OPL-SP-MIB :: scfSystemExhaustAirFlowValue

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › OPL-SP-MIB › scfSystemExhaustAirFlowValue

scfSystemExhaustAirFlowValue

Module: OPL-SP-MIB

OID (symbolic): OPL-SP-MIB::scfSystemExhaustAirFlowValue

OID (numeric): 1.3.6.1.4.1.211.1.15.3.1.1.4.11.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Exhaust air flow of the system. Set to 0 if this feature is not supported.

What is scfSystemExhaustAirFlowValue?

Reports the system's current exhaust air flow reading, or 0 if this feature isn't supported. An admin polls this for airflow/cooling monitoring, respecting the minimum polling interval in scfSystemExhaustAirFlowMinPollingInterval.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.211.1.15.3.1.1.4.11.1
snmpwalk -v2c -c public <target> OPL-SP-MIB::scfSystemExhaustAirFlowValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.211.1.15.3.1.1.4.11.1.1
snmpget -v2c -c public <target> OPL-SP-MIB::scfSystemExhaustAirFlowValue.1

Start monitoring Sun/Fujitsu SPARC Enterprise (M-series) server (service processor status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OPL-SP-MIB::scfSystemExhaustAirFlowValue OID value, configure state conditions and alerts, and monitor any Sun/Fujitsu SPARC Enterprise (M-series) server (service processor status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.211fujitsuAlert-Definition-Originator-MIB
1.3.6.1.4.1.211.1productCFAB-MIB
Numeric OIDNameModule
1.3.6.1.4.1.211.1.15solarisOPL-SP-MIB
1.3.6.1.4.1.211.1.15.3sparcEnterpriseOPL-SP-MIB
1.3.6.1.4.1.211.1.15.3.1oplSpMIBOPL-SP-MIB
1.3.6.1.4.1.211.1.15.3.1.1scfObjectsOPL-SP-MIB
1.3.6.1.4.1.211.1.15.3.1.1.4scfSystemInfoOPL-SP-MIB
1.3.6.1.4.1.211.1.15.3.1.1.4.11scfSystemAirFlowOPL-SP-MIB
1.3.6.1.4.1.211.1.15.3.1.1.4.11.1scfSystemExhaustAirFlowValueOPL-SP-MIB