| OID symbolic | OID numeric | Type | Access | Description |
| fujitsu | 1.3.6.1.4.1.211 | | | |
| products | 1.3.6.1.4.1.211.1 | | | |
| iaServer | 1.3.6.1.4.1.211.1.31 | | | |
| primequest | 1.3.6.1.4.1.211.1.31.1 | | | |
| partition | 1.3.6.1.4.1.211.1.31.1.2 | | | |
| parititonVariables | 1.3.6.1.4.1.211.1.31.1.2.200 | | | |
| trapVarComInfo | 1.3.6.1.4.1.211.1.31.1.2.200.1 | | | |
| STR trapPartitionName | 1.3.6.1.4.1.211.1.31.1.2.200.1.1 | DisplayString | not-accessible | Partition name which trap is generated. |
| INT trapPartitionId | 1.3.6.1.4.1.211.1.31.1.2.200.1.2 | INTEGER | not-accessible | Paritition identifier which trap is generated. |
| STR trapEventLevel | 1.3.6.1.4.1.211.1.31.1.2.200.1.3 | DisplayString | not-accessible | Event level |
| INT trapEventId | 1.3.6.1.4.1.211.1.31.1.2.200.1.4 | INTEGER | not-accessible | Event Identifier |
| STR trapUnitName | 1.3.6.1.4.1.211.1.31.1.2.200.1.5 | DisplayString | not-accessible | Unit name which trap is generated. |
| STR trapMmbVip | 1.3.6.1.4.1.211.1.31.1.2.200.1.6 | DisplayString | not-accessible | Management board vertual IP address. |
| trapVarDivInfo | 1.3.6.1.4.1.211.1.31.1.2.200.2 | | | |
| STR trapPartNo | 1.3.6.1.4.1.211.1.31.1.2.200.2.1 | DisplayString | not-accessible | Parts number of trap source. |
| STR trapStepping | 1.3.6.1.4.1.211.1.31.1.2.200.2.2 | DisplayString | not-accessible | |
| STR trapSerialNo | 1.3.6.1.4.1.211.1.31.1.2.200.2.3 | DisplayString | not-accessible | Serial number of trap source. |
| STR trapModelNo | 1.3.6.1.4.1.211.1.31.1.2.200.2.4 | DisplayString | not-accessible | Model number of trap source. |
| STR trapSuspect | 1.3.6.1.4.1.211.1.31.1.2.200.2.5 | DisplayString | not-accessible | Logical name or pci bus number of trap source. |
| STR trapVendorId | 1.3.6.1.4.1.211.1.31.1.2.200.2.6 | DisplayString | not-accessible | Vendor identifier of trap source. |
| STR trapDeviceId | 1.3.6.1.4.1.211.1.31.1.2.200.2.7 | DisplayString | not-accessible | Device identifier of trap source. |
| STR trapRevision | 1.3.6.1.4.1.211.1.31.1.2.200.2.8 | DisplayString | not-accessible | Revision of trap source. |
| STR trapCardName | 1.3.6.1.4.1.211.1.31.1.2.200.2.9 | DisplayString | not-accessible | Device name of trap source. |
| STR trapErrDetail | 1.3.6.1.4.1.211.1.31.1.2.200.2.10 | DisplayString | not-accessible | |
| STR trapErrCode | 1.3.6.1.4.1.211.1.31.1.2.200.2.11 | DisplayString | not-accessible | |
| STR trapIrpCode | 1.3.6.1.4.1.211.1.31.1.2.200.2.12 | DisplayString | not-accessible | |
| INT trapHbaNo | 1.3.6.1.4.1.211.1.31.1.2.200.2.13 | INTEGER | not-accessible | |
| STR trapErrCause | 1.3.6.1.4.1.211.1.31.1.2.200.2.14 | DisplayString | not-accessible | |
| INT trapPathNo | 1.3.6.1.4.1.211.1.31.1.2.200.2.15 | INTEGER | not-accessible | |
| STR trapDiskId | 1.3.6.1.4.1.211.1.31.1.2.200.2.16 | DisplayString | not-accessible | |
| STR trapFmrDiskId | 1.3.6.1.4.1.211.1.31.1.2.200.2.17 | DisplayString | not-accessible | |
| STR trapCurDiskId | 1.3.6.1.4.1.211.1.31.1.2.200.2.18 | DisplayString | not-accessible | |
| STR trapPathId | 1.3.6.1.4.1.211.1.31.1.2.200.2.19 | DisplayString | not-accessible | |
| STR trapPhysIf | 1.3.6.1.4.1.211.1.31.1.2.200.2.20 | DisplayString | not-accessible | |
| STR trapVirtualIf | 1.3.6.1.4.1.211.1.31.1.2.200.2.21 | DisplayString | not-accessible | |
| STR trapLogicalIp | 1.3.6.1.4.1.211.1.31.1.2.200.2.22 | DisplayString | not-accessible | |
| STR trapWatchIp | 1.3.6.1.4.1.211.1.31.1.2.200.2.23 | DisplayString | not-accessible | |
| STR trapInterface | 1.3.6.1.4.1.211.1.31.1.2.200.2.24 | DisplayString | not-accessible | |
| STR trapSourceIp | 1.3.6.1.4.1.211.1.31.1.2.200.2.25 | DisplayString | not-accessible | |
| STR trapDestIp | 1.3.6.1.4.1.211.1.31.1.2.200.2.26 | DisplayString | not-accessible | |
| STR trapModelName | 1.3.6.1.4.1.211.1.31.1.2.200.2.27 | DisplayString | not-accessible | Model name of trap source. |
| STR trapFlagcode | 1.3.6.1.4.1.211.1.31.1.2.200.2.28 | DisplayString | not-accessible | |
| partitionEnterprise | 1.3.6.1.4.1.211.1.31.1.2.201 | | | |
| psaComTrap | 1.3.6.1.4.1.211.1.31.1.2.201.1 | | | |
| psaLinLanComTrap | 1.3.6.1.4.1.211.1.31.1.2.201.2 | | | |
| psaLinIntelE100Trap | 1.3.6.1.4.1.211.1.31.1.2.201.3 | | | |
| psaLinIntelE1000Trap | 1.3.6.1.4.1.211.1.31.1.2.201.4 | | | |
| psaLinBcm5700Trap | 1.3.6.1.4.1.211.1.31.1.2.201.5 | | | |
| psaLinLsiLogicTrap | 1.3.6.1.4.1.211.1.31.1.2.201.7 | | | |
| psaLinScsiComTrap | 1.3.6.1.4.1.211.1.31.1.2.201.8 | | | |
| psaLinGrmpdTrap | 1.3.6.1.4.1.211.1.31.1.2.201.9 | | | |
| psaLinGdsTrap | 1.3.6.1.4.1.211.1.31.1.2.201.10 | | | |
| psaLinGlsTrap | 1.3.6.1.4.1.211.1.31.1.2.201.11 | | | |
| psaLinTg3Trap | 1.3.6.1.4.1.211.1.31.1.2.201.12 | | | |
| psaLinIbTrap | 1.3.6.1.4.1.211.1.31.1.2.201.13 | | | |
| psaLinXframe2Trap | 1.3.6.1.4.1.211.1.31.1.2.201.14 | | | |
| psaGschTrap | 1.3.6.1.4.1.211.1.31.1.2.201.15 | | | |
| psaLinIntelE1000ETrap | 1.3.6.1.4.1.211.1.31.1.2.201.16 | | | |
| psaLinIntelIgbTrap | 1.3.6.1.4.1.211.1.31.1.2.201.17 | | | |
| psaLinSvsRaidTrap | 1.3.6.1.4.1.211.1.31.1.2.201.18 | | | |
| psaLinIntelixgbeTrap | 1.3.6.1.4.1.211.1.31.1.2.201.19 | | | |
| NTF ixgbeEvent0 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11800 | | | ixgbe: Adapter or Software error (Cannot enable PCI device from suspend) |
| NTF ixgbeEvent1 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11801 | | | ixgbe: Adapter or Software error (Cannot initialize interrupts for device) |
| NTF ixgbeEvent2 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11802 | | | ixgbe: Adapter error (Fan has stopped) |
| NTF ixgbeEvent3 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11803 | | | ixgbe: Adapter or Software error (request_irq failed for MSIX interrupt Error) |
| NTF ixgbeEvent4 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11804 | | | ixgbe: Adapter or Software error (request_irq for msix_lsc failed) |
| NTF ixgbeEvent5 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11805 | | | ixgbe: Adapter or Software error (request_irq failed) |
| NTF ixgbeEvent6 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11806 | | | ixgbe: Adapter or Software error (RXDCTL.ENABLE on Rx queue not set within the polling period) |
| NTF ixgbeEvent7 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11807 | | | ixgbe: Adapter error (link_config FAILED) |
| NTF ixgbeEvent8 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11808 | | | ixgbe: Adapter error (Unable to allocate MSI-X interrupts) |
| NTF ixgbeEvent9 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11809 | | | ixgbe: Software error (Unable to allocate MSI interrupt; falling back to legacy) |
| NTF ixgbeEvent10 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11810 | | | ixgbe: Software error (Unable to allocate memory for queues) |
| NTF ixgbeEvent11 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11811 | | | ixgbe: Adapter or Software error (Unable to setup interrupt capabilities) |
| NTF ixgbeEvent12 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11812 | | | ixgbe: Software error (Unable to allocate memory for the transmit descriptor ring) |
| NTF ixgbeEvent13 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11813 | | | ixgbe: Software error (vmalloc allocation failed for the rx desc ring) |
| NTF ixgbeEvent14 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11814 | | | ixgbe: Adapter or Software error (Cannot re-enable PCI device after reset) |
| NTF ixgbeEvent15 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11815 | | | ixgbe: Adapter error (ixgbe_up failed after reset) |
| NTF ixgbeEvent16 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11816 | | | ixgbe: Adapter or Software error (HW Init failed) |
| NTF ixgbeEvent17 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11817 | | | ixgbe: Adapter error (Hardware Error) |
| NTF ixgbeEvent18 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11818 | | | ixgbe: Adapter or Software error (EEPROM initialization failed) |
| NTF ixgbeEvent19 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11819 | | | ixgbe: Software error (TX DMA map failed) |
| NTF ixgbeEvent20 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11820 | | | ixgbe: Software error (No usable DMA configuration) |
| NTF ixgbeEvent21 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11821 | | | ixgbe: Adapter error (The EEPROM Checksum Is Not Valid) |
| NTF ixgbeEvent22 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11822 | | | ixgbe: Adapter or Software error (invalid MAC address) |
| NTF ixgbeEvent23 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11823 | | | ixgbe: Adapter error (setup link failed) |
| NTF ixgbeEvent24 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11824 | | | ixgbe: Adapter error (pattern test failed) |
| NTF ixgbeEvent25 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11825 | | | ixgbe: Adapter error (set/check reg test failed) |
| NTF ixgbeEvent26 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11826 | | | ixgbe: Adapter error (failed STATUS register test) |
| NTF ixgbeEvent27 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11827 | | | ixgbe: Adapter error (Could not enable Tx Queue) |
| NTF ixgbeEvent28 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11828 | | | ixgbe: Software error (Failed to enable PCI sriov) |
| NTF ixgbeEvent29 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11829 | | | ixgbe: Software error (Unable to allocate memory for VF Data Storage - SRIOV disabled) |
| NTF ixgbeEvent30 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11830 | | | ixgbe: Adapter error (Error receiving msg from VF) |
| NTF ixgbeEvent31 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11831 | | | ixgbe: Software error (Could not set MAC Filter for VF) |
| NTF ixgbeEvent32 | 1.3.6.1.4.1.211.1.31.1.2.201.19.0.11832 | | | ixgbe: Software error (Unhandled Msg) |
| psaExternalFileUnitTrap | 1.3.6.1.4.1.211.1.31.1.2.201.101 | | | |