READYDATAOS-MIB :: temperatureMin

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › READYDATAOS-MIB › temperatureMin

temperatureMin

Module: READYDATAOS-MIB

OID (symbolic): READYDATAOS-MIB::temperatureMin

OID (numeric): 1.3.6.1.4.1.4526.22.5.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The min temperature of this probe (in Fahrenheit unit).

What is temperatureMin?

The minimum acceptable temperature, in Fahrenheit, for this probe's location. An admin uses this as the lower bound of the normal operating range when evaluating whether temperatureValue indicates a problem, such as a cooling malfunction causing unusually low ambient readings.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4526.22.5.1.4
snmpwalk -v2c -c public <target> READYDATAOS-MIB::temperatureMin

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4526.22.5.1.4.1
snmpget -v2c -c public <target> READYDATAOS-MIB::temperatureMin.1

Start monitoring Netgear ReadyDATA OS storage appliances (volume/disk health, system status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the READYDATAOS-MIB::temperatureMin OID value, configure state conditions and alerts, and monitor any Netgear ReadyDATA OS storage appliances (volume/disk health, system status) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4526netgearFSM726S-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4526.22ngNasManagerREADYDATAOS-MIB
1.3.6.1.4.1.4526.22.5temperatureTableREADYDATAOS-MIB
1.3.6.1.4.1.4526.22.5.1temperatureEntryREADYDATAOS-MIB
1.3.6.1.4.1.4526.22.5.1.4temperatureMinREADYDATAOS-MIB