| OID symbolic | OID numeric | Type | Access | Description |
| vendor | 1.3.6.1.4.1.295 | | | |
| NTF switchTouched | 1.3.6.1.4.1.295.0.9 | | | This trap is generated when the IDENTIFY button on the switch is pressed. The agent throttles the generation of consecutive switchTouched traps so that there is at least a two second gap between them. |
| switch | 1.3.6.1.4.1.295.3 | | | |
| switchHardware | 1.3.6.1.4.1.295.3.1 | | | |
| switchChassis | 1.3.6.1.4.1.295.3.1.1 | | | |
| switchPort | 1.3.6.1.4.1.295.3.1.2 | | | |
| switchEthernetPort | 1.3.6.1.4.1.295.3.1.2.1 | | | |
| switchWaveBusPort | 1.3.6.1.4.1.295.3.1.2.2 | | | |
| switchFddiPort | 1.3.6.1.4.1.295.3.1.2.3 | | | |
| switchSoftware | 1.3.6.1.4.1.295.3.2 | | | |
| switchInfo | 1.3.6.1.4.1.295.3.2.1 | | | |
| switchBasicTable | 1.3.6.1.4.1.295.3.2.1.1 | | not-accessible | Basic information about the switch |
| switchBasicEntry | 1.3.6.1.4.1.295.3.2.1.1.1 | | not-accessible | Identification information about a particular port on the switch. |
| STR switchProductCode | 1.3.6.1.4.1.295.3.2.1.1.1.1 | DisplayString | read-only | An ASCII string giving the product code of the switch. |
| STR switchSerialNumber | 1.3.6.1.4.1.295.3.2.1.1.1.2 | DisplayString | read-only | An ASCII string giving the switch serial number. |
| INT switchPlaceOfManufacture | 1.3.6.1.4.1.295.3.2.1.1.1.3 | INTEGER | read-only | A number identifying where the switch was built. |
| STR switchDateOfManufacture | 1.3.6.1.4.1.295.3.2.1.1.1.4 | DisplayString | read-only | An ASCII string giving the date of manufacture of the switch. |
| MAC switchMacAddress | 1.3.6.1.4.1.295.3.2.1.1.1.5 | MacAddress | read-only | The IEEE 802 MAC address of the switch. |
| STR switchCodeVersion | 1.3.6.1.4.1.295.3.2.1.1.1.6 | DisplayString | read-only | An ASCII string giving the version number of the switch software. |
| INT switchBpeEnabled | 1.3.6.1.4.1.295.3.2.1.1.1.7 | INTEGER | read-write | Setting this variable to TRUE (1) causes the bridge protocol engine
to perform the Spanning Tree Protocol as defined in IEEE802.1d.
Setting this variable to FALSE (0) causes the BPE to stop performing
the Spanning Tree Protocol. The value of this variable when the
switch starts operating is 1. |
| INT eraseSwitchSnmpConfigInfo | 1.3.6.1.4.1.295.3.2.1.1.1.8 | INTEGER | read-write | Setting this variable to TRUE (1) causes the switch to erase its
SNMP configuration information both from memory and from permanent
store. The switch the requests new configuration information using
the BOOTP protocol. Setting this variable to any other value has
no effect. This variable will always return 0 when read. |
| INT restoreSwitchDot1dDefaults | 1.3.6.1.4.1.295.3.2.1.1.1.9 | INTEGER | read-write | Setting this variable to TRUE (1) causes the BPE to restore the
default spanning tree values given in the IEEE 802.1d specification.
This resets all writeable Bridge MIB variables in the dot1dStp group
of the Bridge MIB. Setting the variable to any other value has no
effect. This variable will always return 0 when read. |
| INT performSwitchReset | 1.3.6.1.4.1.295.3.2.1.1.1.10 | INTEGER | read-write | Setting this variable to TRUE (1) causes the switch to perform a
cold restart. As a result of this action a coldRestart trap will
be sent. Setting this variable to any other value has no effect.
This variable will always return 0 when read. |
| INT switchIdentPressed | 1.3.6.1.4.1.295.3.2.1.1.1.11 | INTEGER | read-only | This variable is TRUE (1) if the IDENTIFY button on the switch has
been pressed since the variable was last read.
After this variable has been read it will be set to 0. |
| INT ageFilterDatabase | 1.3.6.1.4.1.295.3.2.1.1.1.12 | INTEGER | read-write | Setting this variable to FALSE (0) causes the switch to stop aging
out entries from its filter database. Setting this variable to
TRUE (1) causes the switch to age out filter database entries as
defined in IEEE 802.1D. This variable is set to 0 whenever
the Switch restarts. |
| INT clearStatistics | 1.3.6.1.4.1.295.3.2.1.1.1.13 | INTEGER | read-write | Setting this variable to TRUE (1) clears the traffic statistics
accumulators in the switch. Setting this variable to any other
value has no effect. The variable always returns 0 when read. |
| INT switchBasicIndex | 1.3.6.1.4.1.295.3.2.1.1.1.100 | INTEGER | not-accessible | This is a dummy variable which provides a meta-index for the
Basic Information Table. |
| switchPortTable | 1.3.6.1.4.1.295.3.2.1.2 | | not-accessible | Identification information about the ports on a switch. |
| switchPortEntry | 1.3.6.1.4.1.295.3.2.1.2.1 | | not-accessible | Identification information about a particular port on the switch. |
| INT switchPortIndex | 1.3.6.1.4.1.295.3.2.1.2.1.1 | INTEGER | read-only | The number of the port to which the management information applies. |
| STR switchPortProductCode | 1.3.6.1.4.1.295.3.2.1.2.1.2 | DisplayString | read-only | An ASCII string giving the product code of the card on which this
port is located. |
| STR switchPortSerialNumber | 1.3.6.1.4.1.295.3.2.1.2.1.3 | DisplayString | read-only | An ASCII string giving the serial number of the card on which this
port is located. |
| INT switchPortPlaceOfManufacture | 1.3.6.1.4.1.295.3.2.1.2.1.4 | INTEGER | read-only | A number identifying where the card on which this port is located
was built. |
| STR switchPortDateOfManufacture | 1.3.6.1.4.1.295.3.2.1.2.1.5 | DisplayString | read-only | An ASCII string giving the date of manufacture of the card on which
this port is located. |
| STR switchPortState | 1.3.6.1.4.1.295.3.2.1.2.1.6 | DisplayString | read-only | An ASCII string giving the port's operational state. |
| INT switchPortHighSensitivity | 1.3.6.1.4.1.295.3.2.1.2.1.7 | INTEGER | read-write | This variable is only valid if the port is an Ethernet port.
If this variable is set to TRUE (1), the receiver of the Ethernet
NIC controlling the port is set to high sensitivity. If the
variable is set to 0, the port is set to normal sensitivity.
If the ports on both ends of the 10BaseT link are set to high
sensitivity, the maximum permissable length of the link is
increased from 100 meters to 120 meters.
Caution: a high sensitivity receiver may be overdriven by
transmitters closer than 100 meters.
This variable is 0 when the switch is powered up for the first
time. Changes to this variable are preserved across
system restarts. |
| INT restoreFddiMibDefaults | 1.3.6.1.4.1.295.3.2.1.2.1.8 | INTEGER | read-write | This variable is ony valid if the port is an FDDI station.
Setting this variable to TRUE (1) causes the agent to restore
the default MIB values given in the ANSI X3T9.5/84-49 Rev 7.2
specification. This resets all writable FDDI MIB variables.
Setting the variable to any other value has no effect.
This variable will always return 0 when read. |
| INT translateAllEthertypes | 1.3.6.1.4.1.295.3.2.1.2.1.9 | INTEGER | read-write | This variable is only valid if the port is an FDDI port.
If this variable is set to TRUE (1), the Bridge Tunnel Encapsulation
Protocol will be applied to frames containing any Ethertypes, not
just the ones in the Selective Translation Table.
If this variable is set to FALSE (0), the protocol will only be applied
to Ethertypes in the translation table. |
| CTR switchPortTxFrames | 1.3.6.1.4.1.295.3.2.1.2.1.10 | Counter | read-only | This counter is incremented by one for each frame transmitted
to the network segment attached to the port. |
| CTR switchPortRxFrames | 1.3.6.1.4.1.295.3.2.1.2.1.11 | Counter | read-only | This counter is incremented by one for each valid frame received
from the network segment attached to the port. |
| CTR switchPortFcsErrors | 1.3.6.1.4.1.295.3.2.1.2.1.12 | Counter | read-only | This counter is incremented by one for each received frame which failed
its FCS check. |
| CTR switchPortFilterDiscards | 1.3.6.1.4.1.295.3.2.1.2.1.13 | Counter | read-only | The number of frames received on this port which have been discarded
due to the filtering action of the port's bridge circuit. |
| CTR switchPortDelayExceededDiscards | 1.3.6.1.4.1.295.3.2.1.2.1.14 | Counter | read-only | The number of frames discarded by this port due to excessive transit
delay through the switch. It reports the same value as the object
dot1dBasePortDelayExceededDiscards in the Bridge MIB (RFC 1493). |
| CTR switchPortMtuExceededDiscards | 1.3.6.1.4.1.295.3.2.1.2.1.15 | Counter | read-only | The number of frames discarded by this port due to excessive size.
It is the same value reported in the object
dot1dBasePortMtuExceededDiscards in the Bridge MIB (RFC 1493). |
| switchSelectiveTranslationTable | 1.3.6.1.4.1.295.3.2.1.3 | | not-accessible | The Selective Translation Table as defined in IEEE 802.1h. |
| translationTableEntry | 1.3.6.1.4.1.295.3.2.1.3.1 | | not-accessible | One entry in the STT. |
| INT translationTablePortIndex | 1.3.6.1.4.1.295.3.2.1.3.1.1 | INTEGER | read-only | The table index - the port number on which the STT resides. |
| INT translationTableEthertype1 | 1.3.6.1.4.1.295.3.2.1.3.1.2 | INTEGER | read-write | The first Ethertype for which the Bridge Tunnel Encapsulation Protocol
should be used. |
| INT translationTableEntryValid1 | 1.3.6.1.4.1.295.3.2.1.3.1.3 | INTEGER | read-write | If this variable is set to TRUE (1), the Bridge Tunnel Encapsulation
Protocol will be applied to frames containing the first Ethertype.
If this variable is set to FALSE (0), the protocol will not be applied
to the Ethertype. |
| INT translationTableEthertype2 | 1.3.6.1.4.1.295.3.2.1.3.1.4 | INTEGER | read-write | The second Ethertype for which the Bridge Tunnel Encapsulation Protocol
should be used. |
| INT translationTableEntryValid2 | 1.3.6.1.4.1.295.3.2.1.3.1.5 | INTEGER | read-write | If this variable is set to TRUE (1), the Bridge Tunnel Encapsulation
Protocol will be applied to frames containing the second Ethertype.
If this variable is set to FALSE (0), the protocol will not be applied
to the Ethertype. |
| INT translationTableEthertype3 | 1.3.6.1.4.1.295.3.2.1.3.1.6 | INTEGER | read-write | The third Ethertype for which the Bridge Tunnel Encapsulation Protocol
should be used. |
| INT translationTableEntryValid3 | 1.3.6.1.4.1.295.3.2.1.3.1.7 | INTEGER | read-write | If this variable is set to TRUE (1), the Bridge Tunnel Encapsulation
Protocol will be applied to frames containing the third Ethertype.
If this variable is set to FALSE (0), the protocol will not be applied
to the Ethertype. |