All MIBs › OPL-SP-MIB › scfSystemExhaustAirFlowMinPollingInterval
scfSystemExhaustAirFlowMinPollingInterval
Module: OPL-SP-MIB
OID (symbolic): OPL-SP-MIB::scfSystemExhaustAirFlowMinPollingInterval
OID (numeric): 1.3.6.1.4.1.211.1.15.3.1.1.4.11.3
Node type: OBJECT-TYPE
Type: Integer32
Access: read-only
Description: Minimum interval time in seconds between updates of scfSystemExhaustAirFlowValue. It is strongly recommended to get object scfSystemExhaustAirFlowValue with intervals longer than this value. It is meaningless to get value at smaller intervals, because, internally, scfSystemExhaustAirFlowValue will not be updated. When this feature is not supported, maximum value of INTEGER type is set as interval value.
What is scfSystemExhaustAirFlowMinPollingInterval?
Reports the minimum useful interval, in seconds, between reads of scfSystemExhaustAirFlowValue, since the underlying value isn't updated internally any faster; an unsupported feature reports the maximum INTEGER value here. An admin sets their polling interval for airflow monitoring to at least this value.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.211.1.15.3.1.1.4.11.3 snmpwalk -v2c -c public <target> OPL-SP-MIB::scfSystemExhaustAirFlowMinPollingInterval
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.211.1.15.3.1.1.4.11.3.1 snmpget -v2c -c public <target> OPL-SP-MIB::scfSystemExhaustAirFlowMinPollingInterval.1
Start monitoring Sun/Fujitsu SPARC Enterprise (M-series) server (service processor status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OPL-SP-MIB::scfSystemExhaustAirFlowMinPollingInterval OID value, configure state conditions and alerts, and monitor any Sun/Fujitsu SPARC Enterprise (M-series) server (service processor status) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.211 | fujitsu | Alert-Definition-Originator-MIB |
| 1.3.6.1.4.1.211.1 | product | CFAB-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.211.1.15 | solaris | OPL-SP-MIB |
| 1.3.6.1.4.1.211.1.15.3 | sparcEnterprise | OPL-SP-MIB |
| 1.3.6.1.4.1.211.1.15.3.1 | oplSpMIB | OPL-SP-MIB |
| 1.3.6.1.4.1.211.1.15.3.1.1 | scfObjects | OPL-SP-MIB |
| 1.3.6.1.4.1.211.1.15.3.1.1.4 | scfSystemInfo | OPL-SP-MIB |
| 1.3.6.1.4.1.211.1.15.3.1.1.4.11 | scfSystemAirFlow | OPL-SP-MIB |
| 1.3.6.1.4.1.211.1.15.3.1.1.4.11.3 | scfSystemExhaustAirFlowMinPollingInterval | OPL-SP-MIB |