| OID symbolic | OID numeric | Type | Access | Description |
| pdnSpectrumMgmt | 1.3.6.1.4.1.1795.2.24.2.6.19 | | | R.A.Bowhall
The Paradyne enterprise SPECTRUM MIB.
This MIB is written to facilitate spectrum
management of any xDSL interfaces. This mib
replaces older versions of the spectrum
management including the reachDSL.mib. |
| pdnSpecMgmtObjects | 1.3.6.1.4.1.1795.2.24.2.6.19.1 | | | |
| INT spectrumMgmtCountryCode | 1.3.6.1.4.1.1795.2.24.2.6.19.1.2 | INTEGER | read-write | This object selects which Spectrum Management
standard will be used on this device to calculate the
'allowed speeds' to comply with Spectrum Management.
Note:Spectrum Management must be Enabled for 'Country
Code' to take effect.
'USA' is the only valid selection for Region Setting
'Annex A', 'UK' will not be selectable.
'UK' for is the only valid selecton for Region Setting
'Annex B', 'USA' will not be selectable. |
| spectrumMgmtTable | 1.3.6.1.4.1.1795.2.24.2.6.19.1.3 | | not-accessible | The Spectrum Management Table. |
| spectrumMgmtEntry | 1.3.6.1.4.1.1795.2.24.2.6.19.1.3.1 | | not-accessible | An entry in the Spectrum Management table. |
| I32 spectrumMgmtEWL | 1.3.6.1.4.1.1795.2.24.2.6.19.1.3.1.1 | Integer32 | read-write | The Estimated Working Length [EWL(ft)]. The value
selected is the estimated length of the line in ft.
See the Deployment guideline Table below.
This value is usually specified by the carrier. This
value is only required if spectrumMgmt is Enabled and
the spectrumMgmtCountryCode selected is 'USA'. |
| I32 spectrumMgmtAllowedSpeedsMin1 | 1.3.6.1.4.1.1795.2.24.2.6.19.1.3.1.2 | Integer32 | read-only | This rate will be the Minimum Line Bit Rate based
on the Line Length selected.
See the Deployment guideline Table above.
Example: EWL=12.5 this value may be 808kbps |
| I32 spectrumMgmtAllowedSpeedsMax1 | 1.3.6.1.4.1.1795.2.24.2.6.19.1.3.1.3 | Integer32 | read-only | This rate will be the Maximum Line Bit Rate based
on the Line Length selected
See the Deployment guideline Table above.
Example: EWL=12.5 this value may be 832kbps |
| I32 spectrumMgmtAllowedSpeedsMin2 | 1.3.6.1.4.1.1795.2.24.2.6.19.1.3.1.4 | Integer32 | read-only | This rate will be the Minimum Line Bit Rate based
on the Line Length selected.
See the Deployment guideline Table above.
Example: EWL=12.5 this value may be 960kbps |
| I32 spectrumMgmtAllowedSpeedsMax2 | 1.3.6.1.4.1.1795.2.24.2.6.19.1.3.1.5 | Integer32 | read-only | This rate will be the Maximum Line Bit Rate based
on the Line Length selected.
See the Deployment guideline Table above.
Example: EWL=12.5 this value may be 1000kbps |
| INT spectrumMgmtLineLength | 1.3.6.1.4.1.1795.2.24.2.6.19.1.3.1.6 | INTEGER | read-write | This 'Line Length' feature is only required if the
SpectrumMgmt is Enabled and the spectrumMgmtCountryCode
selected is 'UK'.
'Short' Line Length from the exchange can support speeds
up to 2056 Kbps.
'Medium' Line Length can support speeds up to 1496 Kbps.
'Long' Line Length can suppport speeds up to 872 Kbps. |
| pdnNewSpecMgmtObjects | 1.3.6.1.4.1.1795.2.24.2.6.19.2 | | | |
| newSpectrumMgmtGeneralConfigTable | 1.3.6.1.4.1.1795.2.24.2.6.19.2.1 | | not-accessible | General Configuration of the spectrum management.
This table contains an entry for each technology
managed by this device. |
| newSpectrumMgmtGeneralConfigEntry | 1.3.6.1.4.1.1795.2.24.2.6.19.2.1.1 | | not-accessible | An entry with the general spectrum mgmt configuration
parameters for a specific DSL technology. |
| INT newSpectrumMgmtSelection | 1.3.6.1.4.1.1795.2.24.2.6.19.2.1.1.1 | INTEGER | read-write | This object is used to Enable or Disable
Spectrum Management on DSL interfaces
managed by this device. Enabling this object
limits the DSL speeds on each port based on
line length in order to meet ANSI T1.417
Spectrum Management requirements or BT Access
Network Spectrum requirements.
The values that this object can accept are
controlled by the -Mode- object. |
| INT newSpectrumMgmtMode | 1.3.6.1.4.1.1795.2.24.2.6.19.2.1.1.2 | INTEGER | read-only | This object restricts the MAX-ACCESS of the 'Selection'
object.
Following are the details of each of the values:
enableOnly(1) - Indicates that the 'Selection' object
IS always 'enabled' and cannot be set
to 'disabled'.
disableOnly(2) - Indicates that the 'Selection' object
IS always 'disabled' and cannot be set
to 'enabled'.
both(3) - Indicates that the 'Selection' object
will accept both the 'enabled' and
'disabled' values. |
| INT newSpectrumMgmtLoopMeasurementMethod | 1.3.6.1.4.1.1795.2.24.2.6.19.2.1.1.3 | INTEGER | read-only | This object indicates the measurement method used in
describing the Loop Length of a circuit. Following are the
details of each of the options:
none(1) - Indicates that the Spectral Compliance
is NOT dependant on any Loop Length
measurements or configurations.
loopLength(2) - The 'ConfLoopLength' object is used to
determine spectral compliance. The
'ConfEWL' & 'ConfQuadMode' objects are
not used in this mode.
ewl(3) - The 'ConfEWL' object is used to
configure the estimated loop length,
which is used to determine spectral
compliance. In this mode the
'ConfLoopLength' & 'ConfQuadMode'
objects are not used.
quadMode(4) - The 'ConfQuadMode' object is used to
determine spectral compliance. The
'ConfEWL' & 'ConfLoopLength' objects
are not used in this mode.
This object determines which of the three objects :
'ConfEWL', 'ConfLoopLength' or 'ConfQuadMode' is used
(if any) to enforce spectrally compliant maximum
'Tx Rates' and the maximum allowed 'Tx Power' on a given
circuit. |
| INT newSpectrumMgmtEWLUnits | 1.3.6.1.4.1.1795.2.24.2.6.19.2.1.1.4 | INTEGER | read-only | This object indicates the units of measurement used in
describing the Estimated Working Length of a circuit.
Following are the details of each of the units:
none(1) - Indicates that the Spectral Compliance is
NOT dependant on the 'ConfEWL' object.
feet(2) - The 'ConfEWL' is measured and configured
in feet.
meters(3) - The 'ConfEWL' is measured and configured
in meters. |
| newSpectrumMgmtConfTable | 1.3.6.1.4.1.1795.2.24.2.6.19.2.2 | | not-accessible | The new Spectrum Management Configuration Table
This table is used for configuring spectrum management
objects on any DSL interface. |
| newSpectrumMgmtConfEntry | 1.3.6.1.4.1.1795.2.24.2.6.19.2.2.1 | | not-accessible | An entry in the xDSL Spectrum Management
Configuration table.
Note: This entry can be accessed only for ifIndex
values that belong to a physical interface.
e.g. for ifType = 'shdsl' (IANAifType=169). |
| U32 newSpectrumMgmtConfEWL | 1.3.6.1.4.1.1795.2.24.2.6.19.2.2.1.1 | Unsigned32 | read-write | The Equivalent Working Length (EWL). The value selected
corresponds to the estimated length of the line in
feet - if 'EWLUnits' object is 'feet'.
meters - if 'EWLUnits' object is 'meters'.
This value is usually specified by the carrier and MUST
be in integral multiples of
500 feet, if 'EWLUnits' is 'feet'.
200 meters, if 'EWLUnits' is 'meters'.
The range of values that this object can take is determined
by the 'MinEWL' and 'MaxEWL' objects.
Changing this object may limit the maximum transmit power
and the effective DSL speeds at which the ports train up.
Note: This object will be used only if Spectrum Management
is enabled and 'LoopMeasurementMethod' is 'ewl'.
This object shares a mutual exclusion relationship
with the 'ConfLoopLength' & 'ConfQuadMode' objects,
as only one of the two will be used for configuration
at any time. |
| INT newSpectrumMgmtConfLoopLength | 1.3.6.1.4.1.1795.2.24.2.6.19.2.2.1.2 | INTEGER | read-write | This entry specifies the loop length for the line. The
configurable values are short(1), medium(2) and long(3).
The 'Loop Length' feature can be used only if the
'shdslSpectrumMgmtSelection' object is Enabled and
the 'LoopMeasurementMethod' is 'loopLength'. Changing this
object may limit the maximum transmit power and the
effective DSL speeds at which ports train up.
Note: This object shares a mutual exclusion relationship
with the 'ConfEWL' objects. i.e. only one of the
three can be used for configuration at one time. |
| INT newSpectrumMgmtConfQuadMode | 1.3.6.1.4.1.1795.2.24.2.6.19.2.2.1.3 | INTEGER | read-write | This entry specifies the quad cable configuration &
length for the line. The configurable values are
sameQuad(1), segregatedQuadUpto3km(2) and
segregatedQuadAbove3km(3). The 'Quad Mode' feature can be
used only if the 'reachDSLSpectrumMgmtSelection' object
is Enabled and the 'LoopMeasurementMethod' is 'quadMode'.
Changing this object may limit the maximum transmit power
and the effective DSL speeds at which ports train up.
Note: This object shares a mutual exclusion relationship
with the 'ConfEWL' & 'ConfLoopLength' objects.
i.e. only one of the three can be used for
configuration at one time. |
| newSpectrumMgmtLineInfoTable | 1.3.6.1.4.1.1795.2.24.2.6.19.2.3 | | not-accessible | The Spectrum Management Line Info Table.
This table gives information about the spectrum
management ranges that are applicable for each port,
based on the spectral requirements for the device. |
| newSpectrumMgmtLineInfoEntry | 1.3.6.1.4.1.1795.2.24.2.6.19.2.3.1 | | not-accessible | An entry in the newSpectrumMgmtLineInfoTable table.
Note: This entry can be accessed only for ifIndex values
that belong to a physical interface.
e.g. for ifType = 'adsl'. |
| U32 newSpectrumMgmtXtucMax1TxRate | 1.3.6.1.4.1.1795.2.24.2.6.19.2.3.1.1 | Unsigned32 | read-only | This rate will be the max allowed Tx Rate(in bps) for
the port based on the Spectrum Management requirements for
XTUC in a particular spectral compliance configuration.
Some measurement methods may have more than one range for
the TxRate. Min1TxRate and Max1TxRate will always have
the first range of values and the Min2TxRate and Max2TxRate
will have the second range if the method demands it. |
| U32 newSpectrumMgmtXtucMin1TxRate | 1.3.6.1.4.1.1795.2.24.2.6.19.2.3.1.2 | Unsigned32 | read-only | This rate will be the min allowed Tx Rate based on the
spectrum management requirements for the XTUC. The
MinTxRate will be upper bounded by
'newSpectrumMgmtXtucMax1TxRate' object.
Some measurement methods may have more than one range for
the TxRate. Min1TxRate and Max1TxRate will always have
the first range of values and the Min2TxRate and Max2TxRate
will have the second range if the method demands it. |
| U32 newSpectrumMgmtXtucMax2TxRate | 1.3.6.1.4.1.1795.2.24.2.6.19.2.3.1.3 | Unsigned32 | read-only | This rate will be the max allowed Tx Rate(in bps) for
the port based on the Spectrum Management requirements for
XTUC in a particular spectral compliance configuration.
This object is the
Some measurement methods may have more than one range for
the TxRate. Min1TxRate and Max1TxRate will always have
the first range of values and the Min2TxRate and Max2TxRate
will have the second range if the method demands it. |
| U32 newSpectrumMgmtXtucMin2TxRate | 1.3.6.1.4.1.1795.2.24.2.6.19.2.3.1.4 | Unsigned32 | read-only | This rate will be the min allowed Tx Rate based on the
spectrum management requirements for the XTUC. The
MinTxRate will be upper bounded by
'newSpectrumMgmtXtucMax1TxRate' object.
Some measurement methods may have more than one range for
the TxRate. Min1TxRate and Max1TxRate will always have
the first range of values and the Min2TxRate and Max2TxRate
will have the second range if the method demands it. |
| INT newSpectrumMgmtXtucMaxTxPower | 1.3.6.1.4.1.1795.2.24.2.6.19.2.3.1.5 | INTEGER | read-only | The maximum transmit power at the ATUC (in tenth dB).
This value will be based on the spectrum management
selection. |
| U32 newSpectrumMgmtXturMax1TxRate | 1.3.6.1.4.1.1795.2.24.2.6.19.2.3.1.6 | Unsigned32 | read-only | This rate will be the max allowed Tx Rate(in bps) for
the port based on the Spectrum Management requirements for
XTUR in a particular spectral compliance configuration.
This object is the
Some measurement methods may have more than one range for
the TxRate. Min1TxRate and Max1TxRate will always have
the first range of values and the Min2TxRate and Max2TxRate
will have the second range if the method demands it. |
| U32 newSpectrumMgmtXturMin1TxRate | 1.3.6.1.4.1.1795.2.24.2.6.19.2.3.1.7 | Unsigned32 | read-only | This rate will be the min allowed Tx Rate based on the
spectrum management requirements for the XTUR. The
MinTxRate will be upper bounded by
'newSpectrumMgmtXturMax1TxRate' object.
Some measurement methods may have more than one range for
the TxRate. Min1TxRate and Max1TxRate will always have
the first range of values and the Min2TxRate and Max2TxRate
will have the second range if the method demands it. |
| U32 newSpectrumMgmtXturMax2TxRate | 1.3.6.1.4.1.1795.2.24.2.6.19.2.3.1.8 | Unsigned32 | read-only | This rate will be the max allowed Tx Rate(in bps) for
the port based on the Spectrum Management requirements for
XTUR in a particular spectral compliance configuration.
Some measurement methods may have more than one range for
the TxRate. Min1TxRate and Max1TxRate will always have
the first range of values and the Min2TxRate and Max2TxRate
will have the second range if the method demands it. |
| U32 newSpectrumMgmtXturMin2TxRate | 1.3.6.1.4.1.1795.2.24.2.6.19.2.3.1.9 | Unsigned32 | read-only | This rate will be the min allowed Tx Rate based on the
spectrum management requirements for the XTUR. The
MinTxRate will be upper bounded by
'newSpectrumMgmtXtucMax1TxRate' object.
Some measurement methods may have more than one range for
the TxRate. Min1TxRate and Max1TxRate will always have
the first range of values and the Min2TxRate and Max2TxRate
will have the second range if the method demands it. |
| INT newSpectrumMgmtXturMaxTxPower | 1.3.6.1.4.1.1795.2.24.2.6.19.2.3.1.10 | INTEGER | read-only | The maximum transmit power at the ATUR (in tenth dB). This
value will be based on the spectrum management selection. |
| U32 newSpectrumMgmtMinEWL | 1.3.6.1.4.1.1795.2.24.2.6.19.2.3.1.11 | Unsigned32 | read-only | The minimum value (in feet, if 'EWLUnits' is 'feet, or in
meters, if 'EWLUnits' is 'meters') that the 'ConfEWL'
object can accept. Together with the 'MaxEWL' object,
this object indicates the range of EWL when 'EWLUnits' is
either 'feet' or 'meters'.
Note : This object is valid only if the
'LoopMeasurementMethod' object is 'ewl'. |
| U32 newSpectrumMgmtMaxEWL | 1.3.6.1.4.1.1795.2.24.2.6.19.2.3.1.12 | Unsigned32 | read-only | The maximum value (in feet, if 'EWLUnits' is 'feet, or in
meters, if 'EWLUnits' is 'meters') that the 'ConfEWL'
object can accept. Together with the 'MinEWL' object,
this object indicates the range of EWL when 'EWLUnits' is
either 'feet' or 'meters'.
Note : This object is valid only if the
'LoopMeasurementMethod' object is 'ewl'. |
| pdnSpecMgmtConformance | 1.3.6.1.4.1.1795.2.24.2.6.19.3 | | | |
| pdnSpecMgmtGroups | 1.3.6.1.4.1.1795.2.24.2.6.19.3.1 | | | |
| pdnGeneralConfigGroup | 1.3.6.1.4.1.1795.2.24.2.6.19.3.1.1 | | | A collection of general configuration objects
required for the spectrum management of
interfaces. |
| pdnLineInfoGroup | 1.3.6.1.4.1.1795.2.24.2.6.19.3.1.2 | | | A collection of objects providing information
regarding spectrum management of interfaces. |
| pdnEWLModeGroup | 1.3.6.1.4.1.1795.2.24.2.6.19.3.1.3 | | | A collection of configuration objects used to
control spectrum management of DSL intfs when
the measurement method is 'EWL'. |
| pdnLoopLengthModeGroup | 1.3.6.1.4.1.1795.2.24.2.6.19.3.1.4 | | | A collection of configuration objects used to
control spectrum management of DSL intfs when
the measurement method is 'LoopLength' |
| pdnQuadModeGroup | 1.3.6.1.4.1.1795.2.24.2.6.19.3.1.5 | | | A collection of object(s) providing configuration
access and information specific to DSL interfaces
whose loop/line length measurement method is based on the
Quad configuration.
i.e.the newSpectrumMgmtLoopMeasurementMethod object
is 'quadMode'. |
| pdnSpectrumMgmtDeprecatedGroup | 1.3.6.1.4.1.1795.2.24.2.6.19.3.1.7 | | | Deprecated objects |
| pdnSpecMgmtCompliances | 1.3.6.1.4.1.1795.2.24.2.6.19.3.2 | | | |
| pdnSpecMgmtCompliance | 1.3.6.1.4.1.1795.2.24.2.6.19.3.2.1 | | | The compliance statement for SNMP entities that control
spectrum management on interfaces. |