All MIBs › REDLINE-AN50-MIB
Category: Wireless and Radio
Description: Provides management objects for Redline Communications AN50 WiMAX base station configuration and subscriber management.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is REDLINE-AN50-MIB?
REDLINE-AN50-MIB is a Redline Communications, Inc. (enterprise OID 10728) proprietary MIB for the AN-50 fixed-wireless broadband access platform, extending REDLINE-AN50-PMP-V1-MIB with general radio, security, and management configuration. Its objects cover uplink-burst-rate (UBR), RF-link selection, frequency, alignment mode, encryption/flow-control/HTTP/Telnet-access enable flags, Telnet port, options key, device-reset action, fault status, TX power, registered station/connection counts, active wireless-link count, channel auto-scan, IDU/ODU type, and companion Ethernet-side MAC address, gateway, port status, IP/mask, and 100Mbps-mode flag. As a configuration/status MIB it lets an administrator confirm RF link parameters (frequency, TX power, alignment) and how many subscriber stations are currently registered on an AN-50 base station. It is deployed on Redline Communications AN-50 fixed-wireless access platforms. Engineers can download the REDLINE-AN50-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in REDLINE-AN50-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Redline Communications AN-50 fixed-wireless access platforms
Monitoring Examples
An administrator checks an50GenRegisteredStations and an50GenTxPower to confirm subscriber capacity and transmit power on a Redline AN-50 fixed-wireless base station.
What Can Be Monitored
- RF link configuration and registered subscriber station count
This MIB depends on
Related MIBs
Imported Objects
| an50pmpLastMissedSsMacAddress | OBJECT-TYPE |
| an50pmpLastModifiedCID | OBJECT-TYPE |
| an50pmpLastRegisteredSsMacAddress | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| TimeTicks | |
| enterprises |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| redline | 1.3.6.1.4.1.10728 | |||
| NTF an50TftpFailTrap | 1.3.6.1.4.1.10728.0.1 | An event to report the failure of a Software Download. | ||
| NTF an50TftpSuccessTrap | 1.3.6.1.4.1.10728.0.2 | An event to report the success of a Software Download. | ||
| NTF an50PswdChangeFailTrap | 1.3.6.1.4.1.10728.0.3 | An event to report the failure of a password change. | ||
| NTF an50FirmwareConfigFailTrap | 1.3.6.1.4.1.10728.0.4 | An event to report the failure of a firmware config. | ||
| NTF an50EepromCorruptedTrap | 1.3.6.1.4.1.10728.0.5 | An event to report the corruption of the EEPROM. | ||
| NTF an50PowerSupplyFailureTrap | 1.3.6.1.4.1.10728.0.6 | An event to report the power supply failure. | ||
| NTF an50SaveConfigTrap | 1.3.6.1.4.1.10728.0.7 | An event to report the saving of configuration | ||
| NTF an50ModifiedIDTrap | 1.3.6.1.4.1.10728.0.8 | An event to report the modification in the configuration of a CID | ||
| NTF an50pmpRegistrationMissed | 1.3.6.1.4.1.10728.0.9 | An event to report the missing of the registration by a AN50 Subscriber to one BS.This trap is sent by the BS and contains the MAC address of the SS missing the registration | ||
| NTF an50pmpRegistrationSuccessful | 1.3.6.1.4.1.10728.0.10 | An event to report the successful registration of an AN50 Subscriber to BS. This trap is sent by the BS and contains the MAC address of the newly registered SS | ||
| NTF an50DFSEvent | 1.3.6.1.4.1.10728.0.11 | An event to report a dynamic frequency selection (DFS) event in AN50 | ||
| redlineProducts | 1.3.6.1.4.1.10728.1 | |||
| redlineMgmt | 1.3.6.1.4.1.10728.2 | |||
| redlineAn50 | 1.3.6.1.4.1.10728.2.16 | |||
| an50General | 1.3.6.1.4.1.10728.2.16.1 | |||
| INT an50GenUBR | 1.3.6.1.4.1.10728.2.16.1.1 | INTEGER | read-only | Indicates the system's current uncoded burst rate. With adaptive modulation enabled, this rate may change over time, depending on the prevailing propagation conditions. |
| INT an50GenRFLink | 1.3.6.1.4.1.10728.2.16.1.2 | INTEGER | read-only | connected(2) indicates the terminal is communicating properly to the remote terminal. notConnected(1) indicates there is no communication with the remote terminal. |
| INT an50GenFrequency | 1.3.6.1.4.1.10728.2.16.1.3 | INTEGER | read-write | The frequency which represents the operating channel of the link. The system can be configured to operate over 9 distinct channels. |
| INT an50GenAllignmentMode | 1.3.6.1.4.1.10728.2.16.1.4 | INTEGER | read-write | Specifies if the antenna alignment is done with buzzer or voltage. |
| INT an50GenEncryptionEnabled | 1.3.6.1.4.1.10728.2.16.1.5 | INTEGER | read-write | Specifies if encryption is enabled or not. |
| INT an50GenFlowControlEnabled | 1.3.6.1.4.1.10728.2.16.1.6 | INTEGER | read-write | This attribute specifies if flow control is enabled or not. |
| INT an50GenHttpAccessEnabled | 1.3.6.1.4.1.10728.2.16.1.7 | INTEGER | read-write | This attribute specifies if Http Access is enabled or not. |
| INT an50GenTelnetAccessEnabled | 1.3.6.1.4.1.10728.2.16.1.8 | INTEGER | read-write | This attribute specifies if Telnet Access is enabled or not. |
| INT an50GenTelnetPort | 1.3.6.1.4.1.10728.2.16.1.9 | INTEGER | read-write | This attribute specifies the Telnet port number. |
| OCT an50GenOptionsKey | 1.3.6.1.4.1.10728.2.16.1.10 | OCTET STRING | read-write | This attribute specifies the Product Options Key. |
| INT an50GenResetDevice | 1.3.6.1.4.1.10728.2.16.1.11 | INTEGER | read-write | reset(2) indicates to reset the AN50 terminal. donothing(1) indicates do not reset AN50 terminal. |
| INT an50GenFault | 1.3.6.1.4.1.10728.2.16.1.12 | INTEGER | read-only | The attribute specifies the Fault LED status of the terminal. |
| INT an50GenTxPower | 1.3.6.1.4.1.10728.2.16.1.13 | INTEGER | read-only | This object specifies the actual Tx Power of the AN-50 Node in ? |
| INT an50GenRegisteredStations | 1.3.6.1.4.1.10728.2.16.1.14 | INTEGER | read-only | This object specifies the actual number of configured links. |
| INT an50GenRegisteredConnections | 1.3.6.1.4.1.10728.2.16.1.15 | INTEGER | read-only | This object specifies the actual number of configured connections. |
| INT an50GenActiveWirelessLinks | 1.3.6.1.4.1.10728.2.16.1.16 | INTEGER | read-only | This object specifies the actual number of provisioned links. |
| INT an50GenChannelAutoScan | 1.3.6.1.4.1.10728.2.16.1.17 | INTEGER | read-write | This object specifies the Auto-Scanning feature for the channel. |
| INT an50GenIduType | 1.3.6.1.4.1.10728.2.16.1.18 | INTEGER | read-only | This object specifies the Indoor Unit Type. |
| INT an50GenOduType | 1.3.6.1.4.1.10728.2.16.1.19 | INTEGER | read-only | This object specifies the Outdoor Unit Type. |
| an50Config | 1.3.6.1.4.1.10728.2.16.2 | |||
| an50ConfigEther | 1.3.6.1.4.1.10728.2.16.2.1 | |||
| OCT an50EtherMacAddress | 1.3.6.1.4.1.10728.2.16.2.1.1 | OCTET STRING | read-only | This object specifies the Ethernet MAC address of the local terminal. |
| IP an50EtherGateway | 1.3.6.1.4.1.10728.2.16.2.1.2 | IpAddress | read-write | The IP Gateway of the AN-50 This field is used to specify the IP address of the gateway which the AN-50 is communicating through the core network. |
| INT an50EtherPortStatus | 1.3.6.1.4.1.10728.2.16.2.1.3 | INTEGER | read-only | The attribute specifies the status of the Ethernet Port of the AN50. |
| IP an50EtherIP | 1.3.6.1.4.1.10728.2.16.2.1.4 | IpAddress | read-write | The IP address of the AN-50. The default address from the factory is 192.168.25.2. For the initial set-up, the terminal should not be connected to the Internet network, i.e. the host computer should be connected directly to the terminal Ethernet port, to avoid address conflicts with other devices in a public network. Once the IP address has been set, the terminal can be connected to the core network, where it can receive either static or dynamic addressing (DHCP) in future configuration updates. |
| IP an50EtherMask | 1.3.6.1.4.1.10728.2.16.2.1.5 | IpAddress | read-write | The IP Subnet Mask of the AN-50. The value is typically set to 255.255.255.0 (Class C subnet), which prevents certain local devices from going out into the wireless network. |
| INT an50Ether100 | 1.3.6.1.4.1.10728.2.16.2.1.6 | INTEGER | read-only | This object specifies the 100 Mb/s Ethernet LED status of the AN50. |
| INT an50EtherFd | 1.3.6.1.4.1.10728.2.16.2.1.7 | INTEGER | read-only | The object specifies the Ethernet FullDuplex LED status of the AN50. |
| INT an50EtherMgmVidEn | 1.3.6.1.4.1.10728.2.16.2.1.8 | INTEGER | read-write | The attribute specifies the Ethernet Management Vlan Enabled Status of the AN50. |
| INT an50EtherMgmVid | 1.3.6.1.4.1.10728.2.16.2.1.9 | INTEGER | read-write | The attribute specifies the Ethernet Management Vlan Id of the AN50. |
| INT an50EtherLben | 1.3.6.1.4.1.10728.2.16.2.1.10 | INTEGER | read-write | The attribute specifies the Link Backup Enable Status of the AN50. |
| an50ConfigWireless | 1.3.6.1.4.1.10728.2.16.2.2 | |||
| INT an50WrlsChannel | 1.3.6.1.4.1.10728.2.16.2.2.1 | INTEGER | read-write | specifies the operating channel of the system, within the 100 MHz available in the 5.8GHz UNII band. To avoid interference, two PTP links operating in the same physical location (co-located) or within close proximity (e.g. across the street) must be separated by at least one channel, i.e. the gap between channels should be 20 MHz or more (e.g. channels 1 and 3). |
| INT an50WrlsTxPower | 1.3.6.1.4.1.10728.2.16.2.2.2 | INTEGER | read-write | The Tx Power of the AN-50 in dBm. Specifies the power level of the system, which is preset at the factory and should not be altered. In the event that this parameter needs to be changed, please contact the Redline support team. |
| INT an50WrlsModReduction | 1.3.6.1.4.1.10728.2.16.2.2.3 | INTEGER | read-write | The Modulation Reduction Level of the AN-50. Applies when the Adaptive rate is disabled. Specifies how many levels the system must drop in modulation before beginning re-transmission to address packet errors. The value can be set from 1-7, with 2 being the typical value. |
| INT an50WrlsAdaptiveMod | 1.3.6.1.4.1.10728.2.16.2.2.4 | INTEGER | read-write | Setting this attribute to AdaptiveRate(2) sets the system to operate in adaptive modulation mode. It is recommended to keep the AN-50 in this mode so that the system can automatically adjust the modulation level to the highest possible data rate based on measured RF performance. The user can define the minimum desired modulation level by setting the Main rate parameter. If the system meets this data rate, then the Signal LED on the front panel will light continuously green. If packet errors exceed one out of a million, the system will automatically lower the modulation level to maintain the link. In this case, the LED will flash green. If errors continue when the system reaches the lowest modulation level, the LED will flash red to indicate a failed RF link. The user can also disable the dynamic modulation mode by disabling Adaptive Modulation. In this mode, the user is required to set the Burst Rate and the Modulation Reduction Level. It is recommended not to operate the system in manual mode, as this mode is intended primarily for field support. Note the Signal LED will light solid green when the packet error rate is less than 1 out of a million. When the errors exceed this limit, the LED will not illuminate, indicating the RF link has failed. |
| INT an50WrlsUBR | 1.3.6.1.4.1.10728.2.16.2.2.5 | INTEGER | read-write | This object contains the desired net uncoded burst rate for the link. Set uncoded burst rate in steps (0=6Mb/s, 1=9Mb/s, 2=12Mb/s, 3=18Mb/s, 4=24Mb/s, 5=36Mb/s, 6=48Mb/s, 7=54Mbs). |
| INT an50WrlsMaster | 1.3.6.1.4.1.10728.2.16.2.2.6 | INTEGER | read-write | The object contains the configured mode of the AN50 terminal. 1 = PTP Slave, 2 = PTP Master, 3 = PMP Slave, 4 = PMP Master |
| INT an50WrlsVersion | 1.3.6.1.4.1.10728.2.16.2.2.7 | INTEGER | read-write | Sets the version of the AN50 system software. The software can be remotely downloaded into the AN50. The system comprises sufficient memory to hold two independent software loads. The operator can specify which load to set as the active version. |
| OCT an50WrlsEncryptCode | 1.3.6.1.4.1.10728.2.16.2.2.8 | OCTET STRING | read-write | The object contains the Encryption Key used for the AN-50 terminal. Enter the MAC address of the remote terminal to enable over-the-air data encryption. |
| INT an50WrlsCableAttenuation | 1.3.6.1.4.1.10728.2.16.2.2.9 | INTEGER | read-only | This object contains the Cable Attenuation for the AN-50 in dB. |
| INT an50WrlsRfPortStatus | 1.3.6.1.4.1.10728.2.16.2.2.10 | INTEGER | read-only | The object specifies the status of the AN50s Wireless Port. |
| INT an50WrlsSaveConfig | 1.3.6.1.4.1.10728.2.16.2.2.11 | INTEGER | read-write | The object saves the entire config set of the AN50. |
| INT an50WrlsActivateConfig | 1.3.6.1.4.1.10728.2.16.2.2.12 | INTEGER | read-write | The object activates the entire config set of the AN50. |
| INT an50WrlsRadioEnable | 1.3.6.1.4.1.10728.2.16.2.2.13 | INTEGER | read-write | The object specifies whether radio transmission is enabled or disabled. |
| INT an50WrlsRfStatusErrorCode | 1.3.6.1.4.1.10728.2.16.2.2.14 | INTEGER | read-only | The object specifies the Error Code for the RF Status. |
| INT an50WrlsRfSignal | 1.3.6.1.4.1.10728.2.16.2.2.15 | INTEGER | read-only | The object specifies the Wireless Signal LED status. |
| INT an50WrlsLLMode | 1.3.6.1.4.1.10728.2.16.2.2.16 | INTEGER | read-write | Link length set mode. |
| INT an50WrlsLMU | 1.3.6.1.4.1.10728.2.16.2.2.17 | INTEGER | read-write | This object specifies the Link measurements unit (mile / Km). |
| INT an50WrlsLL | 1.3.6.1.4.1.10728.2.16.2.2.18 | INTEGER | read-write | This object specifies the Link Length. See an50WrlsLMU object for units. |
| an50ConfigScheduler | 1.3.6.1.4.1.10728.2.16.2.2.19 | |||
| INT an50WrlsFrameSize | 1.3.6.1.4.1.10728.2.16.2.2.19.1 | INTEGER | read-write | This object specifies the size of wireless frame (DL+RTD+UL) in micro seconds. |
| INT an50WrlsMinBlockSize | 1.3.6.1.4.1.10728.2.16.2.2.19.2 | INTEGER | read-write | This object specifies a minimum number of bytes comprising transmitted block. |
| INT an50WrlsDownlinkSize | 1.3.6.1.4.1.10728.2.16.2.2.19.3 | INTEGER | read-write | This object specifies the size of downlink sub-frame in micro seconds. |
| INT an50WrlsRoundTripDelay | 1.3.6.1.4.1.10728.2.16.2.2.19.4 | INTEGER | read-write | This object specifies the round trip delay in micro seconds. |
| INT an50WrlsAdaptiveDLSize | 1.3.6.1.4.1.10728.2.16.2.2.19.5 | INTEGER | read-write | This object specifies if adaptive downlink size is enabled or disabled. |
| INT an50WrlsExtSyncronize | 1.3.6.1.4.1.10728.2.16.2.2.19.6 | INTEGER | read-write | This object specifies if external synchronization is enabled or disabled. |
| INT an50WrlsMaximumDistance | 1.3.6.1.4.1.10728.2.16.2.2.19.7 | INTEGER | read-write | This object specifies the maximum distance between base station and subscriber station in Km. |
| INT an50WrlsRegistrationPeriod | 1.3.6.1.4.1.10728.2.16.2.2.19.8 | INTEGER | read-write | This object specifies the number of frames between registration periods. |
| an50ConfigDefGroup | 1.3.6.1.4.1.10728.2.16.2.2.20 | |||
| INT an50WrlsBroadcastDLCIR | 1.3.6.1.4.1.10728.2.16.2.2.20.1 | INTEGER | read-write | This object specifies the broadcast downlink commited rate in kb/s. |
| INT an50WrlsBroadcastDLPIR | 1.3.6.1.4.1.10728.2.16.2.2.20.2 | INTEGER | read-write | This object specifies the broadcast downlink peak rate in kb/s. |
| INT an50WrlsDFSAction | 1.3.6.1.4.1.10728.2.16.2.2.21 | INTEGER | read-write | This object specifies the action taken when another system is detected on the same frequency |
| INT an50WrlsAntennaGain | 1.3.6.1.4.1.10728.2.16.2.2.22 | INTEGER | read-write | Antenna Gain in dB. |
| INT an50WrlsATPEnabled | 1.3.6.1.4.1.10728.2.16.2.2.23 | INTEGER | read-write | This object specifies if the Automatic Transmitted Power Control is enabled |
| an50Sw | 1.3.6.1.4.1.10728.2.16.2.3 | |||
| IP an50SwServer | 1.3.6.1.4.1.10728.2.16.2.3.1 | IpAddress | read-write | The address of the TFTP server used for software upgrades. If the address of the TFTP server is unknown, return 0.0.0.0. |
| OCT an50SwFilename | 1.3.6.1.4.1.10728.2.16.2.3.2 | OCTET STRING | read-write | The file name of the software image to be loaded into this device. |
| INT an50SwAdminStatus | 1.3.6.1.4.1.10728.2.16.2.3.3 | INTEGER | read-write | If set to upgrade(2), the device will initiate a TFTP software image download using an50SwFilename. If the download process is interrupted by a reset or power failure, the device will load the previous image. If set to noUpgrade(1), the device will revert to the previous version of the software. At initial startup, this object has the default value of noUpgrade(1). |
| INT an50SwOperStatus | 1.3.6.1.4.1.10728.2.16.2.3.4 | INTEGER | read-only | This object shows the download status. inProgress(1) indicates that a TFTP download is underway completeSuccess(2) indicates that the last software upgrade was successful failed(3) indicates that the last attempted download failed, ordinarily due to TFTP timeout. |
| OCT an50SwCurrentVers | 1.3.6.1.4.1.10728.2.16.2.3.5 | OCTET STRING | read-only | The software version currently operating in this device's flash. This object should be in the syntax used by the individual vendor to identify software versions. If it is not applicable, this MUST contain an empty string. |
| OCT an50SwOtherVers | 1.3.6.1.4.1.10728.2.16.2.3.6 | OCTET STRING | read-only | The software version in the secondary flash. This object should be in the syntax used by the individual vendor to identify software versions. If it is not applicable, this MUST contain an empty string. |
| an50Pm | 1.3.6.1.4.1.10728.2.16.3 | |||
| INT an50ResetStatistics | 1.3.6.1.4.1.10728.2.16.3.1 | INTEGER | read-write | A value of reset(2) resets the performance statistics on the AN-50, a value of donothing(1) does nothing. |
| an50PmEther | 1.3.6.1.4.1.10728.2.16.3.2 | |||
| CTR an50PmEtherRxPackets | 1.3.6.1.4.1.10728.2.16.3.2.1 | Counter | read-only | This object counts the number of ethernet packets successfully received by the local system. |
| CTR an50PmEtherRxPacketsErr | 1.3.6.1.4.1.10728.2.16.3.2.2 | Counter | read-only | This object counts the number of ethernet packet errors received by the local system. |
| CTR an50PmEtherTxPackets | 1.3.6.1.4.1.10728.2.16.3.2.3 | Counter | read-only | This object counts the number of Ethernet packets transmitted by the local system. |
| CTR an50PmEtherTxPacketsErr | 1.3.6.1.4.1.10728.2.16.3.2.4 | Counter | read-only | This object counts the number of Ethernet error packets transmitted by the local system. |
| CTR an50PmEtherRxPacketsDisc | 1.3.6.1.4.1.10728.2.16.3.2.5 | Counter | read-only | This object counts the number of ethernet packets discarded by receiver. |
| CTR an50PmEtherTxPacketsDisc | 1.3.6.1.4.1.10728.2.16.3.2.6 | Counter | read-only | This object counts the number of ethernet packets discarded by transmitter. |
| an50PmWrls | 1.3.6.1.4.1.10728.2.16.3.3 | |||
| INT an50PmWrlsRxSigMin | 1.3.6.1.4.1.10728.2.16.3.3.1 | INTEGER | read-only | This object indicates the minimum received signal strength measured since the last SNMP update. |
| INT an50PmWrlsRxSigMean | 1.3.6.1.4.1.10728.2.16.3.3.2 | INTEGER | read-only | This object indicates the average received signal strength measured since the last SNMP update. |
| INT an50PmWrlsRxSigMax | 1.3.6.1.4.1.10728.2.16.3.3.3 | INTEGER | read-only | This object indicates the maximum received signal strength measured since the last SNMP update |
| INT an50PmWrlsAvgSinAdr | 1.3.6.1.4.1.10728.2.16.3.3.4 | INTEGER | read-only | This object indicates the average signal to noise ratio measured since the last SNMP update. The ratio is based on the digital information provided from the output of the AtoD converter. |
| CTR an50PmWrlsRxPackets | 1.3.6.1.4.1.10728.2.16.3.3.5 | Counter | read-only | This object indicates the number of packets received over the air from the remote terminal. |
| CTR an50PmWrlsRxPacketsRetx | 1.3.6.1.4.1.10728.2.16.3.3.6 | Counter | read-only | This object indicates the number of packets retransmitted over the air from the remoter terminal. |
| CTR an50PmWrlsRxPacketsDisc | 1.3.6.1.4.1.10728.2.16.3.3.7 | Counter | read-only | This object indicates the number of packets, originating from the remote terminal lost over the air due to degradation in the RF link. |
| CTR an50PmWrlsTxPackets | 1.3.6.1.4.1.10728.2.16.3.3.8 | Counter | read-only | This object indicates the number of wireless packets (including Ethernet frames and error correction bytes) transmitted over the air by the local terminal. |
| CTR an50PmWrlsTxPacketsRetx | 1.3.6.1.4.1.10728.2.16.3.3.9 | Counter | read-only | This object indicates the number of packets retransmitted over the air by the local terminal. The retransmission scheme is based on the Acknowledge/Request (ARQ) algorithm that detects when packets are lost and makes a request to the MAC scheduler to repeat transmission of the lost packets. |
| CTR an50PmWrlsTxPacketsDisc | 1.3.6.1.4.1.10728.2.16.3.3.10 | Counter | read-only | This object indicates the total number of packets lost over the air due to degradation in the RF link. |
| INT an50PmWrlsCalcDst | 1.3.6.1.4.1.10728.2.16.3.3.11 | INTEGER | read-only | This object contains the calculated link distance. |
| an50Trap | 1.3.6.1.4.1.10728.2.16.4 | |||
| TIK an50SysLastTrapTime | 1.3.6.1.4.1.10728.2.16.4.1 | TimeTicks | read-only | The value of system.sysUpTime when the last trap was generated. If no traps have been generated since the last reset, this attribute has a value of 0. No trap is issued as a result of a change to this value. |
| an50LinkPmp | 1.3.6.1.4.1.10728.2.16.5 | |||
| INT an50MaxCid | 1.3.6.1.4.1.10728.2.16.5.1 | INTEGER | read-only | The object contains the maximum number of CID for this equipment |
| INT an50LinkCurrentAvailId | 1.3.6.1.4.1.10728.2.16.5.2 | INTEGER | read-only | The current available ID in the Links table that is queried by NMS before creating a new row in Link Table |
RFC description
Manages Redline AN-50 wireless point-to-multipoint access points with PMP (Point-to-Multipoint) features, including registration and power supply monitoring.
Start monitoring Redline Communications AN-50 fixed-wireless broadband access platform (radio/security/management configuration) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.