| OID symbolic | OID numeric | Type | Access | Description |
| schleifenbauer | 1.3.6.1.4.1.31034 | | | This MIB describes the functions of the Schleifenbauer device
family. |
| device0 | 1.3.6.1.4.1.31034.2 | | | |
| identification | 1.3.6.1.4.1.31034.2.3 | | | |
| I32 spdmVersion | 1.3.6.1.4.1.31034.2.3.1 | Integer32 | read-only | Data model version, currently 1.10 |
| I32 firmwareVersion | 1.3.6.1.4.1.31034.2.3.2 | Integer32 | read-only | The units firmware revision number. |
| STR buildNumber | 1.3.6.1.4.1.31034.2.3.3 | DisplayString | read-only | Date and time of latest build of the firmware. |
| STR salesOrderNumber | 1.3.6.1.4.1.31034.2.3.4 | DisplayString | read-only | SP sales order number. |
| STR productId | 1.3.6.1.4.1.31034.2.3.5 | DisplayString | read-only | SP product id. |
| STR serialNumber | 1.3.6.1.4.1.31034.2.3.6 | DisplayString | read-only | SP serial number. |
| STR hardwareAddress | 1.3.6.1.4.1.31034.2.3.7 | DisplayString | read-only | Hardware serial number; cannot be changed. Can be used as
backup unit address. format as 3 unsigned ints separated by
dashes: int - int - int |
| STR macAddress | 1.3.6.1.4.1.31034.2.3.8 | DisplayString | read-only | The ethernet interfaces unique hardware address. |
| I32 unitAddress | 1.3.6.1.4.1.31034.2.3.9 | Integer32 | read-write | User defined address; this will be used for addressing the
unit. |
| STR deviceName | 1.3.6.1.4.1.31034.2.3.10 | DisplayString | read-write | User configurable device name or identifier. |
| STR deviceLocation | 1.3.6.1.4.1.31034.2.3.11 | DisplayString | read-write | User configurable device location identifier. |
| STR vanityTag | 1.3.6.1.4.1.31034.2.3.12 | DisplayString | read-write | Characters to be displayed as vanity tekst in display. |
| configuration | 1.3.6.1.4.1.31034.2.4 | | | |
| I32 noPhases | 1.3.6.1.4.1.31034.2.4.1 | Integer32 | read-only | Either zero, one or three for no input metering, single or
three phase system |
| I32 noOutletsTotal | 1.3.6.1.4.1.31034.2.4.2 | Integer32 | read-only | Total number of outlets, even hardwired without switch/measure
modules. |
| I32 noSwitchedOutlets | 1.3.6.1.4.1.31034.2.4.3 | Integer32 | read-only | Number of switched outlets. If outlet numbering is
non-contiguous: the highest outlet number. |
| I32 noMeasuredOutlets | 1.3.6.1.4.1.31034.2.4.4 | Integer32 | read-only | Number of measured outlets. If outlet numbering is
non-contiguous: the highest outlet number. |
| I32 noSensors | 1.3.6.1.4.1.31034.2.4.5 | Integer32 | read-only | The number of external, digital environmental sensors: 0 for
none, 1 to 16 depending on number of reported sensors |
| I32 maximumLoad | 1.3.6.1.4.1.31034.2.4.6 | Integer32 | read-only | Maximum rated load of device per phase, usually either 16 or
32 A. |
| systemstatus | 1.3.6.1.4.1.31034.2.5 | | | |
| I32 deviceStatusCode | 1.3.6.1.4.1.31034.2.5.1 | Integer32 | read-only | Returns an internal status or error code. 0 = OK, 16 =
watchdog timer caused reset, 128 = slave module was reset, 144
= both previous. |
| I32 temperatureAlert | 1.3.6.1.4.1.31034.2.5.2 | Integer32 | read-only | An alert has been raised due to temperature exceeding
treshhold; 0= no alert; 1= internal unit temp, 2= external
sensor. |
| I32 inputCurrentAlert | 1.3.6.1.4.1.31034.2.5.3 | Integer32 | read-only | An alert has been raised due to current exceeding treshhold;
0=no alert; 1-3 for input phase. |
| I32 outputCurrentAlert | 1.3.6.1.4.1.31034.2.5.4 | Integer32 | read-only | An alert has been raised due to current exceeding treshhold;
0=no alert; 1-48 for outlet. |
| I32 inputVoltageAlert | 1.3.6.1.4.1.31034.2.5.5 | Integer32 | read-only | An alert has been raised due to a voltage dip; 0=no alert; 1-3
for input phase. |
| I32 oCurrentDropAlert | 1.3.6.1.4.1.31034.2.5.6 | Integer32 | read-only | An alert has been raised due to the current of a measured
outlet suddenly dropping to near zero, possibly indicating a
blown fuse; 0=no alert; 1-48 for outlet. |
| I32 iCurrentDropAlert | 1.3.6.1.4.1.31034.2.5.7 | Integer32 | read-only | An alert has been raised due to the current of a measured
input suddenly dropping to near zero, possibly indicating a
blown fuse; 0=no alert; 1-3 for phase. |
| reset | 1.3.6.1.4.1.31034.2.6 | | | |
| I32 rebootDevice | 1.3.6.1.4.1.31034.2.6.1 | Integer32 | read-write | Warm reboot/reset of device; note: this will have no effect on
outlet status! |
| I32 resetAlerts | 1.3.6.1.4.1.31034.2.6.2 | Integer32 | read-write | Reset all alert signals. |
| I32 zeroInputKWhSubtotal | 1.3.6.1.4.1.31034.2.6.3 | Integer32 | read-write | Reset of input kWh subtotal counters to zero. |
| I32 zeroOutKWhSubtotal | 1.3.6.1.4.1.31034.2.6.4 | Integer32 | read-write | Reset of outlet kWh subtotal counter to zero. |
| I32 resetPeakValues | 1.3.6.1.4.1.31034.2.6.5 | Integer32 | read-write | Reset all peak values to zero, as well input as output
metering, voltages dips, current peaks and temperatures. |
| settings | 1.3.6.1.4.1.31034.2.7 | | | |
| general | 1.3.6.1.4.1.31034.2.7.1 | | | |
| MIL peakDuration | 1.3.6.1.4.1.31034.2.7.1.4 | MilliSeconds | read-write | A current peak should last at least [stpkdr] MilliSeconds
before an alert is raised; max about a minute. |
| MIL fixedOutletDelay | 1.3.6.1.4.1.31034.2.7.1.5 | MilliSeconds | read-write | Minimal delay between two successive relay switches in
milliseconds. Minimal delay is 100 ms. Will always be
respected! |
| SEC powerSaverMode | 1.3.6.1.4.1.31034.2.7.1.6 | Seconds | read-write | Set backlight on time in seconds; 0 keeps display always on.
Note that keeping the backlight on may decrease luminosity over
time. Setting this to other values than 10, 60, 120 or 240 is
incompatible with the gateway! |
| I32 outletPowerupMode | 1.3.6.1.4.1.31034.2.7.1.7 | Integer32 | read-write | Behaviour of outlet on power-up: 0=off; 1=same state as at
power down; 2=same state, but delayed by individual delay
timer. |
| I32 maximumTemperature | 1.3.6.1.4.1.31034.2.7.1.8 | Integer32 | read-write | An alert should be generated whenever the temperature of the
first connected T sensor is above this value. Zero means
disabled. |
| I32 displayOrientation | 1.3.6.1.4.1.31034.2.7.1.9 | Integer32 | read-write | 0 no display; display off; 1 vertical, display on top; 2
vertical, upside down; 3 horizontal, display at left; 4
horizontal, display at right |
| I32 localAlertReset | 1.3.6.1.4.1.31034.2.7.1.10 | Integer32 | read-write | Allow alerts to be reset locally on device by pushing one of
the buttons. [replaces dipDuration] |
| I32 currentDropDetection | 1.3.6.1.4.1.31034.2.7.1.11 | Integer32 | read-write | Enables the current drop detection function. 0 = always off
(default), 1 = input (s) only, 2 = output(s) only, 3 = both
inputs and outputs. |
| I32 wirelessDisplayPower | 1.3.6.1.4.1.31034.2.7.1.12 | Integer32 | read-write | Controls the transit power of the wireless display transciever
(if installed). Set to zero to completely disable the module. |
| inputmeasuresTable | 1.3.6.1.4.1.31034.2.8 | | not-accessible | This table contains all measures related to the measured
inputs of the DEVICE. Note: either 1 or 3 channels, depending
on number of phases measured. |
| inputmeasuresEntry | 1.3.6.1.4.1.31034.2.8.1 | | not-accessible | The record containing the registers for the channel selected
by channelIndex. |
| I32 channelIndex6 | 1.3.6.1.4.1.31034.2.8.1.1 | Integer32 | not-accessible | The channel. Its value ranges between 1 and 48, depending on
the number of channels, usually 1. |
| KIL kWhTotalI | 1.3.6.1.4.1.31034.2.8.1.2 | KiloWattHour | read-only | Either the only phase in a single phase measurement; or one of
the three phases in a multiphase measurement. |
| KIL kWhSubtotalI | 1.3.6.1.4.1.31034.2.8.1.3 | KiloWattHour | read-only | kWh subtotal register of the only phase in a single phase
measurement; or one of three phases in a multiphase
measurement. Reset to zero with [rsimks]. |
| DEC powerFactorI | 1.3.6.1.4.1.31034.2.8.1.4 | DeciPowerFactor | read-only | The effective power factor in percent. |
| DEC actualCurrentI | 1.3.6.1.4.1.31034.2.8.1.5 | DeciAmps | read-only | Actual apparent, RMS current. |
| DEC peakCurrentI | 1.3.6.1.4.1.31034.2.8.1.6 | DeciAmps | read-only | Peak apparent, RMS current; highest value since last reset of
the alerts. |
| DEC actualVoltageI | 1.3.6.1.4.1.31034.2.8.1.7 | DeciVolts | read-only | The actual voltage. |
| DEC minVoltageI | 1.3.6.1.4.1.31034.2.8.1.8 | DeciVolts | read-only | RMS voltage dip; lowest value since reset of alerts. |
| I32 powerVAI | 1.3.6.1.4.1.31034.2.8.1.9 | Integer32 | read-only | Power value calculated, not in data model of device. |
| I32 powerWattI | 1.3.6.1.4.1.31034.2.8.1.10 | Integer32 | read-only | Power value calculated by the gateway, not in data model of
device. |
| DEC maxInletAmps | 1.3.6.1.4.1.31034.2.8.1.11 | DeciAmps | read-write | Maximum current per input phase in A; should last at least
[stpkdr] MilliSeconds before triggering an alert. |
| I32 inputCTratio | 1.3.6.1.4.1.31034.2.8.1.12 | Integer32 | read-write | The multiplier to use in case of use of /5 current
transformers. Defaults to 1. |
| STR inputName | 1.3.6.1.4.1.31034.2.8.1.13 | DisplayString | read-write | User configurable naming of inputs or phases. Useful if
channels are used to measure branches.. |
| outletsTable | 1.3.6.1.4.1.31034.2.9 | | not-accessible | This table contains the customer specific settings,
determining toutlestablehe behaviour of the DEVICE. |
| outletsEntry | 1.3.6.1.4.1.31034.2.9.1 | | not-accessible | The record containing the registers forthe channel selected by
channelIndex. |
| I32 channelIndex4 | 1.3.6.1.4.1.31034.2.9.1.1 | Integer32 | not-accessible | The channel. Its value ranges between 1 and 48, depending on
the number of channels, usually 1. |
| STR outletName | 1.3.6.1.4.1.31034.2.9.1.2 | DisplayString | read-only | User configurable naming of individual outlets. Useful to
distinguish outlets based on customer or device name. |
| outputmeasuresTable | 1.3.6.1.4.1.31034.2.10 | | not-accessible | This table contains all measures related to the measured
outputs of the DEVICE. Note: up to 48 channels, depending on
number of measured outlets. |
| outputmeasuresEntry | 1.3.6.1.4.1.31034.2.10.1 | | not-accessible | The record containing the registers for the channel selected
by channelIndex. |
| I32 channelIndex7 | 1.3.6.1.4.1.31034.2.10.1.1 | Integer32 | not-accessible | The channel. Its value ranges between 1 and 48, depending on
the number of channels, usually 1. |
| KIL kWhTotalO | 1.3.6.1.4.1.31034.2.10.1.2 | KiloWattHour | read-only | Total kWh of selected output. |
| KIL kWhSubtotalO | 1.3.6.1.4.1.31034.2.10.1.3 | KiloWattHour | read-only | kWh subtotal register of selected output. Reset to zero with
[rsomks]. |
| DEC powerFactorO | 1.3.6.1.4.1.31034.2.10.1.4 | DeciPowerFactor | read-only | Power factor of output. |
| DEC actualCurrentO | 1.3.6.1.4.1.31034.2.10.1.5 | DeciAmps | read-only | Actual apparent, RMS current. |
| DEC peakCurrentO | 1.3.6.1.4.1.31034.2.10.1.6 | DeciAmps | read-only | Peak apparent, RMS current; highest value since last reset of
alerts. |
| DEC actualVoltageO | 1.3.6.1.4.1.31034.2.10.1.7 | DeciVolts | read-only | Actual voltage on output. |
| DEC maxOutletAmps | 1.3.6.1.4.1.31034.2.10.1.8 | DeciAmps | read-write | Maximum current per outlet in A; should last at least [stpkdr]
MilliSeconds before triggering an alert. |
| I32 outputCTratio | 1.3.6.1.4.1.31034.2.10.1.9 | Integer32 | read-write | The multiplier to use in case of use of /5 current
transformers. Defaults to 1. |
| switchedoutletsTable | 1.3.6.1.4.1.31034.2.11 | | not-accessible | This table contains the current status of switchable
DEVICE's. |
| switchedoutletsEntry | 1.3.6.1.4.1.31034.2.11.1 | | not-accessible | The record containing the registers for the channel selected
by channelIndex. |
| I32 channelIndex5 | 1.3.6.1.4.1.31034.2.11.1.1 | Integer32 | not-accessible | The channel. Its value ranges between 1 and 48, depending on
the number of channels, usually 1. |
| I32 currentState | 1.3.6.1.4.1.31034.2.11.1.2 | Integer32 | read-write | The actual state of the outlet relays. The hardware will
contain max 48 outlets. Writing is only effective after setting
[swounl]. |
| I32 scheduled | 1.3.6.1.4.1.31034.2.11.1.3 | Integer32 | read-only | A one indicates pending activity; the switch delay has not yet
expired. |
| I32 unlock | 1.3.6.1.4.1.31034.2.11.1.4 | Integer32 | read-write | Setting the value to one will release the safety for this
outlet for a couple seconds; switching and rebooting are then
temporarily enabled. |
| SEC individualOutletDelay | 1.3.6.1.4.1.31034.2.11.1.5 | Seconds | read-write | Delay before an individual outlet switches on at power-up in
Seconds. |
| sensorTable | 1.3.6.1.4.1.31034.2.12 | | not-accessible | This table contains the environmental measurements. As well
internal temperature as external temperature probes. |
| sensorEntry | 1.3.6.1.4.1.31034.2.12.1 | | not-accessible | The record containing the registers for the channel selected
by channelIndex. |
| I32 channelIndex8 | 1.3.6.1.4.1.31034.2.12.1.1 | Integer32 | not-accessible | The channel. Its value ranges between 1 and 48, depending on
the number of channels, usually 1. |
| STR sensorType | 1.3.6.1.4.1.31034.2.12.1.2 | DisplayString | read-only | Type of connected sensor, either T, H or I for respectively
Temperature (C), Humidity (%) or dry switch contact |
| DEC sensorValue | 1.3.6.1.4.1.31034.2.12.1.3 | DeciValue | read-only | Value of connected sensor |
| STR sensorName | 1.3.6.1.4.1.31034.2.12.1.4 | DisplayString | read-write | User definable name for sensors. |
| compliances | 1.3.6.1.4.1.31034.99.1 | | | |
| compliance | 1.3.6.1.4.1.31034.99.1.1 | | | The requirements for conformance to the SPGW-MIB. |
| groups | 1.3.6.1.4.1.31034.99.2 | | | |
| identificationGroup | 1.3.6.1.4.1.31034.99.2.1 | | | A collection of objects providing identification information
about the device. |
| configurationGroup | 1.3.6.1.4.1.31034.99.2.2 | | | A collection of objects providing configuration information
about the device. |
| systemStatusGroup | 1.3.6.1.4.1.31034.99.2.3 | | | A collection of objects providing status information about the
device. |
| resetGroup | 1.3.6.1.4.1.31034.99.2.4 | | | Groups resettable attributes op the device. |
| settingsGroup | 1.3.6.1.4.1.31034.99.2.5 | | | A collection of objects providing the actual settings about
the device. |
| switchedOutletsGroup | 1.3.6.1.4.1.31034.99.2.6 | | | A collection of objects providing the actual outlet status of
the device. |
| inputMeasuresGroup | 1.3.6.1.4.1.31034.99.2.7 | | | A collection of objects providing the actual input
measurements of the device. |
| outputMeasuresGroup | 1.3.6.1.4.1.31034.99.2.8 | | | A collection of objects providing the actual output
measurements of the device. |
| sensorsGroup | 1.3.6.1.4.1.31034.99.2.9 | | | A collection of objects providing the actual environmental
measurements of the device. |