| OID symbolic | OID numeric | Type | Access | Description |
| netgear | 1.3.6.1.4.1.4526 | | | |
| ngNasManager | 1.3.6.1.4.1.4526.22 | | | |
| STR nasMgrSoftwareVersion | 1.3.6.1.4.1.4526.22.1 | DisplayString | read-only | Version information for the ReadyDATAOS
ngNasManager software. |
| diskTable | 1.3.6.1.4.1.4526.22.3 | | not-accessible | A table of physical disks attached to the storage device. |
| diskEntry | 1.3.6.1.4.1.4526.22.3.1 | | not-accessible | An entry in the physical disk table. |
| INT diskNumber | 1.3.6.1.4.1.4526.22.3.1.1 | INTEGER | read-only | Instance number of the disk entry. |
| STR diskID | 1.3.6.1.4.1.4526.22.3.1.2 | DisplayString | read-only | Disk ID. |
| STR diskSlotName | 1.3.6.1.4.1.4526.22.3.1.3 | DisplayString | read-only | The slot location of the disk. |
| STR diskSerial | 1.3.6.1.4.1.4526.22.3.1.4 | DisplayString | read-only | Disk Serial number. |
| STR diskModel | 1.3.6.1.4.1.4526.22.3.1.5 | DisplayString | read-only | The disk drive's model name. |
| INT ataError | 1.3.6.1.4.1.4526.22.3.1.6 | INTEGER | read-only | ATA error number for this disk from S.M.A.R.T read. |
| STR diskCapacity | 1.3.6.1.4.1.4526.22.3.1.7 | DisplayString | read-only | The capacity of the disk in bytes. |
| STR diskInterface | 1.3.6.1.4.1.4526.22.3.1.8 | DisplayString | read-only | The disk connect interface, such as SATA, USB etc. |
| STR diskState | 1.3.6.1.4.1.4526.22.3.1.9 | DisplayString | read-only | The current state of the Disk.
Possible states:
0: Online
1: Offline |
| INT diskTemperature | 1.3.6.1.4.1.4526.22.3.1.10 | INTEGER | read-only | temperature of this disk(in Fahrenheit unit). |
| fanTable | 1.3.6.1.4.1.4526.22.4 | | not-accessible | |
| fanEntry | 1.3.6.1.4.1.4526.22.4.1 | | not-accessible | |
| INT fanNumber | 1.3.6.1.4.1.4526.22.4.1.1 | INTEGER | read-only | Instance number of this fan entry. |
| INT fanRPM | 1.3.6.1.4.1.4526.22.4.1.2 | INTEGER | read-only | The current speed of the fan. |
| STR fanStatus | 1.3.6.1.4.1.4526.22.4.1.3 | DisplayString | read-only | The status of Fan |
| STR fanType | 1.3.6.1.4.1.4526.22.4.1.4 | DisplayString | read-only | What fan is used for:
SYS: for system board
CPU: for CPU
CASE: for system case |
| temperatureTable | 1.3.6.1.4.1.4526.22.5 | | not-accessible | |
| temperatureEntry | 1.3.6.1.4.1.4526.22.5.1 | | not-accessible | |
| INT temperatureNumber | 1.3.6.1.4.1.4526.22.5.1.1 | INTEGER | read-only | Instance number of this temperature probe entry. |
| INT temperatureValue | 1.3.6.1.4.1.4526.22.5.1.2 | INTEGER | read-only | The current temperature of this probe (in Fahrenheit unit). |
| STR temperatureTyoe | 1.3.6.1.4.1.4526.22.5.1.3 | DisplayString | read-only | The current temperature refer to |
| INT temperatureMin | 1.3.6.1.4.1.4526.22.5.1.4 | INTEGER | read-only | The min temperature of this probe (in Fahrenheit unit). |
| INT temperatureMax | 1.3.6.1.4.1.4526.22.5.1.5 | INTEGER | read-only | The max temperature of this probe (in Fahrenheit unit). |
| volumeTable | 1.3.6.1.4.1.4526.22.7 | | not-accessible | A table of active volumes on the storage device. |
| volumeEntry | 1.3.6.1.4.1.4526.22.7.1 | | not-accessible | An entry in the volume table. |
| STR volumeName | 1.3.6.1.4.1.4526.22.7.1.2 | DisplayString | read-only | The name of the volume. |
| STR volumeRAIDLevel | 1.3.6.1.4.1.4526.22.7.1.3 | DisplayString | read-only | The RAID level of the volume. |
| STR volumeStatus | 1.3.6.1.4.1.4526.22.7.1.4 | DisplayString | read-only | The severity of the volume.
Possible values:
1: ONLINE
2: OFFLINE
3: DEGRADED
4: FAULTED
5: REMOVED
6: UNAVAILABLE
7: UNKNOWN |
| INT volumeSize | 1.3.6.1.4.1.4526.22.7.1.5 | INTEGER | read-only | The size of the volume in megabytes. |
| INT volumeFreeSpace | 1.3.6.1.4.1.4526.22.7.1.6 | INTEGER | read-only | Free space on the volume in megabytes. |
| psuTable | 1.3.6.1.4.1.4526.22.8 | | not-accessible | |
| psuEntry | 1.3.6.1.4.1.4526.22.8.1 | | read-only | |
| INT psuNumber | 1.3.6.1.4.1.4526.22.8.1.1 | INTEGER | read-only | Instance number of this power supply unit. |
| STR psuDesc | 1.3.6.1.4.1.4526.22.8.1.2 | DisplayString | read-only | The description of this PSU. |
| STR psuStatus | 1.3.6.1.4.1.4526.22.8.1.3 | DisplayString | read-only | The current PSU status. |
| aryMgrEvts | 1.3.6.1.4.1.4526.22.200 | | | |
| STR controllerNameEv | 1.3.6.1.4.1.4526.22.200.201 | DisplayString | read-only | Controller Name for which trap is generated. |
| INT channelNumberEv | 1.3.6.1.4.1.4526.22.200.202 | INTEGER | read-only | Channel Number for which trap is generated. |
| INT targetIDEv | 1.3.6.1.4.1.4526.22.200.203 | INTEGER | read-only | SCSI ID of the device for which trap is generated. |
| STR virtualDiskNameEv | 1.3.6.1.4.1.4526.22.200.204 | DisplayString | read-only | Virtual Disk for which trap is generated. |
| STR arrayDiskNameEv | 1.3.6.1.4.1.4526.22.200.205 | DisplayString | read-only | Array Disk for which trap is generated. |
| STR oldVDConfigEv | 1.3.6.1.4.1.4526.22.200.206 | DisplayString | read-only | Current Virtual Disk configuration for which trap is generated |
| STR newVDConfigEv | 1.3.6.1.4.1.4526.22.200.207 | DisplayString | read-only | New Virtual Disk configuration for which trap is generated. |
| INT enclosureNumberEv | 1.3.6.1.4.1.4526.22.200.208 | INTEGER | read-only | Enclosure Number for which trap is generated. |
| INT unitNumberEv | 1.3.6.1.4.1.4526.22.200.209 | INTEGER | read-only | Unit Number for which trap is generated.
(Fan, Power Supply, Temperature Probe) |
| STR enclosureNameEv | 1.3.6.1.4.1.4526.22.200.210 | DisplayString | read-only | Enclosure Name for which trap is generated. |
| STR unitNameEv | 1.3.6.1.4.1.4526.22.200.211 | DisplayString | read-only | Unit Number for which trap is generated.
(Fan, Power Supply, Temperature Probe) |
| INT timeEv | 1.3.6.1.4.1.4526.22.200.212 | INTEGER | read-only | Amount of time specified in the trap message. |
| STR volumeNameEv | 1.3.6.1.4.1.4526.22.200.213 | DisplayString | read-only | Volume Drive Letter for which trap is generated. |
| nasTraps | 1.3.6.1.4.1.4526.22.300 | | | |
| NTF fanFailure | 1.3.6.1.4.1.4526.22.300.0.10 | | | Fan failure, fan speed is %s. |
| NTF tempFailure | 1.3.6.1.4.1.4526.22.300.0.20 | | | Temperature sensor reports out of normal range. |
| NTF powerVoltage | 1.3.6.1.4.1.4526.22.300.0.30 | | | System power is out of spec, please check system status! |
| NTF raidEventNotice | 1.3.6.1.4.1.4526.22.300.0.40 | | | RAID event detected! |
| NTF snapshotEventNotice | 1.3.6.1.4.1.4526.22.300.0.50 | | | Snapshot event detected! |
| NTF hotplugDiskNotice | 1.3.6.1.4.1.4526.22.300.0.60 | | | Hotplug disk event detected! |
| NTF upsEventNotice | 1.3.6.1.4.1.4526.22.300.0.70 | | | UPS status. |
| NTF volumeNotice | 1.3.6.1.4.1.4526.22.300.0.80 | | | Volume is approaching capacity. |
| NTF diskTempWarning | 1.3.6.1.4.1.4526.22.300.0.90 | | | Disk temperature warning. |
| NTF backupNotice | 1.3.6.1.4.1.4526.22.300.0.100 | | | Backup job status. |
| NTF diskSmartWarning | 1.3.6.1.4.1.4526.22.300.0.110 | | | Disk SMART warning. |
| NTF psuWarning | 1.3.6.1.4.1.4526.22.300.0.120 | | | Power supply unit warning. |
| STR fanFailureMesg | 1.3.6.1.4.1.4526.22.400 | DisplayString | read-only | Failure message for Fan |
| STR tempFailureMesg | 1.3.6.1.4.1.4526.22.401 | DisplayString | read-only | Failure message for system temperature |
| STR powerVoltageMesg | 1.3.6.1.4.1.4526.22.402 | DisplayString | read-only | Failure message for system power |
| STR raidEventNoticeMesg | 1.3.6.1.4.1.4526.22.403 | DisplayString | read-only | RAID hotplug event message |
| STR snapshotEventNoticeMesg | 1.3.6.1.4.1.4526.22.404 | DisplayString | read-only | Snapshot messages |
| STR upsEventNoticeMesg | 1.3.6.1.4.1.4526.22.405 | DisplayString | read-only | UPS status message |
| STR hotplugDiskNoticeMesg | 1.3.6.1.4.1.4526.22.406 | DisplayString | read-only | Disk hotplug event messages |
| STR volumeNoticeMesg | 1.3.6.1.4.1.4526.22.407 | DisplayString | read-only | Disk usage warning |
| STR diskTempWarningMesg | 1.3.6.1.4.1.4526.22.408 | DisplayString | read-only | Disk temperature warning messages |
| STR backupNoticeMesg | 1.3.6.1.4.1.4526.22.409 | DisplayString | read-only | Backup job status messages |
| STR diskSmartWarningMesg | 1.3.6.1.4.1.4526.22.410 | DisplayString | read-only | Disk SMART messages |
| STR psuWarningMesg | 1.3.6.1.4.1.4526.22.411 | DisplayString | read-only | PSU status messages |
| productID | 1.3.6.1.4.1.4526.100 | | | |
| ReadyDATAOS | 1.3.6.1.4.1.4526.100.15 | | | |