All MIBs › SDEVICE-MIB › fixedOutletDelay
fixedOutletDelay
Module: SDEVICE-MIB
OID (symbolic): SDEVICE-MIB::fixedOutletDelay
OID (numeric): 1.3.6.1.4.1.31034.2.7.1.5
Node type: OBJECT-TYPE
Type: MilliSeconds
Access: read-write
Description: Minimal delay between two successive relay switches in milliseconds. Minimal delay is 100 ms. Will always be respected!
What is fixedOutletDelay?
The minimum enforced delay, in milliseconds, between two successive relay switch operations on this device; the device always respects at least 100 ms regardless of configuration.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.31034.2.7.1.5 snmpwalk -v2c -c public <target> SDEVICE-MIB::fixedOutletDelay
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.31034.2.7.1.5.1 snmpget -v2c -c public <target> SDEVICE-MIB::fixedOutletDelay.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.31034.2.7.1.5.1 s <value>
Start monitoring Schleifenbauer Engineering intelligent PDUs (power capacity/temperature/current alerts) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SDEVICE-MIB::fixedOutletDelay OID value, configure state conditions and alerts, and monitor any Schleifenbauer Engineering intelligent PDUs (power capacity/temperature/current alerts) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.31034 | schleifenbauer | SDEVICE-MIB |
| 1.3.6.1.4.1.31034.2 | device0 | SDEVICE-MIB |
| 1.3.6.1.4.1.31034.2.7 | settings | SDEVICE-MIB |
| 1.3.6.1.4.1.31034.2.7.1 | general | SDEVICE-MIB |
| 1.3.6.1.4.1.31034.2.7.1.5 | fixedOutletDelay | SDEVICE-MIB |