyDescription of managed device
OCT xenVersion1.3.6.1.4.1.5951.6.3.1.1.5OCTET STRINGread-onlyDevice Version
OCT xenUuid1.3.6.1.4.1.5951.6.3.1.1.6OCTET STRINGread-onlyUUID of host
I32 xenNumberOfCPU1.3.6.1.4.1.5951.6.3.1.1.7Integer32read-onlyNumber of total CPU of host
OCT xenCpuUsage1.3.6.1.4.1.5951.6.3.1.1.8OCTET STRINGread-onlyCPU Usage (%) of host
OCT xenMemoryTotal1.3.6.1.4.1.5951.6.3.1.1.9OCTET STRINGread-onlyTotal memory of host in MB
OCT xenMemoryFree1.3.6.1.4.1.5951.6.3.1.1.10OCTET STRINGread-onlyFree memory available (MB) in host
OCT xenMemoryUsage1.3.6.1.4.1.5951.6.3.1.1.11OCTET STRINGread-onlyMemory Usage (%) of host
OCT xenTx1.3.6.1.4.1.5951.6.3.1.1.12OCTET STRINGread-onlyOut Throughput (Mbps) of host
OCT xenRx1.3.6.1.4.1.5951.6.3.1.1.13OCTET STRINGread-onlyIn Throughput (Mbps) of host
OCT xenUptime1.3.6.1.4.1.5951.6.3.1.1.14OCTET STRINGread-onlyUptime of host
I32 xenSslCoresTotal1.3.6.1.4.1.5951.6.3.1.1.15Integer32read-onlyTotal SSL Cores available in host
OCT xenIscsiIQN1.3.6.1.4.1.5951.6.3.1.1.16OCTET STRINGread-onlyiSCSI IQN
OCT xenEdition1.3.6.1.4.1.5951.6.3.1.1.17OCTET STRINGread-onlyXenServer Edition
OCT xenExpiry1.3.6.1.4.1.5951.6.3.1.1.18OCTET STRINGread-onlyXenServer Expiry
OCT xenProductCode1.3.6.1.4.1.5951.6.3.1.1.19OCTET STRINGread-onlyXenServer Product Code
OCT xenSerialNumber1.3.6.1.4.1.5951.6.3.1.1.20OCTET STRINGread-onlyDevice Serial Number
OCT xenVersionLong1.3.6.1.4.1.5951.6.3.1.1.21OCTET STRINGread-onlyXenServer Version (full text)
OCT xenVersionShort1.3.6.1.4.1.5951.6.3.1.1.22OCTET STRINGread-onlyXenServer Version
OCT xenBuildNumber1.3.6.1.4.1.5951.6.3.1.1.23OCTET STRINGread-onlyXenServer Build Number
OCT xenBuildDate1.3.6.1.4.1.5951.6.3.1.1.24OCTET STRINGread-onlyXenServer Build Date
netscalerTable1.3.6.1.4.1.5951.6.3.2not-accessibleThe SDX netscalertable
netscalerEntry1.3.6.1.4.1.5951.6.3.2.1not-accessible...
IPt nsIpAddressType1.3.6.1.4.1.5951.6.3.2.1.1InetAddressTyperead-onlyType of nsIpAddress
IP nsIpAddress1.3.6.1.4.1.5951.6.3.2.1.2InetAddressread-onlyIP Address for this managed device
IPt nsHostIPAddressType1.3.6.1.4.1.5951.6.3.2.1.3InetAddressTyperead-onlyType of nsHostIPAddress
IP nsHostIPAddress1.3.6.1.4.1.5951.6.3.2.1.4InetAddressread-onlyHost IPAddress where VM is provisioned
OCT nsProfileName1.3.6.1.4.1.5951.6.3.2.1.5OCTET STRINGread-onlyDevice Profile Name that is attached with this managed device
OCT nsName1.3.6.1.4.1.5951.6.3.2.1.6OCTET STRINGread-onlyName of managed device
IPt nsNetmaskType1.3.6.1.4.1.5951.6.3.2.1.7InetAddressTyperead-onlyType of nsNetmask
IP nsNetmask1.3.6.1.4.1.5951.6.3.2.1.8InetAddressread-onlyNetmask of managed device
IPt nsGatewayType1.3.6.1.4.1.5951.6.3.2.1.9InetAddressTyperead-onlyType of nsGateway
IP nsGateway1.3.6.1.4.1.5951.6.3.2.1.10InetAddressread-onlyDefault Gateway of managed device
OCT nsHostname1.3.6.1.4.1.5951.6.3.2.1.11OCTET STRINGread-onlyAssign hostname to managed device, if this is not provided, name will be set as host name
OCT nsDescription1.3.6.1.4.1.5951.6.3.2.1.12OCTET STRINGread-onlyDescription of managed device
OCT nsVersion1.3.6.1.4.1.5951.6.3.2.1.13OCTET STRINGread-onlyDevice Version
OCT nsUuid1.3.6.1.4.1.5951.6.3.2.1.14OCTET STRINGread-onlyUUID of VM Instance
OCT nsInstanceState1.3.6.1.4.1.5951.6.3.2.1.15OCTET STRINGread-onlyState of device, UP only if device accessible
OCT nsVirtualFunctions1.3.6.1.4.1.5951.6.3.2.1.16OCTET STRINGread-onlyVirtual Functions assigned to VM Instance
OCT nsSslVirtualFunctions1.3.6.1.4.1.5951.6.3.2.1.17OCTET STRINGread-onlySSL Virtual Functions assigned to VM Instance
OCT nsVmState1.3.6.1.4.1.5951.6.3.2.1.18OCTET STRINGread-onlyState of Virtual Machine (Running | Halted)
I32 nsNumberOfCPU1.3.6.1.4.1.5951.6.3.2.1.19Integer32read-onlyNumber of CPU that is assigned to VM Instance
OCT nsVmMemoryTotal1.3.6.1.4.1.5951.6.3.2.1.21OCTET STRINGread-onlyTotal Memory of VM Instance in MB
OCT nsUptime1.3.6.1.4.1.5951.6.3.2.1.26OCTET STRINGread-onlyUptime of VM Instance
I32 nsNumberOfSSLCores1.3.6.1.4.1.5951.6.3.2.1.27Integer32read-onlyAssign number of ssl virtual functions to VM Instance
OCT nsCpuCoreMgmt1.3.6.1.4.1.5951.6.3.2.1.28OCTET STRINGread-onlyManagement CPU cores assigned to VM Instance
OCT nsCpuCorePE1.3.6.1.4.1.5951.6.3.2.1.29OCTET STRINGread-onlyPacket Engine cores assigned to VM Instance
OCT nsVmDescription1.3.6.1.4.1.5951.6.3.2.1.30OCTET STRINGread-onlyDescription
OCT nsThroughput1.3.6.1.4.1.5951.6.3.2.1.31OCTET STRINGread-onlyAssign throughput in Mbps to VM Instance
I32 nsNumberOfCores1.3.6.1.4.1.5951.6.3.2.1.32Integer32read-onlyNumber of cores that are assigned to VM Instance
OCT nsNsCPUUsage1.3.6.1.4.1.5951.6.3.2.1.33OCTET STRINGread-onlyCPU Usage (%) of NetScaler Instance
OCT nsNsMemoryUsage1.3.6.1.4.1.5951.6.3.2.1.35OCTET STRINGread-onlyMemory Usage (%)
OCT nsNsTx1.3.6.1.4.1.5951.6.3.2.1.36OCTET STRINGread-onlyOut Throughput of NetScaler Instance in Mbps
OCT nsNsRx1.3.6.1.4.1.5951.6.3.2.1.37OCTET STRINGread-onlyIn Throughput of NetScaler Instance in Mbps
OCT nsHttpReq1.3.6.1.4.1.5951.6.3.2.1.38OCTET STRINGread-onlyHTTP Requests/second
OCT nsUpsince1.3.6.1.4.1.5951.6.3.2.1.39OCTET STRINGread-onlyUpsince of NetScaler Instance
OCT nsLicense1.3.6.1.4.1.5951.6.3.2.1.40OCTET STRINGread-onlyFeature License for NetScaler Instance, needs to be set while provisioning (standard, enterprise, platinum)
OCT nsHaMasterState1.3.6.1.4.1.5951.6.3.2.1.41OCTET STRINGread-onlyMaster State (Primary/Secondary) of NetScaler Instance
IPt nsHaIPAddressType1.3.6.1.4.1.5951.6.3.2.1.42InetAddressTyperead-onlyType of nsHaIPAddress
IP nsHaIPAddress1.3.6.1.4.1.5951.6.3.2.1.43InetAddressread-onlyPeer IP Address of NetScaler Instance
OCT nsNodeState1.3.6.1.4.1.5951.6.3.2.1.44OCTET STRINGread-onlyNode State of NetScaler Instance
OCT nsHaSync1.3.6.1.4.1.5951.6.3.2.1.45OCTET STRINGread-onlyThe state of synchronization of NetScaler Instance
OCT nsPps1.3.6.1.4.1.5951.6.3.2.1.46OCTET STRINGread-onlyAssign packets per seconds to NetScaler Instance
I32 nsNumberOfSslCoresUp1.3.6.1.4.1.5951.6.3.2.1.47Integer32read-onlyNumber of SSL Cores Up
OCT nsIfOby11.3.6.1.4.1.5951.6.3.2.1.48OCTET STRINGread-onlyNetwork 0/1 on VM Instance
OCT nsIf0by21.3.6.1.4.1.5951.6.3.2.1.49OCTET STRINGread-onlyNetwork 0/2 on VM Instance
I32 nsNsVLANId1.3.6.1.4.1.5951.6.3.2.1.50Integer32read-onlyVLAN Id
OCT nsNsVLANTagged1.3.6.1.4.1.5951.6.3.2.1.51OCTET STRINGread-onlyNSVLAN Tagged
I32 nsVlanType1.3.6.1.4.1.5951.6.3.2.1.52Integer32read-onlyVLAN Type, NS or L2 VLAN
cloudBridgeInstanceTable1.3.6.1.4.1.5951.6.3.3not-accessibleThe SDX cloudBridgeInstancetable
cloudBridgeInstanceEntry1.3.6.1.4.1.5951.6.3.3.1not-accessible...
IPt cbIpAddressType1.3.6.1.4.1.5951.6.3.3.1.1InetAddressTyperead-onlyType of cbIpAddress
IP cbIpAddress1.3.6.1.4.1.5951.6.3.3.1.2InetAddressread-onlyIP Address for this managed device
IPt cbHostIPAddressType1.3.6.1.4.1.5951.6.3.3.1.3InetAddressTyperead-onlyType of cbHostIPAddress
IP cbHostIPAddress1.3.6.1.4.1.5951.6.3.3.1.4InetAddressread-onlyHost IPAddress where VM is provisioned
OCT cbProfileName1.3.6.1.4.1.5951.6.3.3.1.5OCTET STRINGread-onlyDevice Profile Name that is attached with this managed device
OCT cbName1.3.6.1.4.1.5951.6.3.3.1.6OCTET STRINGread-onlyName of managed device
IPt cbNetmaskType1.3.6.1.4.1.5951.6.3.3.1.7InetAddressTyperead-onlyType of cbNetmask
IP cbNetmask1.3.6.1.4.1.5951.6.3.3.1.8InetAddressread-onlyNetmask of managed device
IPt cbGatewayType1.3.6.1.4.1.5951.6.3.3.1.9InetAddressTyperead-onlyType of cbGateway
IP cbGateway1.3.6.1.4.1.5951.6.3.3.1.10InetAddressread-onlyDefault Gateway of managed device
OCT cbHostname1.3.6.1.4.1.5951.6.3.3.1.11OCTET STRINGread-onlyAssign hostname to managed device, if this is not provided, name will be set as host name
OCT cbDescription1.3.6.1.4.1.5951.6.3.3.1.12OCTET STRINGread-onlyDescription of managed device
OCT cbVersion1.3.6.1.4.1.5951.6.3.3.1.13OCTET STRINGread-onlyDevice Version
OCT cbInstanceState1.3.6.1.4.1.5951.6.3.3.1.14OCTET STRINGread-onlyState of device, UP only if device accessible
OCT cbUuid1.3.6.1.4.1.5951.6.3.3.1.15OCTET STRINGread-onlyUUID of VM Instance
OCT cbVirtualFunctions1.3.6.1.4.1.5951.6.3.3.1.16OCTET STRINGread-onlyVirtual Functions assigned to VM Instance
OCT cbVmState1.3.6.1.4.1.5951.6.3.3.1.17OCTET STRINGread-onlyState of Virtual Machine (Running | Halted)
I32 cbNumberOfCPU1.3.6.1.4.1.5951.6.3.3.1.18Integer32read-onlyNumber of CPU that is assigned to VM Instance
OCT cbVmCPUUsage1.3.6.1.4.1.5951.6.3.3.1.19OCTET STRINGread-onlyCPU Usage (%) of VM Instance
OCT cbVmMemoryTotal1.3.6.1.4.1.5951.6.3.3.1.20OCTET STRINGread-onlyTotal Memory of VM Instance in MB
OCT cbVmMemoryFree1.3.6.1.4.1.5951.6.3.3.1.21OCTET STRINGread-onlyFree Memory (MB) available in VM Instance
OCT cbVmMemoryUsage1.3.6.1.4.1.5951.6.3.3.1.22OCTET STRINGread-onlyMemory Usage (%) of VM Instance
OCT cbUptime1.3.6.1.4.1.5951.6.3.3.1.25OCTET STRINGread-onlyUptime of VM Instance
OCT cbDiskAllocation1.3.6.1.4.1.5951.6.3.3.1.30OCTET STRINGread-onlyDisk allocation for VM Instance
IPt cbAPAIPADDRESSType1.3.6.1.4.1.5951.6.3.3.1.47InetAddressTyperead-onlyType of cbAPAIPADDRESS
IP cbAPAIPADDRESS1.3.6.1.4.1.5951.6.3.3.1.48InetAddressread-onlyaPA IP Address
IPt cbAPANetMaskType1.3.6.1.4.1.5951.6.3.3.1.49InetAddressTyperead-onlyType of cbAPANetMask
IP cbAPANetMask1.3.6.1.4.1.5951.6.3.3.1.50InetAddressread-onlyaPA Netmask
IPt cbAPAGatewayType1.3.6.1.4.1.5951.6.3.3.1.51InetAddressTyperead-onlyType of cbAPAGateway
IP cbAPAGateway1.3.6.1.4.1.5951.6.3.3.1.52InetAddressread-onlyaPA Gateway
IPt cbPluginIPADDRESSType1.3.6.1.4.1.5951.6.3.3.1.53InetAddressTyperead-onlyType of cbPluginIPADDRESS
IP cbPluginIPADDRESS1.3.6.1.4.1.5951.6.3.3.1.54InetAddressread-onlyPlugin IP Address
IPt cbMgmtIPAddressType1.3.6.1.4.1.5951.6.3.3.1.57InetAddressTyperead-onlyType of cbMgmtIPAddress
IP cbMgmtIPAddress1.3.6.1.4.1.5951.6.3.3.1.58InetAddressread-onlyManagement IP Address for this CloudBridge
cloudBridgeAcceleratorTable1.3.6.1.4.1.5951.6.3.4not-accessibleThe SDX cloudBridgeAcceleratortable
cloudBridgeAcceleratorEntry1.3.6.1.4.1.5951.6.3.4.1not-accessible...
IPt cbAcceleratorIpAddressType1.3.6.1.4.1.5951.6.3.4.1.1InetAddressTyperead-onlyType of cbAcceleratorIpAddress
IP cbAcceleratorIpAddress1.3.6.1.4.1.5951.6.3.4.1.2InetAddressread-onlyIP Address for this managed device
IPt cbAcceleratorHostIPAddressType1.3.6.1.4.1.5951.6.3.4.1.3InetAddressTyperead-onlyType of cbAcceleratorHostIPAddress
IP cbAcceleratorHostIPAddress1.3.6.1.4.1.5951.6.3.4.1.4InetAddressread-onlyHost IPAddress where VM is provisioned
OCT cbAcceleratorProfileName1.3.6.1.4.1.5951.6.3.4.1.5OCTET STRINGread-onlyDevice Profile Name that is attached with this managed device
OCT cbAcceleratorName1.3.6.1.4.1.5951.6.3.4.1.6OCTET STRINGread-onlyName of managed device
IPt cbAcceleratorNetmaskType1.3.6.1.4.1.5951.6.3.4.1.7InetAddressTyperead-onlyType of cbAcceleratorNetmask
IP cbAcceleratorNetmask1.3.6.1.4.1.5951.6.3.4.1.8InetAddressread-onlyNetmask of managed device
IPt cbAcceleratorGatewayType1.3.6.1.4.1.5951.6.3.4.1.9InetAddressTyperead-onlyType of cbAcceleratorGateway
IP cbAcceleratorGateway1.3.6.1.4.1.5951.6.3.4.1.10InetAddressread-onlyDefault Gateway of managed device
OCT cbAcceleratorHostname1.3.6.1.4.1.5951.6.3.4.1.11OCTET STRINGread-onlyAssign hostname to managed device, if this is not provided, name will be set as host name
OCT cbAcceleratorDescription1.3.6.1.4.1.5951.6.3.4.1.12OCTET STRINGread-onlyDescription of managed device
OCT cbAcceleratorVersion1.3.6.1.4.1.5951.6.3.4.1.13OCTET STRINGread-onlyDevice Version
OCT cbAcceleratorInstanceState1.3.6.1.4.1.5951.6.3.4.1.14OCTET STRINGread-onlyState of device, UP only if device accessible
OCT cbAcceleratorUuid1.3.6.1.4.1.5951.6.3.4.1.15OCTET STRINGread-onlyUUID of VM Instance
OCT cbAcceleratorVmState1.3.6.1.4.1.5951.6.3.4.1.16OCTET STRINGread-onlyState of Virtual Machine (Running | Halted)
I32 cbAcceleratorNumberOfCPU1.3.6.1.4.1.5951.6.3.4.1.17Integer32read-onlyNumber of CPU that is assigned to VM Instance
OCT cbAcceleratorVmCPUUsage1.3.6.1.4.1.5951.6.3.4.1.18OCTET STRINGread-onlyCPU Usage (%) of VM Instance
OCT cbAcceleratorVmMemoryTotal1.3.6.1.4.1.5951.6.3.4.1.19OCTET STRINGread-onlyTotal Memory of VM Instance in MB
OCT cbAcceleratorVmMemoryFree1.3.6.1.4.1.5951.6.3.4.1.20OCTET STRINGread-onlyFree Memory (MB) available in VM Instance
OCT cbAcceleratorVmMemoryUsage1.3.6.1.4.1.5951.6.3.4.1.21OCTET STRINGread-onlyMemory Usage (%) of VM Instance
OCT cbAcceleratorUptime1.3.6.1.4.1.5951.6.3.4.1.24OCTET STRINGread-onlyUptime of VM Instance
OCT cbAcceleratorIpList1.3.6.1.4.1.5951.6.3.4.1.31OCTET STRINGread-onlySpecify the list of CloudBridge IPs for which this device will act as a CloudBridge Accelerator.
IPt cbAcceleratorMgmtIPAddressType1.3.6.1.4.1.5951.6.3.4.1.38InetAddressTyperead-onlyType of cbAcceleratorMgmtIPAddress
IP cbAcceleratorMgmtIPAddress1.3.6.1.4.1.5951.6.3.4.1.39InetAddressread-onlyManagement IP Address for this CloudBridge Accelerator Instance

RFC description

Citrix Netscaler root MIB defining system, event groups, and platform information.

Start monitoring Citrix application delivery appliances with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download SDX-ROOT-MIB