All MIBs › OPL-SP-MIB
Organization: Sun Microsystems, Inc. Fujitsu LIMITED
Last Updated: 2010-05-24
Category: Server Hardware
Description: Provides SNMP management objects for monitoring Sun/Fujitsu SPARC Enterprise server platform hardware status.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OPL-SP-MIB?
OPL-SP-MIB is a joint Sun Microsystems/Fujitsu MIB for the service processor of Sun/Fujitsu's SPARC Enterprise OPL (M-series) high-end UNIX servers, providing SNMP access to the platform's service-processor management data. It exposes service-processor-level configuration and status data, including an agent identification/table, XCP (cross-platform service processor) firmware version, and the service processor's own IP address configuration. It is used to monitor the hardware/software status of the server's service processor itself, confirming the running XCP firmware version, service processor identity, and network reachability (IP address), which is the foundation for remote out-of-band hardware management, console access, and fault reporting on the OPL platform. As a joint Sun/Fujitsu private MIB it has no notable dependency on external standard MIBs, though it works alongside the platform's broader hardware-management infrastructure. It's typically deployed on Sun/Fujitsu SPARC Enterprise M-series servers in enterprise data centers where administrators manage the server out-of-band via its dedicated service processor. Network engineers evaluating or troubleshooting this functionality can download the OPL-SP-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OPL-SP-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Sun/Fujitsu SPARC Enterprise (M-series) server
Monitoring Examples
An administrator polls scfAgentTable/scfAgentEntry (via scfAgentIndex) to identify the active service-processor agent and reads scfXcpVersion to confirm the running XCP firmware build. scfIpAddressTable/scfIpAddressEntry (with scfIpAddressIndex, scfIpAddress, and scfIpAddressPortNumber) exposes the service processor's own management IP address and port, letting an operator verify out-of-band network reachability. A service processor reporting an unexpected or outdated scfXcpVersion, or an scfIpAddress that doesn't match the expected management network, would indicate a firmware or network misconfiguration on the service processor itself.
What Can Be Monitored
- service processor agent identity
- XCP firmware version
- service processor IP address/port configuration
- service processor state
This MIB depends on
Imported Objects
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| enterprises |
From SNMPv2-TC
| DisplayString | |
| TEXTUAL-CONVENTION |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| fujitsu | 1.3.6.1.4.1.211 | |||
| product | 1.3.6.1.4.1.211.1 | |||
| solaris | 1.3.6.1.4.1.211.1.15 | |||
| sparcEnterprise | 1.3.6.1.4.1.211.1.15.3 | |||
| oplSpMIB | 1.3.6.1.4.1.211.1.15.3.1 | Version: 1.5 Copyright 2009, by Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. All Rights Reserved, Copyright Fujitsu LIMITED 2007-2009. This MIB module provides monitoring capabilities for OPL Systems. | ||
| scfObjects | 1.3.6.1.4.1.211.1.15.3.1.1 | |||
| scfInfo | 1.3.6.1.4.1.211.1.15.3.1.1.1 | |||
| I32 scfAgentId | 1.3.6.1.4.1.211.1.15.3.1.1.1.1 | Integer32 | read-only | SCF board ID which this SNMP agent is currently running on. |
| I32 scfAgentNumber | 1.3.6.1.4.1.211.1.15.3.1.1.1.2 | Integer32 | read-only | Total count of available SCF boards. |
| scfAgentTable | 1.3.6.1.4.1.211.1.15.3.1.1.1.3 | not-accessible | Table of available SCF boards. | |
| scfAgentEntry | 1.3.6.1.4.1.211.1.15.3.1.1.1.3.1 | not-accessible | Available SCF board entry. | |
| SCF scfAgentIndex | 1.3.6.1.4.1.211.1.15.3.1.1.1.3.1.1 | ScfIndex | read-only | SCF board ID. |
| STR scfXcpVersion | 1.3.6.1.4.1.211.1.15.3.1.1.1.3.1.2 | DisplayString | read-only | SCF board XSCF Control Package(XCP) version. |
| I32 scfIpAddressPortNumber | 1.3.6.1.4.1.211.1.15.3.1.1.1.4 | Integer32 | read-only | SNMP communication port for all SCF LAN IP Addresses. |
| I32 scfIpAddressNumber | 1.3.6.1.4.1.211.1.15.3.1.1.1.5 | Integer32 | read-only | Total count of IP Address table entries. |
| scfIpAddressTable | 1.3.6.1.4.1.211.1.15.3.1.1.1.6 | not-accessible | Table of available management LAN IPs on SCF. | |
| scfIpAddressEntry | 1.3.6.1.4.1.211.1.15.3.1.1.1.6.1 | not-accessible | SCF LAN IP Address entry. | |
| SCF scfIpAddressIndex | 1.3.6.1.4.1.211.1.15.3.1.1.1.6.1.1 | ScfIndex | read-only | SCF IP Address table entry index. |
| IP scfIpAddress | 1.3.6.1.4.1.211.1.15.3.1.1.1.6.1.2 | IpAddress | read-only | IP Address of a management LAN port. |
| scfState | 1.3.6.1.4.1.211.1.15.3.1.1.2 | |||
| SCF scfSystemState | 1.3.6.1.4.1.211.1.15.3.1.1.2.1 | ScfErrorStatus | read-only | Overall system state. |
| SCF scfFirmwareState | 1.3.6.1.4.1.211.1.15.3.1.1.2.2 | ScfErrorStatus | read-only | SCF software state. |
| SCF scfHardwareState | 1.3.6.1.4.1.211.1.15.3.1.1.2.3 | ScfErrorStatus | read-only | Overall system hardware state. |
| SCF scfModeSwitch | 1.3.6.1.4.1.211.1.15.3.1.1.2.4 | ScfModeSwitchState | read-only | Operator panel switch state. |
| scfMonitorInfo | 1.3.6.1.4.1.211.1.15.3.1.1.3 | |||
| I32 scfMonitorNumber | 1.3.6.1.4.1.211.1.15.3.1.1.3.1 | Integer32 | read-only | Total count of environmental monitor table entries. |
| scfMonitorTable | 1.3.6.1.4.1.211.1.15.3.1.1.3.2 | not-accessible | Monitor table. Contains environmental monitor information for system components. | |
| scfMonitorEntry | 1.3.6.1.4.1.211.1.15.3.1.1.3.2.1 | not-accessible | Environmental monitor table entry. | |
| SCF scfMonitorBoardType | 1.3.6.1.4.1.211.1.15.3.1.1.3.2.1.1 | ScfComponentType | read-only | Monitor component board type. |
| SCF scfMonitorBoardId | 1.3.6.1.4.1.211.1.15.3.1.1.3.2.1.2 | ScfIndex | read-only | Monitor component board ID. |
| SCF scfMonitorModuleType | 1.3.6.1.4.1.211.1.15.3.1.1.3.2.1.3 | ScfComponentType | read-only | Monitor component module type. |
| SCF scfMonitorModuleId | 1.3.6.1.4.1.211.1.15.3.1.1.3.2.1.4 | ScfIndex | read-only | Monitor component module ID. |
| SCF scfMonitorType | 1.3.6.1.4.1.211.1.15.3.1.1.3.2.1.5 | ScfMonitorTypeTC | read-only | Monitor component type. |
| SCF scfMonitorId | 1.3.6.1.4.1.211.1.15.3.1.1.3.2.1.6 | ScfIndex | read-only | Monitor ID. |
| STR scfMonitorDescription | 1.3.6.1.4.1.211.1.15.3.1.1.3.2.1.7 | DisplayString | read-only | Text description of a monitor component. |
| STR scfMonitorAdditionalInfo | 1.3.6.1.4.1.211.1.15.3.1.1.3.2.1.8 | DisplayString | read-only | Additional monitor info. |
| STR scfMonitorUnits | 1.3.6.1.4.1.211.1.15.3.1.1.3.2.1.9 | DisplayString | read-only | Units of value. |
| SCF scfMonitorStatus | 1.3.6.1.4.1.211.1.15.3.1.1.3.2.1.10 | ScfValidStatus | read-only | Status of monitor component. Reflects if the sensor could be accessed or should not be used based on the containing components state. |
| I32 scfMonitorValue | 1.3.6.1.4.1.211.1.15.3.1.1.3.2.1.11 | Integer32 | read-only | Monitor value. |
| SCF scfMonitorValueStatus | 1.3.6.1.4.1.211.1.15.3.1.1.3.2.1.12 | ScfErrorStatus | read-only | Status of the monitor value. Reflects if valid value is within required limits. |
| scfSystemInfo | 1.3.6.1.4.1.211.1.15.3.1.1.4 | |||
| STR scfSystemName | 1.3.6.1.4.1.211.1.15.3.1.1.4.1 | DisplayString | read-only | System name. |
| STR scfSystemType | 1.3.6.1.4.1.211.1.15.3.1.1.4.2 | DisplayString | read-only | System type. |
| STR scfSystemSerialNumber | 1.3.6.1.4.1.211.1.15.3.1.1.4.3 | DisplayString | read-only | System serial number. |
| STR scfSystemAdditionalInfo | 1.3.6.1.4.1.211.1.15.3.1.1.4.4 | DisplayString | read-only | Additional System information. |
| I32 scfSystemCpuNumber | 1.3.6.1.4.1.211.1.15.3.1.1.4.5 | Integer32 | read-only | Total count of CPUs/Chips in this system. |
| I32 scfSystemMemoryCapacity | 1.3.6.1.4.1.211.1.15.3.1.1.4.6 | Integer32 | read-only | Total memory capacity of this system. |
| SCF scfSystemReadyLED | 1.3.6.1.4.1.211.1.15.3.1.1.4.7 | ScfLEDState | read-only | Systems Ready LED state. |
| SCF scfSystemPowerLED | 1.3.6.1.4.1.211.1.15.3.1.1.4.8 | ScfLEDState | read-only | Systems Power LED state. |
| SCF scfSystemCheckLED | 1.3.6.1.4.1.211.1.15.3.1.1.4.9 | ScfLEDState | read-only | Systems Check LED state. |
| scfSystemActualPowerConsumption | 1.3.6.1.4.1.211.1.15.3.1.1.4.10 | |||
| I32 scfSystemActualPowerConsumptionValue | 1.3.6.1.4.1.211.1.15.3.1.1.4.10.1 | Integer32 | read-only | Power consumption of the system. Set to 0 if this feature is not supported. |
| STR scfSystemActualPowerConsumptionUnit | 1.3.6.1.4.1.211.1.15.3.1.1.4.10.2 | DisplayString | read-only | Unit of system power consumption. |
| I32 scfSystemActualPowerMinPollingInterval | 1.3.6.1.4.1.211.1.15.3.1.1.4.10.3 | Integer32 | read-only | Minimum interval time in seconds between updates of scfSystemActualPowerConsumptionValue. It is strongly recommended to get object scfSystemActualPowerConsumptionValue with intervals longer than this value. It is meaningless to get value at smaller intervals, because, internally, scfSystemActualPowerConsumptionValue will not be updated. When this feature is not supported, maximum value of INTEGER type is set as interval value. |
| scfSystemAirFlow | 1.3.6.1.4.1.211.1.15.3.1.1.4.11 | |||
| I32 scfSystemExhaustAirFlowValue | 1.3.6.1.4.1.211.1.15.3.1.1.4.11.1 | Integer32 | read-only | Exhaust air flow of the system. Set to 0 if this feature is not supported. |
| STR scfSystemExhaustAirFlowUnit | 1.3.6.1.4.1.211.1.15.3.1.1.4.11.2 | DisplayString | read-only | Unit of system exhaust air flow. |
| I32 scfSystemExhaustAirFlowMinPollingInterval | 1.3.6.1.4.1.211.1.15.3.1.1.4.11.3 | Integer32 | read-only | Minimum interval time in seconds between updates of scfSystemExhaustAirFlowValue. It is strongly recommended to get object scfSystemExhaustAirFlowValue with intervals longer than this value. It is meaningless to get value at smaller intervals, because, internally, scfSystemExhaustAirFlowValue will not be updated. When this feature is not supported, maximum value of INTEGER type is set as interval value. |
| scfSystemAmbientTemperature | 1.3.6.1.4.1.211.1.15.3.1.1.4.12 | |||
| STR scfSystemAmbientTemperatureValue | 1.3.6.1.4.1.211.1.15.3.1.1.4.12.1 | DisplayString | read-only | Ambient temperature of the system. Set to 0 if this feature is not supported. |
| STR scfSystemAmbientTemperatureUnit | 1.3.6.1.4.1.211.1.15.3.1.1.4.12.2 | DisplayString | read-only | Unit of system ambient temperature. |
| I32 scfSystemAmbientTemperatureMinPollingInterval | 1.3.6.1.4.1.211.1.15.3.1.1.4.12.3 | Integer32 | read-only | Minimum interval time in seconds between updates of scfSystemAmbientTemperatureValue. It is strongly recommended to get object scfSystemAmbientTemperatureValue with intervals longer than this value. It is meaningless to get value at smaller intervals, because, internally, scfSystemAmbientTemperatureValue will not be updated. When this feature is not supported, maximum value of INTEGER type is set as interval value. |
| scfSystemPowerSource | 1.3.6.1.4.1.211.1.15.3.1.1.4.13 | |||
| scfSystemPermittedPowerConsumption | 1.3.6.1.4.1.211.1.15.3.1.1.4.14 | |||
| I32 scfSystemPermittedPowerConsumptionValue | 1.3.6.1.4.1.211.1.15.3.1.1.4.14.1 | Integer32 | read-only | Maximum power consumption, that a system will consume over all configurations. When this feature is not supported, 0 is set. |
| STR scfSystemPermittedPowerConsumptionUnit | 1.3.6.1.4.1.211.1.15.3.1.1.4.14.2 | DisplayString | read-only | Unit of power consumption. |
| scfSystemAvailablePowerConsumption | 1.3.6.1.4.1.211.1.15.3.1.1.4.15 | |||
| scfDomainInfo | 1.3.6.1.4.1.211.1.15.3.1.1.5 | |||
| I32 scfDomainNumber | 1.3.6.1.4.1.211.1.15.3.1.1.5.1 | Integer32 | read-only | Total count of Domain Table entries. |
| scfDomainTable | 1.3.6.1.4.1.211.1.15.3.1.1.5.2 | not-accessible | Domain table. | |
| scfDomainEntry | 1.3.6.1.4.1.211.1.15.3.1.1.5.2.1 | not-accessible | Domain table entry. | |
| SCF scfDomainId | 1.3.6.1.4.1.211.1.15.3.1.1.5.2.1.1 | ScfIndex | read-only | Domain ID. |
| I32 scfDomainCpuNumber | 1.3.6.1.4.1.211.1.15.3.1.1.5.2.1.2 | Integer32 | read-only | Total number of CPUs/Strands in this domain. |
| I32 scfDomainMemoryCapacity | 1.3.6.1.4.1.211.1.15.3.1.1.5.2.1.3 | Integer32 | read-only | Memory capacity of this domain. |
| STR scfDomainObpVersion | 1.3.6.1.4.1.211.1.15.3.1.1.5.2.1.4 | DisplayString | read-only | Version of OBP firmware. |
| STR scfDomainObpAdditionalInfo | 1.3.6.1.4.1.211.1.15.3.1.1.5.2.1.5 | DisplayString | read-only | Additional OBP information. |
| STR scfDomainOsMachine | 1.3.6.1.4.1.211.1.15.3.1.1.5.2.1.6 | DisplayString | read-only | Domain machine hardware name. |
| STR scfDomainOsRelease | 1.3.6.1.4.1.211.1.15.3.1.1.5.2.1.7 | DisplayString | read-only | OS release level. |
| STR scfDomainOsSysName | 1.3.6.1.4.1.211.1.15.3.1.1.5.2.1.8 | DisplayString | read-only | OS Name. |
| STR scfDomainOsNodeName | 1.3.6.1.4.1.211.1.15.3.1.1.5.2.1.9 | DisplayString | read-only | OS network node hostname. |
| STR scfDomainOsVersion | 1.3.6.1.4.1.211.1.15.3.1.1.5.2.1.10 | DisplayString | read-only | Version of the OS. |
| STR scfDomainOsAdditionalInfo | 1.3.6.1.4.1.211.1.15.3.1.1.5.2.1.11 | DisplayString | read-only | Additional OS information. |
| SCF scfDomainValid | 1.3.6.1.4.1.211.1.15.3.1.1.5.2.1.12 | ScfValidStatus | read-only | Validity of the domain. |
| STR scfDomainXsbs | 1.3.6.1.4.1.211.1.15.3.1.1.5.2.1.13 | DisplayString | read-only | List of XSBs contained in this domain. |
| SCF scfDomainStatus | 1.3.6.1.4.1.211.1.15.3.1.1.5.2.1.14 | ScfDomainStatusTC | read-only | Domain operational status. |
| SCF scfDomainErrorStatus | 1.3.6.1.4.1.211.1.15.3.1.1.5.2.1.15 | ScfErrorStatus | read-only | Domain error status. |
| SCF scfDomainConfigurationPolicy | 1.3.6.1.4.1.211.1.15.3.1.1.5.2.1.16 | ScfDomainConfigPolicy | read-only | The DCL configuration policy of this domain. |
| scfXsbInfo | 1.3.6.1.4.1.211.1.15.3.1.1.6 | |||
| I32 scfXsbType | 1.3.6.1.4.1.211.1.15.3.1.1.6.1 | Integer32 | read-only | Type of XSB rule for the system. |
| I32 scfXsbNumber | 1.3.6.1.4.1.211.1.15.3.1.1.6.2 | Integer32 | read-only | Total count of XSB Table entries. |
| scfXsbTable | 1.3.6.1.4.1.211.1.15.3.1.1.6.3 | not-accessible | XSB table. | |
| scfXsbEntry | 1.3.6.1.4.1.211.1.15.3.1.1.6.3.1 | not-accessible | XSB table entry. | |
| SCF scfXsbId | 1.3.6.1.4.1.211.1.15.3.1.1.6.3.1.1 | ScfXsbIndex | read-only | XSB ID. |
| SCF scfXsbStatus | 1.3.6.1.4.1.211.1.15.3.1.1.6.3.1.2 | ScfStateTC | read-only | XSB operational state. |
| SCF scfXsbErrorStatus | 1.3.6.1.4.1.211.1.15.3.1.1.6.3.1.3 | ScfErrorStatus | read-only | XSB error status. |
| I32 scfXsbDomainId | 1.3.6.1.4.1.211.1.15.3.1.1.6.3.1.4 | Integer32 | read-only | Active domain ID of the XSB. |
| SCF scfXsbDrStatus | 1.3.6.1.4.1.211.1.15.3.1.1.6.3.1.5 | ScfDRState | read-only | Domain reconfiguration status of the XSB. |
| SCF scfXsbSubStatusPower | 1.3.6.1.4.1.211.1.15.3.1.1.6.3.1.6 | ScfUsageState | read-only | XSB detail status power state. |
| SCF scfXsbSubStatusTest | 1.3.6.1.4.1.211.1.15.3.1.1.6.3.1.7 | ScfTestState | read-only | XSB detail status test state. |
| SCF scfXsbSubStatusAssignment | 1.3.6.1.4.1.211.1.15.3.1.1.6.3.1.8 | ScfAssignmentState | read-only | XSB detail status assignment state. |
| SCF scfXsbSubStatusConnectivity | 1.3.6.1.4.1.211.1.15.3.1.1.6.3.1.9 | ScfConnectivityState | read-only | XSB detail status conectivity state. |
| SCF scfXsbSubStatusConfiguration | 1.3.6.1.4.1.211.1.15.3.1.1.6.3.1.10 | ScfConfigurationState | read-only | XSB detail status configuration state. |
| I32 scfXsbSetupDID | 1.3.6.1.4.1.211.1.15.3.1.1.6.3.1.11 | Integer32 | read-only | The Setup Domain ID. Shows the Domain ID where the XSB will be added. |
| I32 scfXsbNextDID | 1.3.6.1.4.1.211.1.15.3.1.1.6.3.1.12 | Integer32 | read-only | Next Domain ID. Shows the Domain ID where the XSB is preassigned. |
| scfLsbInfo | 1.3.6.1.4.1.211.1.15.3.1.1.7 | |||
| I32 scfLsbType | 1.3.6.1.4.1.211.1.15.3.1.1.7.1 | Integer32 | read-only | Type of LSB rule for this system. |
| I32 scfLsbNumber | 1.3.6.1.4.1.211.1.15.3.1.1.7.2 | Integer32 | read-only | Total count of LSB Table entries. |
| scfLsbTable | 1.3.6.1.4.1.211.1.15.3.1.1.7.3 | not-accessible | LSB table. | |
| scfLsbEntry | 1.3.6.1.4.1.211.1.15.3.1.1.7.3.1 | not-accessible | LSB table entry. | |
| SCF scfLsbDomainId | 1.3.6.1.4.1.211.1.15.3.1.1.7.3.1.1 | ScfIndex | read-only | LSB Domain ID. |
| SCF scfLsbId | 1.3.6.1.4.1.211.1.15.3.1.1.7.3.1.2 | ScfIndex | read-only | LSB ID. |
| STR scfLsbXsbId | 1.3.6.1.4.1.211.1.15.3.1.1.7.3.1.3 | DisplayString | read-only | Current XSB ID that is registered to this LSB. |
| SCF scfLsbNoMem | 1.3.6.1.4.1.211.1.15.3.1.1.7.3.1.4 | ScfUsageState | read-only | DCL no-mem use setting. Reflects if the memory which is part of this LSB should not be used in the Domain. |
| SCF scfLsbNoIo | 1.3.6.1.4.1.211.1.15.3.1.1.7.3.1.5 | ScfUsageState | read-only | DCL no-io use setting. Reflects if the I/O which is part of this LSB should not be used in the Domain |
| SCF scfLsbFloatingBoard | 1.3.6.1.4.1.211.1.15.3.1.1.7.3.1.6 | ScfUsageState | read-only | DCL floating board use setting. Reflects if the LSB is considered a floating board which eases DR operations. |
| scfBoardInfo | 1.3.6.1.4.1.211.1.15.3.1.1.8 | |||
| I32 scfBoardNumber | 1.3.6.1.4.1.211.1.15.3.1.1.8.1 | Integer32 | read-only | Total count of Board Table entries. |
| scfBoardTable | 1.3.6.1.4.1.211.1.15.3.1.1.8.2 | not-accessible | Board table. | |
| scfBoardEntry | 1.3.6.1.4.1.211.1.15.3.1.1.8.2.1 | not-accessible | Board table entry. | |
| SCF scfBoardType | 1.3.6.1.4.1.211.1.15.3.1.1.8.2.1.1 | ScfComponentType | read-only | Board type. |
| SCF scfBoardId | 1.3.6.1.4.1.211.1.15.3.1.1.8.2.1.2 | ScfIndex | read-only | Board ID. |
| STR scfBoardName | 1.3.6.1.4.1.211.1.15.3.1.1.8.2.1.3 | DisplayString | read-only | Board description. |
| STR scfBoardAdditionalInfo | 1.3.6.1.4.1.211.1.15.3.1.1.8.2.1.4 | DisplayString | read-only | Additional board info. |
| I32 scfBoardXsbs | 1.3.6.1.4.1.211.1.15.3.1.1.8.2.1.5 | Integer32 | read-only | The total number of XSB partitions for this board. |
| SCF scfBoardState | 1.3.6.1.4.1.211.1.15.3.1.1.8.2.1.6 | ScfStateTC | read-only | Board operating state. |
| SCF scfBoardCODEnabled | 1.3.6.1.4.1.211.1.15.3.1.1.8.2.1.7 | ScfCodState | read-only | COD State of the board. |
| SCF scfBoardSubType | 1.3.6.1.4.1.211.1.15.3.1.1.8.2.1.8 | ScfBoardSubTypeTC | read-only | Board subtype. |
| scfCpuInfo | 1.3.6.1.4.1.211.1.15.3.1.1.9 | |||
| I32 scfCpuNumber | 1.3.6.1.4.1.211.1.15.3.1.1.9.1 | Integer32 | read-only | Total count of CPU Table entries. |
| scfCpuTable | 1.3.6.1.4.1.211.1.15.3.1.1.9.2 | not-accessible | CPU table. | |
| scfCpuEntry | 1.3.6.1.4.1.211.1.15.3.1.1.9.2.1 | not-accessible | CPU table entry. | |
| SCF scfCpuBoardType | 1.3.6.1.4.1.211.1.15.3.1.1.9.2.1.1 | ScfComponentType | read-only | CPU board type. |
| SCF scfCpuBoardId | 1.3.6.1.4.1.211.1.15.3.1.1.9.2.1.2 | ScfIndex | read-only | CPU board ID. |
| SCF scfCpuModuleType | 1.3.6.1.4.1.211.1.15.3.1.1.9.2.1.3 | ScfComponentType | read-only | CPU module type. |
| SCF scfCpuModuleId | 1.3.6.1.4.1.211.1.15.3.1.1.9.2.1.4 | ScfIndex | read-only | CPU module ID. |
| SCF scfCpuSubType | 1.3.6.1.4.1.211.1.15.3.1.1.9.2.1.5 | ScfComponentType | read-only | CPU sub-part type. |
| SCF scfCpuSubId | 1.3.6.1.4.1.211.1.15.3.1.1.9.2.1.6 | ScfIndex | read-only | CPU sub-part ID. |
| STR scfCpuType | 1.3.6.1.4.1.211.1.15.3.1.1.9.2.1.7 | DisplayString | read-only | CPU type. |
| I32 scfCpuFrequency | 1.3.6.1.4.1.211.1.15.3.1.1.9.2.1.8 | Integer32 | read-only | CPU frequency. |
| STR scfCpuAdditionalInfo | 1.3.6.1.4.1.211.1.15.3.1.1.9.2.1.9 | DisplayString | read-only | Additional CPU info. |
| SCF scfCpuState | 1.3.6.1.4.1.211.1.15.3.1.1.9.2.1.10 | ScfStateTC | read-only | CPU operating state. |
| scfMemoryInfo | 1.3.6.1.4.1.211.1.15.3.1.1.10 | |||
| I32 scfMemoryNumber | 1.3.6.1.4.1.211.1.15.3.1.1.10.1 | Integer32 | read-only | Total count of Memory Table entries. |
| scfMemoryTable | 1.3.6.1.4.1.211.1.15.3.1.1.10.2 | not-accessible | Memory card table. | |
| scfMemoryEntry | 1.3.6.1.4.1.211.1.15.3.1.1.10.2.1 | not-accessible | Memory card table entry. | |
| SCF scfMemoryBoardType | 1.3.6.1.4.1.211.1.15.3.1.1.10.2.1.1 | ScfComponentType | read-only | Memory board type. |
| SCF scfMemoryBoardId | 1.3.6.1.4.1.211.1.15.3.1.1.10.2.1.2 | ScfIndex | read-only | Memory board ID. |
| SCF scfMemoryModuleType | 1.3.6.1.4.1.211.1.15.3.1.1.10.2.1.3 | ScfComponentType | read-only | Memory module type. |
| SCF scfMemoryModuleId | 1.3.6.1.4.1.211.1.15.3.1.1.10.2.1.4 | ScfIndex | read-only | Memory module ID. |
| SCF scfMemorySubType | 1.3.6.1.4.1.211.1.15.3.1.1.10.2.1.5 | ScfComponentType | read-only | Memory sub-part type. |
| SCF scfMemorySubId | 1.3.6.1.4.1.211.1.15.3.1.1.10.2.1.6 | ScfIndex | read-only | Memory sub-part ID. |
| STR scfMemoryName | 1.3.6.1.4.1.211.1.15.3.1.1.10.2.1.7 | DisplayString | read-only | Memory Name. This object provides the actual nomenclature specific name for this piece of memory. i.e. 02A, 13B |
| I32 scfMemoryCapacity | 1.3.6.1.4.1.211.1.15.3.1.1.10.2.1.8 | Integer32 | read-only | Memory capacity. |
| STR scfMemoryAdditionalInfo | 1.3.6.1.4.1.211.1.15.3.1.1.10.2.1.9 | DisplayString | read-only | Additional Memory info. |
| SCF scfMemoryState | 1.3.6.1.4.1.211.1.15.3.1.1.10.2.1.10 | ScfStateTC | read-only | Operation state of the memory. |
| scfIoBoxInfo | 1.3.6.1.4.1.211.1.15.3.1.1.11 | |||
| I32 scfIoBoxNumber | 1.3.6.1.4.1.211.1.15.3.1.1.11.1 | Integer32 | read-only | Total count of I/O Box Table entries. |
| scfIoBoxTable | 1.3.6.1.4.1.211.1.15.3.1.1.11.2 | not-accessible | I/O Box table. | |
| scfIoBoxEntry | 1.3.6.1.4.1.211.1.15.3.1.1.11.2.1 | not-accessible | I/O Box entry. | |
| SCF scfIoBoxId | 1.3.6.1.4.1.211.1.15.3.1.1.11.2.1.1 | ScfIoBoxIndex | read-only | Unique I/O Box identifier. The persistent unique identifier for an I/O Box is it's serial number. |
| SCF scfIoBoxLocationLED | 1.3.6.1.4.1.211.1.15.3.1.1.11.2.1.2 | ScfIoBoxLEDState | read-only | State of the Location LED. |
| SCF scfIoBoxOverTempLED | 1.3.6.1.4.1.211.1.15.3.1.1.11.2.1.3 | ScfIoBoxLEDState | read-only | State of the Over Temperature LED. |
| SCF scfIoBoxServiceReqLED | 1.3.6.1.4.1.211.1.15.3.1.1.11.2.1.4 | ScfIoBoxLEDState | read-only | State of the Service Request LED. |
| SCF scfIoBoxActiveLED | 1.3.6.1.4.1.211.1.15.3.1.1.11.2.1.5 | ScfIoBoxLEDState | read-only | State of the Active LED. |
| STR scfIoBoxPartNumber | 1.3.6.1.4.1.211.1.15.3.1.1.11.2.1.6 | DisplayString | read-only | I/O Box part number. |
| STR scfIoBoxSerialNumber | 1.3.6.1.4.1.211.1.15.3.1.1.11.2.1.7 | DisplayString | read-only | I/O Box serial number. |
| STR scfIoBoxDashLevel | 1.3.6.1.4.1.211.1.15.3.1.1.11.2.1.8 | DisplayString | read-only | I/O Box dash level. |
| I32 scfIoBoatNumber | 1.3.6.1.4.1.211.1.15.3.1.1.11.3 | Integer32 | read-only | Total count of I/O Boat Table entries. |
| scfIoBoatTable | 1.3.6.1.4.1.211.1.15.3.1.1.11.4 | not-accessible | I/O Boat table. | |
| scfIoBoatEntry | 1.3.6.1.4.1.211.1.15.3.1.1.11.4.1 | not-accessible | I/O Boat entry. This entry is indexed by the I/O Box ID the Boat is contained in, as well as the Boat identifier. | |
| SCF scfIoBoatIoBoxId | 1.3.6.1.4.1.211.1.15.3.1.1.11.4.1.1 | ScfIoBoxIndex | read-only | Unique I/O Box identifier. The persistent unique identifier for an I/O Box is it's serial number. |
| SCF scfIoBoatId | 1.3.6.1.4.1.211.1.15.3.1.1.11.4.1.2 | ScfIndex | read-only | Unique I/O Boat identifier |
| SCF scfIoBoatLocation | 1.3.6.1.4.1.211.1.15.3.1.1.11.4.1.3 | ScfIoBoxComponentLocation | read-only | Slot location in I/O Box. |
| SCF scfIoBoatType | 1.3.6.1.4.1.211.1.15.3.1.1.11.4.1.4 | ScfIoBoatTypeTC | read-only | I/O Boat Type. |
| SCF scfIoBoatOKtoRemoveLED | 1.3.6.1.4.1.211.1.15.3.1.1.11.4.1.5 | ScfIoBoxLEDState | read-only | State of the I/O Boat Removal LED. |
| SCF scfIoBoatServiceReqLED | 1.3.6.1.4.1.211.1.15.3.1.1.11.4.1.6 | ScfIoBoxLEDState | read-only | State of the Service Request LED. |
| SCF scfIoBoatActiveLED | 1.3.6.1.4.1.211.1.15.3.1.1.11.4.1.7 | ScfIoBoxLEDState | read-only | State of the Active LED. |
| STR scfIoBoatPartNumber | 1.3.6.1.4.1.211.1.15.3.1.1.11.4.1.8 | DisplayString | read-only | I/O Boat part number. |
| STR scfIoBoatSerialNumber | 1.3.6.1.4.1.211.1.15.3.1.1.11.4.1.9 | DisplayString | read-only | I/O Boat serial number. |
| STR scfIoBoatDashLevel | 1.3.6.1.4.1.211.1.15.3.1.1.11.4.1.10 | DisplayString | read-only | I/O Boat dash level. |
| I32 scfLinkCardNumber | 1.3.6.1.4.1.211.1.15.3.1.1.11.5 | Integer32 | read-only | Total count of I/O Boat Link Card Table entries. |
| scfLinkCardTable | 1.3.6.1.4.1.211.1.15.3.1.1.11.6 | not-accessible | I/O Box Link Card table. | |
| scfLinkCardEntry | 1.3.6.1.4.1.211.1.15.3.1.1.11.6.1 | not-accessible | PCI-E Link Card Table Entry. This entry is indexed by the I/O Box container hierarchy, where the link card is contained in the boat and the boat is contained in the box. | |
| SCF scfLinkCardIoBoxId | 1.3.6.1.4.1.211.1.15.3.1.1.11.6.1.1 | ScfIoBoxIndex | read-only | Unique I/O Box identifier. The persistent unique identifier for an I/O Box is it's serial number. |
| SCF scfLinkCardIoBoatId | 1.3.6.1.4.1.211.1.15.3.1.1.11.6.1.2 | ScfIndex | read-only | Unique I/O Boat identifier |
| SCF scfLinkCardId | 1.3.6.1.4.1.211.1.15.3.1.1.11.6.1.3 | ScfIndex | read-only | Unique Link Card identifier. |
| SCF scfLinkCardDataLED | 1.3.6.1.4.1.211.1.15.3.1.1.11.6.1.4 | ScfIoBoxLEDState | read-only | State of the Data LED. |
| SCF scfLinkCardMgmtLED | 1.3.6.1.4.1.211.1.15.3.1.1.11.6.1.5 | ScfIoBoxLEDState | read-only | State of the Management LED. |
| STR scfLinkCardDownlinkCardLocation | 1.3.6.1.4.1.211.1.15.3.1.1.11.6.1.6 | DisplayString | read-only | Link Card counterpart card location on the Host IOU. |
| I32 scfLinkCardDownlinkCardId | 1.3.6.1.4.1.211.1.15.3.1.1.11.6.1.7 | Integer32 | read-only | Link Card counterpart card ID on the Host IOU. |
| STR scfLinkCardPartNumber | 1.3.6.1.4.1.211.1.15.3.1.1.11.6.1.8 | DisplayString | read-only | Link Card part number. |
| STR scfLinkCardSerialNumber | 1.3.6.1.4.1.211.1.15.3.1.1.11.6.1.9 | DisplayString | read-only | Link Card serial number. |
| STR scfLinkCardDashLevel | 1.3.6.1.4.1.211.1.15.3.1.1.11.6.1.10 | DisplayString | read-only | Link Card dash level. |
| I32 scfPowerSupplyFanNumber | 1.3.6.1.4.1.211.1.15.3.1.1.11.7 | Integer32 | read-only | Total count of I/O Box Power Supply/Fan Table entries. |
| scfPowerSupplyFanTable | 1.3.6.1.4.1.211.1.15.3.1.1.11.8 | not-accessible | IOBox Power Supply/Fan Table. | |
| scfPowerSupplyFanEntry | 1.3.6.1.4.1.211.1.15.3.1.1.11.8.1 | not-accessible | I/O Box Power Supply/Fan Table Entry. This entry is indexed by the I/O Box ID the PS/Fan is contained in, as well as the PS/Fan identifier. | |
| SCF scfPowerSupplyFanIoBoxId | 1.3.6.1.4.1.211.1.15.3.1.1.11.8.1.1 | ScfIoBoxIndex | read-only | Unique I/O Box identifier. The persistent unique identifier for an I/O Box is it's serial number. |
| SCF scfPowerSupplyFanId | 1.3.6.1.4.1.211.1.15.3.1.1.11.8.1.2 | ScfIndex | read-only | IOBox Power Supply/Fan identifier. |
| SCF scfPowerSupplyFanLocation | 1.3.6.1.4.1.211.1.15.3.1.1.11.8.1.3 | ScfIoBoxComponentLocation | read-only | Slot location in IOBox. |
| SCF scfPowerSupplyFanOKtoRemoveLED | 1.3.6.1.4.1.211.1.15.3.1.1.11.8.1.4 | ScfIoBoxLEDState | read-only | State of the Power Supply Fan Removal LED. |
| SCF scfPowerSupplyFanServiceReqLED | 1.3.6.1.4.1.211.1.15.3.1.1.11.8.1.5 | ScfIoBoxLEDState | read-only | State of the Service Request LED. |
| SCF scfPowerSupplyFanACPowerLED | 1.3.6.1.4.1.211.1.15.3.1.1.11.8.1.6 | ScfIoBoxLEDState | read-only | State of the A/C Power LED. |
| SCF scfPowerSupplyFanDCPowerLED | 1.3.6.1.4.1.211.1.15.3.1.1.11.8.1.7 | ScfIoBoxLEDState | read-only | State of the D/C Power LED. |
| STR scfPowerSupplyFanPartNumber | 1.3.6.1.4.1.211.1.15.3.1.1.11.8.1.8 | DisplayString | read-only | PowerSupply/Fan part number. |
| STR scfPowerSupplyFanSerialNumber | 1.3.6.1.4.1.211.1.15.3.1.1.11.8.1.9 | DisplayString | read-only | PowerSupply/Fan serial number. |
| STR scfPowerSupplyFanDashLevel | 1.3.6.1.4.1.211.1.15.3.1.1.11.8.1.10 | DisplayString | read-only | PowerSupply/Fan dash level. |
| I32 scfIoBoxSensorNumber | 1.3.6.1.4.1.211.1.15.3.1.1.11.9 | Integer32 | read-only | Total count of I/O Box environmental sensor table entries. |
| scfIoBoxSensorTable | 1.3.6.1.4.1.211.1.15.3.1.1.11.10 | not-accessible | I/O Box environmental sensor table. | |
| scfIoBoxSensorEntry | 1.3.6.1.4.1.211.1.15.3.1.1.11.10.1 | not-accessible | I/O Box environmental sensor entry. | |
| SCF scfIoBoxSensorIoBoxId | 1.3.6.1.4.1.211.1.15.3.1.1.11.10.1.1 | ScfIoBoxIndex | read-only | Unique I/O Box identifier for a sensor entry. The persistent unique identifier for an I/O Box is it's serial number. |
| SCF scfIoBoxSensorIoBoxSubType | 1.3.6.1.4.1.211.1.15.3.1.1.11.10.1.2 | ScfIoBoxComponentType | read-only | Type of the I/O Box component that the sensor is located. |
| SCF scfIoBoxSensorIoBoxSubId | 1.3.6.1.4.1.211.1.15.3.1.1.11.10.1.3 | ScfIndex | read-only | Identifier for the I/O Box component that the sensor is located. |
| SCF scfIoBoxSensorId | 1.3.6.1.4.1.211.1.15.3.1.1.11.10.1.4 | ScfIndex | read-only | Identifier of the sensor. |
| STR scfIoBoxSensorDescription | 1.3.6.1.4.1.211.1.15.3.1.1.11.10.1.5 | DisplayString | read-only | A description of the environmental sensor. |
| STR scfIoBoxSensorUnits | 1.3.6.1.4.1.211.1.15.3.1.1.11.10.1.6 | DisplayString | read-only | The units for the environmental sensor value. |
| I32 scfIoBoxSensorValue | 1.3.6.1.4.1.211.1.15.3.1.1.11.10.1.7 | Integer32 | read-only | The value read from the environmental sensor. This object can be compared with the Sensor Minimum Alarm and Maximum Alarm objects in this table to determine the value status. In addition, the Enabled Alarm should be used to determine what this value can be compared against, MinAlarm, MaxAlarm, or both. If a value has exceeded the Minimum or Maximum, then the user will be notified through a change in the I/O Box component LED or temperature event trap. Through the comparisions described here, further information can be gathered as to the cause. |
| SCF scfIoBoxSensorEnabledAlarms | 1.3.6.1.4.1.211.1.15.3.1.1.11.10.1.8 | ScfIoBoxEnabledAlarms | read-only | The environmental alarm threshold values to be utilized for this sensor. The values immediately follow this object. |
| I32 scfIoBoxSensorMinAlarm | 1.3.6.1.4.1.211.1.15.3.1.1.11.10.1.9 | Integer32 | read-only | The environmental sensor minimum threshold value before an alarm is generated. Not utilized for all sensors. |
| I32 scfIoBoxSensorMaxAlarm | 1.3.6.1.4.1.211.1.15.3.1.1.11.10.1.10 | Integer32 | read-only | The environmental sensor maximum threshold value before an alarm is generated. Not utilized for all sensors. |
| scfComponentInfo | 1.3.6.1.4.1.211.1.15.3.1.1.12 | |||
| I32 scfComponentNumber | 1.3.6.1.4.1.211.1.15.3.1.1.12.1 | Integer32 | read-only | Total count of Component Table entries. |
| scfComponentTable | 1.3.6.1.4.1.211.1.15.3.1.1.12.2 | not-accessible | Hardware Component table. | |
| scfComponentEntry | 1.3.6.1.4.1.211.1.15.3.1.1.12.2.1 | not-accessible | Component table entry. | |
| SCF scfComponentBoardType | 1.3.6.1.4.1.211.1.15.3.1.1.12.2.1.1 | ScfComponentType | read-only | Component board type. |
| SCF scfComponentBoardId | 1.3.6.1.4.1.211.1.15.3.1.1.12.2.1.2 | ScfIndex | read-only | Component board ID. |
| SCF scfComponentModuleType | 1.3.6.1.4.1.211.1.15.3.1.1.12.2.1.3 | ScfComponentType | read-only | Component module type. |
| SCF scfComponentModuleId | 1.3.6.1.4.1.211.1.15.3.1.1.12.2.1.4 | ScfIndex | read-only | Component module ID. |
| SCF scfComponentSubType | 1.3.6.1.4.1.211.1.15.3.1.1.12.2.1.5 | ScfComponentType | read-only | Component sub-part type. |
| SCF scfComponentSubId | 1.3.6.1.4.1.211.1.15.3.1.1.12.2.1.6 | ScfIndex | read-only | Component sub-part ID. |
| STR scfComponentAdditionalInfo | 1.3.6.1.4.1.211.1.15.3.1.1.12.2.1.7 | DisplayString | read-only | Additional component info. |
| STR scfComponentPartNumber | 1.3.6.1.4.1.211.1.15.3.1.1.12.2.1.8 | DisplayString | read-only | Component part number. |
| STR scfComponentSerialNumber | 1.3.6.1.4.1.211.1.15.3.1.1.12.2.1.9 | DisplayString | read-only | Component serial number. |
| STR scfComponentProductName | 1.3.6.1.4.1.211.1.15.3.1.1.12.2.1.10 | DisplayString | read-only | Component product name. |
| STR scfComponentManufacturer | 1.3.6.1.4.1.211.1.15.3.1.1.12.2.1.11 | DisplayString | read-only | Component manufacturer. |
| STR scfComponentManufactureDate | 1.3.6.1.4.1.211.1.15.3.1.1.12.2.1.12 | DisplayString | read-only | Component manufacture date. This date varies for different components. For many components this object will provide IPMI format, which is 3 bytes of the number of minutes from 0:00 hrs 1/1/96. In this case the most significant byte is first. In some components, 2 bytes will be provided with the first byte year(yy) in binary-coded decimal(BCD), and the second byte week(ww) in BCD. |
| SCF scfComponentStatus | 1.3.6.1.4.1.211.1.15.3.1.1.12.2.1.13 | ScfStateTC | read-only | Component operational status. |
| SCF scfComponentErrorStatus | 1.3.6.1.4.1.211.1.15.3.1.1.12.2.1.14 | ScfErrorStatus | read-only | Error status of component. |
| scfMIBTraps | 1.3.6.1.4.1.211.1.15.3.1.2 | |||
| scfMIBTrapPrefix | 1.3.6.1.4.1.211.1.15.3.1.2.0 | |||
| NTF scfSPFailover | 1.3.6.1.4.1.211.1.15.3.1.2.0.1 | Indicates that a failover from the active SP to the standby SP has occurred. The Board ID included is the ID of the SP that has been failed over to. | ||
| NTF scfComponentEvent | 1.3.6.1.4.1.211.1.15.3.1.2.0.2 | Indicates that a component has been added to or removed from the system, or that a component-specific event has occurred. When indicating that a component has been added to or removed from the system, the event will be based on the highest level component possible. For example, if a CMU is removed, then only a trap for the CMU is generated and not for the CPU and Memory that are on that CMU. | ||
| NTF scfComponentStatusEvent | 1.3.6.1.4.1.211.1.15.3.1.2.0.3 | Indicates that a component has changed to a status of interest, including fault, degraded, and recovery from a previous fault or degraded state condition. | ||
| NTF scfXsbModeChangeEvent | 1.3.6.1.4.1.211.1.15.3.1.2.0.4 | Indicates that an XSB mode has been changed to either a divided or non-divided state. | ||
| NTF scfDomainStatusAlarm | 1.3.6.1.4.1.211.1.15.3.1.2.0.5 | Indicates that a status alarm condition has occurred on a domain. This includes a status change and a panic. | ||
| NTF scfDomainXsbEvent | 1.3.6.1.4.1.211.1.15.3.1.2.0.6 | Indicates that an XSB has been added to or removed from a domain. | ||
| NTF scfIoBoxEvent | 1.3.6.1.4.1.211.1.15.3.1.2.0.7 | Indicates that an I/O Box component has been added to or removed from the system. | ||
| NTF scfIoBoxLedEvent | 1.3.6.1.4.1.211.1.15.3.1.2.0.8 | Indicates that an I/O Box component LED changed. Depending on the LED type, this will notify of errors detected in an I/O Box component. | ||
| NTF scfIoBoxTemperatureEvent | 1.3.6.1.4.1.211.1.15.3.1.2.0.9 | Indicates that an I/O Box temperature sensor has triggered an event. | ||
| NTF scfModeSwitchEvent | 1.3.6.1.4.1.211.1.15.3.1.2.0.10 | Indicates that a panel switch has triggered an event. | ||
| scfMIBTrapData | 1.3.6.1.4.1.211.1.15.3.1.2.1 | |||
| SCF scfTrapEventType | 1.3.6.1.4.1.211.1.15.3.1.2.1.1 | ScfTrapEventTypeTC | accessible-for-notify | The event type of this notification. This provides additional information on the reason that the notification was sent. |
| SCF scfTrapStatusEventType | 1.3.6.1.4.1.211.1.15.3.1.2.1.2 | ScfTrapStatusEventTypeTC | accessible-for-notify | The status event type of this notification. This provides additional information on the reason that the notification was sent. |
| SCF scfTrapDomainStatusAlarmType | 1.3.6.1.4.1.211.1.15.3.1.2.1.3 | ScfDomainStatusAlarmType | accessible-for-notify | The type of this domain alarm that provides additional information on the reason that the notification was sent. |
| SCF scfTrapIoBoxId | 1.3.6.1.4.1.211.1.15.3.1.2.1.4 | ScfIoBoxIndex | accessible-for-notify | Trap unique I/O Box identifier. The persistent unique identifier for an I/O Box is it's serial number. |
| SCF scfTrapIoBoxSubType | 1.3.6.1.4.1.211.1.15.3.1.2.1.5 | ScfIoBoxComponentType | accessible-for-notify | Type of the I/O Box component that a trap originated from. |
| SCF scfTrapIoBoxSubId | 1.3.6.1.4.1.211.1.15.3.1.2.1.6 | ScfIndex | accessible-for-notify | Identifier for the I/O Box component that a trap originated from. |
| SCF scfTrapIoBoxTempEventType | 1.3.6.1.4.1.211.1.15.3.1.2.1.7 | ScfTrapIoBoxTempEventTypeTC | accessible-for-notify | The event type of this notification. This provides additional information on the reason that the notification was sent. |
| SCF scfTrapIoBoxLedType | 1.3.6.1.4.1.211.1.15.3.1.2.1.8 | ScfIoBoxLEDType | accessible-for-notify | LED Type for the I/O Box component that a trap originated from. |
| SCF scfTrapIoBoxLedValue | 1.3.6.1.4.1.211.1.15.3.1.2.1.9 | ScfIoBoxLEDState | accessible-for-notify | LED Value for the I/O Box component LED that a trap originated from. |
| SCF scfTrapModeSwitchEventType | 1.3.6.1.4.1.211.1.15.3.1.2.1.10 | ScfTrapModeSwitchEventTypeTC | accessible-for-notify | The panel switch event type of this notification. This provides additional information on the reason that the notification was sent. |
| scfMIBConformances | 1.3.6.1.4.1.211.1.15.3.1.3 | |||
| scfMIBCompliances | 1.3.6.1.4.1.211.1.15.3.1.3.1 | |||
| scfCompliance | 1.3.6.1.4.1.211.1.15.3.1.3.1.1 | The compliance statement for SNMP entities which implement this MIB. | ||
| scfMIBGroups | 1.3.6.1.4.1.211.1.15.3.1.3.2 | |||
| scfMIBObjectGroups | 1.3.6.1.4.1.211.1.15.3.1.3.2.1 | |||
| scfInfoGroup | 1.3.6.1.4.1.211.1.15.3.1.3.2.1.1 | A collection of objects providing SCF SNMP Agent information. | ||
| scfStateGroup | 1.3.6.1.4.1.211.1.15.3.1.3.2.1.2 | A collection of objects providing overall SCF state information. | ||
| scfMonitorInfoGroup | 1.3.6.1.4.1.211.1.15.3.1.3.2.1.3 | A collection of objects providing environmental (temperature, voltage, rotation) monitoring information for platform components. | ||
| scfSystemInfoGroup | 1.3.6.1.4.1.211.1.15.3.1.3.2.1.4 | A collection of objects providing System information. | ||
| scfDomainInfoGroup | 1.3.6.1.4.1.211.1.15.3.1.3.2.1.5 | A collection of objects providing Domain information. | ||
| scfXsbInfoGroup | 1.3.6.1.4.1.211.1.15.3.1.3.2.1.6 | A collection of objects providing XSB information. | ||
| scfLsbInfoGroup | 1.3.6.1.4.1.211.1.15.3.1.3.2.1.7 | A collection of objects providing LSB information. | ||
| scfBoardInfoGroup | 1.3.6.1.4.1.211.1.15.3.1.3.2.1.8 | A collection of objects providing Board(CMU/IOU) information. | ||
| scfCpuInfoGroup | 1.3.6.1.4.1.211.1.15.3.1.3.2.1.9 | A collection of objects providing CPU Module information. | ||
| scfMemoryInfoGroup | 1.3.6.1.4.1.211.1.15.3.1.3.2.1.10 | A collection of objects providing Memory information. | ||
| scfIoBoxInfoGroup | 1.3.6.1.4.1.211.1.15.3.1.3.2.1.11 | A collection of objects providing I/O Box information. | ||
| scfComponentInfoGroup | 1.3.6.1.4.1.211.1.15.3.1.3.2.1.12 | A collection of objects providing physical component information. | ||
| scfNotificationObjectGroup | 1.3.6.1.4.1.211.1.15.3.1.3.2.1.13 | The collection of notification objects used to indicate events, alarms, and state changes that occur in the system. | ||
| scfSystemActualPowerConsumptionGroup | 1.3.6.1.4.1.211.1.15.3.1.3.2.1.14 | A collection of objects providing System Actual Power Consumption information. | ||
| scfSystemAmbientTemperatureGroup | 1.3.6.1.4.1.211.1.15.3.1.3.2.1.15 | A collection of objects providing System Ambient Temperature information. | ||
| scfSystemPermittedPowerConsumptionGroup | 1.3.6.1.4.1.211.1.15.3.1.3.2.1.16 | A collection of objects providing System Permitted Power Consumption information. | ||
| scfSystemAirFlowGroup | 1.3.6.1.4.1.211.1.15.3.1.3.2.1.17 | A collection of objects providing System Air Flow information. | ||
| scfMIBNotifGroups | 1.3.6.1.4.1.211.1.15.3.1.3.2.2 | |||
| scfNotificationsGroup | 1.3.6.1.4.1.211.1.15.3.1.3.2.2.1 | The collection of notifications used to indicate events, alarms, and state changes that occur in the system. |
RFC description
Sun Microsystems/Fujitsu proprietary MIB for OPL (OpenMP Parallelization Layer) SPARC Enterprise systems monitoring and management.
Start monitoring Sun/Fujitsu SPARC Enterprise (M-series) server (service processor status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.