RAPID-CITY :: rcSysBufferUtilPeak

MIB Reference — IPNetwork Monitor · Updated September 12, 2026

All MIBsRAPID-CITYrcSysBufferUtilPeak

rcSysBufferUtilPeak

Module: RAPID-CITY

OID (symbolic): RAPID-CITY::rcSysBufferUtilPeak

OID (numeric): 1.3.6.1.4.1.2272.1.1.14

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The largest buffer utilization since sysUpTime

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2272.1.1.14
snmpwalk -v2c -c public <target> RAPID-CITY::rcSysBufferUtilPeak

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2272.1.1.14.1
snmpget -v2c -c public <target> RAPID-CITY::rcSysBufferUtilPeak.1

Start monitoring Bay Networks/Nortel Accelar and Ethernet Routing Switch (ERS) chassis switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RAPID-CITY::rcSysBufferUtilPeak OID value, configure state conditions and alerts, and monitor any Bay Networks/Nortel Accelar and Ethernet Routing Switch (ERS) chassis switches from a single console.

How to Use in IPNetwork Monitor

Select a Bay Networks/Nortel Accelar or Ethernet Routing Switch (ERS) chassis switch as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type rcSysBufferUtilPeak into the Find box to locate it in the OID tree, then select it and click OK. It reports the largest buffer utilization observed since the system last booted, as a percentage. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the peak reaches 90% or higher, since a high historical peak indicates the system came close to exhausting its packet buffers at some point. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2272rapidCityRAPID-CITY
1.3.6.1.4.1.2272.1rcMgmtRAPID-CITY
1.3.6.1.4.1.2272.1.1rcSystemRAPID-CITY
1.3.6.1.4.1.2272.1.1.14rcSysBufferUtilPeakRAPID-CITY